Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC MAIN STREET GONDER 35 VILL GONDER KARNAL HARYANA 132024 | KARNAL | KARNAL | HARYANA | 132024 | ₹1.7 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.7 Cr+₹3.0 L (1.77%)Rejected-Finance 0 0 RAMNAGAR FATEHPUR ROAD KADIRABAD GRAM BUDHWAL PARGANA AND TEHSIL RAMNAGAR BARABANKI UTTAR PRADESH 225202 | BARABANKI | UTTAR PRADESH | 225202 | ₹1.7 Cr+₹3.0 L (1.77%) | L2 | Rejected-Finance L2 |
| 3 | L3₹1.7 Cr+₹3.2 L (1.89%)Rejected-Finance 2 CORRIGENDUM ADDENDUM 01 DATED 11 01 2024 3 YOUR TENDER SUBMITTED ON 15 01 2024 ON E TENDER WEBSITE 4 CORRIGENDUM ADDENDUM 02 DATED 06 02 2024 5 YOUR PRICE BID OPENED ON 06 02 2024 ON E TENDER WEBSITE | ₹1.7 Cr+₹3.2 L (1.89%) | L3 | Rejected-Finance L3 |
| 4 | L4₹1.8 Cr+₹6.5 L (3.83%)Rejected-Finance P 27 1 RASHTRAGURU AVENUE DUM DUM KOLKATA 700028 | 24 PARAGANAS NORTH | WEST BENGAL | 700028 | ₹1.8 Cr+₹6.5 L (3.83%) | L4 | Rejected-Finance L4 |
| 5 | L5₹1.8 Cr+₹10.1 L (5.99%)Rejected-Finance 241 SWAMI NARAYAN NAGAR 1 OPP SWAMIVIVEKANA ASHRAM BEHIND HALAR HOUSE JAMNAGAR JAMNAGAR GUJARAT 361001 | JAMNAGAR | GUJARAT | 361001 | ₹1.8 Cr+₹10.1 L (5.99%) | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | Youngmen Traders L4 | DOSHI ELECTRIC ENGG. CO. L6 | ECS ENGINEERING PVT LTD L7 | S.L. ELECTROMECH PVT. LTD. L3 | Balaji Engineering L9 | RASS CONTRACTOR AND ENGINEERS L12 | K B CONTRACT (P) LTD L10 | Skyline Airconditioning Engineers Pvt. Ltd. L13 | Awasthi Electric Works L11 | Ascent Electrification Engineers L5 | Shiva Enterprises L2 | MS DS ASSOCIATES L14 | C R ELECTRICALS L8 | Pavee Construction L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00ESSENTIAL DISTRIBUTION LT PANEL:- Design, Supply, Installation, Testing and commissioning of cubicle type IP 42, MV TTA, Panel-type tested designed as per IEC 61439-1 &2, suitable for 415 V, 3 Phase, 4 wire 50 Hz AC supply, made out of 2 mm thick CRCA sheet for frame work, doors and covers, 3 mm thick for gland plates, dust tight, vermin proof, totally enclosed, floor mounting, free standing, extensible on both sides i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade , having 1000 Amps capacity FP Aluminium bus bars of high conductivity,DMC/SMC bus bar supports with short circuit withstand capacity of 35 KA for 1Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size to minimum 50 mm x 5 mm at the rear with 2 nos earth stud, 20% spare space of outgoings in Panel, solid connections from main bus bars to switch gears with required size of Aluminium bus bars and control wiring with 2.5 Sq.mm. FRLS PVC insulated copper conductor cable, cable alleys, cable gland plates suitable for indoor operation, complete with all accessories, connection, interconnection, earthing, including provision of SPD's. Surge Protection Devices (SPD’S) shall be provided at Sub Distribution LT Panel (Type 2 / Class C) i/c providing following switchgears /accessories as per specifications.etc., as required (Sub-Essential Panel at old Substation Room). | |||||||||||||||||
| 1.10(A) INCOMERS - 2 Nos and each incomer shall comprises of following i) 01 Nos. 800 A FP,Ics=Icu= 35KA at 440 V, MCCB with microprocessor based release having inbuilt adjustable Over current, Short Circuit and Earth Fault Protection with spreader links i/c extended rotary handle mechanism and LED indication lamps for ON/OFF/TRIP along with control MCB. ii) 01 Set Intelligent digital multi function meter of class 0.5 to read V,A, F, KVA, KW, KVAR, KWH, KVAH, PF, Hz etc with communication facility (RS485 port). LED display with required Nos CTs of suitable range,15 VA, class 0.5 and control circuit wiring along with control MCBs etc. iii) 1 no. 96 sqmm Digital Voltmeter, accuracy class 0.5 of suitable range along with inbuilt selector switch and suitable for 3 phase, 4 wire operation with LED display with built-in selector switch along with control MCBs etc. iv)1 set 96 sq mm Digital Type Ammeter of accuracy class 0.5 of suitable range along with inbuilt selector switch suitable for 3 phase 4 wire operation with LED / LCD display with 3 numbers of class 0.5 accuracy, 15 VA burden & suitable range CTs. v) 1 Set of LED type Indication Lamps, R,Y,B and breaker 'ON', 'OFF', 'TRIP' each protected with 2 Amp. SP MCB. | |||||||||||||||||
| 1.20(B)Bus Bars : - 1 set of high conductivity 4 pole (TPN) Aluminium bus bars of minimum 1000 Amps capacity having 100% neutral bus as that of phase bus with heat shrinkable coloured sleeves i/c DMC / SMC busbars supports at required intervals. The bus bar shall be extensible at both ends. (C)Bus coupler : - i) 01 Nos. 800 A FP,Ics=Icu= 35KA at 440 V, MCCB with microprocessor based release having inbuilt Adjustable Over current, Short Circuit, Earth Fault Protection with spreader links i/c extended rotary handle mechanism and LED indication lamps for ON and OFF protected with 2 A MCB. ii) 1 Set Indication Lamps, LED type 'ON' , 'OFF', 'TRIP' lamps protected along with control MCBs etc. | |||||||||||||||||
| 1.30(D)Electrical & Mechanical Interlocking between both incommers and bus coupler. (E) Outgoing i)04 Nos. 400 A FP,Ics=Icu= 35KA at 440 V, MCCB with microprocessor based release having inbuilt Adjustable Over current, Short Circuit & Earth Fault Protection with spreader links i/c extended rotary handle mechanism and LED indication lamps for ON/OFF/Trip protected along with control MCBs etc. ii) 02 Nos. 250 A FP,Ics=Icu= 35 KA at 440 V, MCCB with microprocessor based release having Over current, Short Circuit and Earth Fault Protection i/c terminal spreaders, extended rotary mechanism and LED indication lamp for ON /OFF/Trip protected along with control MCBs etc. iii) 02 Nos. 160A FP,Ics=Icu= 35 KA at 440 V, MCCB with microprocessor based release having Over current, Short Circuit & Earth Fault Protection i/c terminal spreaders, extended rotary mechanism and LED indication lamp for ON /OFF/Trip protected along with control MCBs etc. iv) 04 Nos. 100 A FP,Ics=Icu= 35 KA at 440 V, MCCB with microprocessor based release having Over current, Short Circuit, Earth Fault Protection i/c terminal spreaders, extended rotary mechanism and LED indication lamp for ON /OFF/Trip protected along with control MCBs etc.. | |||||||||||||||||
| 1.40 | v) 12 Sets of 96 sq mm Digital Type Ammeter of accuracy class 0.5 of suitable range along with inbuilt selector switch suitable for 3 phase 4 wire operation with LED / LCD display with 3 numbers of class 0.5 accuracy, 15 VA burden & suitable range CTs.
vi) 2No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up < 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by CE and ROHS.
Essential LT Panel complete comprises of above. (Sl. No. 1 to Sl. No. 1.4) | 1 | Job | 14,55,000 ₹14,55,000 | 14,57,000 ₹14,57,000 | 13,65,000 ₹13,65,000 | 12,33,354 ₹12,33,354 | 18,25,250 ₹18,25,250 | 15,00,000 ₹15,00,000 | 12,33,000 ₹12,33,000 | 10,00,000 ₹10,00,000 Lowest | 13,90,000 ₹13,90,000 | 15,00,000 ₹15,00,000 | 15,65,000 ₹15,65,000 | 17,75,025 ₹17,75,025 | 17,08,847 ₹17,08,847 | 16,50,000 ₹16,50,000 |
| 2.00NON-ESSENTIAL DISTRIBUTION LT PANEL:- Design, Supply, Installation, Testing and commissioning of cubicle type IP 42, TTA LT Panel-type tested designed as per IEC 61439-1 &2, suitable for 415 V, 3 Phase, 4 wire 50 Hz AC supply, made out of 2 mm thick CRCA sheet for frame work, doors and covers, 3 mm thick for gland plates, dust tight, vermin proof, totally enclosed, compartmentalised design, floor mounting/ Wall mounting, free standing, extensible on both sides i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade , having 500 Amps capacity FP Aluminium bus bars of high conductivity,DMC/SMC bus bar supports with short circuit withstand capacity of 35 KA for 1Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size as per IS 3043 subject to minimum 30 mm x 5 mm at the rear with 2 nos earth stud, 20% spare space of outgoings in Panel, solid connections from main bus bars to switch gears with required size of Aluminium bus bars and control wiring with 2.5 Sq.mm. FRLS PVC insulated copper conductor cable, cable alleys, cable gland plates suitable for indoor operation, complete with all accessories, connection, interconnection, earthing i/c providing following switchgears /accessories as per specifications.etc., as required (Sub-NOn Essential Panel at old Substation Room) | |||||||||||||||||
| 2.10(A) INCOMERS - 1 Nos and each incomer shall comprises of following i) 01 Nos. 400A FP,Ics=Icu= 35KA at 440 V, MCCB with microprocessor based release having inbuilt Adjustable Over current, Short Circuit, Earth Fault Protection with spreader links i/c extended rotary handle mechanism and LED indication lamps for ON /OFF/Trip protected along with control MCBs etc. ii) 01 Set Intelligent digital multi function meter of class 0.5 to read V,A, F, KVA, KW, KVAR, KWH, KVAH, PF, Hz etc with communication facility (RS485 port). LED display with required Nos CTs of suitable range,15 VA, class 0.5 and control circuit wiring protected along with control MCBs etc..2 Amp protection MCB. iii)1 no. 96 sqmm Digital Voltmeter, accuracy class 0.5 of suitable range along with inbuilt selector switch and suitable for 3 phase, 4 wire operation with LED display with built-in selector switch along with 3 nos. of 2 Amp SP protection MCBs. iv)1 set 96 sq mm Digital Type Ammeter of accuracy class 0.5 of suitable range along with inbuilt selector switch suitable for 3 phase 4 wire operation with LED / LCD display with 3 numbers of class 0.5 accuracy, 15 VA burden & suitable range CTs. (B) Bus Bars 1 set of high conductivity 4 pole (TPN) Aluminium bus bars of minimum 500 Amps capacity having 100% neutral bus as that of phase bus with heat shrinkable coloured sleeves i/c DMC / SMC busbars supports at required intervals. The bus bar shall be extensible at both ends. | |||||||||||||||||
| 2.20 | (C) Outgoing
i) 04 Nos. 250A FP,Ics=Icu= 35KA at 440 V, MCCB with microprocessor based release having inbuilt Adjustable Over current, Short Circuit, Earth Fault Protection with spreader links i/c extended rotary handle mechanism and LED indication lamps for ON and OFF protected with 2 A MCB.
ii) 02 Nos. 100 A FP,Ics=Icu= 25 KA at 440 V, MCCB with microprocessor based release having Over current, Short Circuit, Earth Fault Protection i/c terminal spreaders, extended rotary mechanism and LED indication lamp for ON and OFF protected with 2 A MCB.
iii) 06 Sets of 96 sq mm Digital Type Ammeter of accuracy class 0.5 of suitable range along with inbuilt selector switch suitable for 3 phase 4 wire operation with LED / LCD display with 3 numbers of class 0.5 accuracy, 15 VA burden & suitable range CTs.
iv) 06 Sets of LED type Indication Lamps, R,Y,B and breaker 'ON', 'OFF', 'TRIP' each protected with 2 Amp. SP MCB.
Non Essential LT Panel complete comprises of above. (Sl. No. 2 to Sl. No. 2.2) | 1 | Job | 4,60,000 ₹4,60,000 | 2,58,550 ₹2,58,550 | 3,86,000 ₹3,86,000 | 5,25,446 ₹5,25,446 | 4,45,000 ₹4,45,000 | 7,75,000 ₹7,75,000 | 5,12,100 ₹5,12,100 | 2,50,000 ₹2,50,000 Lowest | 5,10,000 ₹5,10,000 | 3,60,000 ₹3,60,000 | 6,15,000 ₹6,15,000 | 6,79,035 ₹6,79,035 | 5,60,867 ₹5,60,867 | 6,00,000 ₹6,00,000 |
| 3.00DISTRIBUTION LT PANEL T2 FIRST FLOOR:- Supply, Installation, Testing and Commissioning of cubicle type Essential Distribution TTA Indoor LT panel as per IEC 61439-1&2, IP42, suitable for 415V+/-10%, 3 Phase, 4 wire 50 Hz AC supply system, fabricated in 4b compartmentalized modular design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having TPN Aluminium alloy bus bars having100% neutral bus as that of phase bus supported with SMC bus bar supports, extensable at both side, with short circuit withstand capacity as per design subject to minimum 35 KA for 1 sec , bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common Copper earth bus bar of size as per IEC 61439/ IS 3043 subject to minimum 50 mm x 5 mm at the rear with 2 Nos. earth stud, solid / flexible connections from main earth bus bar to switchgears with required size of Cooper conductors / bus bars and control wiring with 2.5 sqmm FRLS PVC insulated copper conductor cable, cable alleys, cable gland plates in two halves and providing following switchgears / accessories as per specifications. | |||||||||||||||||
| 3.10(A) INCOMERS - 2 Nos and each incomer shall comprises of following i) 01 Nos. 400 A FP,Ics=Icu= 35KA at 440 V, MCCB with microprocessor based release having Adjustable Over current, Short Circuit, Earth Fault Protection i/c extended rotary mechanism and LED indication lamp for ON and OFF protected with 2 A MCB. ii) 01 Set Intelligent digital multi function meter of class 0.5 to read V,A, F, KVA, KW, KVAR, KWH, KVAH, PF, Hz etc with communication facility (RS485 port), THD and Individual order harmonics upto 31st Order. LED / LCD display with required Nos CTs of suitable range,15 VA, class 0.5 and control circuit wiring with 2 Amp protection MCB. iii) 1 no. 96 sqmm Digital Voltmeter, accuracy class 0.5 of suitable range along with inbuilt selector switch and suitable for 3 phase, 4 wire operation with LED / LCD display with built-in selector switch along with 3 nos. of 2 Amp SP protection MCBs. iv) 1 set 96 sq mm Digital Type Ammeter of accuracy class 0.5 of suitable range along with inbuilt selector switch suitable for 3 phase 4 wire operation with LED / LCD display with 3 numbers of class 0.5 accuracy, 15 VA burden & suitable range CTs. v) 1 Set of LED type Indication Lamps, R,Y,B and breaker 'ON', 'OFF', 'TRIP' each protected with 2 Amp. SP MCB. | |||||||||||||||||
Tender Value
₹2.3 Cr
EMD Value
₹6.9 L
Closing Date
14 Nov 2025, 6:00 pmClosed
AGM (E-E)
O/o DGM (E-E), 3rd floor, Office of Airport Director-AAI, B.P.I Airport, Bhubaneswar.
Provision / Augmentation of power supply system including LT panels and cables etc. at B.P.I Airport, Bhubaneswar.
2025_AAI_253303_1
AAI/BBSR/DGM(E-E)/NIT-10/2025
Open Tender
Electrical Works
Works
240 days
BPI Airport, Bhubaneswar
Please refer Tender documents.
13 documents required · 13 mandatory
₹1,180
₹6.9 L
BPI Airport, Bhubaneswar
14 Mar 2026
24 Oct 2025
17 Nov 2025
25 Oct 2025
14 Nov 2025
25 Oct 2025
25 Oct 2025 - 31 Oct 2025
27 Oct 2025
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1ESSENTIAL DISTRIBUTION LT PANEL:- Design, Supply, Installation, Testing and commissioning of cubicle type IP 42, MV TTA, Panel-type tested designed as per IEC 61439-1 &2, suitable for 415 V, 3 Phase, 4 wire 50 Hz AC supply, made out of 2 mm thick CRCA sheet for frame work, doors and covers, 3 mm thick for gland plates, dust tight, vermin proof, totally enclosed, floor mounting, free standing, extensible on both sides i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade , having 1000 Amps capacity FP Aluminium bus bars of high conductivity,DMC/SMC bus bar supports with short circuit withstand capacity of 35 KA for 1Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size to minimum 50 mm x 5 mm at the rear with 2 nos earth stud, 20% spare space of outgoings in Panel, solid connections from main bus bars to switch gears with required size of Aluminium bus bars and control wiring with 2.5 Sq.mm. FRLS PVC insulated copper conductor cable, cable alleys, cable gland plates suitable for indoor operation, complete with all accessories, connection, interconnection, earthing, including provision of SPD's. Surge Protection Devices (SPD’S) shall be provided at Sub Distribution LT Panel (Type 2 / Class C) i/c providing following switchgears /accessories as per specifications.etc., as required (Sub-Essential Panel at old Substation Room). | |||||
| 1.1 | (A) INCOMERS - 2 Nos and each incomer shall comprises of following
i) 01 Nos. 800 A FP,Ics=Icu= 35KA at 440 V, MCCB with microprocessor based release having inbuilt adjustable Over current, Short Circuit and Earth Fault Protection with spreader links i/c extended rotary handle mechanism and LED indication lamps for ON/OFF/TRIP along with control MCB.
ii) 01 Set Intelligent digital multi function meter of class 0.5 to read V,A, F, KVA, KW, KVAR, KWH, KVAH, PF, Hz etc with communication facility (RS485 port). LED display with required Nos CTs of suitable range,15 VA, class 0.5 and control circuit wiring along with control MCBs etc.
iii) 1 no. 96 sqmm Digital Voltmeter, accuracy class 0.5 of suitable range along with inbuilt selector switch and suitable for 3 phase, 4 wire operation with LED display with built-in selector switch along with control MCBs etc.
iv)1 set 96 sq mm Digital Type Ammeter of accuracy class 0.5 of suitable range along with inbuilt selector switch suitable for 3 phase 4 wire operation with LED / LCD display with 3 numbers of class 0.5 accuracy, 15 VA burden & suitable range CTs.
v) 1 Set of LED type Indication Lamps, R,Y,B and breaker 'ON', 'OFF', 'TRIP' each protected with 2 Amp. SP MCB. | - | - | - | - |
| 1.2 | (B)Bus Bars : -
1 set of high conductivity 4 pole (TPN) Aluminium bus bars of minimum 1000 Amps capacity having 100% neutral bus as that of phase bus with heat shrinkable coloured sleeves i/c DMC / SMC busbars supports at required intervals. The bus bar shall be extensible at both ends.
(C)Bus coupler : -
i) 01 Nos. 800 A FP,Ics=Icu= 35KA at 440 V, MCCB with microprocessor based release having inbuilt Adjustable Over current, Short Circuit, Earth Fault Protection with spreader links i/c extended rotary handle mechanism and LED indication lamps for ON and OFF protected with 2 A MCB.
ii) 1 Set Indication Lamps, LED type 'ON' , 'OFF', 'TRIP' lamps protected along with control MCBs etc. | - | - | - | - |
| 1.3 | (D)Electrical & Mechanical Interlocking between both incommers and bus coupler.
(E) Outgoing
i)04 Nos. 400 A FP,Ics=Icu= 35KA at 440 V, MCCB with microprocessor based release having inbuilt Adjustable Over current, Short Circuit & Earth Fault Protection with spreader links i/c extended rotary handle mechanism and LED indication lamps for ON/OFF/Trip protected along with control MCBs etc.
ii) 02 Nos. 250 A FP,Ics=Icu= 35 KA at 440 V, MCCB with microprocessor based release having Over current, Short Circuit and Earth Fault Protection i/c terminal spreaders, extended rotary mechanism and LED indication lamp for ON /OFF/Trip protected along with control MCBs etc.
iii) 02 Nos. 160A FP,Ics=Icu= 35 KA at 440 V, MCCB with microprocessor based release having Over current, Short Circuit & Earth Fault Protection i/c terminal spreaders, extended rotary mechanism and LED indication lamp for ON /OFF/Trip protected along with control MCBs etc.
iv) 04 Nos. 100 A FP,Ics=Icu= 35 KA at 440 V, MCCB with microprocessor based release having Over current, Short Circuit, Earth Fault Protection i/c terminal spreaders, extended rotary mechanism and LED indication lamp for ON /OFF/Trip protected along with control MCBs etc.. | - | - | - | - |
| 1.4 | v) 12 Sets of 96 sq mm Digital Type Ammeter of accuracy class 0.5 of suitable range along with inbuilt selector switch suitable for 3 phase 4 wire operation with LED / LCD display with 3 numbers of class 0.5 accuracy, 15 VA burden & suitable range CTs.
vi) 2No Surge protection device Type 2 ( Class C), 4 Mode, MOV type suitable for 8/ 20µs surge,Voltage Protection level Up < 1.8kV, Operating Temperature -40 deg 'c' - +80 deg 'C', Connected Between 3Nos. phase to neutral and 1Nos. neutral to earth with discharge Current Imax. ≥ 40KA Per mode & In ≥ 20kA per Mode. SPD with 63A 4P HRC fuses of 100kA breaking capacity. For connecting SPD minimum 10sqmm copper wire must be used & length of connecting leads shall not be more than 500mm for per mode connection with each busbar including all necessary accessories. The SPD shall complience with IEC 61643-11 and certified by CE and ROHS.
Essential LT Panel complete comprises of above. (Sl. No. 1 to Sl. No. 1.4) | 1 | Job | - | - |
| 2NON-ESSENTIAL DISTRIBUTION LT PANEL:- Design, Supply, Installation, Testing and commissioning of cubicle type IP 42, TTA LT Panel-type tested designed as per IEC 61439-1 &2, suitable for 415 V, 3 Phase, 4 wire 50 Hz AC supply, made out of 2 mm thick CRCA sheet for frame work, doors and covers, 3 mm thick for gland plates, dust tight, vermin proof, totally enclosed, compartmentalised design, floor mounting/ Wall mounting, free standing, extensible on both sides i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade , having 500 Amps capacity FP Aluminium bus bars of high conductivity,DMC/SMC bus bar supports with short circuit withstand capacity of 35 KA for 1Sec., bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size as per IS 3043 subject to minimum 30 mm x 5 mm at the rear with 2 nos earth stud, 20% spare space of outgoings in Panel, solid connections from main bus bars to switch gears with required size of Aluminium bus bars and control wiring with 2.5 Sq.mm. FRLS PVC insulated copper conductor cable, cable alleys, cable gland plates suitable for indoor operation, complete with all accessories, connection, interconnection, earthing i/c providing following switchgears /accessories as per specifications.etc., as required (Sub-NOn Essential Panel at old Substation Room) | |||||
| 2.1 | (A) INCOMERS - 1 Nos and each incomer shall comprises of following
i) 01 Nos. 400A FP,Ics=Icu= 35KA at 440 V, MCCB with microprocessor based release having inbuilt Adjustable Over current, Short Circuit, Earth Fault Protection with spreader links i/c extended rotary handle mechanism and LED indication lamps for ON /OFF/Trip protected along with control MCBs etc.
ii) 01 Set Intelligent digital multi function meter of class 0.5 to read V,A, F, KVA, KW, KVAR, KWH, KVAH, PF, Hz etc with communication facility (RS485 port). LED display with required Nos CTs of suitable range,15 VA, class 0.5 and control circuit wiring protected along with control MCBs etc..2 Amp protection MCB.
iii)1 no. 96 sqmm Digital Voltmeter, accuracy class 0.5 of suitable range along with inbuilt selector switch and suitable for 3 phase, 4 wire operation with LED display with built-in selector switch along with 3 nos. of 2 Amp SP protection MCBs.
iv)1 set 96 sq mm Digital Type Ammeter of accuracy class 0.5 of suitable range along with inbuilt selector switch suitable for 3 phase 4 wire operation with LED / LCD display with 3 numbers of class 0.5 accuracy, 15 VA burden & suitable range CTs.
(B) Bus Bars
1 set of high conductivity 4 pole (TPN) Aluminium bus bars of minimum 500 Amps capacity having 100% neutral bus as that of phase bus with heat shrinkable coloured sleeves i/c DMC / SMC busbars supports at required intervals. The bus bar shall be extensible at both ends. | - | - | - | - |
| 2.2 | (C) Outgoing
i) 04 Nos. 250A FP,Ics=Icu= 35KA at 440 V, MCCB with microprocessor based release having inbuilt Adjustable Over current, Short Circuit, Earth Fault Protection with spreader links i/c extended rotary handle mechanism and LED indication lamps for ON and OFF protected with 2 A MCB.
ii) 02 Nos. 100 A FP,Ics=Icu= 25 KA at 440 V, MCCB with microprocessor based release having Over current, Short Circuit, Earth Fault Protection i/c terminal spreaders, extended rotary mechanism and LED indication lamp for ON and OFF protected with 2 A MCB.
iii) 06 Sets of 96 sq mm Digital Type Ammeter of accuracy class 0.5 of suitable range along with inbuilt selector switch suitable for 3 phase 4 wire operation with LED / LCD display with 3 numbers of class 0.5 accuracy, 15 VA burden & suitable range CTs.
iv) 06 Sets of LED type Indication Lamps, R,Y,B and breaker 'ON', 'OFF', 'TRIP' each protected with 2 Amp. SP MCB.
Non Essential LT Panel complete comprises of above. (Sl. No. 2 to Sl. No. 2.2) | 1 | Job | - | - |
| 3DISTRIBUTION LT PANEL T2 FIRST FLOOR:- Supply, Installation, Testing and Commissioning of cubicle type Essential Distribution TTA Indoor LT panel as per IEC 61439-1&2, IP42, suitable for 415V+/-10%, 3 Phase, 4 wire 50 Hz AC supply system, fabricated in 4b compartmentalized modular design from CRCA sheet steel of 2 mm thick for frame work and covers, 3 mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having TPN Aluminium alloy bus bars having100% neutral bus as that of phase bus supported with SMC bus bar supports, extensable at both side, with short circuit withstand capacity as per design subject to minimum 35 KA for 1 sec , bottom base channel of MS section not less than 100 mm x 50 mm x 5 mm thick, fabrication shall be done in transportable sections, entire panel shall have a common Copper earth bus bar of size as per IEC 61439/ IS 3043 subject to minimum 50 mm x 5 mm at the rear with 2 Nos. earth stud, solid / flexible connections from main earth bus bar to switchgears with required size of Cooper conductors / bus bars and control wiring with 2.5 sqmm FRLS PVC insulated copper conductor cable, cable alleys, cable gland plates in two halves and providing following switchgears / accessories as per specifications. | |||||
| 3.1 | (A) INCOMERS - 2 Nos and each incomer shall comprises of following
i) 01 Nos. 400 A FP,Ics=Icu= 35KA at 440 V, MCCB with microprocessor based release having Adjustable Over current, Short Circuit, Earth Fault Protection i/c extended rotary mechanism and LED indication lamp for ON and OFF protected with 2 A MCB.
ii) 01 Set Intelligent digital multi function meter of class 0.5 to read V,A, F, KVA, KW, KVAR, KWH, KVAH, PF, Hz etc with communication facility (RS485 port), THD and Individual order harmonics upto 31st Order. LED / LCD display with required Nos CTs of suitable range,15 VA, class 0.5 and control circuit wiring with 2 Amp protection MCB.
iii) 1 no. 96 sqmm Digital Voltmeter, accuracy class 0.5 of suitable range along with inbuilt selector switch and suitable for 3 phase, 4 wire operation with LED / LCD display with built-in selector switch along with 3 nos. of 2 Amp SP protection MCBs.
iv) 1 set 96 sq mm Digital Type Ammeter of accuracy class 0.5 of suitable range along with inbuilt selector switch suitable for 3 phase 4 wire operation with LED / LCD display with 3 numbers of class 0.5 accuracy, 15 VA burden & suitable range CTs.
v) 1 Set of LED type Indication Lamps, R,Y,B and breaker 'ON', 'OFF', 'TRIP' each protected with 2 Amp. SP MCB. | - | - | - | - |
stage.html
html • 0.08 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Tender Documents
Tender Documents • 12.05 MB
BOQ_291314.xls
BOQ • 0.38 MB
TenderDoc.pdf
Tender Documents • 12.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .