| 1 | L1₹16.8 LAccepted-AOC 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹23.7 L+₹5.7 L (31.5%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹23.7 L+₹5.7 L (31.8%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L3 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹47,960
Closing Date
14 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Mathura
HQ CWE Mathura
As per tender documents
2021_MES_460237_1
CA No CWE/MTR/E/23 of 2021-22
Open Tender
Civil Works
Works
180 days
HQ CWE Mathura
Class E cat b(ii)
7 documents required · 7 mandatory
₹500
GE (East) Mathura
₹47,960
Yes
3 Sept 2021
16 Jul 2021
16 Aug 2021
16 Jul 2021
14 Aug 2021
31 Jul 2021
60 days
Amount
Disconnecting electrical connections of step down transformers 11KV/0.433 KV after taking proper electric shutdown and labour and T&P for opening / stripping of the same, draining out oil in clean barrels, lifting the core & coil assembly, washing and cleaning dust, dirt & sludge deposit from all parts, cleaning and polishing of tapping contact point, making internal connections, providing new cork sheet gasket packing 10 mm thick and pouring in the insulating oil in the transformer, re-assembling the transformer after repair work, checking for any leakages including replacement of any unserviceable parts required to make it serviceable all as directed and placing the transformer at original or any other location and making all electric connections including testing the transformer to the entire satisfaction of Engr-in-Charge of following capacities. Note: (i) Spares required for replacement of unserviceable parts shall be measured and paid separately under relevant item of this BOQ as supply only and cost of labour thereof is deemed to be included in unit rate quoted. (ii) Cost of transportation, loading, unloading from sub station to workshop & back including its installation, testing & commissioning complete is deemed to be included in unit rate quoted.
50 KVA to 100 KVA.
150 KVA to 250 KVA.
300 KVA to 400 KVA.
500 KVA to 630 KVA.
Supply only LV brass stud full threaded with required nuts & washer suitable for 11KV/433V distribution transformer of following capacites:
50 KVA to 100 KVA.
150 KVA to 250 KVA.
300 KVA to 400 KVA.
500 KVA to 630 KVA.
Supply only HV brass stud full threaded with required nuts & washer suitable for 11KV/433V distribution transformer of following capacites:
50 KVA to 100 KVA.
150 KVA to 250 KVA.
300 KVA to 400 KVA.
500 KVA to 630 KVA
Supply only LV bushing with gasket suitable for 11KV/433V distribution transformer of following capacites:-
50 KVA to 100 KVA.
150 KVA to 250 KVA.
300 KVA to 400 KVA.
500 KVA to 630 KVA.
Supply only HV bushing with gasket and arcing horn suitable for 11KV/433V distribution transformer of following capacites:-
50 KVA to 100 KVA.
150 KVA to 250 KVA.
300 KVA to 400 KVA.
500 KVA to 630 KVA.
Supply only 433 Volts LV coil with super enamelled copper wire winding of existing type size, gauge and in weight complete including necessary insulating materials and baking the coil in vacuum furnace for transformer 50 KVA to 400 KVA capacity transformers complete all as directed by Engr in Charge.
Supply only 11 KV HV coil with super enamelled copper wire winding of existing type size, gauge and in weight complete including necessary insulating materials and baking the coil in vacuum furnace for 50 KVA to 400 KVA capacity transformers complete all as directed by Engr in Charge
Supply only new transformer oil, clear, transparent and free from all type of suspended matter or sediment, ISI marked as per IS:335/93 with amdt. No.1 (Reaffirmed: 2005) dehydrated to give BDV value not less than 60 KV when tested with 2.5 mm gap electrode for topping up complete all as directed. Make :- Savita / Powerlink / Power oil as approved.
Supply and fixing in repair transformer breather assembly oil seal type made of transparant PVC body heavy duty filled with good quality silica gel blue colour of capacity 800 grams complete all as specified and directed by Engr in Charge
Supply and fixing in repair transformer breather assembly oil seal type made of transparant PVC body heavy duty filled with good quality silica gel blue colour of capacity 1200 grams complete all as specified and directed by Engr in Charge
Material and labour for filtration / dehydration of insulating oil of transformer in position to achieve dielectric strength 50 KV or above (when tested with 2.5 mm gap electrode) complete all as directed by Engr in Charge
Preparation of old painted external surface of transformer by removing/ scraping the rust, washing including cleaning & spray painting with two coats of synthetic enamel grey paint over a coat of primer complete for the following capacities:-
50 KVA to 100 KVA.
150 KVA to 250 KVA.
315 KVA to 400 KVA.
Replacement of old unserviceable/ damaged temperature gauge with new temperature gauge suitable for transformer of any capacity and any type including all necessary accessories i.e. nipple, socket, complete all as specified and as directed by Engineer-In-Charge.
Supply and fixing cable tray suitable for supporting and carrying out LT cable upto transformer of size upto 240 sqmm complete all as directed by Engr in Charge
S&F aluminium lugs for the following sizes complete all as specified and directed by Engr in Charge :-
25 to 50 Sqmm.
50 to 70 Sqmm.
70 to 95 Sqmm.
120 to 150 Sqmm.
185 to 240 Sqmm.
300 to 400 Sqmm.
Heat shrinkable PVC sleeve suitable for XLPE LT UG cable of following sizes complete:-
M&L for earthing complete with galvanized steel earth plate electrode size 600mm x 600mm x 6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to GI earth strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40mm dia connected to main earth wire on pole or control board and GI pipe medium grade 20mm dia bore for watering funnel with wire mesh. RCC cover with concrete (1:2:4) type B-1 using 8mm bars @ 100mm C/C both way with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on completion including taking down existing earthing complete all as specified & directed. Note : The unit rate includes for protection pipe and GI Earth strip 32 x 6mm from top of earth plate upto 7.5m above ground level.
Disconnecting electrical connections of Servo voltage stabilizer by taking out transformer oil and storing for reuse after cleaning and removing moisture, taking all the assembly of voltage stabilizer and removing / repairing the unserviceable parts, reassembling it after repair testing and commissioning the voltage stabilizer of capacity 40 KVA to 50 KVA all as directed by Engr in Charge Note: (i) Spares required for replacement of unserviceable parts shall be measured and paid separately under item No 22 to 27 of scheldule as supply only and cost of labour thereof is deemed to be included in quoted item rate. (ii) Cost of transportation, loading, unloading from site to workshop & back including its installation, testing & commissioning complete is included in the quoted item rate.
All as per srl item No. 18 here-in-above but for servo voltage stabilizer capacity 150 KVA.
All as per srl item No. 18 here-in-above but for servo voltage stabilizer capacity 200 KVA.
All as per srl item No. 18 here-in-above but for servo voltage stabilizer capacity 250 KVA.
Supply only PCB control card for automatic voltage correction suitable for voltage stabilizer of following capacities:
40 KVA to 50 KVA.
Supply only carbon bushes for voltage stabilizer of following capacities:
40 KVA to 50 KVA.
Supply only servo motor for voltage stabilizer of following capacities:
40 KVA to 50 KVA.
Supply only Cast Iron dimmer gear set for automatic voltage correction for servo voltage stabilizer of capacities:
40 KVA to 50 KVA.
Supply only Servo Dimmer Booster coil for automatic voltage correction suitable for servo stabilizer of following capacities:
40 KVA to 50 KVA.
Supply only super enamelled copper conductor winding wire of same guage including necessary insulating materials for servo voltage stabilizer of capacities 40 KVA to 250 KVA.
Taking down old unserviceable control wiring and replacement of control wiring using suitable gauge copper conductor as per existing winding for stabilizer of capacity 15 KVA to 250 KVA complete all as specified and directed by Engr in Charge.
Supply and fixing in replacement digital voltmeter 0 to 500 volts 96x96mm flush type in stabilizers incl taking out the old unserviceable complete.
Supply and fixing in replacement digital ammeter 0-100 square shape 96 mm or as per sample. Make :- AE or equivalent approved make given as per Appendix 'B'.
Supply and laying electrical insulation rubber mating as per ISI and size 1mx2mx25mm thick complete all as directed by Engr in Charge Make :- JAIPURIA Brothers or equivalent make given as per Appendix 'B'.
Excavating in trenches for laying under ground cable, erection of poles and stays in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed by Engr–in–charge.
Excavation in soft /loose soil in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr in depth but not exceeding 3.0 mtr in depth and getting out complete.
Supplying and laying un-reinforced precast concrete cable cover class HV type 1 with peak size 300 mm x 180 mm x 40 mm (ISI Marked) complete all as specified and directed by Engr in Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed by Engr in charge.
Removing surplus excavated material to a distance not exceeding 50m above the starting point complete all as specified and directed by Engr in charge.
M&L for sand cushioning to under ground cable in trenches in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. Note:- Measurement shall be taken after gentling puning of sand.
Supply and laying unreinforced precast concrete cable covers LV type 1, size 250mmx150mmx40mm complete all as directed by Engr in Charge.
Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty LT 1100 volts grade cable with aluminium conductor laid in trenches / pipes, fixed to poles / walls, fixing with suitable saddle/clamps complete all as directed including taking out the old burnt out cables all as directed of following sizes:-
95 Sqmm 3.5 core.
120 Sqmm 3.5 core.
185 Sqmm 3.5 core.
Cutting wild grass, bushes, creeper, unwanted vegetation from inside / surrounding of E/M sub station (transformers) including cutting creepers from barbed / cattle fencing of the sub stn of area not exceeding 300 Sqm as when directed and removing of unwanted material from installation fencing/compound and depositing where directed after taking proper electric shutdown form MRS Mathura. Note :- The item shall be operated maximum two times in entire period of contract in the same installations. (Area measured separately each time).
M&L for providing 100mm PCC platform on top of brick masonry of Size 3x2.5 mtrs (outer dimensions) and 1.2 mtr high from ground level and 0.5 mtr below ground level for placing Transformer, chainlink fencing around the platform fixed to angle iron post 1.8 mtr high using angle iron of size 50mm x 50mm x 6mm and 1.00m away from platform with entry gate and steps and applying a coat of black bituminious paint over a coat of red oxide primer on the steel surfaces complete all as specified and directed including provision as under :- (i) 100mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation of brick wall and fencing post including excavation & earthwork, return filling in. (ii) Brick work with fly ash brick in CM 1:6 including 15mm thick plastering in CM 1:4 over exposed surfaces. (iii) 100mm thick hard core using brick bats of grade n.exc 63mm. (iv) 100mm thick PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in sub base. (v) 100mm thick PCC (1:2:4) type B-2 (using 40mm graded stone aggregate) as in flooring finished even and fair. (vi) Two coats of cement base paint over a coat of cement primer over plastered surfaces complete. (vii) Chain link MS galvanised fencing of mesh size 75mm x 75mm and dia of wire 3mm complete. (viii) Earth filling including watering and ramming in layers of 25cm inside the platform complete. (Earth obtained from excavation shall be used for filling) Note : Rate is inclusive of taking down transformer from foundation/ two pole structure, fixing on suitable trolley, making all electrical connections and restoring power supply and refixing the transformer after civil works all as directed by Engr-in-Charge.
Supply and fixing in replacement drop out fuse assy single pole 11 KV, 25 Amps rating complete with expulsion fuse element mounted on four/two pole structures including necessary nuts, bolts and washers complete all as directed by Engr-in-Charge.
Material and labour for glow sign boards for E/M installtions made up of retroreflective material (blue colour) and writing the letters on sign board in white fixed on stainless sheet of size 1.5 mtr x 1.0 mtr x 3 mm including mounting arrangement with stainless steel pipe of 20 mm for board beadings and 40 mm size for vertical erection of length 2.5 mtrs including all as directed by Engr-in-Charge. Note : Connected civil work like digging for foundations, PCC etc required for vertical erection of sign board will be measured and paid separately in respective item.
Disconnecting and taking down HT UG cable from HT pole/ transformer and cutting faulty end portion of the cable, dressing properly and making good end termination, outdoor type with and including suitable size of heat shrinkable new jointing kit 11000 volts grade and aluminum lugs duly crimped with crimping tool for the following sizes of HT cables:-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm 3 core.
Disconnecting and taking down HT UG cable from HT pole/ transformer and cutting faulty end portion of the cable, dressing properly and making good end termination, Indoor type with and including suitable size of heat shrinkable new jointing kit 11000 volts grade and aluminium lugs duly crimped with crimping tool for the following sizes of HT cables:-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm 3 core.
Supply and jointing HT cable with jointing kit for 11 KV (Earthed) grade cable for straight through heat shrinkable type joint with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cable of following sizes of HT cables:-
95 Sqmm 3 core.
120 Sqmm to 185 Sqmm 3 core.
Dismantling unserviceable cross arms, clamps etc and removing from site all as directed.
Material and labour for cross arms, bracings, supports, clamps, hooks and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminum paint complete all as directed by Engr in Charge.
Supplying, laying, testing and commissioning in repair, XLPE insulated, screened, PVC sheathed galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor ISI marked 11 KV grade (Earthed system) laid in trenches / on pole / in ducts or through sleeves of size 95 Sqmm 3 core complete all as directed by Engr in Charge.
All as per item 50 above but cross sectional area of size 120 Sqmm 3 core complete all as directed by Engr in Charge.
All as per item 50 above but cross sectional area of size 150 Sqmm 3 core complete all as directed by Engr in Charge.
All as per item 50 above but cross sectional area of size 185 Sqmm 3 core complete all as directed by Engr in Charge.
Dismantling steel tubular poles of any size complete all as specified and directed by Engr in Charge.
Supply and erecting steel tubular swaged pole with cast iron base plate, finial taper plug, bolts, nuts & washers as per IS 2713 (Part-II) 1980 made out of mild steel tubing, type 410 SP-55 (11 metre long) including marking pole No on pole including painting of poles with one coat of red oxide primer and two coat of aluminum paint (one coat before fixing and one coat of aluminum paint after fixing) over exposed surface and two coats of bituminous paint over embedded portion & the portion above coping shall be painted in alternative bands of black and yellow colour starting with white colour (each band of 30cm wide) by two coats of super enameled paint upto 1.5m height complete all as specified and directed by Engr in Charge. Note : Earth work and PCC shall be measured separately.
M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed by Engr in Charge.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in foundation complete all as specified and directed by Engr in Charge.
M&L for PCC 1:2:4 type B1 using 20mm graded stone aggregate as in coping complete all as specified and directed by Engr in Charge.
M&L for painting of steel tubular HT pole 11 mtr including cross arms, clamps, back plates etc in situ with one under coat and one finishing coat of aluminum paint after cleaning/ preparation of surfaces including making yellow and black strips 30 cm wide 5 Nos with two coats of synthetic enamel paint all as directed by Engr-In-Charge.
All as per item No 59 here in before but for 2 pole structure including bracings.
All as per item No 59 here in before but for 4 pole structure including bracings.
Material and labour for fixing air break gang operated switch outdoor type HT 11 KV triple pole mechanically operated mounted on HT insulators horizontal/ vertical type as existing at site including MS galvanised steel frame with operating mechanism worked from ground level including operating rod of size 32 mm dia GI medium grade for current rating of cap 200 Amps 11000 volts with locking arrangement, MS clamps, bolts, nuts and washers etc including two coats of aluminum paint over a coat of red oxide primer on MS work complete all as directed by Engr in Charge.
Karman Infra Projects
Vijay Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .