Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC SHREE KUNJ HOUSE NO 22B JIBAN KRISHNA PATH NEAR L P SCHOOL HENGRABARI GUWAHATI PIN 781036 | GUWAHATI | KAMRUP | ASSAM | 781036 | L1 | Accepted-AOC Lowest Bid | |
| 2 | L2₹25.4 L+₹3.0 L (13.4%)Rejected-Finance SANTIPUR HILL SIDE PS BHARALUMUKH GUWAHATI 781 009 | KAMRUP METRO | ASSAM | 781009 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹26.5 L+₹4.1 L (18.5%)Rejected-Finance 1ST FLOOR P R COMPLEX AT ROAD GUWAHATI 781 001 | KAMRUP METRO | ASSAM | 781001 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹26.9 L+₹4.5 L (20.0%)Rejected-Finance R G BARUAH ROAD NEAR SHIV MANDIR GUWAHATI AIRPORT GUWAHATI 781015 | KAMRUP METRO | ASSAM | 781015 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹24.5 L
EMD Value
₹49,000
Closing Date
9 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Borjhar
Garrison Engineer (AF) Borjhar, Military Engineer Services, Guwahati Airport- PO, Borjhar Airport, Guwahati, Assam, Pin- 781015 Tele 0361 - 2840127
Provn of certain work services for AFLS at 19 Wing AF under GE (AF) Borjhar
2022_MES_519293_1
8284/BOR/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Borjhar
MES Contractor enlisted as Class E category a(i) and b(i) having deposited Standing Security of Rs 50000.00 with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Borjhar
₹49,000
Yes
31 Aug 2022
21 Apr 2022
11 Jun 2022
21 Apr 2022
9 Jun 2022
5 May 2022
60 days
Amount
Supply, install, testing, commissioning LT cubicle type distribution panel, IP-54 type (manufactured from CPRI type tested manufacturer i.e Indo Asian or BCH or Neptune) of minimum size 1750mm x 2500mm x 500mm, indoor type made out of 2.00 mm thick CRCA sheet supported on structural frame and angle, factory made, fixed on the ground by galvanised nut & bolts, PCC works (1:2:4 Type B-1) . The LT cubicle type distribution panel should have enamelled danger notice plate of 1.6 mm thick, duly painted with powder coated paint of shade RAL 7032 (internally & externally) complete all as specified and directed by Engr-in-Charge. The LT distribution panel must have stainless steel hinges, with special type of heavy duty stainless steel front & back door opening, locking arrangements. The Panel should have provision/accommodation of the following electrical items :- INDICATING DEVICES (a) Three Phase LED Ammeter, Class - 1 with CT (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No (b) Three Phase LED Voltmeter, Class - 1 (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No (c) LED type panel indicator lamp Make- L&T/Schneider/ABB = 03 Nos
BUS BAR :- (d) Aluminium bus bar 4 strips (covered with PVC insulated sleeves as per colour code) 1600 Amps capacity, including connection etc complete =01 Set INCOMING :- (e) Air Circuit Breaker 800 Amps 415 Volts (Vertically Placed), 4 pole 50 KA (at 440V AC) breaking capacity, MDO type with microprocessor based release with over load protection (adjustable from 40-100% with time delay adjustment), short circuit protection (adjustable from rated current with time delay adjustment), ground fault protection (adjustable from rated current with time delay adjustment) & front operated handle Make-L&T (Cat No. SL 96061)/ Siemens/ L&T/ ABB = 01 No OUTGOING:- (f) Moulded case circuit breaker 200-250 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make-L&T/ Siemens/ABB/ Legrand = 02 No
(g) Moulded case circuit breaker 160 - 200 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make-L&T/ Siemens/ABB/ Legrand = 02 No (h) Moulded case circuit breaker 125 - 160 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make-L&T/ Siemens/ABB/ Legrand = 04 No (j) Moulded case circuit breaker 100 - 125 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make-L&T/ Siemens/ABB/ Legrand = 03 No (k) Moulded case circuit breaker 80 - 125 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make-L&T/ Siemens/ABB/ Legrand = 03 No Note- The connection between the MCCB and bus bar should be done by aluminium bar of suitable rating ll as specified and directed.
Supply, install, testing, commissioning LT cubicle type distribution panel, IP-54 type (manufactured from CPRI type tested manufacturer i.e Indo Asian or BCH or Neptune) indoor type made out of 2.00 mm thick CRCA sheet supported on structural frame, angle or channel, factory made, fixed on the ground by galvanised nut & bolts, PCC works (1:2:4 Type B-1) . The LT cubicle type distribution panel should have enamelled danger notice plate of 1.6 mm thick, duly painted with powder coated paint of shade RAL 7032 (internally & externally) complete all as specified and directed by Engr-in-Charge. The LT distribution panel must have stainless steel hinges, with special type of heavy duty stainless steel front & back door opening, locking arrangements. The Panel should have provision/accommodation of the following electrical items :- INDICATING DEVICES (a) Three Phase LED Ammeter, Class - 1 with CT (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No (b) Three Phase LED Voltmeter, Class - 1 (size 96mm x 96mm) Make- L&T/Schneider/ABB = 01 No (c) LED type panel indicator lamp Make- L&T/Schneider/ABB = 03 Nos
BUS BAR :- (d) Aluminium bus bar 4 strips (covered with PVC insulated sleeves as per colour code) 1600 Amps capacity, including connection etc complete =01 Set INCOMING :- (e) Moulded case circuit breaker 125 - 160 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make-L&T/ Siemens/ABB/ Indo Asian/ Legrand = 02 Nos OUTGOING:- ((f) On-Load Manual Change Over Switch (Open Execution Type) 125 Amps 415 Volts, 4 pole Make - L&T/ Siemens/ABB = 01 No
(g) Moulded case circuit breaker 80 - 125 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - L&T/ Siemens/ ABB/ Legrand = 01 No (h) Moulded case circuit breaker 40 - 50 Amps 415 Volts (Vertically Placed), 4 pole 25 KA breaking capacity, Ics=100% Icu, adjustable overload settings 0.8 - 1.0 x In, adjustable short circuit settings 6 - 10 x In Make - L&T/ Siemens/ ABB/ Legrand = 02 No Note- The connection between the MCCB and bus bar should be done by aluminium bar of suitable rating ll as specified and directed.
Excavating in trenches manually not exceeding 1.5m wide and not exceeding1.5 mtr in depth/ width for laying under ground cable / foundations and getting out in soft / loose soil all as specified and directed. Note: During excavation no mechanical excavator is permitted at site, contractor will do the excavation through maually.
Returning, filling in incl spreading, leveling, watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removing of surplus excavating material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point all as specified and directed.
M&L for sand cushioning for protection of LT under ground cable with screen wash sand and punning to proper reqd cover all as specified and directed.
5. M & L brick protection with old size sub class ‘B’ brick for PVC under ground cable protection in trench with width equal to length of brick laid dry and flat joining each other with gap between adjacent brick not exceeding 10mm over LT under ground cable all as specified and directed.
M&L connection to Panel, Feeder Pillar Box, DB or any other indicatated location by heavy duty round wire armoured LT under ground cable 70 sqmm, 3.5Core, 1100 V grade HR PVC insulated , HR PVC inner & outer sheathed ,multi stranded aluminium cable conforms to IS 7098/(Part-I) 1988 with latest ammendments in pipe /trench /cable duct /fixed on wall by proper size shaped GI clamps with nut bolts etc and making good the disturbed surfaces by cement mortar/paint to match with the existing surfaces complete all as specified & directed. Make-PolyCab /KEI/ Havells. Note:- All connections to Panel, Feeder Pillar Box, DB or any other indicatated location should be carried out through aluminium lugs or terminal of suitable sizes
M&L connection to Panel, Feeder Pillar Box, DB or any other indicatated location by heavy duty round wire armoured LT under ground cable 6 sqmm, 2.0 Core, 1100 V grade HR PVC insulated , HR PVC inner & outer sheathed ,multi stranded aluminium cable conforms to IS 7098/(Part-I) 1988 with latest ammendments in pipe /trench /cable duct /fixed on wall by proper size shaped GI clamps with nut bolts etc and making good the disturbed surfaces by cement mortar/paint to match with the existing surfaces complete all as specified & directed. Note:- All connections to Panel, Feeder Pillar Box, DB or any other indicatated location should be carried out through aluminium lugs or terminal of suitable sizes
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for laying pipe for throughing cable in bituminous macadum road / hardstanding all as specified and directed.
M&L for boring under roads by reqd T&P without disturbing the top surface of the road for throughing the cable in GI Pipe all as specified and directed.
M&L for earthing copper earth plate electrode 900x600x5 mm thick with charcoal & salt and treating the surrounding soil with magnesium sulphate, buried directly in ground (earth pit not less than 2.4 m depth below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to copper strip 32x6mm mm dia by means of brass nut, bolt, washer & protection pipe for earth strip from the earthing plate to the equipment/ test point/ panel, (50 mm bore, Light grade), watering pipe from plate to earthing pit (20 mm bore, medium grade), funnel with wiremesh. The earthing pit made up of PCC 1:3:6 type CI and pit cover made up of 40 mm thick pre cast RCC 1:2:4 type BI reinforced with 6 mm dia TMT rod and suitable handle of 8 mm dia TMT rod incl necessary earth work complete all as shown in SSR Part 1 plate no. as specified & directed. Note:- i) The copper strip and protection pipe beyond 7.5 m length shall be measured and paid separately. However, earthwork for the same is deemed to be included in this rate. ii) Chemical like magensium sulphate of minimum quantity 150 kg for treatment of surrounding soil is deemed to be included in this rate. iii) The desired value of earth resistance is less than 2 Ω, on testing after completion if the desired earth resistance is not obtained; the earthing will be redone at no extra cost, otherwise it will not be measured and paid to the contractor. iv) The approx size of earth work for chemical treatment of soil and earthing is 2.4m X 1.5m X 0.6m {D X L X W] and form work of size1.2m X 0.9m X 0.6m for pouring charcoal & salt is deemed to be included in this rate v) During earth work if surface water found at site, the cost for dewatering through pumpset is deemed to be included in this rate.
Earthing complete with copper earth plate electrode 600x600x3.15 mm thick buried directly in ground (earth pit not less than 2.25 m depth below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to copper strip 20x3mm mm dia by means of brass nut, bolt, washer& protection pipe for earth wire from the earthing plate to the DB/main switch/Panel, (40 mm bore, Light grade), watering pipe from plate to earthing pit (20 mm bore, medium grade), funnel with wiremesh. The earthing pit made up of PCC 1:3:6 type CI and pit cover made up of 40 mm thick pre cast RCC 1:2:4 type BI reinforced with 6 mm dia TMT rod and suitable handle of 8 mm dia TMT rod incl necessary earth work as shown in SSR Part 1 plate no.5 as specified & directed. Note:- i) The copper strip and protection pipe beyond 7.5 m length shall be measured and paid separately. However, earthwork for the same is deemed to be included in this rate. ii) The desired value of earth resistance is less than 5 Ω, on testing after completion if the desired earth resistance is not obtained; the earthing will be redone at no extra cost, otherwise it will not be measured and paid to the contractor. iii) Form work of size 0.9m X 0.9m X 0.6m for pouring charcoal & salt is deemed to be included in this rate v) During earth work if surface water found at site, the cost for dewatering through pumpset is deemed to be included in this rate.
M & L earth continuity conductor or main earthing lead fixed to wall / roof by dmc insulator through stainless steel screw or nut-bolt (as reqd basis) on any other indicated location for loop earthing etc with 20x3mm copper strip all as specified & directed. (Copper strips should be fixed on bridge insulator of 60 cm apart if reqd)
M & L earth continuity conductor or main earthing lead fixed to wall / roof by dmc insulator through stainless steel screw or nut-bolt (as reqd basis) on any other indicated location for loop earthing etc with 32x6mm copper strip all as specified & directed. (Copper strips should be fixed on bridge insulator of 60 cm apart if reqd)
S&F galvanized steel tubes of 40 mm bore light grade including all fittings like bend & socket and fixed on walls / ceilings / floors throgh MS clamp for earth strip protection or for installation of air termination rod complete all as specified and directed.
S&F galvanized steel tubes of 50 mm bore light grade including all fittings like bend & socket and fixed on walls / ceilings / floors throgh MS clamp for earth strip protection complete all as specified and directed.
S&F galvanized steel tubes of 80 mm bore light grade including all fittings like bend & socket and fixed on walls / ceilings / floors throgh MS clamp for earth strip protection complete all as specified and directed.
M&L for clamped joints (by overlapping the bars and applying clamps around the overlap) after brazing the jointing portion of the copper earthing strips of any types and sizes complete all as specified and directed.
M & L for test point terminal block made of gun metal for phosphorous bronze size 75 X 75 X 25 mm, drilled and screwed including 3 Nos. 8 mm dia 25 mm long hex head screw within halogen free weather proof IP-66 enclosure with one/ two nos mounting bracket all as specified and directed. Enclosure Make - Hensel/ OBO (The test point should be 1.0 mtr above ground level)
S&F single, pointed air termination copper rod (12mm dia and 300 mm long), should be fixed through copper flat, clamp, riveting &brazing works on GI Pipe all as specified and directed by Engr-in-Charge.
M&L for PCC concrete 1:3:6 Type C-1 with 20mm graded aggregate for planting GI pipe for air termination rod or foundation or any others works incl. necessary formwork (as reqd) all as specified and directed.
M&L for PCC concrete 1:3;6 Type C-1 with 20mm graded aggregate for planting cable route indicator /foundation or any others work incl. necessary formwork (wherever reqd) all as specified and directed.
M&L for cable route indicator made up of precast RCC (1:2:4) type B1 (using 20mm graded stone aggregate) of size 300mm wide and 800mm height and 100 mm thick, install the same on ground by PCC works 1:3:6 Type C1 (size 310mmx150mmx300mm), engraved the words in capital letters of size 5cm height and 2cm width "AFLS CABLE " including rendering 10mm thick in CM (1:3) and two coats of weather coat paint over a coat of primer etc complete all as directed. Note : Installation of route indicator through earth & PCC works shall be measured and paid separately.
M&L for connection of 100KVA DG Set (Make - KOEL) with AMF Panel to the new Distribution Panel complete all as specified and directed
B/R PORTION
Surfaces dressing not exceeding 15 cm deep as in bearms of road, path etc as in soft/loose soil all as specified and directed
Excavation in trenches not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth and getting out in soft/loose soil all as specified and directed.
Material and labour for providing Plain Cement Concrete (1:4:8) type D2 using 40 mm graded aggregate as in foundation, filling and mass concrete all as specified and directed.
Material and labour for brick work with locally available sub class ‘B’, old size, best quality bricks, straight or curved on plan exc 6 m mean radius built in cement mortar ( 1:6) all as specified and directed.
Material and labour for 15 mm thick rendering in cement mortar (1:4) on fair face of brick or concrete surface finished even and fair all as specified.
Supply only integral water proofing compoud ISI marked.
M&L for soil filling under floor including raising (or lowering) earth, spreading in layers n exc 30 cm thick watering, ramming/rolling and finishing to revised size, shape, etc, n exc 1.5 m high from base all as directed.
Material and labour for providing 100 mm thick cement concrete (1:4:8) type D2 using 40 mm graded aggregate as in sub base of floor all as specified and directed.
Material and labour for providing 75 mm thick cement concrete (1:4:8) type D2 using 40 mm graded aggregate as in sub base of floor all as specified and directed.
Material and labour for providing 50 mm thick cement concrete (1:4:8) type D2 using 40 mm graded aggregate as in sub base of floor all as specified and directed.
Material and labour for providing 50mmthickcement concrete (1:2:4) type B1 using 20mm aggregate as in plinth protection surfaces even and smooth using extra cement all as specified and directed
Material and labour for providing hardcore of broken stone of gauge not exc. 63 mm deposited, spread and leveled in layers not exc. 15cm thick, watered and rammed to a true surface all as directed.
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ claddingto wall, fixed with self tapping screws complete all as specified and as directed..
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet for ridges of 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ claddingto wall, fixed with self tapping screws complete all as specified and as directed.
Excavation in post holes (or similar holes) each not exceeding 0.50 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering and removing surplus soil to a distance not exceeding 50 m and making good surfaces in soft/loose soil all as directed
Supply and fix steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161 – 1979 grade St – 240 all as specified and directed.
Supply and fix rolled mild steel in roof trusses (framed), trussed, purlins, cane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance piece, cleats conforming to Fe-410-W( Gde E-250)quality-A- etc including notching, drilling, fitting riveting or welding all as specified and directed
Supply and fix rolled mild steel in roof trusses (framed), trussed, purlins, cane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance piece, cleats conforming to Fe-410-W( Gde E-250)quality-A- etc including notching, drilling, fitting riveting or welding all as specified and directed
Returning, filling in trenches including spreading, leveling watering and ramming in layers not exceeding 25cm all as directed.
Removing of surplus soil not exceeding 50 m and deposited where directed at a level not exceeding 1.50m above the starting point all as directed.
Material and labour for preparation of new and previously un-treated steel surfaces of any description, not otherwise described over 10cmwidth or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer all as specified and directed.
Swastika Engineers and Agencies
M/S PANKAJ SUPPLY SYNDICATE
M/s Vishnu Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .