Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC MHN 284 DRIVER HILL VASCO DA GAMA GOA 403 802 | SOUTH GOA | GOA | 403802 | ₹1.3 Cr Quoted ₹1.4 Cr | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹1.4 Cr+₹1.4 L (1.05%)Rejected-AOC FLAT NO 4 VIRGINIA CO OP HOUSING SOCIETY AIR PORT ROAD CHICALIM VASCO DA GAMA GOA 403 711 | SOUTH GOA | GOA | 403711 | ₹1.4 Cr+₹1.4 L (1.05%) | L2 | Rejected-AOC Higher Bidder |
| 3 | L3₹1.5 Cr+₹15.2 L (11.2%)Rejected-Finance | ₹1.5 Cr+₹15.2 L (11.2%) | L3 | Rejected-Finance Higher Bidder |
| 4 | L4₹1.7 Cr+₹31.1 L (22.8%)Rejected-Finance | ₹1.7 Cr+₹31.1 L (22.8%) | L4 | Rejected-Finance Higher Bidder |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
10 Sept 2021, 6:00 pmClosed
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIRS TO TU HANGAR NO 1 BUILDING NO P452 AT NAY GOA UNDER GE NW VASCO
2021_MES_438572_1
85416/E8
Open Tender
Civil Works
Item Rate
270 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹1,000
Yes
GE NW VASCO
₹2.2 L
Yes
9 Nov 2021
26 Apr 2021
13 Sept 2021
26 Apr 2021
10 Sept 2021
27 Aug 2021
Amount
Schedule 'A' Part I - B/R portion
Chipping removing carefully concrete work by low impact hammer, breakar without damaging the structure & cleaning and disposal of debries out side the premises etc complete all as specified and as directed. Note : Hard concrete should not be removed by force.
Clean existing reinforcement with wire/ rotary wire brush making the surfaces free from loose material dirt etc complete, Applying Rust of 100, rust remover cum passivator of Sika India Pvt Ltd or equivalent to Dr Fixit / Fosroc/ BASF on the rebars, including cleaning the reinforcement, wire brushing to remove loose rust spalls, with time interval of 6 hour between the coats and applying protective coating Sika Fria zinc R of Sika India Pvt Ltd or equivalent to Dr Fixit / Fosroc/ BASF complete all as specified and as directed.
M&L for carry out application of corrosion inhibiting Impregnation Sika Ferrogard 903 or equivalent of Dr Fixit / Fosroc/ BASF on concrete surface. Sika ferrogard 903 based on organic compounds penetrates to a virtual extent of 100mm, through pores of concrete and form a protective monomolecular layer on the surface of the Reinforcing steel, it should complies to EN-1504-9 method 11.3 (applying inhibitor to the concrete). The coating should not alter water vapour diffusion properties of the concrete. The coating should protects cathodic (principal 9) and anodic (Principle 11) zones of reinforcement complete all as specified and as directed.
Providing and applying Epoxy resin Bonding agent Sikadur 32 LP or Equivalent of Dr Fixit/Fosroc/BASF prior to application of any type of mortar plaster confirming to ASTM - C - 881-78 type II, Grade 2, class B + C to ensure bond between old concrete and new concrete complete all as specified and as directed.
M&L for Rebuilding the section of damaged RCC elements to its original size in average thickness of 30mm not exceeding 15mm in each layer by hand or spray application by providing and applying Sika Mono Top-122 F single component or equivalent of Dr Fixit/Fosroc/BASF (Epoxy latex additives) fibre reinforced,dual shrinkage compensated trowalable,thixotropic cementitious structural repair mortar on exposed concrete surface as per technical specification. Material should have Compressive strength of 50 Mpa on 28th day and 20 Mpa in 24 hour,tensile strength in flexural >- 6 Mpa in 7 days and tensile adhesion strength of 8 Mpa in 7 days with a consumption of water: powder ratio of 0.16, and mixing ratio of water : powder 0.15 - 0.16 by weight ( 4.5 - 4.8 It of water per bag), with a consumption of 2.2 kg per sqm per mm complete all as per manufacturer instruction and as directed.
M&L for Drilling and fixing Non returnable valve (NRV Nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep hole in structural members at the interval of 500mm center to center in staggered manner or as directed by Engineer-In-Charge in RCC structural element. Work shall be carried out as under:- (i) Cleaning of holes - Clean the holes by air blower prior to fixing nozzles (ii) Fixing of nozzles - Insert 12mm dia Non returnable valve (NRV) Nozzles in cleaned holes. External end of nozzles to be machined to receive outlet of grouting gun. Fix it inside the hole by applying thixotropic structurual epoxy adhesive Sikadur 31 IN (or equivalent of Dr Fixit/ Fosroc/BASF ) to ensure complete sealing. Cure the system for minimum 12 hrs. (iii) Cutting of nozzles - Cut the nozzles by chiser after completion of grouting without damaging structural elements.
M&L for injecting at site, cement slurry grout, in the ratio 1:2 (1-Cement, 2-Water) including expanding non shrink grout admixture Sika Intraplast NN or Sika Intraplast N - 200 or Equivalent of Dr Fixit / Fosroc / BASF as specified 500gm / 50 Kgs bag. Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 0.5 Kg/sqcm etc. complete till the grout mix flows out from the nozzle indicating complete filling of grout in holes drilled all as specified and as directed. (for repair to slab)
M&L for Grouting injecting Sikadur®-52 LP of Sika India PVT LTD or Equivalent of Dr Fixit/Fosroc/BASF in two parts, low viscosity injection resin, based on high strength epoxy resin by pressure and using pressure epoxy injector with accessories till nozzle refused to accept the grout including mixing of grout. Seal the nozzle with thixotropic epoxy putty after the refusal of grout material from nozzle. Note: Leakage through other nozzle or cracks are required to monitored while grouting and such points to be sealed as and when required without any extra cost. Mixing of materials: Mixing of material components (part a & b) in the required quantities as per manufacturer's instruction by weigh batching. Grouting maintain the pressure at exit (0.5 to 1.0 kg/sqcm) by monitoring pressure gauge at exit. Repeat the process for all the nozzles (for Beam and columns)
Providing and applying jacketing around damaged member of columns providing and casting with ready to use non shrink, cementitious free flow micro-concrete SikaRep Microcrete-4 or equivalent of Dr Fixit / Fosroc / BASF at level, having compressive strength > 60 N/sqmm (28 days) according to ASTMC 1107-99 strength including providing and fixing of watertight foam faced finish shuttering of minimum 18mm thickness and drilling holes and fixing shear anchor with Sika Anchor fix 2+ Tropical, supporting formwork, all lead lift, mixing, placing, de-shuttering, leveling the surface by grinding off cementitious slurry or cementitious joints differences if any to satisfaction of Engineer-in-charge and curing. Notes: Reinforcement shall be measured and paid separately. Rates including jacketing, formwork and micro concrete.
Replacement of steel reinforcement with TMT CRS bars of appropriate size where 20% of cross section is reduced including dismantling of rusted steel including application of rust converter Sika Rustoff 100 or equivalent of Dr. Fixit / Fosroc/ BASF and applying coating Sika Friazinc or equivalent of Dr. Fixit / Fosroc / BASF complete all as specified and as directed.
S&F hard drawn steel wire fabric cut to length bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm dia not exc. 4 Kg/sqm all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness, including cover fillets all as specified and as directed.
Providing & Fixing of Armstrong Mineral Fibre Acoustical Suspended Ceiling System with ANF (Board) edge tiles with Armstrong 24mm exposed grid. The tiles should have Humidity Resistance (RH) of 90%, NRC 0.5, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm , suitable for Green Building application, with Recycled content of 34%.The tile shall be laid on Armstrong Prelude38 with 24 mm wide T - section flanges colour white having rotary stitching on all T sections i.e. the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15.34Kgs/m2 & pull out strength of 100Kgs. The T Sections have a Galvanizing of 90 grams per m2 and need to be installed with Suspension system. The Tile & Grid system used together should carry a 10 year warranty all as specified and as directed..
Dismantling/Taking out existing hessain base felt of any other existing water proofing treatment from roof including cement plaster and exposing the top surface of RCC slab including removing dust, dirt and washing the roof and removing the dismantled debris to a distance exceeding 200 m but not exceeding 3000m spread and levelled all as specified and as directed.
Providing 10mm thick plaster in cement mortar 1:4 mixed with 3% integral water proofing compound over roof top surface finished to even & smooth without using extra cement all as specified and as directed. Note :- Integral water proofing compound shall be measured and paid seperately
M&L for applying evenly & priming with oil bound bituminous primer at 0.4 Ltr per sqm for water proofing treatment all as specified and as directed.
M&L for APP based polymeric membrane minimum weighing 3Kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) and on primed surface by forced application complete all as specified and as directed.
Taking down cement plaster on brick or stone walls,ceilings etc. including raking out joints, hacking for key, scrubbing down with water, etc all as specified and as directed.
M&L for rendering 15 mm thick on block masonry surfaces or other than fair faces of brick work in cement mortar 1:4. finished to even and smooth without using extra cement all as specified and as directed.
M&L for rendering 15 mm thick cement plaster on concrete solid block walls in two coats first coat of 10 mm in cement mortar 1:4 & 2nd coat of 5mm in cement mortar 1:4 mixed with 3% integral water proofing compound finished to even & smooth without using extra cement. Note :- Integral water proofing liquid shall be measured and paid seperately.
M&L for rendering 5 mm thick cement plaster on ceiling in cement mortar 1:3 mixed with 3% integral water proofing compound finished to even & smooth without using extra cement. Note :- Integral water proofing liquid shall be measured and paid seperately.
Supply only water proofing compound all as specified and as directed.
M&L for preparing new plastered ceiling surfaces and applying two coats of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling all as specified and as directed.
M&L for preparing new plastered wall surfaces and applying two coats of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on wall all as specified and as directed.
M&L for complete removal of existing treatment and preparing old plastered ceiling surfaces and applying two coats of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on ceiling all as specified and as directed.
M&L for complete removal of existing treatment and preparing old plastered wall surfaces and applying two coats of oil bound distemper over chalk whiting, on plastered surfaces, preparatory to distempering, after applying 3mm thick wall care putty on wall all as specified and as directed.
M&L for preparation of old/new surface of wall and applying two coats of water proofing treatment by using SIKAGARD XT or equivalent @ 5 Sqm per Ltr for first coat and 6 Sqm per Ltr for second coat (alongwith suitable pigments for colour as directed by Engineer-in-Charge) all as specified in manufacturer's instructions and to be applied through applicator of authorised manufacturer with 5 Years guarantee all as specified and as directed.
Dismantling floor/wall tiling including cement mortar (bedding but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and as directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. all as specified and as directed.
M&L for Granite 20 mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite all as specified and as directed.
M&L for machine cut kota stone slab flooring 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Demolition of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and as directed.
M & L for 75 mm thick cement concrete type C2, 1:3:6 using 40 mm graded stone aggregate in sub base of internal flooring/plinth protections, etc. all as specified and as directed.
M&L for screed bed or bedding layer of mortar 20 mm thick cement plaster 1:4 for laying floor finished to receive floor tiles all as specified and as directed.
M&L for Vitrified Ceramic tiles of light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors/skirtings etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed.
M&L for rendering 10mm thick in 1:6 cement mortar on fair faces of block work or concrete surfaces to receive glazed tiles all as specified and as directed.
M&L for non - skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and as directed.
M&L for Glazed coloured ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match all as specified and as directed.
M&L for Acid resistant tiles 15mm thick vitreous ceramic, unglazed, set, jointed and pointed in chemical mortar, resin type, in floors/walls all as specified and as directed.
Taking down chowkat or frames exc 1.5 sqm but n. exc 4 sqm each without taking of shutters from the frame and removing to store all as specified and as directed.
S&F factory made solid panel Prelam PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and both face prelam PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of prelam PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S&F factory made solid PVC moulded door designer shutter 30 mm thick comprising of 25 mm thick solid particle board core in centre core, with 2,4 or 6 raised panel design with 2 mm thick moulded prelam PVC sheet on both face all as specified and as directed.
S&F factory made 100% solid wood plastic (WPC) Decorative Door Frame, single rebate of size 95 mm x 45 mm made from wood plastic composite (single extruded process) material with density 780 kg/cum complete all as specified and as directed.
S&F butt hinges medium weight stainless steel 100mm size all as specified and as directed.
S&F Extruded stainless steel handles, fabricated type, 100 mm grip size all as specified and as directed.
S&F stainless steel, barrel tower bolts of extruded section and fixed 150mm size all as specified and as directed.
S&F stainless steel, sliding door bolt 250mm with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy all as specified and as directed.
M&L for preparation of old wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint (ordinary tint) over a coat of pink primer all as specified and as directed.
Taking down chowkat or frames n exc 1.5 sqm each without taking of shutters from the frame all as specified and as directed.
S&F powder coated aluminium door and window shutter and frame any type (sliding or openable) and other similar work etc 60 micron powder coated section, including all necessary roller wheels for window, cleats , handle, door stoper locking arrangement and arrangements to received glass/ prelaminated particle board with aluminium beading and stainless steel screw including cost of rubber gasket beadings etc complete sealing between frame & wall with epoxy sealing compound. (The weight of rubber gasket beading shall not be measured with the weight of aluminium shutters, glass and prelaminated particle board shall be measured and paid seperately) All sections as approved by GE.
S&F Powder coated aluminium grill, made out of 10mm dia rod fixed with and including stranded aluminium frame of 'F' section of size 23.4x15.3x1.4 mm thick all as per manufacturer's instructions complete all as specified and as directed.
S&F 4mm thick frosted sheet glass ordinary quality exceeding 0.5 sqm each pane all as specified and as directed.
S&F 4mm thick sheet glass ordinary quality exceeding 0.5 sqm each pane all as specified and as directed.
S&F solar control film 50 micron reflective type mirror finish/mirror jet black type all as specified and as directed.
S & F floor door stopper of stainless steel, with hard drawn steel spring, fixed in floor with overall length of cover plate 140 mm all as specified and as directed.
S&F aluminium (extruded section) body door closer hydraulically regulated designation No 3, universal type suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and as directed.
Taking up or down steel water tubing and connections including cleaning for refixing or removing to store 20 mm dia all as specified and as directed.
All as per Item No 57 here in before, but of 25 mm dia all as specified and as directed.
Supplying and laying of 20 mm dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified and as directed.
All as per Item No 59 here in before, but of 25 mm dia all as specified and as directed.
S&F in repairs 32 mm dia Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc all as specified and as directed.
S&F in repairs 50 mm dia Low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc all as specified and as directed.
S&F in repair PVC Connections 15mm size with PTMT nuts of length 450mm all as specified and as directed.
S & F in repairs 75 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls all as specified and as directed.
S & F 75 mm bore PVC (SWR) bends of any radius all as specified and as directed.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) all as specified and as directed.
S & F 200 mm bore PVC (SWR) Soil, waste and vent pipes single socketed in any length with rubber ring joints fixed to walls including all connecting bends all as specified and as directed.
S&F in repair Stop valves fancy type, chromium plated 15 mm dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions all as specified and as directed.
S&F in repairs Wash basins 550x400mm vitreous china (flat back type) any size including cutting for and pinning in end of brackets for erecting stand but exclusive of fixing of supply and waste pipe but including waste fittings all as specified and as directed.
S&F in repairs chromium plated fancy type Bib taps 15 mm dia, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified and as directed.
S&F Pillar taps fancy type of 15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe all as specified and as directed.
S&F PVC (SWR) floor trap 75 mm, plain with CP grating including joining and solvent cement complete all as specified and as directed.
S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white including seat cover (excluding fixing bolts, flushing cistern and flush pipe) all as specified and as directed.
S&F in repairs Vitreous China half stall urinals, white complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, magnum urinal spreader, pointing around urinal back in cement; flush pipe, grating and Union for discharge pipe all as specified and as directed.
S&F in repair PVC valveless, syphonic action type flushing cistern, low level , white, with inlet ball valve, float and handle including brackets 10 litres capacity all as specified and as directed.
S&F in repairs Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms/ 40mm-270 gms) all as specified and as directed.
S&F for hand shower (Health faucet) dia 8mm 1 mtr long flexible tube and wall hook all as specified and as directed.
S&F in repairs stainless steel Tubular towel rail, 20mm dia, D type, 60cm long between flanges all as specified and as directed.
S&F in repairs Soap dish, of material brass with glossy finish all as specified and as directed.
S & F Glass shelf with Sheet Glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long all as specified and as directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc all as specified and as directed.
S & F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete confirming to Fe 410 - W (Gde- E- 250) quality - A all as specified and as directed.
Dismantling plain or corrugated AC sheeting any gauge, thickness in roof coverings all as specified and as directed.
Fixing only Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed. (Except Sheet)
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed.
S & F Mild steel roof trusses (framed), Trussesd, purlins, crane grantries, rails and framings and heavy bracket framing (Beam,tee, angle, channel or flat sections) confrming to Fe 410-W including cleats,distance pieces etc all as specified and as directed.
M&L for preparation of new steel surface and applying one coat of red oxide zinc chrome primer and two coats of Epoxy anticorrosive paint over 10 cm width or girth all as specified and as directed.
M&L for preparation of old steel surface and applying one coat of Epoxy anticorrosive paint over 10 cm width or girth all as specified and as directed.
Forming jambs, etc., to openings (to foregoing item), with stone supplied by MES including cutting, toothings and properly bonding into old work, including facing and pointing (if necessary) to match existing work, complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with bead all as specified and as directed.
M&L for dismantling water tanks of 1000 ltrs capacity all as specified and as directed.
M&L for 1000 ltrs Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) ISI Marked, two layer hoisted and fixed in position all as specified in SSR Part I including brass float valve, GI coupling, inlet/outlet connection pipe all as specified and as directed.
Demolition of Reinforced Cement Concrete of any description and in any position not otherwise specifically provided for all as specified and as directed.
M&L for mild steel deformed bars or TMT CRS bars 6mm to 8mm dia, cut to length, bent to shape required including cranking bending spirally & binding with and in including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and as directed.
M&L for reinforced Cement Concrete Type A1, 1:1.5:3 using 20 mm graded stone aggregate for slabs suspended on walls, beams and columns, in floors, roofs, landings and in shelves and the like including necessary form work all as specified and as directed.
S&F in repairs Collapsible steel gates, top hung,consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and as directed.
M & L for running welding in repairs thickness of metal to be welded exceeding 6 mm but not exceeding 9mm all as specified and as directed.
M&L for welding in repairs thickness of metal to be welded exceeding 9 mm but not exceeding 20 mm and exc 2.5cm but n exc 5cm in length all as specified and as directed.
M&L for overhauling the bottom wheel and existing gear system of bottom wheel of hanger steel door including dismantling from the steel door and refixing in the same position including derusting cleaning and greasing of wheel & bearings without taking down door complete all as directed to make in serviceable condition.
M&L for overhauling the top wheel including derusting , cleaning and greasing including dismantling and opening of bearing and making serviceable for smooth functioning of door complete all as directed without taking down shutter .
S&F bottom wheel of hangar in cast iron including bush bearing axle and all other necessary items as per the existing design after taking down the shutter including replacement of existing wheel with new wheels. all as specified and as directed.
All as per Item No 103 here in before, but for top wheel all as specified and as directed.
M&L for taking out old bolts from any type of roof/wall cladding and sealing with one bitumen and one curved GI washer on either side and provision of new J/L hooks/6mm dia GI bolts and nuts/self taping screws all set in stiff white lead all as specified and as directed.
Demolition of stone /boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles all as specified and as directed.
M&L for pre - cast cement concrete block masonry type C-5,with solid blocks built in cement mortar 1:6 all as specified and as directed.
S&F stainless steel railing of height 0.9m and grade SS T-316 including all accessories with horizontal support of stainless steel and fitting to staircase, varandah, balconies etc all as per manufacturer’s instruction and as directed.
Schedule 'A' Part II - E/M portion
M & L in replacement of point wiring with 1.5 Sqmm (nominal area) FRLS PVC insulated unsheathed multistranded copper conductor cable in and including PVC casing caping ISI marked including fittings and accessories with continues PVC insulated copper cable with copper conductor of same size as in phase/neutral/earth cable connecting to common earth dolly including (metal box, PVC modular plate for mounting swiches,socket,regulator etc) complete all as specified and as directed for the following:
a) Light , fan point controlled by one way switch
b) 5 Amp Socket point on same board
All as per item No-109 here in before, but for 5 Amp point on independent board all as specified and as directed.
S & F in repairs modular switch one way 6 amps all as specified and as directed.
S & F in repairs fan step regulator, 120W - 2 module all as specified and as directed.
S&F ceiling rose 3 terminal 230 volts, PVC polycarbonate, isolated body completed all as specified and as directed.
S & F in repairs modular sockets 6A- 2/3 pin combined 2 module, all as specified and as directed
M&L for point FRLHS wiring with cable size 2.5 Sq mm nominal area PVC insulated and unsheathed cable single core multistranded, copper conductor in PVC casing caping ISI marked for one 3 pin, 15 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 2.5 sqmm all as specified and as directed.
S & F in repairs modular sockets 6A/16A- 2/3 pin combined 2 module, all as specified and as directed
S & F in repairs modular switch one way 16 amps all as specified and as directed
Taking down Ceiling /Exhaust fan, sealing cable end, dismantling blades and removing fan and blades to store all as specified and as directed.
M&L for painting of ceiling/exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc. all as specified and as directed
Supply & fix ceiling fan 1200 sweep, 50 W, 340 RPM suitable for air delivery of 210 CMM alongwith downrod of 266-300 mm length complete all as specified and as directed.
S & F MCB TPN 63 Amps 415 volts all as specified and as directed
S & F MCB SP 6 to 32 Amps 240 Volts all as specified and as directed.
S & F MCB SPN 6 to 32 Amps 240 Volts all as specified and as directed.
S & F RCCB 4 Pole 100 mA 63 Amps all as specified and as directed.
S & F vertical MCB DBs VTPN 4 Way sheet steel, phospetised, powder coated with 200 Amps rated bas bar double door, 415 Volt all as specified and as directed all as specified and as directed.
S & F MCB DB SPN 12 ways sheet steel enclosure, phospetised, powder coated with double door, 415 Volt all as specified and as directed.
S & F vertical DBs VTPN 8 way with provision for FP MCCB (V -TEC) N3 frame upto 250 Amp in 16 KA as incomer sheet steel, phospetised, powder coated with 200 Amps rated bas bar double door all as specified and as directed
S & F MCCB 4 pole, 415 volt, fixed type, 160 amps with breaking capacity 25 KA complete all as specified and as directed.
Supply and fix in repair Hanger obstruction light fitting Aviation yellow painted die-cast aluminium alloy housing, red coloured polycarbonate dome and accessories LED type suitable to 230 V AC protection weather proof IP66as per IS2147 sealed against water and dusts complete all as specified and as directed.
M & L for sub main wiring with 2 run of FRLHS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 2.5 sqmm alongwith one run of FRLHS PVC insulated & unsheathed copper conductor of nominal cross sectional area 2.5 sqmm as earth continuity conductor drawn through PVC Casing Caping, including accessories fixed on wall/ceiling all as specified and as directed including making good of disturbed surfaces area. Note :- 02 run of 2.5 sqmm and 01 run of 2.5 sqm including 01 run of PVC casing/caping shall be measured as one length.
M & L for sub main wiring with 2 run of FRLHS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 4 sqmm alongwith one run of FRLHS PVC insulated & unsheathed copper conductor of nominal cross sectional area 4 sqmm as earth continuity conductor drawn through PVC Casing Caping, including accessories fixed on wall/ceiling all as specified and as directed including making good of disturbed surfaces area. Note :- 02 run of 4.0 sqmm and 01 run of 4.0 sqm including 01 run of PVC casing/caping shall be measured as one length.
M & L for sub main wiring with 2 run of FRLHS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6 sqmm alongwith one run of FRLHS PVC insulated & unsheathed copper conductor of nominal cross sectional area 6 sqmm as earth continuity conductor drawn through PVC Casing Caping, including accessories fixed on wall/ceiling all as specified and as directed including making good of disturbed surfaces area. Note :- 02 run of 6.0 sqmm and 01 run of 6.0 sqm including 01 run of PVC casing/caping shall be measured as one length.
M & L for sub main wiring with 4 run of FRLHS PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 10 sqmm alongwith one run of FRLHS PVC insulated & unsheathed copper conductor of nominal cross sectional area 2X 6 sqmm as earth continuity conductor drawn through PVC Casing Caping, including accessories fixed on wall/ceiling all as specified and as directed including making good of disturbed surfaces area. Note :- 04 run of 10.0 sqmm and 02 run of 2x6 sqm including 01 run of PVC caing/caping shall be measured as one length.
M & L for earthing complete with galvanized steel earth plate electrode of size 60cm x 60cm x 6mm thick, buried directly in ground vertically earth pit not less than 2.25 mtr deep below the ground level with top to edge of the plate n. less than 1.5 mtr below ground level connected to galvanized iron wire 4 mm as earthing lead by means of blots, nuts, check nut and washer of galvanized steel, including necessary earth work and excavation in any strata and PCC 1:3:6 type C2 chamber and RCC cover and light grade GI pipe 40 mm dia pipe of required length for protection of GI wire and water funnel and wire mesh with GI pipe medium grade 20mm dia etc complete all as per electrical plate No 3 of SSR part - I and all directed including connections and testing on completion. Note : GI earth wire upto 7.5 RM is included in the unit rate quoted.
S & F DB mounted MCB type indicating lamp single phase Red/Yellow/Blue all as specified and as directed
S & F LED aluminium batten with decorative end cap complete with retrofit T8 glass tube light 20 W 230 V all as specified and as directed.
S & F in replacement LED panel 2' X 2' recess mounting luminaire suitable for armstrong/grid/ Pop ceiling complete with separate electronic driver & high brightness SMD Leds complete all as specified and as directed.
M & L for Street light bracket made out of GI tubing 40 mm dia, light grade bend to shape suitable for above mentioned security light fittings with necessary MS clamps with one coat of anti corrosive primer and two coats of aluminium paint including nut, bolt, washers etc including taking out old unserviceable complete all as specified and as directed
Supply and fix 60 Watt LED street light with pressure die cast aluminium housing & toughened glass with IP-66 degree protection, individual LED's must have peanut lenses for better throw across & along the road with luminarie efficacy of greater than 100 lumen/Watt (Minimum lumen output of luminarie should be 6000 Lumens) The luminarie should have 5 KV surge protection, PF > 0.95, and total harmonic distortion of THD < 10%, voltage range of 140-280V should be provided. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specified and as directed.
Supply, laying and testing in replacement cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 3 core all as specified and as directed
Supply and lay cable XLPE insulated screended PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 95 sqmm 3.5 core all as specified and as directed
S & F Perforated cable Tray made out of GI Sheet of 1.6 mm thickness and 25/50 mm depth hot dipped in various width sizes including accessories like couplar plate, nut bolts, washers clamps, wall bracket up/down elbows, bends tees equal distances on wall/floor/through wall crossing and making good the surface, complete all as specified and as directed
S & F in repair cable junction boxes IP 66 protected “halogen free and weather proof” suitable for out door type ( with metric knockouts for cable entry) of size 139 x 119 x 70 mm incl necessary suitable size terminal connector single phase with neutral system mounted on saddles of suitable length and provision of aluminium cable lugs for incoming & outgoing LT cable connections with junction box fixing clamps made up of MS flat, nut and bolt on poles complete all as specified and as directed
Supply and fixing in replacement LED Flood Light 240W suitable for Hangers / industrial application, with secondary optics with pressure die-cast aluminium housing, and heat sink in aluminium , complete with all accessories ,lumen efficiency > 120 lm/w , CRI > 85% ,THD < 15% UL certified. The luminarie should have 5 KV surge protection, PF > 0.95. The manufactures LOGO must be embossed/Engraved in the housing of the luminarie. Manufactures to provide LM80 from source manufacturer and should have adequate testing facilities approved by ministry of science (Govt of India) to provide LM 79 report complete all as specified and as directed
M/S jvsr constructions
Ms Hari Deva Builders
M/s. R.S. LAWANDE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .