Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC SAIDAKADAL SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹36.5 L+₹2.9 L (8.54%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹38.0 L+₹4.3 L (12.9%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹40.5 L+₹6.8 L (20.3%)Rejected-Finance PHAYANG GOMPA COMPLEX AGLING ROAD SKALZANGLING LEH LADAKH J K 194101 | LEH | LEH | LADAKH | 194101 | L4 | Rejected-Finance Other than lowest bidder |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
1 May 2024, 6:00 pmClosed
GE 860 EWS
GE 860 EWS Karu Pin-194201
SERVICING MAINTENANCE REPLACEMENT OF FUEL FILTER V BELT OIL FILTER AND ALLIED WORK SERVICES OF DG SETS AT KARU ZONE II AND CAPTIVE REPAIRS TO VARIOUS DG SETS AND REPLACEMENT OF MINOR PARTS PANELS AND MISC WORKS AT KIARI CHUMATHANG AND NYOMA AREA
2024_MES_649232_1
8142/2024-25/E8
Open Tender
Civil Works
Item Rate
270 days
GE 860 EWS
As per tender documents
9 documents required · 9 mandatory
₹500
GE 860 EWS Karu
₹98,000
Yes
15 Jun 2024
4 Apr 2024
3 May 2024
4 Apr 2024
1 May 2024
18 Apr 2024
Amount
M&L for Checking, Inspection, maintanance and servicing complete including replacement of unserviceable spare parts of the DG set (comprising of Engine/ Alternator/ Control panel) of the following capacity for smoth functioning complete all as per manufacturers instructions and all as directed by Engr- in- Charge :- (a) Checking of all the nut bolts of engine and alternator (b) Checking of all belts and adjust the tension properly (c) Cleaning of air filters (d) Checking and readjusting the valve clearance (e) Change of Oil/Fuel filters and engine oil if necessary (f) checking the function of AVR genaral checks (g) Checking of control panel meters and gadgets function NOTE: (1) Cost of Spare parts required will be paid and measured separately (2) Servicing/routine check up carried out through authorised service centre of manufacturer (3) Make of spare recommendation by auth service centre of manufacturer. (4) 'B' checl will be carried out after every 250 runnign Hrs of of DG set or as and when required or directed by Engr-in-charhge (5) Contractor has to depute DG mechanic/technician as and when servicing of DG sets is due and as and when any DG set become unserviceable within 48 Hrs or as directed by Engr-in-charge . In case of failure a recovery of 5000 will be charged for non addressing the complaint of DG set within the given time
1010 KVA DG Set Make : Cummins
250 KVA DG Set Make : CG
160 KVA DG Set Make : Kirloskar
100/125 KVA DG Set Make : Kirloskar
82.5 KVA DG Set Make : Cummins
30/40 KVA DG set Make : Kirloskar
S&F in replacement of Air Cleaner Element (inner & outer) suitable for following capacity of DG Set. Air cleaner will be changed after every 500 hrs or when reqd complete all as specified and directed.Make MICO/Sakura/ Fleetguard
1010 KVA DG Set Make : Cummins
250 KVA DG Set Make : CG
160 KVA DG Set Make : Kirloskar
100/125 KVA DG Set Make : Kirloskar
82.5 KVA DG Set Make : Cummins
30/40 KVA DG set Make : Kirloskar
S&F in replacement of Fuel filter Element (Primary & Secondary and By Pass) for following capacity of DG Set:(Fuel filter will be changed after every 250 hrs or when reqd) complete all as specified and directed.
1010 KVA DG Set Make : Cummins
250 KVA DG Set Make : CG
160 KVA DG Set Make : Kirloskar
100/125 KVA DG Set Make : Kirloskar
82.5 KVA DG Set Make : Cummins
30/40 KVA DG set Make : Kirloskar
S&F in replacement of Lub Oil Filter Element for DG Sets of following capacity (Lub oil filter will be changed after every 250 hrs or when reqd) complete all as specified and directed .
1010 KVA DG Set Make : Cummins
250 KVA DG Set Make : CG
160 KVA DG Set Make : Kirloskar
100/125 KVA DG Set Make : Kirloskar
82.5 KVA DG Set Make : Cummins
30/40 KVA DG set Make : Kirloskar
S&F in replacement of ‘V’ belt suitable for alternator of following capacity of DG Sets complete all as directed by Engr in Charge:-
1010 KVA DG Set Make : Cummins
250 KVA DG Set Make : CG
160 KVA DG Set Make : Kirloskar
100/125 KVA DG Set Make : Kirloskar
82.5 KVA DG Set Make : Cummins
30/40 KVA DG set Make : Kirloskar
Replacement of 'V' belt for radiator/water pump suitable for following capacity DG Sets complete all as specified and directed by Engr-in-Charge. Make- Kirloskar/Cummins/Greaves
1010 KVA DG Set Make : Cummins
250 KVA DG Set Make : CG
160 KVA DG Set Make : Kirloskar
100/125 KVA DG Set Make : Kirloskar
82.5 KVA DG Set Make : Cummins
30/40 KVA DG set Make : Kirloskar
Replacement of fuel pipe with banjo bolt at both side suitable for following capacity DG sets complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set Make : Cummins
250 KVA DG Set Make : CG
160 KVA DG Set Make : Kirloskar
100/125 KVA DG Set Make : Kirloskar
82.5 KVA DG Set Make : Cummins
30/40 KVA DG set Make : Kirloskar
Repair of Dynamo/Alternator Assy for following capacity DG Set complete all as specified and directed by Engr-in-Charge.
200 KVA DG Set Make : Kirloskar
250 KVA DG Set Make : CG
160 KVA DG Set Make : Kirloskar
100/125 KVA DG Set Make : Kirloskar
M & L for changing /toping up of best quality of engine oil 20W50 type for various type/capacity DG sets including removing of old burnt engine oil from DG Sets complete all as specified and directed
Supply only cotton waste for daily use for cleaning the DG sets complete all as specified and directed.
Supply and fill batteries distilled water for the DG sets of all Dg set complete all as specified and directed.
Supply and fill batteries electrolyte for the DG sets at all DG Sets complete all as specified and directed.
S&F replacement of auotmatic voltage regulator(AVR) 24 volt all as specified and directed by Engr in Charge.
1010 KVA DG Set Make : Cummins
250 KVA DG Set Make : CG
160 KVA DG Set Make : Kirloskar
100/125 KVA DG Set Make : Kirloskar
82.5 /62/30 KVA DG Set Make : Cummins
M& L for Replacement of water pump assembly for following capacity DG sets complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set Make : Cummins
250 KVA DG Set Make : CG
160 KVA DG Set Make : Kirloskar
100/125 KVA DG Set Make : Kirloskar
Supply and replacement of self starter 12/24 Volt for following capacity DG Set complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set Make : Cummins
250 KVA DG Set Make : CG
160 KVA DG Set Make : Kirloskar
100/125 KVA DG Set Make : Kirloskar
82.5 KVA DG Set Make : Cummins
30 KVA DG Set Make : Kirloskar
Replacement of Turbo charger assy. for following capacity DG sets complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set Make : Cummins
250 KVA DG Set Make : CG
160 KVA DG Set Make : Kirloskar
100/125 KVA DG Set Make : Kirloskar
82.5 KVA DG Set Make : Cummins
30 KVA DG Set Make : Kirloskar
M&L for Replacement of Fan Hub assembely for following capacity of DG Set complete all as specified and directed by Engr in Charge.
1010 KVA DG Set
250/160/125 KVA DG set
M & L for taking out burnt winding of exciter/Starter of following capacity of DG Sets including re-winding copper wire of super quality, of existing size, No of turns, varnishing, heating complete including testing on full load to entire satisfaction of Engr in Charge.
250/200/160 KVA DG Set
35/40 KVA DG set
M & L Cleaning of radiator for following capacity DG sets by using Keroscene oil and radiator cleaning solution (Ready to Wash) by pressure of pump and brush and necessary welding/brazing and Re-assembling after painting of the same complete all as directed.
1010 KVA DG Set Make : Cummins
250 KVA DG Set Make : CG
160 KVA DG Set Make : Kirloskar
100/125 KVA DG Set Make : Kirloskar
82.5 KVA DG Set Make : Cummins
Supply & fixing in replacement of DC wiring of Control panel and DG set of following capacity of DG Sets , complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set Make : Cummins
250/160/200/82 KVA DG Set Make : CG
Supply & fixing in replacement of Hose Pipe of following capacity of DG Sets complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set Make : Cummins
250 KVA DG Set Make : CG
160 KVA DG Set Make : Kirloskar
100/125 KVA DG Set Make : Kirloskar
82.5 KVA DG Set Make : Cummins
Supply & fixing in replacement of Oil sensor suitable for DG set of capacity 82.5/100/160/250/1010 KVA of DG Sets complete all as specified and directed by Engr-in-Charge.
Supply & fixing in replacement of Water/Coolent sensor suitable for DG set of capacity 82.5/100/160/250/1010 KVA of DG Sets complete all as specified and directed by Engr-in-Charge.
M&L for Strip opening of alternator 200/250 KVA DG set , removing rotor from the stator and rewinding to CT coils complete with super enameled copper winding wire of appropriate size including insulating material and replacing the following parts of the alternator. Note: Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engr-in-Charge.
All as per item Ser No. 24.00 here in before but DG set of capacity 125/100/82.5 KVA
Supply and Replacement of Feed pump Assembly suitable for following Capacity DG Sets of existing make and model complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set Make : Cummins
250 /200KVA DG Set Make : CG
160/125 KVA DG Set Make : Kirloskar
82.5 KVA DG Set Make : Cummins
Supply and Replacement of Thermostate valve suitable for 1010/250/200/160/125 KVA DG Sets complete all as specified and directed by Engr-in-Charge.
Supply and Replacement of Oil seal front and rear suitable side for following Capacity DG Sets Complete all as specified and directed by Engr-in-Charge.
1010 KVA DG Set
100/125/160 KVA DG set
Supply and Replacement of battery terminal for DG Sets complete all as specified and directed by Engr-in-Charge.
Supply and fixing battery cable assy. with copper conductor multistranded RED and BLACK colour 2mtr long 20/25 sqmm for connection to self starter unit to Battery unit complete.
M & L for Calibration of Injector unit including supply & fixing in replacement O-Ring, Pin roll, barrel, Pin spring, washer and testing DG Set of capacity up to 1010 KVA Set complete all as specified and as directed by Engr in Charge.
M & L for Calibration of FIP including supply & fixing in replacement plunger, DV, governor wet O-Ring, Pin roll, barrel, Pin ball bearing spring, washer and testing for following capacity of DG Set complete all as specified and directed by engr in Charge.
1010 KVA DG Set
250 KVA DG Set
200/160 KVA DG Set
125/82.5 KVA DG set
30 KVA DG set
Dismantling of nozzle 8 Nos from 1010 KVA DG Set (Make-Cummins) and Calibrate electronic nozel from company and refixing the same and testing all as directed by engineer in charge
All as per item Ser No. 33.00 here in before but DG set of capacity 125/200/160 KVA
All as per item Ser No. 33.00 here in before but DG set of capacity 82.5 KVA
M & L for taking out US electronic nozzles from DG Set of Capacity 200/160 KVA Make Cummins, and S & F new electronic nozzles - 06 Nos of existing make all as specified and directed by Engr-in-Charge
All as per item Ser No. 36.00 here in before but DG set of capacity 30 KVA Make 100 KVA - Cummins, 125 KVA - Kirloskar
Supply and topping up of best quality antifreezing ,inhabitor (Coolant) liquid for DG Set of various capacity and locations complete all as specified and directed.
M & L for replacement of exhaust silencer of 63/100 KVA DG set complete all as specified and directed by Engr in Charge.
M & L Calibration of electronic panel of 200/160/ KVA Cummins DG set with Laptop and fixing all fault including replacement of US relays/wiring as per requirement by cummins engineer all as directed at site
M & L Calibration of electronic panel of 125/82.5/30 KVA Cummins DG set with Laptop and fixing all fault including replacement of US relays/wiring as per requirement by cummins engineer all as directed at site
Supply and fixing DG Set battery of 12 V 180 AH including first filling of distrilled water all as directed at site.Make : Exide/Amaron
Supply and fix in repair off load change over switch 415 volt 50 Hz confirm to IS-13947-3 with enclosure and side handle of cap 400 Amp four pole including takind down old switch Make Havells /C&S/Indoasian
Supply and fix in repair off load change over switch 415 volt 50 Hz conform to IS-13947-3 with enclosure and side handle of cap 200 Amp four pole including takind down old switch Make Havells /C&S/Indoasian
Supply and fix in repair On load change over switch 415 volt 50 Hz confirm to IS-13947-3 with enclosure and side handle of cap 200 Amp four pole including taking down old switch Make Havells /C&S/Indoasian
Supply and fix in repair On load change over switch 415 volt 50 Hz conform to IS-13947-3 with enclosure and side handle of cap 400 Amp four pole including taking down old switch Make Havells /C&S/Indoasian
Supply and fix in repair On load change over switch 415 volt 50 Hz conform to IS-13947-3 with enclosure and side handle of cap 630 Amp four pole including taking down old switch Make Havells /C&S/Indoasian
M & L for cleaning of fuel tank of DG sets of capacity upto 1010 KVA by draining out the fuel and storing in a container for re-filling complete all as specified and directed by Engr-in-charge
S& F In replacement FIP for DG set of Capacity 160/200 KVA Make : Kirloskar of existing make and model as directed by Engr-in-charge
S& F in replacement Control Card (PCB) of existing make and model suitable for DG set of capacity 200/160/125 KVA Make : Kirloskar
Supply and fix in replacement Speed governor suitable for DG Set of capacity 125/160/200 KVA of existing make and model all as specified and directed
M&L for Strip opening of alternator 1010 KVA DG set , removing rotor from the stator and rewinding to CT coils complete with super enameled copper winding wire of appropriate size including insulating material and replacing the following parts of the alternator. Note: Re-assembling all the component of the alternator and mounting the same on the existing foundation including welding of alternator foundation plate by electric arc welding ,aligning the alternator with engine and testing on full load as specified in particular specification and as directed by Engr-in-Charge.
125 KVA KIRLOSKAR GREEN( 'U' Force)
Material and labour for replacement of fuel filter for 125 KVA DG Set , Make:- Kirloskar and change of fuel filter complete all as specified and as directed by Engr-in-Charge.
Material and labour for replacement of oil/Diesel filter for 125 KVA DG Set , Make:- Kirloskar and change of Oil/Diesel filtercomplete all as specified and as directed by Engr-in-Charge.
Material and labour for replacement of air cleaner filter for 125 KVA DG set change of air filter complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of fan belt B-43 cut type for 125 KVA DG set complete all as directed by Engr-in-Charge. Make-Fenner/KCL
Material and labour for replacement of Lub oil pressor Sensor of 125 KVA DG Set complete all as specified and as directed by Engr-in-Charge.Make Kirlosker
Repair calibration checking and pressure testing the fuel injectors FIP 125 KVA including replacement of following worn out spare parts and testing the same after fixing as directed by Engineer-in-Charge.
(i) Injector cups
(ii) Nozzle and'O' rings
Material and labour for replacement of multiple wire connector of 125 KVA DG Set complete all as specified and as directed by Engr-in- Charge.
M & L for replacement of automatic voltage regulator for DG Set of capacity 125 KVA DG set complete satisfaction of Engr-in-Charge.Make : -Kirloskar Green
Repair replacement of ON/OFF switch Push type suitable for 125 KVA Gen along with switch board fixed on pannel or Gen all as required at site for 125 KVA Gen specified or directed by Engr-in-Charge.Make : -Kirloskar Green
Supply and fixing for replacement of copper battery lead 3 Mtrs long PVC insulated multi stranded with brass clamp incl necessary bolts & nuts and fixing lugs etc complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for replacement of copper battery terminals incl necessary bolts & nuts and fixing lugs etc complete all as specified and as directed by Engr-in-Charge.
Repair/servicing self starter by supply and fixing including taking out the following parts ,(a). Field Coil (b).Armature Winding (c ).Bush (d). Solenoid switch (Gear) for 125 KVA DG Sets Make : Kirloskar Green
62.5/63 KVA Kirlosker Green ( 'U' Force)
M&L for replacement of unserviceable/worn out spare part of DG set of cap 62.5/63 KVA, complete all as specified and as directed by Engr-in-Charge. Make- Kirloskar
Calibration of injector assy including replacement of injector cups, barrels, nozzles, orings, screen filter and setting of fuel pressure with testing complete all as specified and directed by Engr in charge.
Material and labour for replacemnt of fuel pipe from pump to fuel filter suitable for 62.5/63 KVA DG sets including benjo bolts, copper washers complete all as specified and directed by Engr in charge. (Make : Kirloskar/Cummins or equivalent)
Material and labour for replacement of air cleaner filter for 62.5/63 KVA DG set change of air filter complete all as specified and as directed by Engr-in-Charge.
Material and labour for replacemnt of lub oil filter complete suitable for 62.5/63 KVA DG Sets of Kirloskar all as specified and directed by Engineer in charge. (Make : Kirloskar or equivalent)
Material and labour for replacement of fuel/disel filter suitable for 62.5/63 KVA DG Sets for pre filter for fine filter Make MICO complete all as specified and directed by Engineer in charge. (Make : Kirloskar or equivalent)
Material and labour for replacement of unserviceable/worn out spare parts of DG set of cap 62.5/63 KVA complete all as specified and directed by Engr in charge.
Fan Belt A-51 V type complete Make : Fenner/KCL
Fan Belt A-48 V type complete Make : Fenner/KCL
Fan Belt BX-49 complete Make : Fenner/KCL
Supply and fix in repair Copper battery lead 2 mtr long 16mm dia multi stranded with brass clamp incl nuts and bolts required.complete all as specified and as directed by Engr-in-charge.
75 KVA Kirlosker Green ( 2ASD Nyoma)
Material and labour for replacemnt of fuel pipe from pump to fuel filter suitable for 75 KVA DG sets including benjo bolts, copper washers complete all as specified and directed by Engr in charge. (Make : Kirloskar/Cummins or equivalent)
Material and labour for feed pump/ pressure pump suitable for 75 KVA Gen set as required at site complete all as specified and as directed by Engr in charge. Make Kirlosker
Material and labour for replacemnt of lub oil filter complete suitable for 75 KVA DG Sets of Kirloskar all as specified and directed by Engineer in charge. (Make : Kirloskar or equivalent)
Material and labour for replacement of fuel/disel filter suitable for 63 KVA DG Sets for pre filter for fine filter complete all as specified and directed by Engineer in charge. (Make : Kirloskar or equivalent)
Material and labour for replacement of air cleaner filter Make Kirloskar suitable for 75 KVA DG Set immersed in oil complete Suitable for DG Set Make Kirloskar, all as specified and directed by Engineer in charge. (Make : Kirloskar)
Material and labour for replacement of unserviceable/worn out spare parts of DG set of cap 63 KVA/75 KVA complete all as specified and directed by Engr in charge.
Fan Belt A-51 V type complete Make : Fenner/KCL
Fan Belt AX-49 complete Make : Fenner/KCL
Repair calibration checking and pressure testing the fuel injectors of FIP 75 KVA Gen including replacement of following worn out spare parts and testing the same after fixing as directed by Engineer-in-Charge.
(i) Injector cups
(ii) Nozzle and'O' rings
Replacement of defective fuel injectors set complete with nozzels.
Repair replacement of ON/OFF switch Push type suitable for 75 KVA Gen along with switch board fixed on pannel or Gen all as required at site for 75 KVA Gen specified or directed by Engineer-in-Charge.
Repair of Dynoma/Alternator of 75 KVA Gen set including rewinding by the same wire gauge complete all as specified and as directed by Engr- In- Charge
Repair/ replacement of Solonoid Switch of 75 KVA Gen set complete all as specified and as directed by Engr- In- Charge
62.5 KVA Kirlosker Green ( 2 ASD Nyoma)
Material and labour for replacemnt of fuel pipe from pump to fuel filter suitable for 62.5/63 KVA DG sets including benjo bolts, copper washers complete all as specified and directed by Engr in charge. (Make : Kirloskar/Cummins or equivalent)
Material and labour for replacemnt of lub oil filter complete suitable for 62.5/ 63 KVA DG Sets complete all as specified and directed by Engineer in charge. (Make : Kirloskar or equivalent)
Material and labour for replacement of fuel/disel filter suitable for 62.5/63 KVA DG Sets for pre filter for fine filter complete all as specified and directed by Engineer in charge. (Make : Kirloskar or equivalent)
Material and labour for replacement of air cleaner filter Make Kirloskar suitable for 62.5/63 KVA DG Set immersed in oil complete Suitable for DG Set Make Kirloskar, complete all as specified and directed by Engineer in charge. (Make : Kirloskar)
Material and labour for replacement of unserviceable/worn out spare parts of DG set of cap 62.5/63 KVA complete all as specified and directed by Engr in charge.
Fan Belt A-51 V type complete Make : Fenner/KCL
Fan Belt AX-49 complete Make : Fenner/KCL
Repair calibration checking and pressure testing the fuel injectors of FIP 62.5/63 KVA Gen including replacement of following worn out spare parts and testing the same after fixing as directed by Engineer-in-Charge.
(i) Injector cups
(ii) Nozzle and'O' rings
Replacement of defective fuel injectors set complete with nozzels.
Repair replacement of ON/OFF switch Push type suitable for 62.5/63 KVA Gen along with switch board fixed on pannel or Gen all as required at site for 75 KVA Gen specified or directed by EIC.
Repair of Dynoma/Alternator of 62.5/63 KVA Gen set including rewinding by the same wire gauge complete all as specified and as directed by Engr- In- Charge
Repair/ replacement of Solonoid Switch of 62.5/63 KVA Gen set complete all as specified and as directed by Engr- In- Charge
Material and labour for feed pump/ pressure pump suitable for 62.5/63 KVA Gen set as required at site complete all as specified and as directed by EIC.Make Kirlosker
125 KVA ( Make- Mahindra) (Dogra Fort)
Material and labour for feed pump/ pressure pump suitable for 125 KVA Gen set as required at site complete all as specified and as directed by EIC.Make- Mahindra
Material and labour for replacement of air cleaner filter Make Mahendra suitable for 125 KVA DG Set complete Suitable for DG Set all as specified and directed by Engineer in charge. (Make : Mahendra )
Material and labour for replacement of Oil filter suitable for 125 KVA DG Set complete Set all as specified and directed by Engineer in charge. (Make : Mahendra )
Material and labour for replacement of Fuel filter suitable for 125 KVA DG Set complete Set all as specified and directed by Engineer in charge. (Make : Mahendra )
Material and labour for replacement of Hose pipe set suitable for 125 KVA DG Set complete Set all as specified and directed by Engineer in charge as required at site. (Make : Mahendra )
Material and labour for replacement of unserviceable/worn out spare parts of DG set of cap 125 KVA complete required at site, all as specified and directed by Engr in charge.
Fan Belt A-47 V type complete Make : Fenner/KCL
Fan Belt A-48 V type complete Make : Fenner/KCL
Fan Belt BX-49 complete Make : Fenner/KCL
M & L for replacement of Oil Pressure guage for DG Set of capacity 125 KVA complete all as specified and directed by Engr in charge.
M & L for replacement of Water temp guage for DG Set of capacity 125 KVA complete all as specified and directed by Engr in charge.
M&L for replacement of lubricant oil pressure sensor suitable for 125 KVA DG, complete all as specified and as directed by Engr-in-charge.
Dismantling the radiator from the engine of 125 KVA DG set installed at Dogra Fort gen set and trasporting the radiator from site to workshop . Dismantling the radiator in and inlcuding descaling, washing with suitable chemical , gas welding the leaking tube whichever required for proper functioning of radiator . The radiator should be fixed in proper condition by the mechanic of authoriesed Kirloshkar company/Kirloshkar dealer. After repair retransportation from workshop to site and fixing the same with engine incl replacement of all connecting hose pipe and suitable fixing clamps and reseting to complete satisfaction of Engr-in-Charge.
45 KVA ( Make- Mahindra) (5255 ASC Coy)
Material and labour for feed pump/ pressure pump suitable for 45 KVA Gen set as required at site complete all as specified and as directed by EIC.Make- Mahindra
Material and labour for replacement of air cleaner filter Make Mahendra suitable for 45 KVA DG Set complete Suitable for DG Set all as specified and directed as required at site by Engineer in charge. (Make : Mahendra )
Material and labour for replacement of Oil filter suitable for 45 KVA DG Set complete Set all as specified and directed as required at site by Engineer in charge. (Make : Mahendra )
Material and labour for replacement of Fuel filter suitable for 45 KVA DG Set complete Set all as specified and directed by Engineer in charge as required at site. (Make : Mahendra )
Material and labour for replacement of Hose pipe set suitable for 45 KVA DG Set complete Set all as specified and directed by Engineer in charge as required at site. (Make : Mahendra )
Material and labour for replacement of unserviceable/worn out spare parts of DG set of cap 45 KVA complete required at site, all as specified and directed by Engr in charge.
(a) Fan Belt A-47 V type complete Make : Fenner/KCL
(b) Fan Belt A-48 V type complete Make : Fenner/KCL
(c) Fan Belt BX-49 complete Make : Fenner/KCL
M & L for replacement of Oil Pressure guage for DG Set of capacity 45 KVA complete all as specified and directed by Engr in charge.
M & L for replacement of Water temp guage for DG Set of capacity 45 KVA complete all as specified and directed by Engr in charge.
M&L for replacement of lubricant oil pressure sensor suitable for 45 KVA DG, complete all as specified and as directed by Engr-in-charge.
Repair replacement of ON/OFF switch Push type suitable for 62.5/63 KVA Gen along with switch board fixed on pannel or Gen all as required at site for 75 KVA Gen specified or directed by EIC.
Dismantling the radiator from the engine of 45 KVA DG set installed at 5255 ASC Coy and trasporting the radiator from site to workshop . Dismantling the radiator in and inlcuding descaling, washing with suitable chemical , gas welding the leaking tube whichever required for proper functioning of radiator . The radiator should be fixed in proper condition by the mechanic of authoriesed Kirloshkar company/Kirloshkar dealer. After repair retransportation from workshop to site and fixing the same with engine incl replacement of all connecting hose pipe and suitable fixing clamps and reseting to complete satisfaction of Engr-in-Charge.
15 KVA KOEL GREEN ( Upper Chumathang)
Material and labour for replacement of fuel filter for 15 KVA DG Set , Make:- Koel green and change of fuel filter complete all as specified and as directed by Engr-in-Charge.
Material and labour for replacement of Oil filter for 15 KVA DG Set , Make:- Koel Green and change of Oil filter complete all as specified and as directed by Engr-in-Charge.
Material and labour for replacement of air cleaner filter for 15 KVA DG set , (Make:- Koel Green ) change of air filter complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of fan belt sutiable for 15 KVA DG set complete all as directed by Engr-in-Charge.
Material and labour for replacement of Lub oil pressor Sensor of 15 KVA DG Set complete all as specified and as directed by Engr-in-Charge. Make Koel Green.
Repair calibration checking and pressure testing the fuel injectors FIP 15 KVA including replacement of following worn out spare parts and testing the same after fixing as directed by Engineer-in-Charge.
(i) Injector cups
(ii) Nozzle and'O' rings
M & L for replacement of automatic voltage regulator for DG Set of capacity 15 KVA DG set complete satisfaction of Engr-in-Charge.Make : -Koel Green .
Supply and fixing for replacement of copper battery lead 3 Mtrs long PVC insulated multi stranded with brass clamp incl necessary bolts & nuts and fixing lugs etc complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for replacement of copper battery terminals incl necessary bolts & nuts and fixing lugs etc complete all as specified and as directed by Engr-in-Charge.
Repair/servicing self starter by supply and fixing including taking out the following parts ,(a). Field Coil (b).Armature Winding (c ).Bush (d). Solenoid switch (Gear) for 15 KVA DG Sets Make : Koel Green
Repair of Dynoma/Alternator of 15 KVA Gen set including rewinding by the same wire gauge complete all as specified and as directed by Engr- In- Charge.
15 KVA( Make- Mahindra) (Lower Chumathang)
Material and labour for replacement of fuel filter for 15 KVA DG Set , Make:- Mahindra and change of fuel filter complete all as specified and as directed by Engr-in-Charge.
Material and labour for replacement of Oil filter for 15 KVA DG Set , Make:- Mahindra and change of Oil filter complete all as specified and as directed by Engr-in-Charge.
Material and labour for replacement of air cleaner filter for 15 KVA DG set change of air filter complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of fan belt sutiable for 15 KVA DG set complete all as directed by Engr-in-Charge.
Material and labour for replacement of Lub oil pressor Sensor of 15 KVA DG Set complete all as specified and as directed by Engr-in-Charge.Make Mahindra
Repair calibration checking and pressure testing the fuel injectors FIP 15 KVA including replacement of following worn out spare parts and testing the same after fixing as directed by Engineer-in-Charge.
(i) Injector cups
(ii) Nozzle and'O' rings
M & L for replacement of automatic voltage regulator for DG Set of capacity 15 KVA DG set complete satisfaction of Engr-in-Charge.Make : - Mahindra
Supply and fixing for replacement of copper battery lead 3 Mtrs long PVC insulated multi stranded with brass clamp incl necessary bolts & nuts and fixing lugs etc complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for replacement of copper battery terminals incl necessary bolts & nuts and fixing lugs etc complete all as specified and as directed by Engr-in-Charge.
Repair/servicing self starter by supply and fixing including taking out the following parts ,(a). Field Coil (b).Armature Winding (c ).Bush (d). Solenoid switch (Gear) for 15 KVA DG Sets Make : Mahindra
Repair of Dynoma/Alternator of 15 KVA Gen set including rewinding by the same wire gauge complete all as specified and as directed by Engr- In- Charge.Make : Mahindra
25 KVA (Mahindra 2 ASD Nyoma)
Material and labour for replacement of fuel filter for 25 KVA DG Set , Make:- Mahindra and change of fuel filter complete all as specified and as directed by Engr-in-Charge.
Material and labour for replacement of Oil filter for 25 KVA DG Set , Make:- Mahindra and change of Oil filter complete all as specified and as directed by Engr-in-Charge.
Material and labour for replacement of air cleaner filter for 25 KVA DG set change of air filter complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of fan belt sutiable for 25 KVA DG set complete all as directed by Engr-in-Charge.
Material and labour for replacement of Lub oil pressor Sensor of 25 KVA DG Set complete all as specified and as directed by Engr-in-Charge.Make Mahindra
Repair calibration checking and pressure testing the fuel injectors FIP 25 KVA including replacement of following worn out spare parts and testing the same after fixing as directed by Engineer-in-Charge.
(i) Injector cups
(ii) Nozzle and'O' rings
M & L for replacement of automatic voltage regulator for DG Set of capacity 25 KVA DG set complete satisfaction of Engr-in-Charge.Make : - Mahindra
Supply and fixing for replacement of copper battery lead 3 Mtrs long PVC insulated multi stranded with brass clamp incl necessary bolts & nuts and fixing lugs etc complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for replacement of copper battery terminals incl necessary bolts & nuts and fixing lugs etc complete all as specified and as directed by Engr-in-Charge.
Repair/servicing self starter by supply and fixing including taking out the following parts ,(a). Field Coil (b).Armature Winding (c ).Bush (d). Solenoid switch (Gear) for 25 KVA DG Sets Make : Mahindra
Repair of Dynamo/Alternator of 25 KVA Gen set including rewinding by the same wire gauge complete all as specified and as directed by Engr- In- Charge.
62.5 KVA (Mahindra 2 ASD Nyoma)
Material and labour for replacement of fuel filter for 62.5 KVA DG Set , Make:- Mahindra and change of fuel filter complete all as specified and as directed by Engr-in-Charge.
Material and labour for replacement of Oil filter for 62.5 KVA DG Set , Make:- Mahindra and change of Oil filter complete all as specified and as directed by Engr-in-Charge.
Material and labour for replacement of air cleaner filter for 62.5 KVA DG set change of air filter complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of fan belt sutiable for 62.5 KVA DG set complete all as directed by Engr-in-Charge.
Material and labour for replacement of Lub oil pressor Sensor of 62.5 KVA DG Set complete all as specified and as directed by Engr-in-Charge.Make Mahindra
Repair calibration checking and pressure testing the fuel injectors FIP 62.5 KVA including replacement of following worn out spare parts and testing the same after fixing as directed by Engineer-in-Charge.
(i) Injector cups
(ii) Nozzle and'O' rings
M & L for replacement of automatic voltage regulator for DG Set of capacity 62.5 KVA DG set complete satisfaction of Engr-in-Charge.Make : - Mahindra
Supply and fixing for replacement of copper battery lead 3 Mtrs long PVC insulated multi stranded with brass clamp incl necessary bolts & nuts and fixing lugs etc complete all as specified and as directed by Engr-in-Charge.
Supply and fixing for replacement of copper battery terminals incl necessary bolts & nuts and fixing lugs etc complete all as specified and as directed by Engr-in-Charge.
Repair/servicing self starter by supply and fixing including taking out the following parts ,(a). Field Coil (b).Armature Winding (c ).Bush (d). Solenoid switch (Gear) for 62.5 KVA DG Sets Make : Mahindra
Repair of Dynoma/Alternator of 62.5 KVA Gen set including rewinding by the same wire gauge complete all as specified and as directed by Engr- In- Charge.
Draining all the U/S DAFC 50% from the DG Sets Supply and filling theDAFC 50% all as specified and as directed by Engr-in-charge.Make Servo, HP or any approved Make.
Draining all the U/S E Oil from the DG Sets Supply and filling the 15/20 W 40 E oil all as specified and as directed by Engr-in-charge.Make Servo, HP or any approved Make.
Supply & fix in replacement of U/S lead acid battery 12 Volt 180AH with initially charged Make-Exide
Supply & fix in replacement of old US Battery charger 24 volt Make- FLAKE and equivalent.
M/S NISSAR ALI
M/S TRADE LINK
M/S BETONG CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .