| 1.00 | Taking down existing unserviceable BER Acs, Water Cooler and Refrigerators of any type and any capacity with all connected items complete after disconnecting the electric supply line and depositing at MES E/M store yard of GE Gangtok complete all as specified and as directed. . | 9 | Each | 4,010 ₹36,090 | 4,725 ₹42,525 | 3,900 ₹35,100 Lowest |
| 2.00 | Supply, install and commisioning of hi wall split AC Cooling & Heating function units indoor / outdoor, complete with cordless remote control unit, timer and with in built air ioniser and plasma filter for better indoor air quality, including suitable copper pipe from indoor unit to outerdoor unit, drain pipe from indoor unit to ground with minimum 5 STAR rating and ERE 3.51 capacity 1.5 tonnage complete all as specified and as directed. | 17 | Each | 1,05,000 ₹17,85,000 | 1,02,000 ₹17,34,000 | 1,01,500 ₹17,25,500 Lowest |
| 3.00 | Supply, install and commisioning of hi wall split AC Cooling & Heating function units indoor / outdoor, complete with cordless remote control unit, timer and with in built air ioniser and plasma filter for better indoor air quality, including suitable copper pipe from indoor unit to outerdoor unit, drain pipe from indoor unit to ground with minimum 5 STAR rating and ERE 3.51 capacity 2 tonnage complete all as specified and as directed. | 5 | Each | 1,40,000 ₹7,00,000 | 1,29,000 ₹6,45,000 Lowest | 1,35,000 ₹6,75,000 |
| 4.00 | Supply, installation, testing and commissioning of Solar Hot Water System (Flat Plate Collector) based on indirect transfer of heat of capacity 200 LPD hot water storage tank shall be made out of SS with rock wool insulation of thickness 100 mm minimum including necessary fixing frame over the roof with electrical heating coil backup of 3KW heating coil and necessary thermostat etc complete all as specified and as directed as per following specifications:-
(i) Solar flat plate collector with insulated outer metallic box covered on the top with glass sheet to collector system confirming to IS: 12933 (Pt-I).
(ii) Absorber shall be metallic sheet with built in channels or riser tubes to carry water.
(iii) sheet of absorber and absorber shall be made of copper. | 5 | Each | 98,000 ₹4,90,000 | 1,02,500 ₹5,12,500 | 96,500 ₹4,82,500 Lowest |
| 5.00 | Supply and installation,commissioning of water cooler fully stainless steel electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour complete all as specified and as directed. | 2 | Each | 62,000 ₹1,24,000 | 61,600 ₹1,23,200 | 59,300 ₹1,18,600 Lowest |
| 6.00 | Supply and install deep freezer hard top mimnimun 300 ltr capacity having double door complete 230 volt complete all as per directed by Engr-in-Charge. | 3 | Each | 44,000 ₹1,32,000 | 55,500 ₹1,66,500 | 41,700 ₹1,25,100 Lowest |
| 7.00 | Supply and fix double door refrigerator, electric driven (single phase), capacity minimun 240 Litres BEE 5 star rated 230 volt complete all as per directed by Engr-in-Charge. | 3 | Each | 57,000 ₹1,71,000 | 78,200 ₹2,34,600 | 56,000 ₹1,68,000 Lowest |
| 8.00 | Material and labour for point wiring 4 sq mm pvc insulated unsheathed copper cable 1100 volt grade drawn in and including PVC Casing-Caping not less than 20 mm width including spacers,saddles,scrws etc & 2.5 sq mm copper PVC insulated copper earth wire for 15 amps Plug socket including 2 mm thick MS Sheet fabricated terminal box for fixing switch socket Combination on idependent Board with 3 mm thick hylam sheet top cover complete all as specified and as directed. | 15 | Point | 2,000 ₹30,000 | 2,400 ₹36,000 | 1,875 ₹28,125 Lowest |
| 9.00 | M&L for concealed sub-main wiring along with earth wire of size e 2x04 sqmm with 1x4sqmm earth wire ,ISI marked FRLS ,PVC insulated ,multi stranded , copper conductor ,single core cable drawn through and incl PVC rigid conduit (medium grade) size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduit & sinking for sunken boxes & making good to walls, floors etc complete all as specified and directed. | 280 | RM | 325 ₹91,000 | 300 ₹84,000 | 265 ₹74,200 Lowest |
| 10.00 | M&L for concealed sub-main wiring along with earth wire of size e 2x06 sqmm with 1x6 sqmm earth wire ,ISI marked FRLS ,PVC insulated ,multi stranded , copper conductor ,single core cable drawn through and incl PVC rigid conduit (medium grade) size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduit & sinking for sunken boxes & making good to walls, floors etc complete all as specified and directed | 90 | RM | 380 ₹34,200 | 370 ₹33,300 | 345 ₹31,050 Lowest |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
22 Jun 2026, 6:00 pmClosed
GE Gangtok
GE Gangtok New Mil Stn Gangtok Sikkim
SPL REPAIR REPLACEMENT OF COOLING HEATING APPLIANCES UNDER GE GANGTOK
2025_MES_741676_5
8404/A/E8
Open Tender
Miscellaneous Works
Works
240 days
GE Gangtok New Mil Stn Gangtok Sikkim
As per tender document
8 documents required · 8 mandatory
₹500
GE Gangtok
₹76,000
Yes
27 Jun 2026
3 Jun 2026
24 Jun 2026
3 Jun 2026
22 Jun 2026
10 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down existing unserviceable BER Acs, Water Cooler and Refrigerators of any type and any capacity with all connected items complete after disconnecting the electric supply line and depositing at MES E/M store yard of GE Gangtok complete all as specified and as directed. . | 9 | Each | - | - |
| 2 | Supply, install and commisioning of hi wall split AC Cooling & Heating function units indoor / outdoor, complete with cordless remote control unit, timer and with in built air ioniser and plasma filter for better indoor air quality, including suitable copper pipe from indoor unit to outerdoor unit, drain pipe from indoor unit to ground with minimum 5 STAR rating and ERE 3.51 capacity 1.5 tonnage complete all as specified and as directed. | 17 | Each | - | - |
| 3 | Supply, install and commisioning of hi wall split AC Cooling & Heating function units indoor / outdoor, complete with cordless remote control unit, timer and with in built air ioniser and plasma filter for better indoor air quality, including suitable copper pipe from indoor unit to outerdoor unit, drain pipe from indoor unit to ground with minimum 5 STAR rating and ERE 3.51 capacity 2 tonnage complete all as specified and as directed. | 5 | Each | - | - |
| 4 | Supply, installation, testing and commissioning of Solar Hot Water System (Flat Plate Collector) based on indirect transfer of heat of capacity 200 LPD hot water storage tank shall be made out of SS with rock wool insulation of thickness 100 mm minimum including necessary fixing frame over the roof with electrical heating coil backup of 3KW heating coil and necessary thermostat etc complete all as specified and as directed as per following specifications:-
(i) Solar flat plate collector with insulated outer metallic box covered on the top with glass sheet to collector system confirming to IS: 12933 (Pt-I).
(ii) Absorber shall be metallic sheet with built in channels or riser tubes to carry water.
(iii) sheet of absorber and absorber shall be made of copper. | 5 | Each | - | - |
| 5 | Supply and installation,commissioning of water cooler fully stainless steel electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour complete all as specified and as directed. | 2 | Each | - | - |
| 6 | Supply and install deep freezer hard top mimnimun 300 ltr capacity having double door complete 230 volt complete all as per directed by Engr-in-Charge. | 3 | Each | - | - |
| 7 | Supply and fix double door refrigerator, electric driven (single phase), capacity minimun 240 Litres BEE 5 star rated 230 volt complete all as per directed by Engr-in-Charge. | 3 | Each | - | - |
| 8 | Material and labour for point wiring 4 sq mm pvc insulated unsheathed copper cable 1100 volt grade drawn in and including PVC Casing-Caping not less than 20 mm width including spacers,saddles,scrws etc & 2.5 sq mm copper PVC insulated copper earth wire for 15 amps Plug socket including 2 mm thick MS Sheet fabricated terminal box for fixing switch socket Combination on idependent Board with 3 mm thick hylam sheet top cover complete all as specified and as directed. | 15 | Point | - | - |
| 9 | M&L for concealed sub-main wiring along with earth wire of size e 2x04 sqmm with 1x4sqmm earth wire ,ISI marked FRLS ,PVC insulated ,multi stranded , copper conductor ,single core cable drawn through and incl PVC rigid conduit (medium grade) size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduit & sinking for sunken boxes & making good to walls, floors etc complete all as specified and directed. | 280 | RM | - | - |
| 10 | M&L for concealed sub-main wiring along with earth wire of size e 2x06 sqmm with 1x6 sqmm earth wire ,ISI marked FRLS ,PVC insulated ,multi stranded , copper conductor ,single core cable drawn through and incl PVC rigid conduit (medium grade) size not less than 25 mm with all fittings and accessories ISI marked including cutting chases for conduit & sinking for sunken boxes & making good to walls, floors etc complete all as specified and directed | 90 | RM | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.12 MB
Tenderspecification8404A.pdf
Tender Documents • 0.59 MB
BOQ_861865.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .