| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹4.4 LAccepted-AOC | ₹4.4 L | L-1 | Accepted-AOC Work awarded to lowest Contractor |
| 2 | L-2₹4.4 L+₹2,217.17 (0.51%)Rejected-AOC | ₹4.4 L+₹2,217.17 (0.51%) | L-2 | Rejected-AOC L-2 |
| 3 | L-3₹4.4 L+₹4,984.99 (1.14%)Rejected-AOC | ₹4.4 L+₹4,984.99 (1.14%) | L-3 | Rejected-AOC L-3 |
| 4 | L-4₹4.6 L+₹20,420.79 (4.65%)Rejected-AOC HIMACHAL PRADESH HP | ₹4.6 L+₹20,420.79 (4.65%) | L-4 | Rejected-AOC L-4 |
| 5 | L-5₹4.8 L+₹38,613.53 (8.80%)Rejected-AOC | ₹4.8 L+₹38,613.53 (8.80%) | L-5 | Rejected-AOC L-5 |
Tender Value
₹4.8 L
EMD Value
₹10,000
Closing Date
3 Jan 2022, 5:30 pmClosed
Executive Engineer
Executive Engineer, Kalpa Division, HP.PWD. Kalpa , Distt. Kinnaur HP
Special Repair to General Pooled Accommodation at R/Peo (SH- Providing shelf, flooring, plinth protection, tiles, marble, painting, distempering, roof painting and sanitary fittings in Block No.- 8 , Ty--II qtr. No. 39 to 42
2021_PWD_55076_2
PW-KNR-E-Tender-21-9291-99 dated 14-12-2021
Open Tender
Repair and Maintenance Works
Item Rate
90 days
Reckong Peo, Kinnaur HP
Please refer Tender documents.
7 documents required · 7 mandatory
₹350
EE Kalpa Division
₹10,000
16 Jan 2023
27 Dec 2021
4 Jan 2022
27 Dec 2021
3 Jan 2022
27 Dec 2021
Amount
Demolishing cement concrete manually/ by mechanical means including disposal of material upto all lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 (One cement: three sand: six aggregate) or richer mix (i/c equivalent design mix), including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material upto all lead as per direction of Engineer-in-charge : In cement mortar, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (One Cement : three coarse sand: six graded stone) aggregate 40 mm (Forty millimeter) nominal size, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (One Cement : two coarse sand: four graded stone) aggregate 40 mm (Forty millimeter) nominal size, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Centering and shuttering including strutting, propping etc. and removal of form for : Shelves (Cast in situ), including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately). Sal wood, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-incharge. (Note:- But hinges and necessary screws shall be paid separately) second class teak wood , 35 mm (thirty five millimeter) thick shutters, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete 200x10 mm (two hundred into ten millimeter) , including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete 250x16 mm (two hundred into sixteen millineter), including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete, 100 mm (Hundred millimeter) including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Renewing glass panes, with wooden fillets wherever necessary: Float glass panes of nominal thickness 4mm (four millimeter) (weight not less than 10kg/sqm), including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm (eight millimeter) diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80 mm (zero point eighty millimeter) thick with zinc coating not less than 275gm/ m² (two hundred seventy five grame per square meter), including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Making plinth protection 50mm thick of cement concrete 1:3:6 (One cement : Three coarse sand (zone - III) : Six graded stone aggregate 20 mm (twenty milimeter) nominal size) over 75mm (Seventy five milimeter) thick bed of dry brick ballast 40 mm (forty milimeter) nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm (twelve millimeter) thick bed of cement Mortar 1:3 (One cement: three coarse sand) and jointing with grey cement slurry @ 3.3kg (three point three killograme) per sqm (square meter) including pointing in white cement mixed with pigment of matching shade complete, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (three hundred into three hundred millimeter) (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm (twenty millimeter) thick cement mortar 1:4 (One Cement : four Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm (three point three kilograme/square meter including pointing the joints with white cement and matching pigment etc., complete, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and fixing 18 mm (eighteen millimeter) thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm (twenty millimeter) thick base cement mortar 1:4 (one cement : fou rcoarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Raj Nagar Plain white marble/ Udaipur green marble/ Zebra black marble: Area of slab over 0.50 sqm (square meter), including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
15 mm (fifteen milimeter) cement plaster on rough side of single or half brick wall of mix: 1:4 (one cement: four coarse sand), including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 (fifty) grams/ litre of approved brand and manufacture to give an even shade : Old work (one or more coats), including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour Two coats, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm (forty milimeter), including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain, 610x510 mm (six hundred ten into five hundred ten) bowl depth 200, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete Flexible pipe 32 mm (thirty twi mllimeter) diameater, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
100 mm (Hundred millimeter) inlet and 100 mm (Hundred millimeter) outlet,Sand Cast Iron S&S as per IS: 1729
100 mm (Hundred millimeter) inlet and 75 mm (seventy five millimeter) outlet, Sand Cast Iron S&S as per IS- 1729
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 15 mm (fifteen millimeter) diameter nominal bore, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and fixing brass bib cock of approved quality : 15 mm (fifteen millimeter) nominal bore, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (one cement : five coarse sand: ten graded stone) aggregate 40 mm (forty millimeter) nominal size, in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m (one point five meter) in width or 10 sqm (ten square meter) on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m (one point five millimeter), including getting out the excavated soil and disposal of surplus excavated soil as directed, upto all lead. All kinds of soil, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Applying a coat of mordant solution on G.S. sheet: With a solution of 38 gms (thirty eight grames) of copper acetate in a litre of soft water, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Old work (one or more coats), including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 (ten) litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and fixing 8 mm (eight millimeter) diameter C.P. / S.S. Jet with flexible tube upto 1 (one)metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge, including carriage of materials through all modes of portation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm (forty five centimeter) length, 15 mm (fifteen millimeter) nominal bore, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931, 15mm (fifteen (millimeter) nominal bore, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and fixing 100 mm (hundred millimeter) sand cast Iron grating for gully trap, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm (ten milimeter) gap for thermal expansion, (i) Single socketed pipes, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
(a) 75 mm (seventy five milimeter) diameter
(a) 110 mm (one hundred ten milimeter) diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm (ten milimeter) gap for thermal expansion Bend 87.5°, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
(a) 75 mm (seventy five millimeter)
(b) 110 mm (One hundred ten millimeter)
Single tee with door (a) 75x75x75 mm (seventy five into seventy five into seventy five milimeter)
(b) 110x110x110 mm (one hundred ten into one hundred ten into one hundred ten milimeter)
Bend 87.5° (a) 75 mm (seventy five millimeter)
(b) 110 mm (One hundred ten millimeter)
Providing and applying plaster of paris putty of 2 mm (two milimeter) thickness over plastered surface to prepare the surface even and smooth complete, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (one cement : four coarse sand) C.I. cover with frame (light duty) 455x610 mm (four hundred fiftyfive into six hundred ten milimeter) internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (one cement : one point five Fine sand : three graded stone aggregate 20 mm (twenty milimeter)nominal size), foundation concrete 1:5:10 (one cement : five fine sand : ten graded stone aggregate 40 mm (forty milimeter) nominal size), inside plastering 12 mm( twelve milimeter) thick with cement mortar 1:3 (one cement : three coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm( four hundred fifty five into six hundred ten milimeter) and 45 cm deep for single pipe line : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5, including carriage of materials through all modes of transportation with in all leads and lifts, as per PWD specifications and as per direction of the Engineer-in-charge.
CONTRECTOR
MOHIT NEGI
M/S ANURAG NEGI
Sunil Kumar Con
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .