Capital (Works)
Strengthening and Augmentation of Signalling Assets at LC gates for reliability improvement, enhancing safety and improving punctuality in Train operations along with alteration in EI for the closure of LC gates at various interlocked LC gates under Danapur division.
DNRsnTSig2026-8~ECR
DNRsnTSig2026-8
Open
Works - General
18 Months
Patna, Bihar
₹0
₹13.1 L
22 Jun 2026
29 May 2026
8 Jun 2026
100 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 6,53,23,069.55 | ||
| — | 32.00 | — | — | ||
| Supply, transportation, installation & commissioning electrically operated lifting barrier set as per spec. no. RDSO/SPN/208/2012 ver. 2.0 or latest each consisting of 2 nos. of lifting barrier pedestals, each with min. 6 contact circuit controller with top roller type limit switches, hand crank, 2 electric motors, 110VAC of capacity suitable to operate barriers upto 32' long booms, 2 nos. of steel octagonal booms of 32' length with 2 nos. stop boards. Boom light boxes, ms counter weights and 2 nos. of boom support with suitable boom locking but without fringes along with control panel with buttons and indicating lamps, motor connectors and mcb to operate 2 barriers of 1 set. this includes supply and installation of gate hooter - 1 no. and horn ( 8 watt) - 1 no. with all fixing arrangements. All of the above items including supply of cement, civil work materials etc. shall be done by the contractor for commissioning. 230vac supply only shall be arranged by the railway in near by relay room. (Complete set ) as per site requirement (i) Supply-Inspectio-RDSO | — | — | — | 1,41,86,863.68 | |
| — | 32.00 | — | — | ||
| Supply, transportation, installation & commissioning electrically operated lifting barrier set as per spec. no. RDSO/SPN/208/2012 ver. 2.0 or latest each consisting of 2 nos. of lifting barrier pedestals, each with min. 6 contact circuit controller with top roller type limit switches, hand crank, 2 electric motors, 110VAC of capacity suitable to operate barriers upto 32' long booms, 2 nos. of steel octagonal booms of 32' length with 2 nos. stop boards. boom light boxes, MS counter weights and 2 nos. of boom support with suitable boom locking but without fringes along with control panel with buttons and indicating lamps, motor connectors and MCB to operate 2 barriers of 1 set. this includes supply and installation of gate hooter - 1 no. and horn( 8 watt) - 1 no. with all fixing arrangements . All of the above items including supply of cement, civil work materials etc. shall be done by the contractor for commissioning. 230vac supply only shall be arranged by the railway in near by relay room. (complete set ) as per site requirement (ii) Execution | — | — | — | 18,17,517.12 | |
| — | 100.00 | — | — | ||
| Supply of 32 ft long octagonal booms as per RDSO spec no. RDSO/SPN/208/2012 (ver 2.0) with latest amendment. Inspection-RDSO | — | — | — | 48,85,483 | |
| — | 15.00 | — | — | ||
| Supply of Sliding boom gate as per E.Rly signal workshop/HWH dwg no. BSA/29/ 730 BSA/29/731 &BSA/29/737. this includes supply of 8 nos. 'e' type lock with key as per irs spec. irs:S-30/64 with latest amendment . key lock e type as per drawing no. sa-3376/m with latest amendment, key for e type lock as per drawing no. 3377/m with latest amendment ward no. to be fixed on MS plate as mentioned in the drawing. Inspection-RITES | — | — | — | 40,24,436.7 | |
| — | 15.00 | — | — | ||
| Installation & commissioning of sliding boom gate. This includes levelling , fixing of sliding boom with fixing of e type lock etc. note all materials except sliding boom gate to be supplied by the contractor. | — | — | — | 87,117.45 | |
| — | 15.00 | — | — | ||
| Casting concreting & curing of foundation (1:3:6) for sliding gate as per dwg. no. SGW-SDAH / sliding gate foundation / 2012 including supply & fixing of holding down bolts with washers and nuts , MS plates of size 350 mm x 350mm x 8 mm, cement etc. 10 foundations required in each set of gate. | — | — | — | 9,86,585.85 | |
| — | 15000.00 | — | — | ||
| "Excavation of Trench in all kinds of soil and refilling of trenches (1.2 Mtr, Depth, 300 mm Width) - without bricks. Note:- (I) Payment will be made as per actual work done on pro rata basis, if required depth is not available at site. (II) If the depth of trench is not uniform in a span of 100 mtr.or shorter length, if site condition demands along the cable run minimum depth will be taken for that particular stretch for payment. " | — | — | — | 21,95,550 | |
| — | 50.00 | — | — | ||
| Laying cables of different sizes as per cable route plan approved by Railway and meggering of all main & tail cables as per technical specification of tender. ii)2 core to 12 core signalling cable | — | — | — | 5,87,846 | |
| — | 50.00 | — | — | ||
| Supply of Door lock switch.Inspection-Consignee | — | — | — | 1,12,100 | |
| — | 200.00 | — | — | ||
| "Supply of Timing belt as per RDSO Spec no. RDSO/SPN/208/2012 (ver 2.0) with latest amendment for lifting barrier pedestals-277L Make- AEW/Urban of ELB.Inspection-RDSO" | — | — | — | 2,82,674 | |
| — | 500.00 | — | — | ||
| "Supply of Timing belt as per RDSO Spec no. RDSO/SPN/208/2012 (ver 2.0) with latest amendment for lifting barrier pedestals-300L Make- Global of ELB.Inspection-RDSO" | — | — | — | 7,06,685 | |
| — | 500.00 | — | — | ||
| "Supply of Timing belt as per RDSO Spec no. RDSO/SPN/208/2012 (ver 2.0) with latest amendment for lifting barrier boom rest-100L for ELB.Inspection-RDSO" | — | — | — | 7,06,685 | |
| — | 5.00 | — | — | ||
| Supply of Spare parts of Electrically operated Lifting Barrier (ELB) as per spec. no. RDSO/SPN/208/2012 ver. 2.0 or latest. PMDC MOTOR,110V AC//90W/1500 RPM suitable for ELB.Inspection-RDSO | — | — | — | 85,515.4 | |
| — | 150.00 | — | — | ||
| Supply of Spare parts of Electrically operated Lifting Barrier (ELB) as per spec. no. RDSO/SPN/208/2012 ver. 2.0 or latest. BOOM LOCK PMDC MOTOR,110V AC/ 40W suitable for ELB.Inspection-RDSO | — | — | — | 4,75,656 | |
| — | 100.00 | — | — | ||
| Supply of Spare parts of Electrically operated Lifting Barrier (ELB) as per spec. no. RDSO/SPN/208/2012 ver. 2.0 or latest. BOOM LOCK PMDC MOTOR,110V DC/40W suitable for ELB.Inspection-RDSO | — | — | — | 3,17,104 | |
| — | 50.00 | — | — | ||
| Supply of Spare parts of Electrically operated Lifting Barrier (ELB) as per spec. no. RDSO/SPN/208/2012 ver. 2.0 or latest. Heitz Magnetic Boom lock arrangement, 110V AC/40W suitable for ELB.Inspection-RDSO | — | — | — | 1,58,552 | |
| — | 150.00 | — | — | ||
| Supply of Spare parts of Electrically operated Lifting Barrier (ELB) as per spec. no. RDSO/SPN/208/2012 ver. 2.0 or latest. POWER CONTACTORS/RELAY FOR MOTOR, 110V AC, MAKE SCHINDER TELEMECHANIQUES OR SIMILAR suitable for ELB.Inspection-RDSO | — | — | — | 4,33,939.5 | |
| — | 100.00 | — | — | ||
| Supply of Spare parts of Electrically operated Lifting Barrier (ELB) as per spec. no. RDSO/SPN/208/2012 ver. 2.0 or latest. LIMITING SWITCHES, MAKE SIEMENS/ JAJBALAJI (CONSISTING OF 3 LIMIT SWITCHES REQUIRED FOR EACH BARRIER MAIN SHAFT) suitable for ELB.Inspection- RDSO | — | — | — | 4,10,692 | |
| — | 50.00 | — | — | ||
| Supply of Spare parts of Electrically operated Lifting Barrier (ELB) as per spec. no. RDSO/SPN/208/2012 ver. 2.0 or latest. LIMITING SWITCHES perpendicular wheel for boom rest suitable for ELB.Inspection-RDSO | — | — | — | 2,05,346 | |
| — | 100.00 | — | — | ||
| Supply of Spare parts of Electrically operated Lifting Barrier (ELB) as per spec. no. RDSO/SPN/208/2012 ver. 2.0 or latest. PUSH BUTTON ELEMENTS suitable for ELB.Inspection-RDSO | — | — | — | 52,537 | |
| — | 100.00 | — | — | ||
| Supply of Spare parts of Electrically operated Lifting Barrier (ELB) as per spec. no. RDSO/SPN/208/2012 ver. 2.0 or latest. Balaji switch Head Lock.Inspection-RDSO | — | — | — | 59,000 | |
| — | 100.00 | — | — | ||
| Supply of Capacitor with capacitance of 1.5 to 2.2 microfarad with a minimum operating voltage of 400V AC. These are generally metallized polyester capacitors for ELB 110V AC.Inspection-Consignee | — | — | — | 88,500 | |
| — | 200.00 | — | — | ||
| Supply of LED-110VDC/AC for Control Panel of ELB.Inspection-Consignee | — | — | — | 1,10,000 | |
| — | 1000.00 | — | — | ||
| Provision of Boom welding at LC Gate. | — | — | — | 7,90,000 | |
| — | 500.00 | — | — | ||
| Excavation, trenching, earth work and reinstatement of track while track crossing. | — | — | — | 86,815 | |
| — | 500.00 | — | — | ||
| Excavation of trench less trench /manual boaring (size upto 110 MM) upto a depth of minimum 1.0 Meter along with dia HDPE/ DWC pipes and its accessories, all other items which will be required for laying of cable through HDPE/DWC pipes as per requirement at site. | — | — | — | 4,50,385 | |
| — | 7000.00 | — | — | ||
| Transportation of HDT machine with accessories including handling of stores materials, preparation of site and boring for placing of 110 MM dia HDPE/DWC pipes for crossing of S&T cable together at Bridges/ Culverts/Track/ pucca road Crossing, Boring trench shall be minimum 3 Mtr below the river bed and 1 Mtr below the Track/Road /Pucca Road crossing area. This includes supply of HDPE/DWC pipes and accessories, cost of fuels & all other items which will be required for laying of cable through it. The work shall be executed as per instruction of site engineer.- (a) Boring upto length 150 Mtrs. | — | — | — | 92,24,110 | |
| — | 2000.00 | — | — | ||
| Transportation of material by 15 MT capacity truck. | — | — | — | 2,36,820 | |
| — | 10.00 | — | — | ||
| Loading & unloading of heavy S&T materials in 15 MT Truck. | — | — | — | 1,05,362.8 | |
| — | 20.00 | — | — | ||
| Casting, Concreting and Curing of foundation and erection for full apparatus case(GKP- type) as per DRG No. SGW/MGS/L1/91 including cost of all materials required for fixing holding down bolts, casting, concreting and fixing of "E" type lock. Note:- i)The contractor will provide holding down bolts. ii) Bottom of appratus cases should be filled with sand and the top surface covered with masonry work and neat cementing. | — | — | — | 1,42,625.4 | |
| — | 20.00 | — | — | ||
| Fixing, wiring of terminal strips, Bakelite strip, transformers, relays fuses with base and supply and fixing of shelves for full apparatus case with termination earthing of cable and wiring with lettering as required including supply of wires and miscellaneous materials, sand filling and plastering over sand filling per location.(All materials except transformers, relay, terminal strips, Bakelite strip and fuses with base to be supplied by the contractor.) | — | — | — | 89,865.2 | |
| — | 80.00 | — | — | ||
| "Supply of E-type lock without key,spec.no.IRS-S-30,Drg. no. S-3376/M key-S-3377/M. Individual number of miniature E locks and Normal size of locks required at site to be decided by the site engineer as per site requirement.Inspection-RDSO" | — | — | — | 1,31,999.2 | |
| — | 80.00 | — | — | ||
| Key for E type lock supplied above. Inspection-Consignee | — | — | — | 19,820.8 | |
| — | 250.00 | — | — | ||
| Miniature lock.Inspection-RITES | — | — | — | 3,50,552.5 | |
| — | 20.00 | — | — | ||
| Supply of full size location box as per design of GKP signal workshop. Inspection-RITES | — | — | — | 5,42,493.4 | |
| — | 30.00 | — | — | ||
| Filling earth around location box/signal post for a width of 0.5 m on all sides, upto a level of 150 mm below the foundation top.This work includes consolidation of earth by watering. | — | — | — | 6,748.5 | |
| — | 200.00 | — | — | ||
| Supply of electrical key transmitter for crank handle interlocking arrangement siding control, LC Gate control as per yard diagram, approved circuit diagram and IRS Spec.No.IRSS-21/64.and IRS S-23 (latest) Inspection-RDSO | — | — | — | 19,98,102 | |
| — | 200.00 | — | — | ||
| Installation of electrical key transmitter on suitable bracket as per inspection of site engineer. ,wiring and testing of electrical key transmitter. | — | — | — | 31,17,510 | |
| — | 40.00 | — | — | ||
| Supply of CO2 Fire extinguisher 4.5 kg capacity confirming to IS 15683: 2018 or latest with ISI mark provided with all fittings and accessories. Inspection-Consignee | — | — | — | 2,11,240 | |
| — | 50000.00 | — | — | ||
| Printing, segregation, packing and supply of Ferrule along with ferrule tie, for functional description details of cable termination on CT rack. The details of CT rack shall be provided by railway in digital form. Size and colour of ferrule shall be as per the Railway policy and work is to be done as per the instruction of site engineering (Unit-Per ferrule)Supply Inpection-Consignee | — | — | — | 2,62,500 | |
| — | 15.00 | — | — | ||
| Electronic LC gate telephone systems with voice recorder as per RDSO Spec.no. RDSO/SPN/TC/51/ 2011 rev 1.0. a) Master telephone with in-built voice logger. Inspection-RDSO | — | — | — | 4,55,609.85 | |
| — | 60.00 | — | — | ||
| Electronic LC gate telephone systems with voice recorder as per RDSO spec.no. RDSO/SPN/TC/51/ 2011 rev 1.0. b) Slave telephone Inspection-RDSO | — | — | — | 4,17,884.4 | |
| — | 75.00 | — | — | ||
| Electronic LC gate telephone systems with voice recorder as per RDSO spec.no. RDSO/ SPN/TC/51/ 2011 rev 1.0. c) 24v power pack with mf battery-7AH for LC gate telephone .Inspection-RDSO | — | — | — | 6,46,081.5 | |
| — | 100.00 | — | — | ||
| Supply of earth electrode material to be procured as per E.Rly sketch No. SGW/T/3/G/8/89. Inspection-RITES | — | — | — | 1,99,272 | |
| — | 100.00 | — | — | ||
| Installation of Earth Electrode including MS flat for clamp etc. signalling equipments as lever frames, apparatus cases, signal, relay rack, block instrument etc. | — | — | — | 4,44,908 | |
| — | 15.00 | — | — | ||
| Supply, Transportation, installation, testing & commissioning of Hooter cum Strobe as per RDSO/SPN/217/2021 ver3.0, or latest with base inbuilt isolator with protection category of IP42.Supply-Inspection-RDSO | — | — | — | 1,28,964.9 | |
| — | 10.00 | — | — | ||
| Supply of basic material to construct unit Maintenance Free Earth for Single Earth consisting as per Spec. Nos. RDSO/SPN/197/2016 Ver 1.0 or latest, bonding connections drawing Nos. SDO/ RDSO/E&B/002 or latest are as under,(a) Copper bonded steel electrodes of 3.0 m long, 17.0 mm diameter with copper bonding thickness of min 250 micron and UL listed and marked -1 Nos. (b) Earth Enhancement compound supplied in sealed bags of min 30-35 Kg.- 1 Nos. (c ) Copper Strip of 200mm x 25mm x6mm to exothermically welded to Earth electrode- 1 Nos.(d) Copper Strip of 300mm x 25mm x 6mm (MEEB) - 1 Nos.(e) Copper Strip of 150mm x 25mm x 6mm (SEEB)- 1 Nos. It also includes supply of (i) 35 Sq. mm Multi- strand Single Core PVC insulated Copper Connector as per IS:694 for connecting Main Earth Electrode to MEEB in the equipment room in duplicate.-10 meter (ii) 16 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting MEEB to SEEB and SPDs to MEEB.-10 meter (iii) 10 Sq. mm Multi-strand Single Core PVC insulated Copper Connector as per IS:694 for connecting various equipment to SEEB- 10 meter. Inspection-RDSO | — | — | — | 2,08,820 | |
| — | 10.00 | — | — | ||
| Installation of Single Maintenance Free Earth pit as per RDSO Drawing Nos. SDO / RDSO/ E&B/001 which includes the following,a) Digging /Auguring/Boring of single earth pit of 100mm to 125mm dia. to the depth of approx. 3 meter. b) Insertion of 3.0 meter electrode and penetrating it minimum 150 mm by pushing gently with sledge hammer where the natural soil is assumed. (c) Filling of earth pit with Earth Enhancement Compound (EEC) in slurry form and backfilling. (d) Carrying out exothermic weld connection on single earth electrode to a copper tape of 200 x 25 x 6 mm. (e) Carrying out exothermic weld connection on the copper tape of 200 x 25 x 6 mm on Earth Electrode for connecting two 35 Sq. mm cables for redundancy. (f) The exothermic welding material for bonding the earth system shall be procured from RDSO approved firms, which includes graphite modules, clamps, weld metal powders etc. (g) The dimension of the chamber will be of 300 x 300 x 300 mm (inside dimension) of RCC with 50mm thick and fine finish, Inspection chamber should be as per IEC 62561-5 or latest. The top RCC cover size shall be 400 mm X 400 mm X 50mm. The date of testing and earth resistance value shall be written on the cover with black base with yellow paint or as per instruction of site engineer. | — | — | — | 65,870 | |
| — | 4.00 | — | — | ||
| Alteration | Per | — | — | ||
| Modification/Alteration in existing EI (Electronic Interlocking) as per latest RDSO guidelines/TAN. It includes:Design and modification in existing Interface and Interlocking circuits and logic of EI system including modification in the VDU (Video Display Unit)/LCP (Local Control panel)/CCIP (Control cum Indication Panel), Maintenance terminal (MPC), Data Logger, Relay rack wiring. The complete work should comply with the latest RDSO specifications and guidelines and as per approved SIP and circuit diagrams. All the material (Interface cards/ relays/ wiring material/ connectors/ fuses/ communication devices etc.) shall be provided by the contractor. The work also includes the supply of modified Selection table, Interface Circuits, VDU/LCP/CCIP diagram etc. to suit the modified SIP. It also includes the carrying out of FAT, SAT (as applicable) jointly with Railways and satisfactory commissioning. All plans/drawings/ circuits etc. should be prepared on AUTOCAD, soft copy to be supplied on Pen Drive and 06 sets of hard copies also to be supplied. (Alteration in RCC to be considered) Alteration involving modification from 11 upto 20 routes. | — | — | — | 1,20,12,323.4 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
MasterTenderDocumentSig-2026-8.pdf
ATTACHMENT
ACSGCCcorrectionsliplatest.pdf
ATTACHMENT
ECRJPOregardingprocedureforundertakingearthworkdiggingworktrenchingworkinthevivinityofsignallingtelecomandelectricalcables2.pdf
ATTACHMENT
GCC_April-2022_2022__GCC-2022_POLICY_27.04.22.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .