| 1 | L1₹12.7 LAccepted-AOC H NO 273 VPO SURHERA WEST DELHI 110043 | WEST DELHI | DELHI | 110043 | ₹12.7 L | L1 | Accepted-AOC Accepted being lowest on 30 Jul 2020 |
| 2 | L2₹15.1 L+₹2.4 L (19.0%)Rejected-Finance CHANDPURA TIKAMGARH DIST TIKAMGARH MP | TIKAMGARH | TIKAMGARH | MADHYA PRADESH | ₹15.1 L+₹2.4 L (19.0%) | L2 | Rejected-Finance Rejected |
| 3 | L3₹16.0 L+₹3.3 L (26.3%)Rejected-Finance | ₹16.0 L+₹3.3 L (26.3%) | L3 | Rejected-Finance Rejected |
| 4 | L4₹16.7 L+₹4.0 L (31.5%)Rejected-Finance C O OPPOSITE BDO OFFICE MANDA AKHNOOR DISTT JAMMU PIN 181201 | JAMMU | JAMMU AND KASHMIR | 181201 | ₹16.7 L+₹4.0 L (31.5%) | L4 | Rejected-Finance Rejected |
| 5 | L5₹17.4 L+₹4.7 L (37.1%)Rejected-Finance | ₹17.4 L+₹4.7 L (37.1%) | L5 | Rejected-Finance Rejected |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
17 Jul 2020, 6:00 pmClosed
GE Faridkot
GE Faridkot-151203 Punjab
Repair/Replacement of summer appliances, Refrigerator, Deep Freezer and fitting with element (Solar heating system geysers) and Misc E/M works for use by DEL at Faridkot Mil Stn
2020_MES_354004_1
GE FRD-31/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Faridkot Mil Stn
Class E Category b i
8 documents required · 8 mandatory
₹500
GE Faridkot
₹40,000
Yes
14 Aug 2020
19 Jun 2020
20 Jul 2020
19 Jun 2020
17 Jul 2020
3 Jul 2020
Amount
Taking down unserviceable sealed compressor of any make/model of Water Cooler and Supply & fixing and installation new sealed unit compressor hermetically sealed, suitable for water cooler 150 /150 Ltrs capacity including cleaning, vaccumizing, gas charging of adequate qty with testing on load, complete all as specified and directed by Engineer in Charge. Make : Kirloskar/Sriram
All as per Ser Item No 01 here in before but sealed unit compressor suitable for water cooler capacity 60/120 Ltrs, complete all as specified and directed by Engineer in Charge. Make : Kirloskar/Sriram
All as per Ser Item No 01 here in before but sealed unit compressor suitable for water cooler capacity 40/80 Ltrs, complete all as specified and directed by Engineer in Charge. Make : Kirloskar/Sriram
Supply and fixing in replacement Water taps brass chromium plated heavy duty for 15mm bore pipe, all as specified and directed by Engineer in Charge. Make : Jindal/Johnson.
Supply and fixing in replacement of Fan motor of capacity 1/35/50 HP, 1400 RPM, 230 volts AC complete all as specified and directed by Engineer in Charge. Make : Danfoss/ Ranutrol/ Anapurna.
Material and labour for charging of refrigerant gas in water cooler of capacity 150/150 ltrs, 60/120 ltrs and 40/80 ltrs including pressure/ load testing etc complete all as specified and directed by Engineer in Charge.
Taking down unserviceable compressor sealed unit of any make/model of ACs and Supply, fixing and installation of (sealed unit) compressor hermetically suitable for 1.5 TR window type AC complete including charging of refrigerant gas in the unit , Relay,Starting capacitor, Running capacitor and over load protector and soldering/ brazing of suction and discharge pipes, complete all as specified and directed by Engineer in Charge. Make : Gujral/Carrier/Voltas/Sidhwal
All as per Ser Item No 07 here in before but suitable for split type AC of 2.0 Ton complete all as specified and directed by Engineer in Charge.
All as per Ser Item No 07 here in before but suitable for split type AC of 1.5 Ton complete all as specified and directed by Engineer in Charge.
Servicing and maintenance of AC's window type/split type of any make with acid for cleaning of condenser and evaporated coil, complete all as specified and directed by Engineer in Charge.
S&F in replacement of Double shaft motor 1/5 HP blower motor 240 volts single phase AC supply complete all as specified and directed by Engineer in Charge Make : Khaitan/Universal/CG./Carrier/Voltas/Sidhwal.
Supply and fixing in replacement of PVC Blower fan suitable for window /split type AC of capacity 1.5 Ton complete all as specified and directed by Engineer in Charge.
M&L for charging of refrigerant gas in Window type & Split type AC 1.5/2.0 Ton capacity including pressure/leak testing etc complete all as specified and directed by Engineer in Charge. Make : Voltas/Blue Star. .
Supply & fixing indoor unit of split type AC of capacity 1.5/2.0 ton including cooling coils and connecting items, complete all as specified and directed by Engineer in Charge. Make : Voltas/Blue Star/Gujral/LG
All as per srl item No. 14 here-in-before but out door unit including compressor and connected items, such as condensor coil, compressor, fan motor, fan blade and all electric work complete all as specified and directed by Engineer in Charge. Make : Voltas/ Blue Star/Gujral/LG
S&F PCB remote plate of AC split type 1.5 Ton/2 Ton with remote, complete all as specified and directed by Engineer in Charge. Make of Split-Type ACs- LG/Voltas/Sidwal/Carrier/Videocon
Taking down unserviceable Compressor sealed unit of refrigerator any capacity make/model and S&F new hermtically sealed Compressor suitable for 286/310 Ltrs capacity Refrigerator including accessories and vaccumizing, gas charging of adequate qty in the unit and soldering /brazing of suction and discharge pipe complete all as specified and directed by Engineer in Charge. Make : Kirloskar/ Teecum Shah/Sriram/Godrej/Samsung/Whirlpool
All as per Ser Item No 17 here in before but for 165/175 Ltrs capacity refrigerator complete all as specified and directed by Engineer in Charge.
M&L for charging of refrigerant gas in Refrigerator of any size including pressure/leak testing etc complete all as specified and directed by Engineer in Charge.
Supply & fixing cooling coil of Refrigerator capacity 280/310 ltrs including connected works complete all as specified and directed by Engineer in Charge.
S&F new hermetically sealed Compressor suitable for Deep Freezer of capacity 500 Ltrs complete including accessories and cleaning, vaccumizing, gas charging of adequate qty in the unit and soldering/ brazing of suction and discharge pipes complete all as specified and directed by Engineer in Charge. Make : Kirloskar/Teecum Shah/Sriram
All as per Ser Item No 21 here in before but for 200/300 Ltrs capacity Deep Freezer complete all as specified and directed by Engineer in Charge.
M&L for charging of refrigerant gas in Deep Freezer of any size including pressure/leak testing etc complete all as specified and directed by Engineer in Charge.
Supply and replacement of Fan motor of capacity 1/8 HP, 1400 RPM, three speed suitable for desert cooler complete all as specified and directed by Engineer in Charge. Make : Universal/Khaitan/CG
Replacement of submersible water pump (Tullu pump) for desert cooler with water protection cap complete single phase AC 230 V complete all as specified and directed by Engineer in Charge. Make : Universal/Khaitan/CG
Supply and fixing Wood wool pad for desert cooler of any type complete set of three superior quality as approved by Engineer in Charge.
Removing old paint of Desert Cooler internally and externally, preparing new galvanised surface for painting and applying two coats of synthetic enamel paint over a coat of red oxide primer using spray gun complete all as specified and directed by Engineer in Charge
Replacement outer body of desert cooler of standard size made of 2mm thick GI sheet including side shutters, legs and front grill complete all as specified and directed by Engineer in Charge
Material and Labour for repairs and descalling of solar water heating system of capacity 500/300/200 ltrs by disconnecting all electrical connection, dismantling its parts at site and replacement of gasket from joints, elbows, nipples, pipes and insulation of pipes with glass wool and reassembling, refixing at site, making all electrical connection, testing and commissioning complete all as specified and directed by Engineer in Charge.
S & F Repair/ replacement of solar water heating element 2/3 KW thread type complete all as specified and directed by Engineer in Charge. Make : Dass Pass/Bajaj or equivelant
Repair/ replacement of Geyser inner tank of capacity 25 ltrs including inner assembly, nut bolts, rubber sheets, heating element, phase indicator and connected items after repair of geyser refixing at site making all electricals connection, testing and commissioning complete all as specified and directed by Engineer in Charge.
Repair/ replacement of Geyser outer body of capacity 25 ltrs including glass wool and connecting items complete all as specified and directed by Engineer in Charge.
Repair/ replacement of Geyser inner tank of capacity 50 ltrs including inner assembly, nut bolts, rubber sheets, heating element, phase indicator and connected items after repair of geyser refixing at site making all electricals connection, testing and commissioning complete all as specified and directed by Engineer in Charge.
Repair/ replacement of Geyser outer body of capacity 50 ltrs including connecting items complete all as specified and directed by Engineer in Charge.
M & L for repair of automatic voltage stablizers of capacity 2 KVA/ 3KVA/5 KVA single phase with replacement of Auto cut relays and PCB circuit and rewinding of transformer as required to make it functional after repair and testing on full load complete all as specified and directed by Engineer in Charge
Repair/replacement of filter, memron, pump and connected material and servicing of RO System complete all as specified and directed by Engineer in Charge
Replacement of solar panel of capacity 100/200/300/500 Ltrs and connected items i.e. heating element with thermostate, rubber gasket, elbow, nipple etc complete all as specified and directed by Engineer in Charge.
Supply & Fixing Running capacitor 10 to 20 Mfd for water cooler and deep freezer complete all as specified and directed by Engineer in Charge. Make : Bhel/Keltron/Tibeon.
Supply & Fixing starting capacitor 60-80 Mfd for water cooler and deep freezer complete all as specified and directed by Engineer in Charge. Make : Bhel/Keltron/Tibeon.
Supply & Fixing starting capacitor 100-120 Mfd for AC complete all as specified and directed by Engineer in Charge. Make : Bhel/Keltron/Tibeon.
Supply & Fixing starting capacitor 4 Mfd for AC complete all as specified and directed by Engineer in Charge. Make : Bhel/Keltron/Tibeon.
Supply & Fixing Over load protector of Acs/water coolers/deep freezers different model K-706502/7332/K-3/7015920B2/T-0072/K-7065B for Deep Freezer and water cooler complete all as specified and directed by Engineer in Charge
Supply & Fixing Thermostats switch (thin below) type for ACs/Water cooler / deep freezers /refrigerator complete all as specified and directed by Engineer in Charge. Make : Danfoss /Renutrol
Supply only brass float valves, high pressure, with polythene float and flynut complete screwed for iron pipe or brass ferrule of size 15mm bore complete all as specified and directed by Engineer in Charge.
Supply only Running Capacitor 36 MFD complete all as specified and directed by Engineer in Charge. Make: Seimens/Kaltron/Tibcon/
Supply & Fixing Starting Relay Model No 1062 for AC's complete all as specified and directed by Engineer in Charge. Make : Renutrol or equivalent in Shriram
Supply & Fixing Condenser fan suitable for window/split type ACs as per existing size complete all as approved by Engineer in Charge.
Supply & Fixing Running capacitor 45/50 MFD complete all as specified and directed by Engineer in Charge. Make : Bhel/Keltron/Tibeon.
Supply & Fixing Biometal fuse for referigerator complete all as specified and directed by Engineer in Charge.Make : Whirlpool/ Godrej/ LG
Supply & Fixing timer complete all as specified and directed by Engineer in Charge. Make : Whirlpool/ Godrej/LG
Supply & Fixing PVC (flexible) pipe for 15mm for desert cooler complete all as specified and directed by Engineer in Charge.
Supply & Fixing metal clad industrial Plug 2 Pole + earth 250 volts for Acs & geyser complete all as specified and directed by Engineer in Charge. Make : Indo Asian / Havells
Supply & Fixing metal clad industrial socket 2 Pole + earth 250 volts for Acs & geyser complete all as specified and directed by Engineer in Charge. Make : Indo Asian/ Havells
Supply & Fixing water distributor for desert cooler of size 1/2" (ISI mark) complete all as specified and directed by Engineer in Charge.
Supply & Fixing elbow (PVC) for desert cooler of size 1/2" (ISI mark) complete all as specified and directed by Engineer in Charge.
Supply & Fixing PVC connection 15mm bore and 300mm length for connecting main pipe line of hot water type with brass nuts complete all as specified and directed by Engineer in Charge. Make : Laser
Supply & Fixing PVC connection 15mm bore and 300mm length for connecting main pipe line of cold water type with PTMT nuts complete all as specified and directed by Engineer in Charge. Make : Laser
Supply & Fixing heating element 1.5 KW traingle type complete all as specified and directed by Engineer in Charge. Make : Das pass/Racold/Bajaj
Supply & Fixing heating element 1.5 KW round type complete all as specified and directed by Engineer in Charge. Make : Das pass/Racold/Bajaj
Supply & Fixing heating element 1.5 KW banana type complete all as specified and directed by Engineer in Charge. Make : Das pass/Racold/Bajaj
Supply & Fixing thermostate for geyser element/solar element complete all as specified and directed by Engineer in Charge.
Supply & Fixing 3 pin triangular plug top 6 Amp, 240 volts Cat No. 68 complete all as specified and directed by Engineer in Charge. Make : Fine/SSK
Supply & Fixing PVC insulated and FRLSH sheathed circular flexible, multi stranded copper cable 3 core of size 30/0.75 (2.5 sqmm) complete all as specified and directed by Engineer in Charge. Make : Kalinga/ Havells/ Plaza
Supply & Fixing PVC insulated and FRLSH sheathed circular flexible, multi stranded copper cable 3 core of size 30/0.25 (1.5 sqmm) complete all as specified and directed by Engineer in Charge. Make : Kalinga/ Havells/ Plaza
Supply & Fixing sheet metal enclosure wih socket plug top and MCBs 20 Amp single pole (AC box) complete all as specified and directed by Engineer in Charge. Make : Indo Asian/ Havells
Supply & Fixing frost free fan motor copper winding single phase, 250 volts, 50 Hz for double door refrigerator complete all as specified and directed by Engineer in Charge.
Supply & Fixing Fan blade for frost free motor for double door refrigerator as per sample complete all as specified and directed by Engineer in Charge.
Supply & Fixing fruit tray for double door refrigerator of capacity 310 ltrs as per sample complete all as specified and directed by Engineer in Charge.
Supply & Fixing shelf for double door refrigerator of capacity 310 ltrs as per sample complete all as specified and directed by Engineer in Charge.
Supply & Fixing geyser assemble nine (09) holes brass type including rubber gasket and safety valve complete all as specified and directed by Engineer in Charge. Make : Dass pas/Racold/Bajaj
Supply only geyser assemble six (06) holes (brass type) including rubber gasket and safety valve and connected items complete all as specified and directed by Engineer in Charge. Make : Dass pas/Racold/Bajaj Note :- A Sum of Rs. 1,12,312.00 will be deducted on account of credit for dismantling/ demolished/ taking down material. Please refer detail on srl page No. 21 (Schedule of credit) of Tender Documents.
POOJA CONSTRUCTION COMPANY
BHARAT BHUSHAN CONTRACTOR
DEEPAK ENTERPRISES
NEW AMRITSAR CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .