Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.4 LAccepted-AOC | L1 | Accepted-AOC BEING L-1 BIDDER | |
| 2 | L2₹48.9 L+₹5.3 L (12.2%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹49.7 L+₹6.1 L (14.0%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹49.8 L+₹6.2 L (14.1%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹50.0 L+₹6.4 L (14.7%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
| Sl No | Description | Qty | Unit | c p engineering works L1 | M/s Jai Sree Hari L2 | M/s Ats Electricals L4 | JPR CONSTRUCTIONS AND ENGINEERS L6 | P JAGANNADHARAJU L5 | VIRAN group L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down rolling shutters including all hardware fittings at any height (upto 12 Mtr) complete all as specified & directed | 3 | Each | 2,800 ₹8,400 Lowest | 3,000 ₹9,000 | 3,500 ₹10,500 | 3,510 ₹10,530 | 3,500 ₹10,500 | 4,500 ₹13,500 |
| 2.00 | S & F in repair Complete rolling shutter including 1.00 mm thick mild steel rolling shutter strips duly pressed on both ends of vertical sides for interlocking locks for the required length of existing steel rolling shutter including oiling and greasing to required necessary fitting to functionall shutters as required bush, Spring. MS pipe , rod .lock. ball bearing, top cover, anchoring rod, hasp and staple and push pull or gear operating system , bevel gear box and crank handle etc at any height (upto 12 Mtr) complete all as specified.and directed. as directed by Engg-in-Charge | 100 | Sqm | 7,200 ₹7,20,000 Lowest | 8,000 ₹8,00,000 | 8,500 ₹8,50,000 | 10,000 ₹10,00,000 | 10,020 ₹10,02,000 | 8,521 ₹8,52,100 |
| 3.00 | M&L Cutting holes in brick walls exc one brick but not exc two brick built in cement mortor or cement lime mortor and stone walls built in lime mortor for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required at any height (upto 12 Mtr) complete all as specified and directed. | 38 | Each | 300 ₹11,400 Lowest | 450 ₹17,100 | 450 ₹17,100 | 430 ₹16,340 | 420 ₹15,960 | 451 ₹17,138 |
| 4.00 | M&L for two coats synthetic enamelled paint to new steel surfaces after preparation over a coat of red oxide primer area over exc 10cm in width or girth etc complete all as specified and directed. | 295 | Sqm | 120 ₹35,400 Lowest | 150 ₹44,250 | 180 ₹53,100 | 155 ₹45,725 | 145 ₹42,775 | 180 ₹53,100 |
| 5.00 | Taking down cover hood of existing rolling shutters (gear operated/ manually size any type ) carefully and completely over hauling the shutters by applying grease and oil in bearing, springs, guide cannels, operating rods, shaft gear boxes, gear wheel etc straightening thoroughly shutter blades, guide channels anchoring rods etc and fixing back the over hood in position and ensure smooth functioning of shutters at any height (upto 12 Mtr) complete all as directed. (Note : worn out part for replacement will be measured and paid separately.) | 16 | Each | 4,000 ₹64,000 Lowest | 4,200 ₹67,200 | 4,500 ₹72,000 | 4,160 ₹66,560 | 4,150 ₹66,400 | 4,511 ₹72,176 |
| 6.00 | Supply and fixing in repairs MS gear box complete incl handle and anchoring rod as of approved quality of steel rolling shutters at any height (upto 12 Mtr) complete all as specified and directed | 16 | Each | 7,000 ₹1,12,000 Lowest | 7,500 ₹1,20,000 | 7,500 ₹1,20,000 | 7,260 ₹1,16,160 | 7,250 ₹1,16,000 | 7,519 ₹1,20,304 |
| 7.00 | All as per item no. 6 but Ball bearing suitable for rolling shutter | 32 | Each | 500 ₹16,000 Lowest | 650 ₹20,800 | 650 ₹20,800 | 640 ₹20,480 | 630 ₹20,160 | 500 ₹16,000 Lowest |
| 8.00 | All as per item no. 6 but Guide channel 3" (3.50 mm thick) | 120 | RM | 1,200 ₹1,44,000 | 1,500 ₹1,80,000 | 1,450 ₹1,74,000 | 1,310 ₹1,57,200 | 1,300 ₹1,56,000 | 1,000 ₹1,20,000 Lowest |
| 9.00 | All as per item no. 6 but Cover hood made of 1 mm thk plain GI Sheet pattern | 160 | Sqm | 2,500 ₹4,00,000 Lowest | 3,000 ₹4,80,000 | 2,600 ₹4,16,000 | 2,710 ₹4,33,600 | 2,700 ₹4,32,000 | 2,800 ₹4,48,000 |
| 10.00 | All as per item no. 6 but Bottom plate 5" (2.25mm) | 90 | RM | 2,500 ₹2,25,000 Lowest | 2,600 ₹2,34,000 | 2,650 ₹2,38,500 | 2,710 ₹2,43,900 | 2,700 ₹2,43,000 | 3,200 ₹2,88,000 |
Tender Value
Refer Docs
EMD Value
₹81,000
Closing Date
17 Jan 2026, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
SPECIAL REPAIRS OF 19 X SHUTTERS 04 X SHUTTERS OF 19 AD REGT AND GARAGE NEAR BLDG NO P 310 UNDER GE I GOS
2025_MES_746053_1
8000/108/2025-26/1007/E8
Open Tender
Civil Works
Item Rate
180 days
GOS
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER I GOS
₹81,000
11 Jul 2026
24 Dec 2025
19 Jan 2026
24 Dec 2025
17 Jan 2026
9 Jan 2026
Taking down rolling shutters including all hardware fittings at any height (upto 12 Mtr) complete all as specified & directed
S & F in repair Complete rolling shutter including 1.00 mm thick mild steel rolling shutter strips duly pressed on both ends of vertical sides for interlocking locks for the required length of existing steel rolling shutter including oiling and greasing to required necessary fitting to functionall shutters as required bush, Spring. MS pipe , rod .lock. ball bearing, top cover, anchoring rod, hasp and staple and push pull or gear operating system , bevel gear box and crank handle etc at any height (upto 12 Mtr) complete all as specified.and directed. as directed by Engg-in-Charge
M&L Cutting holes in brick walls exc one brick but not exc two brick built in cement mortor or cement lime mortor and stone walls built in lime mortor for inserting hold fasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required at any height (upto 12 Mtr) complete all as specified and directed.
M&L for two coats synthetic enamelled paint to new steel surfaces after preparation over a coat of red oxide primer area over exc 10cm in width or girth etc complete all as specified and directed.
Taking down cover hood of existing rolling shutters (gear operated/ manually size any type ) carefully and completely over hauling the shutters by applying grease and oil in bearing, springs, guide cannels, operating rods, shaft gear boxes, gear wheel etc straightening thoroughly shutter blades, guide channels anchoring rods etc and fixing back the over hood in position and ensure smooth functioning of shutters at any height (upto 12 Mtr) complete all as directed. (Note : worn out part for replacement will be measured and paid separately.)
Supply and fixing in repairs MS gear box complete incl handle and anchoring rod as of approved quality of steel rolling shutters at any height (upto 12 Mtr) complete all as specified and directed
All as per item no. 6 but Ball bearing suitable for rolling shutter
All as per item no. 6 but Guide channel 3" (3.50 mm thick)
All as per item no. 6 but Cover hood made of 1 mm thk plain GI Sheet pattern
All as per item no. 6 but Bottom plate 5" (2.25mm)
All as per item no. 6 but C Class pipe 50 mm dia in shaft
All as per item no. 6 but Anchoring rod of 25 mm dia of MS pipe
All as per item no. 6 but Safety lever locks MS with 4 levers
M&L Removing old paints by paint removes or burning off by blow lamps and cleaning with scrapers, any number of coats,any width or girth complete all as specified and directed.
M&L for preparation of old steel surfaces of any description, over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for cleaning and preparing the surfaces to be welded together, holding the members in true position while welding and bevelling of edges, thickness of metal to be welded exc 3 mm but n exc 6 mm complete all as specified and directed. (Note : Taking down the article and refixing in position after welding shall be measured separately)
M&L for cleaning and preparing the surfaces to be welded together, holding the members in true position while welding and bevelling of edges, thickness of metal to be welded exc 6 mm but n exc 9 mm complete all as specified and directed. (Note : Taking down the article and refixing in position after welding shall be measured separately)
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified & directed by Engineer-In-Charge
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Demolition of brick work built in cement mortar including all quions, arches, pillars etc at any height (upto 12 Mtr) all as specified and directed
M & L for old size brick work with fly ash bricks straight or curved on plan exc 6m mean radius in CM 1:6 at any height (upto 12 Mtr) completed all as specified and directed.
Taking down cement or cement lime plaster, of any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc at any height (upto 12 Mtr) complete all as specified and directed.
M&L for Rendering 15 mm thick in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) at any height (upto 12 Mtr) complete all as specified and directed.
M&L for rendering 5 mm thick in CM 1:3 on RCC ceiling surface and finished even and smooth with out using extra cement at any height (upto 12 Mtr) complete all as specified and directed .
M&L for applying 2mm thick Birla / JK Putty in two layers on newly plastered walls surfaces/matching to old surface of walls making absolutely even and smooth, rubbing with sand paperat any height (upto 12 Mtr) complete all as specified and directed
M&L for applying two coats of oil bound distemper on wall or concrete surfaces over & including a coat of primer on newly prepared surfaces/matching to old surface of walls including, rubbing with sand paper at any height (upto 12 Mtr) complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls/matching to old surface of walls and apply three coat of white wash at any height (upto 12 Mtr) complete all as specified and directed.
M&L for preparation of newly plastered surfaces/matching to old surface of walls of ceilings and apply three coat of white wash at any height (upto 12 Mtr) complete all as specified and directed.
M & L for two coats of cement based paint over a coat of primer on new plastered surface of walls or matching to old surface of walls including preparation of surface complete all as specified and directed.
Taking down rolling shutters of any size including all hardware fittings complete all as specified & directed by Engineer-In-Charge
M&L Cutting holes in brick walls built in cement mortar or cement lime mortar and stone walls built in lime mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified & directed by Engineer-In-Charge
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified & directed by Engineer-In-Charge
S&F in repair MS pipe 50 to 125 mm dia as shaft including two coats of aluminum paint over a coat red oxide primer complete all as specifed & directed.
S&F in repair part of steel rolling shutters MS gear box set general complete incl handle and anchoring rod as of approved quality all as specified and directed.
S&F in repair Ball bearing suitable for rolling shutter complete all as specified and directed.
S&F in repair Guide channel 3" (3.50 mm thick) mild steel deep channel section etc.complete all as specified and directed.
S&F in repair Hood Cover made of 1 mm thick GI Sheet pattern
S&F in repair Bottom plate 5" (2.25mm) complete all as specified and directed.
S&F in repair Anchoring rod of 25 mm dia of MS pipe complete all as specified and directed.
S&F in repair Safety lever locks MS with 4 levers complete all as specified and directed.
Taking down and refixing in the same opening steel rolling shutter including oiling and greasing to required necessary fitting to functionall shutters as required bush, Spring. MS pipe , rod .lock. ball bearing, top cover, anchoring rod, hasp and staple and push pull or gear operating system , bevel gear box and crank handle etc complete all as specified.and directed.(area of rolling shutters exc 6 sqm but n. exc. 18 Sqm each ) (Note:- Necessary constituent items required during repair of rolling shutter shall be paid seperately as given above .)
S & F in repair Complete rolling shutter including 1.00 mm thick mild steel rolling shutter strips duly pressed on both ends of vertical sides for interlocking locks for the required length of existing steel rolling shutter including oiling and greasing to required necessary fitting to functionall shutters as required bush, Spring. MS pipe , rod .lock. ball bearing, top cover, anchoring rod, hasp and staple and push pull or gear operating system , bevel gear box and crank handle etc complete all as specified.and directed. as directed by Engg-in-Charge
S & F in repair 1.00 mm thick mild steel rolling shutter strips duly pressed on both ends of vertical sides for interlocking locks for the required length of existing steel rolling shutter complete all as specified.and directed. as directed by Engg-in-Charge
M&L for preparation of new or previously untreated surfaces of steel of any description, over 10cm in width or girth and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L preparation of old decorated Steel painted surfaces of any description not other wise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Demolition of brick work built in cement mortar including all quions, arches, pillars etc all as specified and directed
M & L for old size brick work with fly ash bricks straight or curved on plan exc 6m mean radius in CM 1:6 completed all as specified and directed.
M&L for rendering 10 mm thick on other than fair face of brick works in CM 1:6 and to be finished even and smooth with out using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick in CM (1:4) on fair faces of brick or concrete surface of wall and finished even and smooth with out using extra cement complete all as specified and directed.
M&L for preparation of new decorated surfaces of walls and apply one coat of white wash complete all as specified and directed
M&L for preparation of new plastered surfaces of walls and applying one coat of oil bound distemper complete all as specified and directed.
Preparation of Newly Plastered surfaces and applying two coat of Cement Base Paint on walls all as specified and directed by Engineer-in-Charge.
Dismantling of Wooden Wall Panelling with base plywood work incl all hardware items and removing to store complete all as specified and directed.
M&L Plywood, grade BWR, type BB, 12 mm thickness in first layer for making the base for second layer for panelling fixed with nails to timber framework complete all as specified and directed.
M&L PVC wall lining consisting of 5 mm thick single side prelam PVC sheet inclusive of solvent cement and fixing at site on PVC frame complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/slabs /blankets, any thickness, including cover fillets complete all as specified and directed.
S&F 12 mm thick plain Gypsum Board False Ceiling with GI frame including all necessary drilling cutting to fix electric items complete all as specified and directed with following:- (a) GI Grid channel 30x25x20 mm of 24 gauge fixed with rawl plug and screw 450 mm centre to centre alongwith perimeter walls. (b) GI channel made to shape 50x40x40 mm of 24 gauge placed @ 600 mm centre to centre from perimeter at wall except long wall (in one span). (c) GI intermediate runners of size 45x10x10 mm of 24 gauge fixed @ 1200 mm centre to centre leaving frame of one side walls (in other span). (d) GI sheet 25 mm wide and 20 mm gauge suspended fixed with steel fastner to roof ceiling and 1200 mm centre to centre including pluging of RCC Slab. (e) 12 mm thick gypsum board filling joints with POP and finishing complete with two coat of plastic emulsion paint over one coat of primer on ceiling.
S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples complete all as specified and directed.
Taking down chowkhat or frames n exc 1.50 Sqm each with shutters (without taking off shutters from the frame) and removing to store complete all as specified and directed
Dismantling of floor, hearth, walls, roof tiles including bedding (but not backing), and rubbish off permises complete all as specified and directed.
Demolition of Cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified & directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring average 25 mm thick surface finished even and rough (as in levelling course) to receive the topping layer complete all as specified and directed.
M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 for laying of floor tiles complete all as specified and directed.
M & L for Vitrified Ceramic tiles light shade polished (square / rectangular) of 7 to 8mm thick, area of each tile exceeding 0.42 sqm but not exc. 1.00sqm as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile complete all as specified and directed.
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
Racking out joints / pointing to stone masonry coursed or un-coursed built in cement mortar or cement lime mortar complete all as specified and directed.
M & L for block masonry with solid pre-cast cement concrete blocks made out of cement concrete 1: 2: 4 type B-1, using 20 mm graded stone aggregate, exc. 10 cm in width and setting in cement mortar 1 : 6 complete all as specified and directed.
Demolition of Cement Concrete (unreinforced) of any description & in any position not otherwise specifically provided for. Complete all as specified & directed.
M&L for two coats synthetic enamelled paint to new steel surfaces after preparation over a coat of red oxide primer area over exc 10cm in width or girth etc all as specified and directed by Engr - in - Charge.
S&F pre- painted galvalume aluminum zinc corrugated steel based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping serews as specified and directed by Engr - in - Charge.
Dismantling asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings including ridges complete all as specified and directed.
M&L for Fe 410-W (Gde E-250 quality A) Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Racking out joints / pointing to stone masonry coursed or un-coursed built in cement mortar or cement lime mortar complete all as specified and directed.
M&L Random rubble masonry walling well bonded, bedded, solidly hearted, uncoursed built in CM 1:6.Complete all as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in lintels upto 1.5 m clear span, coping, benching, bed block, lintel band, plinth courses etc and similar work including weathering,slightly rounded or chamfered angles and throating including necessary form work complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings i.e removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made for conditions separately ) and including making good the disturbed surfaces to match with existing surface and colour shade with putty for smooth finishing without andulations complete all as specified and directed
Material and labour for cutting chasing,pinning of brick/ stone/concrete wall at any height wall cutting and chases for concealed wiring for 20/25 mm PVC conduit dia pipe,water tubing,etc and making good to facings where required and pointing in cement motor 1:3 to ends or edges of landigs,wall surfaces etc,cutting not exc 10 cm girth and including making good the disturbed surfaces to match with existing surface and colour shade with proper putty for smooth finishing with existing wall complete all as specified and directed
M&L for point wiring using approved colour coding incl providing circuit wiring with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conf to IS-694/1990 unsheathed, multistranded, single core, copper cable 1100 volts grade cables drawn through PVC Conduit 20/25 mm dia medium grade(MMS) at any height and all accessories are concealed in walls / roofs / floors / ceiling etc. incl providing flush mounting modular MS box made out of 1.60mm thick suitable for modular top cover and frame for fixing of modular switches,sockets,fan regulators, blank plate etc and including 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with necessary putty for smooth finishing complete all as specified and directed for One light point controlled by one 10amps switch.
All as per item no. 81 but for One fan point controlled by one switch 10 amps, and one regulator.
All as per item no. 81 but for One 5 pin 6 amps socket point controlled by one 10 amps switch on independent board .
All as per item no. 81 but for One 5 pin 6 amps socket point controlled by one 10 amps switch on same board .
All as per item no. 81 but for point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for the following:-
All as per item no. 85 but for One 6 pin 16/6 amps socket outlet point controlled by one 16/20 amps switch on independent board.
All as per item no. 81 but for One 6 pin 16/6 amps socket outlet point controlled by one 16/20 amps switch on same board.
All as per item no. 81 but for point wiring with 4.0 sqmm and earth conductor of size 4 sqmm complete all as specified and directed.
Supply & fixing modular type switches, 10 Amps, single pole,1way,1 module,240V,AC, ISI Marked complete all as specified and directed
Supply & fixing modular type switches, 16/20 Amps, single pole,1way,1 module,240V,AC, ISI Marked complete all as specified and directed.
Supply & fixing modular type socket with shuttered type 6/10 Amps, 2/3 Pin combined 2 module,240V,AC ISI Marked complete all as specified and directed.
Supply & fixing modular type socket with shuttered type 16/20 Amps, 2/3 Pin combined 2 module,240V,AC ISI Marked complete all as specified and directed.
Supply & fixing modular type step fan speed regulator 120W, 2 module,230volts,AC, 360 degree rotation 0 to 8 steps, ISI Marked complete all as specified and directed.
Supply & fixing angle lamp holder, insulated body with back plate for batten fittings,ISI Marked latest model complete all as specified and directed.
Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body ISI Marked latest model complete all as specified and directed.
Supply & fix decorative box type 20 watt light fitting, end caps, pre-wired and including providing single/double side LED tube light (tube rod) white/warm 20 watt-01 No made of aluminium extrusion with high efficient LED driver,IP-20, Tube efficiency of 100lm/w, including PVC/Wooden round/square block -02 Nos and connected with LED fitting to ceiling rose and including removing old unserviceable fitting complete all as specified and directed.
S & F Energy efficient and energy saving new generation 10 watts LED bulk head light fitting IP-65 luminaire with opel diffuser pre-wired of luminaires including LED light driver and connected with LED fitting to ceiling rose terminal and incl removing old unserviceable fitting complete all as specified and directed.
Supply and fixed in repairs LED bldg secruity light fitting of capacity 45 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protection with 4/5 KV inbuilt surge protector and cable connection from ceiling rose/looping box/switch board/DBs to light fitting and testing and including removing of old unserviceable item complete all as specified and directed.
Supply and fix GI bracket pipe of size 32 to 40 mm dia as suitable medium grade of 1.2 mtr long bent to shape suitable degree of bending as per site requirement with hot or cold bending method of process for making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixed on wall surfaces and including providing suitable fabricate galvanised flat iron clamps of 30X6 mm thick -02 Nos suitable for fixing at any place/height with hole fastners,nuts,bolts & washers including grouting on wall etc and including removing of old unserviceable item complete all as specified and directed.
Supply & fix and sheet metal enclosure, with acrylic type double door, 240 volts AC,SPN,DB, 4 way, flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer,MCB SPN/DP, and MCB SP as outgoing for IP 43& IP54 DBs protection nd including removing old unserviceable DBs making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed.
Supply & fix MCB SP 6 to 32 Amps 10 KA,"C" series,AC,240Volts,50Hz , ISI marked and including removing old unsv items complete all as specified and directed.
Supply & fix and MCB SPN 32 to 40 Amps 10 KA,"C" series,AC,240Volts,50Hz, ISI marked and including removing old unsv items complete all as specified and directed.
Taking down old unserviceable ceiling fans of any type/sweep from work site and deposit to MES store yard supply and fix new ceiling fan with blades, down rods, and connected accessories, 230 V, 1400 mm sweep,copper winding with squirrel cage induction motor, anti dust painted, dust free,high speed. Star rated complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 32 X 6 mm from earth electrode to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including char coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber 1:3:6 type C1,RCC cover 1:2:4 type B1, including excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value complete all as specified and directed.
Material and labour for PVC insulated,LT armoured electric cable with aluminium standed conductor 1100 volts grade,cross-sectional area 6 sqmm ,2.0 core laid in trenches/pipes/ducts/wall/boarings with necessary cable lugs and glands,nuts,bolts and washers,saddeling on wall properly etc and testing and including removing old unsv UG cables complete all as specified and directed.
Boaring holes horizontally under road without damaging the surface of road (minimum 1.0 Mtr bellow the road surface) with the help of GI tubing of any dia not exc 80mm dia for passing of UG cable all as specified and as directed.
Material and labour for PCC 1:2:4 type B1 using 20 mm grade aggregate as in pre cast cover slabs including form work and set in cement motor 1:6 complete all as spfd and directed.
Material & labour for GI pipe 80 mm " light grade'' laid in trenches floors/on,pole/road for cable protection with all fittings complete all as specified and directed.Make:-Jindal/Tata/Swastik/BST.
Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed.
Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all as specified and directed.
Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed
Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed
M & L for brick sub class 'B' 250mm x 115mm x 0.75mm and laid in trenches as in protection of UG cable complete all as specified and directed.
Material & labour for GI pipe 50 mm "light grade" laid in trenches floors/on , pole/road for cable protection with all fittings complete all as specified and directed.
Supply, errect, installation of octagonal GI pole mast 7 mtr length pole,with flange at bottom 120 mm dia and top 100 mm dia and suitable fixing arrangements for street light fitting and connected works such as GI suitable braket and clamping works, incl providing anchorage steel nuts,bolts and washers for four sides and necessary fixing arrangements and including providing RCC block of size 0.75mtr X 0.75 mtr x0.75 mtr, and incl providing grouting with bolts and nuts for bottom flange plate arrangemets of octagnal pole buttom plate and necessary hardwares complete all as specified and directed. Note:-1. GI pole installed on GI octagonal pole mast poles and connected materials as approved make by GE. 2. The make shall be of manufactures as listed in perticular specification here-in-after.3. Including providing necessary heavy duty Bolts,nuts and washers as per OEM supplied accessories arranged site as per site requirement upto Engineer-in-Charge satifaction complete all as directed.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.52 MB
tender_docs.pdf
Tender Documents • 1.34 MB
BOQ_835383.xls
BOQ • 2.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .