Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹7.7 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹8.9 L+₹1.1 L (14.5%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹9.3 L+₹1.6 L (20.3%)Admitted-Finance SARCH GANDERBAL J K 191131 | GANDERBAL | JAMMU AND KASHMIR | 191131 | L3 | Admitted-Finance |
Tender Value
₹9.8 L
EMD Value
₹19,700
Closing Date
7 Feb 2026, 4:00 pmClosed
Ex. Engineer RnB Electric Hospital Division Kmr
Office of the Executive Engineer RnB Electric Hospital Division Srinagar
Augmentation / Improvement of damaged / worn out Panels / Switchgears at Govt. Psychiatric Diseases Hospital Srinagar
2026_PWDJK_301815_1
eNIT No. HDE 97 of 2025_26 dated 30_01_2026
Open Tender
Electrical Works
Percentage
20 days
Govt. Psychiatric Diseases Hospital Badamwari Sgr
Please refer Tender documents.
2 documents required · 2 mandatory
₹700
Ex. Engineer RnB Electric Hospital Division Kmr
₹19,700
Ex. Engineer RnB Electric Hospital Div Srinagar
10 Feb 2026
30 Jan 2026
9 Feb 2026
30 Jan 2026
7 Feb 2026
30 Jan 2026
2 Feb 2026
Supply, installation, testing and commissioning of 300 sq. mm, 3.5 Core, 1100 Volt, XLPE insulated, Armoured Aluminium conductor Cable including Supply / Laying of HDPE Pipe (ISI marked) along with all accessories like sockets, bends, couplers, clamps etc. (as per site requirement) conforming to relevant IS, Part II complete with fitting and cutting. The cable shall include end termination lugs including its crimping / taping etc.
Supplying and Installing of 600 mm width X 75 mm depth X 2 mm thickness perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.l. suspenders including G.l. bolts & nuts, etc. as required. The job further includes cost of tray cover & Shall be approved by site Engineer
Supply ,fabrication ,Welding ,Jointing and fixing of GI Angle Iron , V cross ;channels & nuts and bolts of approved sizes (as per site requirement) ,including D-Fastners to be fitted as per site requirement.
ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value. Supply, Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2 No. Bags also having Earth pit chamber (300mm x 300mm) with Man-hole cover for the above, including cost of 20mm wide copper strip as required in one run fitted with brass nut/bolt & spring washer from EARTHING ROD up to the points as specified by the site Engineer through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job.
Dismantling of existing damaged HT-Metering units,Panels,Transformer and other items including cleaning of bushes etc and handing over the same to conerned authorities.
Supply and Installation of CPRI approved, hinged, double door on back and rear sides, lockable, outdoor-type kiosk (Canopy) fabricated out of 14/16 SWG MS Sheets powder coated weather proof, dust proof, with IP 65 protection, with sufficient provision for heat dissipation, suitable to house 250 KVA AVR (servo stabilizer) of standard make. The Drawing of Canopy (showing clearly all dimensions / parameters of Canopy with spacing as per IE Standards) is to approved by Engineer Incharge before Manufacturing / Fabrication.
General Servicing of Existing AVR of 250 KVA by way of replacing damaged coil, bars, digital cards (if any), contactors / relays with oil topping as per site requirement, making AVR functional with balanced output voltage 230V in all respects & to be carried out in presence of site Engineer.
Design, Supply, Installation, Testing and commissioning of CPRI approved Distribution / Feeder Outdoor panel having a sloped roof of cubical type vermin proper double door lockable outdoor type fabricated out of 14/16 SWG MS Sheets powder coated weather proof, dust proof with IP 65 protection with angle iron stand of 2.5 feet height (or as per site requirement) / ground clearance properly grouted in cement concrete of 1:2:4 ratio fitted with glands / thimbles suitable for use at 415 Volts 3 Phase, 4 wire 50Hz system complete in all respects with following components: Incoming: a) 250 Amp-4 pole, 50kA C-CURVE MCCB with extended terminals (Adjustable Thermal & Fixed Magnetic): 1 Nos. b) 600 Amp, TPN, Aluminium Busbar: 1 Set Outgoing: a) 160 Amp, 4 pole, 36 kA, C-CURVE MCCB with extended terminals (Adjustable Thermal & Fixed Magnetic): 3 Nos with digital Voltmer & Indicator set (For 3 Buildings) The Panel manufacturing unit should be CPRI Registered and Drawing of panel (complete in all respects alongwith specifications as per IE Standards) is to be approved by Executive Engineer before manufacturing (Site: Near office of Medical Superintendent). The Job further includes dismantling of existing wall mounted panels & handing over to intending department.
Repairing / Restoration of existing Bus Bar Panel by way of new wiring, replacing suitable thimbles, Painting, Nuts & Bolts, supply and fixing of adjustable MCCBs, MCBs and / or TPN switches. The job further includes supply and fixing of 1 No. 160 Amp TPN MCCB with breaking capacity of 36 KA (Adjustable Thermal & Fixed Magnetic) with extended thimbles making Panel functional in all respects at PG Girls Hostel.
Supply, Installation, Testing and commissioning of 3-Phase, 4-Pole, 160 Amp MCCB, 36kA with extended terminals (Adjustable Thermal & Fixed Magnetic) for existing panel.
Supply of 16-185 Sq. mm aluminium Thimbles/lugs
Providing and fixing of 11KV pin Insulators (5KN) with GI pins conforming to IS : 731 (1971) standards with latest amendents thereof
Providing & Fixing of IK09/IK10, IP 66 protected High Power LED Flood Light, 110-120 Watt, LED Street Light Luminaire on existing pole or wall (including brackets wherever required). Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability / authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre-approved by Executive Engineer.
Straightening of existing 11 Mtr. ST Pole including cement bottoming as per the instructions of Site Engineer.
Providing, installation, testing and commissioning of 4-Pole, Onload, 630 Amp Change-over Switch alongwith Enclosure to be fixed on and including M.S. Angle Iron Structure / legs duly grouted in cement concrete including concreting (complete job)
Supply, installation, testing and commissioning of Guy wire for existing 11 mts ST pole to be grouted in cement concrete and fixed with the Pole as per the instructions of the site engineer.
Supplying and fixing 240/415 V, 10 kA, "C" curve, miniature circuit breakers suitable for inductive load of following Rating / Poles in the existing MCB DBs complete with connections, testing and commissioning etc. as required.
63A, TPN MCB
5A to 32A, SP
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
125 A, 36-40 kA, FPMCCB
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.21 MB
BOQ_979302.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .