Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹5.8 LQualified Make: NA
Model: SPL-353 | Make: NA
Model: SPL-353 | L1 | Qualified | |
| 2 | L2₹6.0 L+₹19,845 (3.44%)Qualified Make: WIPRO
Model: wipro (N95001) 120 1 VALLANCHERRY GUDUVANCHERRY KANCHIPURAM DISTRICT KANCHIPURAM TAMIL NADU 603202 | CHENGALPATTU | TAMIL NADU | 603202 | Make: WIPRO
Model: wipro (N95001) | L2 | Qualified | |
| 3 | L3₹6.0 L+₹21,000 (3.64%)Qualified Make: AKSH.
Model: AKSH & B22,E27 F 1080 PHASE III RIICO INDUSTRIAL AREA BHIWADI ALWAR RAJASTHAN 301019 | ALWAR | RAJASTHAN | 301019 | Make: AKSH.
Model: AKSH & B22,E27 | L3 | Qualified | |
| 4 | L4₹6.0 L+₹26,250 (4.55%)Qualified Make: OREVA
Model: OREVA 9W PREMIUM G T ROAD DAMTAL KANGRA | Make: OREVA
Model: OREVA 9W PREMIUM | L4 | Qualified | |
| 5 | L5₹6.1 L+₹30,240 (5.24%)Qualified Make: SYSKA
Model: SSK-SRL-9W 7 AKSHAY COMPLEX OFF DHOLE PATIL PUNE ROAD MAHARASHTRA 411001 | PUNE | MAHARASHTRA | 411001 | Make: SYSKA
Model: SSK-SRL-9W | L5 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
5 May 2018, 4:00 pmClosed
LED Lamps- bulb LED Lamps- Bulb ( 10500 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC LED LAMP Power Ratings/LED Lamp Luminous Flux 9Watt/900 lumens 9watt900lumens Colour Temperature (K) 6500 2700
4000
5700
6500 Type of Lamp CAP B22d B22d
E27 Warranty for free replacement (Years) 3 Years 2 Years
3 Years Conformity to Indian Standard IS:16102 part I and Part II latest N/A FUNCTIONAL LAMP Efficacy (Lm/W) >/=100 N/A LED Chip Efficacy (Lm/W) >/=130 N/A Colour Rendering Index(CRI) >/=80 N/A Beam Angle (Degree) >/=120 N/A Power Factor >/=0.9 N/A Total Harmonics (%) =85 N/A LED chip Wattage (Watt) =80 N/A CONSTRUCTIONAL Light Source (as per LM80 orIS16106) LM-80 1/6 LED Make SAMSUNG Light Source (as per LM80/IS16106) SMD LED Chip Lamp Shell material Polycarbonate Ingress Protection in IP >/=20 TEST REPORT AND CERTIFICATIONS LED life Certificate for 25000 hrs as per LM80 Yes N/A LED life test Certificate No. RSZ150126508-10 N/A LED life Certificate Test Report Date 27.10.2015 N/A LED lamp life certificate for 6000 hrs Yes N/A LED Lamp certificate Number L02201740007 N/A LED Lamp Life Certificate date 09.10.2017 N/A Name of Lab where test conducted Conformity Testing Labs Pvt. Ltd. N/A EMC Test Yes N/A Availability of test Report to IS:16102 Part I and IS:16102 Part II latest Yes N/A Test certificate No. Registration/CRS 2015-3147/R-41029106 N/A Test Report Date 29-11-2016 N/A Name of lab where test conducted Manak Bhavan
9 Bahadurshah Zafar Marg
New Delhi -110002 N/A Complusory Registration(CRS) of BIS for safety as per IS 16102-I Yes N/A * Bold specifications are the golden parameters. 2/6 Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sanjay Manohar Marudkar 400051
Office of the Chief Engineer
Central Purchase Agency
MSPGCL
Prakashgad A K Marg
Bandra-East
600 15 2 Sandesh Prataprao Kamte 400702
O/o THE CHIEF ENGINEER
GAS TURBINE POWER STATION
MAHAGENCO
BOKADVIRA
NAVI MUMBAI 225 15 3 Ambarish Dinanath Pundlik 425307
O/o.Chief Engineer
Maharashtra State Power Generation Company Limited
Bhusawal Thermal Power Stations
Deepnagar
Bhusawal 1125 15 4 Anil Satwajirao Lone 431520
O/o. Chief Engineer
Parli Thermal Power Station
Beed
975 15 5 Rajesh Dhoke 442404
Chandrapur super Thermal Power Station
Chandrapur 2400 15 6 Kamalanand Tukaram Tiple 441111
KTPS
Koradi Dist. Nagpur-441111 1575 15 7 Mayur Gupta 444109
OFFICE OF THE CHIEF ENGINEER O&M
THERMAL POWER STATION
PARASDEEP
Vidyut Nagar
Paras Dist. Akola Maharashtra- 444 109 525 15 8 Sunil Madhavrao Wate 441102
TPS Khaperkheda. 1200 15 9 Nitin Madhukar Pagare 422105
Nashik Thermal Power Station
Eklahare
Nashik Road 1050 15 10 Prafullakumar Jagannath Jadhav 415601
At Post Pophali
Taluka - Chiplun 825 15 EMD 3/6 Required No ePBG Required No
20577
GEM/2018/B/2924
LED Lamps- bulb
15 days
Maharashtra; Mumbai Suburban, Maharashtra; Raigad, Maharashtra; Jalgaon, Maharashtra; Beed, Maharashtra; Chandrapur, Maharashtra; Nagpur, Maharashtra; Akola, Maharashtra; Nashik, Maharashtra; Ratnagiri
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| LED Lamps- bulb LED Lamps- Bulb ( 10500 ) Technical Specifications Specification Specification Name Values Allowed Values GENERIC LED LAMP Power Ratings/LED Lamp Luminous Flux 9Watt/900 lumens 9watt900lumens Colour Temperature (K) 6500 2700 | - | - | - |
| 4000 | - | - | - |
| 5700 | - | - | - |
| 6500 Type of Lamp CAP B22d B22d | - | - | - |
| E27 Warranty for free replacement (Years) 3 Years 2 Years | - | - | - |
| 3 Years Conformity to Indian Standard IS:16102 part I and Part II latest N/A FUNCTIONAL LAMP Efficacy (Lm/W) >/=100 N/A LED Chip Efficacy (Lm/W) >/=130 N/A Colour Rendering Index(CRI) >/=80 N/A Beam Angle (Degree) >/=120 N/A Power Factor >/=0.9 N/A Total Harmonics (%) =85 N/A LED chip Wattage (Watt) =80 N/A CONSTRUCTIONAL Light Source (as per LM80 orIS16106) LM-80 1/6 LED Make SAMSUNG Light Source (as per LM80/IS16106) SMD LED Chip Lamp Shell material Polycarbonate Ingress Protection in IP >/=20 TEST REPORT AND CERTIFICATIONS LED life Certificate for 25000 hrs as per LM80 Yes N/A LED life test Certificate No. RSZ150126508-10 N/A LED life Certificate Test Report Date 27.10.2015 N/A LED lamp life certificate for 6000 hrs Yes N/A LED Lamp certificate Number L02201740007 N/A LED Lamp Life Certificate date 09.10.2017 N/A Name of Lab where test conducted Conformity Testing Labs Pvt. Ltd. N/A EMC Test Yes N/A Availability of test Report to IS:16102 Part I and IS:16102 Part II latest Yes N/A Test certificate No. Registration/CRS 2015-3147/R-41029106 N/A Test Report Date 29-11-2016 N/A Name of lab where test conducted Manak Bhavan | - | - | - |
| 9 Bahadurshah Zafar Marg | - | - | - |
| New Delhi -110002 N/A Complusory Registration(CRS) of BIS for safety as per IS 16102-I Yes N/A * Bold specifications are the golden parameters. 2/6 Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sanjay Manohar Marudkar 400051 | - | - | - |
| Office of the Chief Engineer | - | - | - |
| Central Purchase Agency | - | - | - |
| MSPGCL | - | - | - |
| Prakashgad A K Marg | - | - | - |
| Bandra-East | - | - | - |
| 600 15 2 Sandesh Prataprao Kamte 400702 | - | - | - |
| O/o THE CHIEF ENGINEER | - | - | - |
| GAS TURBINE POWER STATION | - | - | - |
| MAHAGENCO | - | - | - |
| BOKADVIRA | - | - | - |
| NAVI MUMBAI 225 15 3 Ambarish Dinanath Pundlik 425307 | - | - | - |
| O/o.Chief Engineer | - | - | - |
| Maharashtra State Power Generation Company Limited | - | - | - |
| Bhusawal Thermal Power Stations | - | - | - |
| Deepnagar | - | - | - |
| Bhusawal 1125 15 4 Anil Satwajirao Lone 431520 | - | - | - |
| O/o. Chief Engineer | - | - | - |
| Parli Thermal Power Station | - | - | - |
| Beed | - | - | - |
| 975 15 5 Rajesh Dhoke 442404 | - | - | - |
| Chandrapur super Thermal Power Station | - | - | - |
| Chandrapur 2400 15 6 Kamalanand Tukaram Tiple 441111 | - | - | - |
| KTPS | - | - | - |
| Koradi Dist. Nagpur-441111 1575 15 7 Mayur Gupta 444109 | - | - | - |
| OFFICE OF THE CHIEF ENGINEER O&M | - | - | - |
| THERMAL POWER STATION | - | - | - |
| PARASDEEP | - | - | - |
| Vidyut Nagar | - | - | - |
| Paras Dist. Akola Maharashtra- 444 109 525 15 8 Sunil Madhavrao Wate 441102 | - | - | - |
| TPS Khaperkheda. 1200 15 9 Nitin Madhukar Pagare 422105 | - | - | - |
| Nashik Thermal Power Station | - | - | - |
| Eklahare | - | - | - |
| Nashik Road 1050 15 10 Prafullakumar Jagannath Jadhav 415601 | - | - | - |
| At Post Pophali | - | - | - |
| Taluka - Chiplun 825 15 EMD 3/6 Required No ePBG Required No | - | - | - |
Exempted
22 May 2018
21 Apr 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_20577.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .