| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹7.7 L+₹61,572.20 (8.75%)Rejected-AOC 00 RL QR NO 388 B KALIBARI COLONY ALIPURDUAR JN JALPAIGURI WEST BENGAL 736123 | ALIPURDUAR | WEST BENGAL | 736123 | L2 | Rejected-AOC L2 | |
| 3 | L3₹17.1 L+₹10.0 L (142.4%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
₹7.1 L
EMD Value
₹7,500
Closing Date
22 Nov 2023, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE, EDC, BDN
BUDAUN
39/EDCB/2023-24
2023_MVVNL_845855_1
39/EDCB/2023-24
Open Tender
Electrical Works
Item Rate
90 days
BUDAUN
AS PER TENDER DOCUMENT
3 documents required · 3 mandatory
₹1,180
A/c No. 1243002100806171, IFSC Code - PUNB0124300
₹7,500
17 May 2024
9 Nov 2023
23 Nov 2023
9 Nov 2023
22 Nov 2023
9 Nov 2023
9 Nov 2023 - 22 Nov 2023
Amount
Safe carriage including Loading/Unloading & proper stacking of following materials from Store Centre, Nawada, Badaun/JE Store to site of work (Approx. distance 0-50 Km.)
S.T. Pole 11 Mtr. Long
PCC Pole 8.5 Mtr. Long
11 KV Polymer Disc Insulator
11 KV V-Type X-Arms (65x65x6) mm
11 KV Polymer Pin Insulator
F-Bracket for fitting top insulator with bolts & nut
MS Channel 125x65x1300 mm (Tee-Off)
ACSR Raccoon Conductor
GI Wire 6 SWG and GI 10 SWG for Guarding
Stay Set Complete with grouting
Earthing Complete
11 KV VCB O/G CTR 200/100/5A, 350 MVA
33 KV 3X300 Sqmm XLPE Cable
11 KV 3x300 sqmm XLPE Cable Jointing Kit O/D
11 KV 3x185 sqmm XLPE Cable
11 KV 3x185 sqmm XLPE Cable Jointing Kit I/D
11 KV 3x185 sqmm XLPE Cable Jointing Kit O/D
Erection of the following support including cutting, making holes fixing of all types of accessories digging of pits complete in all respect as per RESSPO norms. All types of nuts & bolts, washer shall be provided by the contractor for execution of work.
Single support of ST Pole 11 Mtr. Long.
Single support of PCC Pole 8.5 Mtr. Long.
PCC Pole 8.5 Mtr Long Double Pole
ST Pole 11 Mtr Long Double Pole.
Grouting of 8.5 mtr long PCC/ST 11 Mtr. Long poles including cost of cement /B.B. and sand etc. the work shall be completed as per RESPO Norms. All the grouting material shall be provided by the contractor. .
The work of driving the earthing electrode and making connections with GI Wire as per RESPO norms as follows.
ST Pole 11 Mtr. long.
PCC Pole 8.5 Mtr. long.
Painting of ST Pole 11 Mtr. long. supports with one coat of red Oxide primer and two coats of aluminum white paint of ISI mark and top danger portion of each support must be painted by providing two coat of Post Office Red Paint (1.5 Mtr. Upper portion of support) Paint and material shall be provided by the contractor.
Erection/Fixing of stay set with stay wire and clamp as per RESSPO norms including binding. climbing, clamping, tightening and nozzeling etc. complete in all respect including its grouting in ratio 1:4:8 of cement, sand and brick ballast and sand etc. as per RESSPO norms. All the grouting material shall be provided by the contractor
Stringing and sagging of 11 KV overhead line on ACSR Raccoon Conductor as per RESSPO Norms.
Fixing of danger board on each location and G.I. barbed wire including proper clamping as per RESSPO Norms (Danger Board with clamps & bolts, nuts shall be provided by the contractor)
Laying of Single circuit 11 KV 3x185 sq.mm XLPE cable by drill method.
Fixing of 11 KV 3x185 Sq.mm XLPE Cable Inoutdoor jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work.
Fixing of 11 KV 3x185 Sq.mm XLPE Cable outdoor jointing kits after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work.
Erection/Installation of following new 11 KV Outgoing Panel (VCB) in control room and cable joint of the panel to pole including earthing, grouting of Anchor bolt of Panel and making/repairing of pocket for cable to insert in panel from trench and fixing, taping of bus bar with wiring for PT. AC, DC connection including providing of AC & DC Supply.
Clearing of the line route by cutting of tree branches during erection of line and also upto the time of energisation completely as per direction of Incharge.
The following Decentralized material shall be provided by the contractor for execution of work as per RESPO Norms (the material shall be purchased from approved vendor of Discom).
Stone Pad 300x300x75mm
Danger Board & clamps with bolts & nuts
Concreting of Pole
Red Oxide Paint
Aluminium Paint
Cross Arms Holding Clamps with Bolt & Nut
Barbed GI wire
Holding Clamp for Gaurding Angle
Gaurding Cross Arm 1.6 Mtr. Long
Dismantling of old & damaged 33 KV 3x300 sqmm. XLPE cable.
Laying of Single circuit 33 KV 3x300 sq.mm XLPE cable by drill method.
Filling of 33 KV 3x300 Sq.mm XLPE Cable Box (outdoor) after carefully removing the insulation of the cable duly plumbing and taping of cable providing, fixing and crimpling of proper size good quality lugs and complete work.
Safe back carriage of scrap material (if any) from work site to Store Center, Nawada, Budaun approx distance upto 0-50 Km including loading & unloading.
SHIV TRADERS
M/S SUPER ENGINEERING TRADERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .