| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.5 LAccepted-AOC R2 612 GOPAL NAGAR BLOCK A DHANSA ROAD NAJAFGARH NEW DELHI 110043 | NEW DELHI | NAJAFGARH | DELHI | 110043 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹37.4 L+₹82,734.52 (2.27%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹39.0 L+₹2.5 L (6.76%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹40.8 L+₹4.3 L (11.8%)Rejected-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | M/S Anand Enterprises L2 | J.P. Enterprises L4 | Poorvi Enterprises L1 | Alliance Trading Corporation L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for concealed point wiring of one light point controlled by one switch with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC conduit, medium grade, ISI marked not less than 20mm dia, with all fittings including Tee, Junction boxes and provision of Modular Metal flush box and plate with frame of suitable module for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified.
Note :-
(i) The quoted rate is deemed to include for cutting/chasing for concealing the conduit and making good the surface to match the existing surfaces. | 100 | Per Point | 400 ₹40,000 Lowest | 550 ₹55,000 | 425 ₹42,500 | 1,000 ₹1,00,000 |
| 2.00 | All as per item No 01 here in before but For one fan/exhaust fan and wall mounted fan point controlled by one switch. | 7 | Per Point | 400 ₹2,800 Lowest | 550 ₹3,850 | 425 ₹2,975 | 1,200 ₹8,400 |
| 3.00 | All as per item No 01 here in before but For one bell point controlled by one bell push | 2 | Per point | 400 ₹800 Lowest | 550 ₹1,100 | 425 ₹850 | 1,500 ₹3,000 |
| 4.00 | All as per item No 01 here in before but for one 3 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size. | 7 | Per point | 200 ₹1,400 | 150 ₹1,050 Lowest | 235 ₹1,645 | 1,400 ₹9,800 |
| 5.00 | All as per item No 01 here in before but for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size. | 10 | Per Point | 500 ₹5,000 | 550 ₹5,500 | 490 ₹4,900 Lowest | 1,450 ₹14,500 |
| 6.00 | All as per item No 01 here in before but with 2.5 Sq mm cable for Independent board one 3 pin 15 Amps socket outlet including Single core 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FRLS cable for continuous earth wire 2.5 sqmm FRLS | 15 | Per Point | 500 ₹7,500 Lowest | 700 ₹10,500 | 520 ₹7,800 | 1,500 ₹22,500 |
| 7.00 | S & F Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge. | 124 | Each | 50 ₹6,200 | 60 ₹7,440 | 39 ₹4,836 Lowest | 150 ₹18,600 |
| 8.00 | S & F Modular Socket, 6A -3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge. | 17 | Each | 80 ₹1,360 Lowest | 110 ₹1,870 | 119 ₹2,023 | 200 ₹3,400 |
| 9.00 | S&F Modular switch 1 way 16A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge. | 15 | Each | 110 ₹1,650 | 130 ₹1,950 | 99 ₹1,485 Lowest | 170 ₹2,550 |
| 10.00 | S & F Modular Socket, 16A -3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge. | 15 | Each | 110 ₹1,650 Lowest | 150 ₹2,250 | 129 ₹1,935 | 150 ₹2,250 |
Tender Value
₹41.7 L
EMD Value
₹83,360
Closing Date
16 Jul 2025, 6:00 pmClosed
GE (AF) SUBROTO PARK
GE (AF) Subroto Park, Delhi Cantt Delhi-110010
As described in Bill of quantities
2025_MES_714643_1
GE/SP/TOKEN-02/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE (AF) SUBROTO PARK
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
GE (AF) SUBROTO PARK
₹83,360
Yes
11 Sept 2025
14 Jun 2025
19 Jul 2025
14 Jun 2025
16 Jul 2025
4 Jul 2025
Amount
M&L for concealed point wiring of one light point controlled by one switch with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 1.5 Sq mm FRLS (Nominal area) drawn through and including non metallic rigid PVC conduit, medium grade, ISI marked not less than 20mm dia, with all fittings including Tee, Junction boxes and provision of Modular Metal flush box and plate with frame of suitable module for mounting switch sockets and regulators and drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) complete all as specified. Note :- (i) The quoted rate is deemed to include for cutting/chasing for concealing the conduit and making good the surface to match the existing surfaces.
All as per item No 01 here in before but For one fan/exhaust fan and wall mounted fan point controlled by one switch.
All as per item No 01 here in before but For one bell point controlled by one bell push
All as per item No 01 here in before but for one 3 pin socket out let, 6 Amps on same board with the cable 1.5 Sqmm size.
All as per item No 01 here in before but for one 3 pin socket out let, 6 Amps on Independent board with the cable 1.5 Sqmm size.
All as per item No 01 here in before but with 2.5 Sq mm cable for Independent board one 3 pin 15 Amps socket outlet including Single core 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FRLS cable for continuous earth wire 2.5 sqmm FRLS
S & F Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 6A -3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F Modular switch 1 way 16A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 16A -3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
Supply and fix regulator rotary flush step type 120 watt, 240 volt 50 Hz AC complete compatible with BLDC fans complete all as specified and directed.
Supply and fix bell Modular push flush type 5 Amps suitable for 240 volt complete all as specified and directed.
Supply and fixing of ceiling roses, surface bakelite 65x50mm 3 terminals , PVC/Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed by Engineer-In- Charge.
Supply and fixing of Industrial Distribution Board with Plug & Socket Box Enclosures Sheet Metal (Without MCB) 5 Pole Three Phase IP44 Weather Proof Plug & Socket - 32 AMP Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing of ultra slim 18W LED Dazzle round surface downlighter 4000K-6000K, medium in solid PVC body suitable size as per ground availbility complete all as specified and directed by Engineer-In- Charge.
Supply and fix LED batten luminaire surface mounted ,4 feet system wattage of not less than 20 Watts with lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC, system efficacy at luminarie level > 120 Lumens/watt, filcker free (Ripple less than 5%) and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed with 5 years of replacement warranty on fittings complete all as specified and directed.
Supply and fixing ultra slim 24 watt LED round surface downlighter of , 4000K to 6500K ,warm white 230 volt, LED ceiling fitting, complete with all accessories , connecting up with twin core twisted flexible copper conductor cable , and testing complete all as specified and directed by the Engineer-In- Charge.
Supply and fix of ventil type exhaust fan 200mm of white colour with twin core flexible copper conductor cable all as specified and directed by Engineer-in-Charge.
Supply and installation in replacemnt of phase frequency corrector for 3 phase tower/cassate/ductable Split AC and other 3 phase items , electrically controlled with interlocking system duly pre wired with multistranderd copper wire of duirable rating , powder coated metalic housing with hanged door and indicator for each phase. current rate 40A- 100 A, Voltage rating 440V all as specified and directedby Engr-in- Charge.
Supply and fixing of load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting 8 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable for MCCB of 125 Amps =01 No MCCB for outgoing complete all as specified and as directed by Engineer-in-Charge. Note :- MCCB shall be measured and paid seperately.
S&F MCB SP 6 to 32 Amps 10 KA, 240 volt 'C' Series complete all as specified and directed by engineer-in-charge.
S & F in replacement of MCCB 4 pole 415 V, adjustable type 125 amps with breaking capacity of 16 KA complete all as specified and directed by Engr in charge.
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron wire 4 mm dia as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate No 3 of SSR Part I (2009) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified and directed. Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to and including galvanized iron strip 25X4mm as earth lead by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 3 of SSR Part I (2009) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified and directed. Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
Supply, Laying, Testing and connecting cable XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade cross section area of 120 sqmm 3.5 core complete all as specified and directed by engineer-in-charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m deep, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed
Removal of excavated material / soils to a distance n exc 50m and depositing where directed at a level not exceeding 1.5m above the straight point complete all as specified and directed.
Returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm in soft / loose soil complete all as specified and directed.
M&L sand cushioning using dry and clean sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed.
Supply and laying reinforced precast concrete cable cover class LV ,type I,flat ,size 250mmx150mmx 40 mm for cable protection over cable perpendicular to direction of cable per complete all as specified and directed.
S&F of submain wiring with two single core PVC insulated unsheathed cable 1100 volts FRLS grade with multistranded copper conductor and drawn through and including PVC conduit along with continous earth wire but in green colour complete on surface/concealed/existing as per site requirement connected to earth dolly of the following size- Note-six run of PVC cable and one run of PVC conduit shall be measured as unit length. (a)10 sqmm (4 single run of 10 sqmm and two run of 10 sqmm as earth wire)
Material and labour for cutting of road/ hard standing up to a size not exceeding 20cm width and not exceeding 60cm in depth for laying of cable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 and block top with black bituminous upto existing surface level complete all as specified and as directed by Engineer-in-charge.
M&L for PCC type D-2 ( 1:4:8) using 40mm graded stone aggregates in foundation incl neccessory form work and fair finis to exposed surface without using extra cement etc.complete all as specified and directed
Design, supply, install, testing and commissioning in replacement of factory made LT Panel Outdoor type, cubical enclosure compartmentalized external and internal mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2.00 mm thick stainless steel sheet SS 316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. Degree of protection shall be IP-54. The enclosure shall have provision of cable entry. Cable entry from bottom side including internal wiring with PVC insulated solid, copper wire, 1100 volts grade. The panel shall consist of 1000 Amps rating TPN aluminium bus bars and shall be provided with colour coded heat shrinkable sleeves. The panel shall be provided with separate compartments for each switch grar, including instrumentation such as Ampere meter, Volt meter, phase indicating lamps etc with double stud hinged door, front & rear openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts grade, 3 Phase, 415 Volts, 50 cycles, AC Supply and to with stand short circuit fault level of not less than 10KA. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following: Incoming:- (a) MCCB 400 Amps 4 Pole, 36 kA, 50Hz at 440 Volts with Fixed Thermal and Fixed Magnetic including neccessary bus bar for connection incoming cables complete- 1 set (b) Digital Multifunction Meter to measure V, A, F, PF, KWh including CT complete with all electrical connection - 01 No (c) LED type Phase indicator lamps (R, Y, B) with Control MCB 6 Amps SP- 1 Set Outgoings:- (a) MCCB 160 Amps 4 pole rupturing capacity 25 KA at 415 volt Fixed Thermal & Fixed Magnetic Setting - 01 Nos (b) MCCB 125 Amp,4 pole rupturing capacity 25 KA at 415 volt Fixed Thermal & Fixed Magnetic Setting - 06 Nos Note : (i) Rates are inclusive for fixing of suitable size cable gland if required in existing or new cable, CT and electrical connections complete to function multi functional meter. (ii) Danger notice plate must be fixed on panel. (iii) For all MCCBs Ics = 100 Icu (iv) The panel manufacturer should have Govt. Approved Certificates: (a) Panel should be according to IEC-61439, CPRI Certification Degree of Protection IP-54 (b) IS/IEC : 61439 (Part-I and Part-II) 2011 and all necessary certification as per relevant IS/IEC codes.
Design, supply, install, testing and commissioning in replacement of factory made LT Panel Outdoor type, cubical enclosure compartmentalized external and internal mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2.00 mm thick stainless steel sheet SS 316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. Degree of protection shall be IP-54. The enclosure shall have provision of cable entry. Cable entry from bottom side including internal wiring with PVC insulated solid, copper wire, 1100 volts grade. The panel shall consist of 1000 Amps rating TPN aluminium bus bars and shall be provided with colour coded heat shrinkable sleeves. The panel shall be provided with separate compartments for each switch grar, including instrumentation such as Ampere meter, Volt meter, phase indicating lamps etc with double stud hinged door, front & rear openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts grade, 3 Phase, 415 Volts, 50 cycles, AC Supply and to with stand short circuit fault level of not less than 10KA. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following: Incoming:- (a) MCCB 250 Amps 4 Pole, 36 kA, 50Hz at 440 Volts with Fixed Thermal and Fixed Magnetic including neccessary bus bar for connection incoming cables complete- 1 set (b) Digital Multifunction Meter to measure V, A, F, PF, KWh including CT complete with all electrical connection - 01 No (c) LED type Phase indicator lamps (R, Y, B) with Control MCB 6 Amps SP- 1 Set Outgoings:- (a) MCCB 160 Amps 4 pole rupturing capacity 25 KA at 415 volt Fixed Thermal & Fixed Magnetic Setting - 03 Nos (b) MCCB 125 Amp,4 pole rupturing capacity 25 KA at 415 volt Fixed Thermal & Fixed Magnetic Setting - 02 Nos (c) MCCB 100 Amp,4 pole rupturing capacity 25 KA at 415 volt Fixed Thermal & Fixed Magnetic Setting - 02 Nos Note : (i) Rates are inclusive for fixing of suitable size cable gland if required in existing or new cable, CT and electrical connections complete to function multi functional meter. (ii) Danger notice plate must be fixed on panel. (iii) For all MCCBs Ics = 100 Icu (iv) The panel manufacturer should have Govt. Approved Certificates: (a) Panel should be according to IEC-61439, CPRI Certification Degree of Protection IP-54 (b) IS/IEC : 61439 (Part-I and Part-II) 2011 and all necessary certification as per relevant IS/IEC codes.
Design, supply, install, testing and commissioning in replacement of factory made LT Panel Outdoor type, cubical enclosure compartmentalized external and internal mirror type brushed suitable for highly corrosive environment, high creep resistance, better mechanical properties like ductility, yield strength, hardness etc.The enclosure shall be made of 2.00 mm thick stainless steel sheet SS 316 sheet. The fixing of double doors shall be on SS hinges with anti-theft provision. All fabrication/welding shall be done with TIG/MIG or as approved by Engineer in charge suitable for SS 316. Sliding handle and locking arrangement front and rear both side. Enclosure shall be suitable for AC supply system 415 volts, 3 phase, 4 wire, 50 Hz. Degree of protection shall be IP-54. The enclosure shall have provision of cable entry. Cable entry from bottom side including internal wiring with PVC insulated solid, copper wire, 1100 volts grade. The panel shall consist of 1000 Amps rating TPN aluminium bus bars and shall be provided with colour coded heat shrinkable sleeves. The panel shall be provided with separate compartments for each switch grar, including instrumentation such as Ampere meter, Volt meter, phase indicating lamps etc with double stud hinged door, front & rear openable with locking arrangement including interlocking with switch gears and suitable for 1100 Volts grade, 3 Phase, 415 Volts, 50 cycles, AC Supply and to with stand short circuit fault level of not less than 10KA. The panel shall be fixed with angle iron frame made of angles of size 50 X 50 X 6mm, embedded 200 mm below ground level in PCC 1:2:4, Type B-1 using 20mm grade stone aggregate, 600 mm above ground level and comprising the following: Incoming:- (a) MCCB 630 Amps 4 Pole, 36 kA, 50Hz at 440 Volts with Fixed Thermal and Fixed Magnetic including neccessary bus bar for connection incoming cables complete- 1 set (b) Digital Multifunction Meter to measure V, A, F, PF, KWh including CT complete with all electrical connection - 01 No (c) LED type Phase indicator lamps (R, Y, B) with Control MCB 6 Amps SP- 1 Set Outgoings:- (a) MCCB 250 Amps 4 pole rupturing capacity 36 KA at 415 volt Fixed Thermal & Fixed Magnetic Setting - 01 Nos (b) MCCB 125 Amp,4 pole rupturing capacity 25 KA at 415 volt Fixed Thermal & Fixed Magnetic Setting - 11 Nos Note : (i) Rates are inclusive for fixing of suitable size cable gland if required in existing or new cable, CT and electrical connections complete to function multi functional meter. (ii) Danger notice plate must be fixed on panel. (iii) For all MCCBs Ics = 100 Icu (iv) The panel manufacturer should have Govt. Approved Certificates: (a) Panel should be according to IEC-61439, CPRI Certification Degree of Protection IP-54 (b) IS/IEC : 61439 (Part-I and Part-II) 2011 and all necessary certification as per relevant IS/IEC codes.
Supply and installed inverter type 5 star rating Tower AC type units indoor/outdoor complete with cordless remote control unit ,with rotary compressor, copper condensor and evaporator coil, three phase 380V - 415V, 50 Hz of capacity of 4.5 TR for installation on floor/ceiling fixing with proper brackets, clamping without damaged existing ceiling after finishing making good disturbed complete all as specified and directed By Engr-in-Charge.
M&L cross arms bracings suppots clamps and back plates fabricated from structural steel sections including nuts bolts washers welding bending cold or hold drilled holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under and one finished coat of paint for installation of condesning unit on the wall / ground complete all as specified and as directed by Engineer-in-charge.
S&F Low density polyethylene pipes (LDPE) 25 mm dia of pressure rating 6 kg/cm2 fixed complete to walls, ceilings or in floors etc. including accessories, clamps and fastners complete all as specified and as directed by Engineer-in-charge
M&L laying of copper tubing of dia 3/8" including insulation and brazing work complete, all as specified and as directed by Engineer-in-charge.
M&L laying of copper tubing of dia 5/8" including insulation and brazing work complete, all as specified and as directed by Engineer-in-charge.
Supply, installing, testing and commissioning of non clog vertical submersible pumps of capacity 1 HP , 100 LPM at 25 mtr head ,415 V , 50 Hz with chrome steel impeller and cutter, non-clog to pass 40 mm size particles including Supply, installation with guide rail and lifting chain, complete all as specified and directed.
S&F for Submersible water proof cable 3 core 4 Sqmm copper cable flat type complete all as specified and as directed.
Supply and fixing hose real pipe of dia 63 mm and 15 meter in length incliding necessary fixing arrangment for coupling with pipe complete all as specified and directed .
M&L for flame proof Point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multi strand copper conductor of size 2.5 Sq mm FRLS (Nominal area) drawn through and including metallic ERW conduit.ISI marked not less than 20mm dia, concealed in wall, ceiling with GI saddles GI screws, rawl plugs (concealed conduit wiring) with all fittings including drawing continuous earth wire of PVC insulated unsheathed 1100 Volts grade cable with stranded copper conductor of size 2.5 Sq mm (Nominal area) including conduit accessories for one light point controlled by one switchcomplete all as specified and directed. Note: Cost for cutting, chasing and making good to existing surfaces are deemed to be included in the Quoted Rate.
All as per item 45 here in before but for one Exhaust fan point controlled by one switch one way.
S & F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
S&F Flame proof junction boxes Epoxy finish LM6 (4 way) aluminium alloy housing with accessories complete all as specified and directed.
Supply and fixing LED light fitting 2 x 16 watt flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size etc internally prewired complete all as specified and directed.
Supply and Fix Flame Proof class 1 Zone 1 Weather proof wall mounting Exhaust Fan 12" sweep, 1440 RPM single phase, suitable rated 240 Volts, 50 Cycles with CMR / CPRI hazardous area gas groups IIA/IIB with fabricated construction casing suitable propeller wheel with dynamically balanced blades to avoid frictional spark hazar dous front and rear wire guards - 01No, M-20 cable entry etc suitable for wall / bracket mounting arrangement etc, duly dark grey epoxy powder coated as per shade 632 of IS - 5 including writing MES NO. 2 CM height with synthetic enamelled black paint complete all as specified and directed.
M & L in replacement for submain wiring with two run of single core 6.0 sqmm PVC insulated but unsheathed FRLS cable of specified size of multistranded copper conductor 1100 volts grade IS:694 marked and one run of 6.0 sqmm PVC insulated but unsheathed FRLS cable for earth continuty conductor drawn through and under suitable size of steel metallic conduit , ISI marked ( not less than 20 mm dia) complete with all acessories and fittings all laid/fixed concealed in wall/ceiling or surface in wall and surface conduit on ceiling, and also include the specified runs of specified size earth continuity conductor of similar type cablecomplete all as specified and directed. Note- 2 Runs of 6.0 Sqmm single core cable and one run of 6.0 sqmm single core cable with one run of pvc conduit shall be measuared as one unit for payment purpose.
Supply and fix Flame proof Weather Proof, MCB DB SPN 4 way in Cast Aluminium alloy LM6 construction , as per IS : 2148, 240 V AC 50Hz with MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar, neutral link earth link, complete all as specified and directed .
S&F MCB 20A DP 250 volts,AC P+N+E, ISI Marked 10 KA complete all as specified and directed
S&F MCB 10A Singal Pole on-off , ISI Marked 10 KA complete all as specified and directed
S&F of 4 core flexible copper cable of size 4.0 Sqmm 1100V grade complete fixing on wall by claping/securing including conncetions "in PVC caring capaciting" complete all as specified and directed.
M/S Anand Enterprises (BID ID -3352197)
Alliance Trading Corporation (BID ID -3347996)
J.P. Enterprises (BID ID -3352778)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .