Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC | ₹22.2 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹31.0 LRejected-Finance 225 NAROT COLONY MODEL TOWN PATHANKOT PB 145001 | PATHANKOT | PUNJAB | 145001 | ₹31.0 L | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹32.8 LRejected-Finance | ₹32.8 L | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹34.3 LRejected-Finance | ₹34.3 L | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹34.6 LRejected-Finance | ₹34.6 L | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | pardeep singh marwaha L1 | Vijay Kumar Contractor and Engineers L7 | M/s bhuri and sons L3 | KALSI CONSTRUCTION CO L9 | Surya & Gautam Builders L4 | M/S BR ENTERPRISES L5 | Ashoka Engineers L8 | ANIL ENTERPRISES L6 | M/S SHRI RAM BUILDERS L2 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down the Carefully unserviceable any type security lights /Hanger light/wall lights of any capaciy/size from pole/ bldgs/ walls light and refixing after repair unserviceable items such as choke/lamps/ignitors/ Surge protection, drivers complete all, as specified and directed by Engineer in Charge. (Note:- (i) After completion of contract, contractor shall hand over all the security/perimeter lights conventional type" in perfect running/functioning condition to the department.
(ii) Contractor shall provide his authorised Cell/mobile No. and local address to contact and communicate the message for any break down and contractor's rep will visit the office twice a day (0930 Hrs and 1430 Hrs) to collect the day to day complaints of any nature/type.
(iii) Penalty for not rectifying the defect in time(within 72 hrs)will be charged to contractor and the amount of penalty @ Rs 500/- per complaint will deducted from the due payment of contract.
(iv) Complaints will be treated as rectified only after user's "Satisfactory slip "will be produced by contractor to concerned JE E/M.
(iv) Cost of attending day by day complaint is included in the rate quoted under this item, no extra payment for attending complaint shall be made.
(v) Old material obtained from spares replaced under this item shall be contractor's property and will be measured as per credit schedule.
(vi) Cost of minor spares i.e, wirnig inside light fittng, connecting wire upto terminal box, nut bolts washers or accessories as required for fixing light on pole, connector blocks are deemed to be included in the item rate, items other than mentioned will be measured and paid seperately under respective item of work,
(vii) Cost of T&P i.e, ladders, tools, brazing, welding, soldering required and transportation is deemed to be included in quoted rates
(viii) Area cleaning if required within vicininty of lighing poles is to be done by contractor only and rate for area cleaning is deemed to be included in quoted rates . (ix) Contractor will be take proper shutdown before repaire with communation of IPSS team / Security section for repair of perimeter lights.
Note:-(Items 2 to 13 supply only and fixing against Item 1 ) | 270 | Each Day Job | 217 ₹58,590 | 700 ₹1.9 L | 449 ₹1.2 L | 500 ₹1.4 L | 696 ₹1.9 L | 755 ₹2.0 L | 600 ₹1.6 L | 200 ₹54,000 | 100 ₹27,000 |
| 2.00 | Supply for repair/replacement of LED outdoor driver for 45/60 W LED light complete all as specified and directed by Engineer-in-Charge. | 50 | Each | 139 ₹6,950 | 150 ₹7,500 | 179 ₹8,950 | 300 ₹15,000 | 125 ₹6,250 | 205 ₹10,250 | 100 ₹5,000 | 200 ₹10,000 | 200 ₹10,000 |
| 3.00 | Supply for repair/replacement of LED outdoor driver for 70 to 75 W LED light complete all as specified and directed by Engineer-in-Charge. | 500 | Each | 123 ₹61,500 | 150 ₹75,000 | 179 ₹89,500 | 400 ₹2 L | 135 ₹67,500 | 205 ₹1.0 L | 250 ₹1.3 L | 250 ₹1.3 L | 200 ₹1 L |
| 4.00 | Supply for repair/replacement of driver for 90 W LED flood/ street light complete all as specified and directed by Engineer-in-Charge. | 150 | Each | 131 ₹19,650 | 150 ₹22,500 | 179 ₹26,850 | 425 ₹63,750 | 140 ₹21,000 | 205 ₹30,750 | 250 ₹37,500 | 250 ₹37,500 | 350 ₹52,500 |
| 5.00 | Supply for repair/replacement of LED outdoor driver for 120 to150 W LED flood light complete all as specified and directed by Engineer-in-Charge. | 160 | Each | 169 ₹27,040 | 150 ₹24,000 | 179 ₹28,640 | 460 ₹73,600 | 140 ₹22,400 | 205 ₹32,800 | 250 ₹40,000 | 400 ₹64,000 | 350 ₹56,000 |
| 6.00 | Supply for repair/replacement of voltage surge protection device for LED lights of wattage upto 75 W complete all as specified and directed by Engineer-in-Charge. | 160 | Each | 33 ₹5,280 | 150 ₹24,000 | 89 ₹14,240 | 100 ₹16,000 | 105 ₹16,800 | 205 ₹32,800 | 60 ₹9,600 | 100 ₹16,000 | 150 ₹24,000 |
| 7.00 | Supply for repair/replacement of voltage surge protection device for LED lights of wattage 75W to 150 W complete all as specified and directed by Engineer-in-Charge. | 80 | Each | 33 ₹2,640 | 150 ₹12,000 | 89 ₹7,120 | 120 ₹9,600 | 96 ₹7,680 | 205 ₹16,400 | 60 ₹4,800 | 200 ₹16,000 | 150 ₹12,000 |
| 8.00 | Supply for repair/replacement of street lights cable PVC insulated flexible copper conductor cable of size 2.5 Sqmm three core cut to pieces all as required, drawn into existing conduit/GI pipe of wall or pole complete all as specified and directed by Engineer-in-Charge. | 800 | RM | 6 ₹4,800 | 30 ₹24,000 | 28 ₹22,400 | 40 ₹32,000 | 10 ₹8,000 | 25 ₹20,000 | 10 ₹8,000 | 80 ₹64,000 | 40 ₹32,000 |
| 9.00 | Supply for repair/replacement of multifunctional digital Astro Rex3 D-21 including connecting electrically using copper conductor cable of appropriate size complete all as specified and directed by Engineer-in-Charge. | 8 | Each | 1,666 ₹13,328 | 5,000 ₹40,000 | 1,989 ₹15,912 | 4,500 ₹36,000 | 2,796 ₹22,368 | 1,555 ₹12,440 | 1,900 ₹15,200 | 2,000 ₹16,000 | 2,500 ₹20,000 |
| 10.00 | Supply for repair/replacement of air break contactor 3 pole 415 volts 50 Hz AC-3 duty, current rating 50 amps (normal life) with operating coil voltage 230 volts complete all as specified and directed by Engineer-in-Charge. | 5 | Each | 1,111 ₹5,555 | 2,500 ₹12,500 | 1,989 ₹9,945 | 5,000 ₹25,000 | 2,096 ₹10,480 | 2,055 ₹10,275 | 1,800 ₹9,000 | 3,000 ₹15,000 | 2,500 ₹12,500 |
Updated dates
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
29 Nov 2025, 6:00 pmClosed
Sh Mahajan Singh
GE (AF) Pathankot
REPAIR MAINT OF PERIMETER HANGER SECURITY LIGHTS AND OTHER MISC WORKS IN WSA AND TECHNICAL AREA AT AIR FORCE STATION PATHANKOT
2025_MES_738129_1
GE/PAF-70/2025-26
Open Tender
Civil Works
180 days
GE (AF) Pathankot
As per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Pathankot
₹94,000
Yes
10 Feb 2026
1 Nov 2025
1 Dec 2025
1 Nov 2025
29 Nov 2025
15 Nov 2025
Supply for repair/replacement of LED outdoor driver for 70 to 75 W LED light complete all as specified and directed by Engineer-in-Charge.
Supply for repair/replacement of driver for 90 W LED flood/ street light complete all as specified and directed by Engineer-in-Charge.
Supply for repair/replacement of LED outdoor driver for 120 to150 W LED flood light complete all as specified and directed by Engineer-in-Charge.
Supply for repair/replacement of voltage surge protection device for LED lights of wattage upto 75 W complete all as specified and directed by Engineer-in-Charge.
Supply for repair/replacement of street lights cable PVC insulated flexible copper conductor cable of size 2.5 Sqmm three core cut to pieces all as required, drawn into existing conduit/GI pipe of wall or pole complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement of 2 runs of 1.5 Sqmm PVC insulated stranded copper cable including PVC cassing/capping, ceiling rose, switches mounted on PVC boxes and PVC conduit 20 mm external dia medium grade saddling on building with proper clamping all fidxing arrangements complete all as specified and directed by Engineer-in-Charge.
Each Job
Painting of street light PCC pole without removing accessories with one coat of alternative white and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint .Colour washing the pole above 1.5 mtr height using snowcem of approved colour including painting the steel parts i.e clamps GI bkt etc by applying one coat of alumn paint all as required at site complete all as specified and directed by Engineer-in-Charge.
Writing No of pole with letters/ figures of size not exc 30 mm with black paint on a yellow circle of dia 75 mm complete all as specified and directed by Engineer-in-Charge.
Scraping of old paint from the street light steel tubular pole with out removing accessories and preparation of surfaces for repainting . Repainting the pole with one coat of alternative white and black straps of 30 cm each upto 1.5 mtr height using synthetic enamell paint .Repainting the remaining pole and clamps GI bkt etc above 1.5 mtr height by applying one coat of aluminum paint all as required at site complete all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC medium grade 20 mm conduit including complete fitting and fixture i.e. bend , elbow, suitable for fixing arrangement complete all as specified and directed by Engineer-in-Charge.
Supply and fixing Steel 20 mm conduit including complete fitting and fixture i.e. bend, elbow, suitable for fixing arrangement complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in any type of soil not exc 1.5 Mtr in width and not exc 1.5Mtr in depth and getting out for laying of cable all as required and complete all as specified and directed by Engineer-in-Charge.
Returning filling in, including spreading leveling,watering and well ramming in layers not exc 1.5cm each layer complete all as specified and directed by Engineer-in-Charge.
Removal of surplus soil to distance not exc 50mtr and depositing where directed at level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
Material and labour for sand cushioning to underground cable 8cm thick before laying the cable and 15 cm thick after laying, stretching and testing the cable complete all as specified and directed by Engineer-in-Charge.
Reuse old Sub Class 'B' brick covering protection to the eletric cable laid dry flat transversally along the length of cable on sand cushioning with width equal to length of brick complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable LT cable any size up to185sqmm 2/3.5/4 core retrieved complete all as specified and directed by Engineer-in-Charge.
Relaying only LT cable taking out aganist item passing through pipe 1100 volts grade heavey duty cable with PVC insulated multistand alumn conductor of size 6 to 185 Sqmm 2/3.5 core , armoured with galvanized steel strip or wire all as required and complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 25 sq mm, 2 core including cable lugs, jointing materials GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 16 sq mm, 2 core including cable lugs, jointing materials GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 10 sq mm, 2 core including cable lugs, jointing materials etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 6 sq mm, 2 core including cable lugs, jointing materials GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 50 sq mm, 3.5 core including cable lugs, jointing materials GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 70 sq mm, 3.5 core including cable lugs, jointing materials ,GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 120 sq mm, 3.5 core including cable lugs, jointing materials,GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) with stranded aluminum conductor, 1100 volts grade, of size 185 sq mm, 3.5 core including cable lugs, jointing materials, GI pipeetc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge.
Supply/ Installing testing & commissioning of street Light Pole Box of 63 Amp single phase Two wire having two no Aluminium Bus Bar including 6 Amp SP MCB.The Box should have auto Door lock facility with magnetic lock having size 260X120X230 mm and fixed to poles/ Wall using MS strip of size 20x3mm and nuts & bolts of required size acomplete all as specified and directed by Engineer-in-Charge.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminiuim multistranded of size 16 Sqmm served with inner sheathing of PVC tape and overall PVC sheathed in service connections with one twin core cable flat or circular including cable lugs, jointing materials ,GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated aluminiuim multistranded of size 10 Sqmm served with inner sheathing of PVC tape and overall PVC sheathed in service connections with one twin core cable flat or circular including cable lugs, jointing materials, GI pipe etc., laid in trenches fixed on poles or laid through GI pipes complete all as specified and directed by Engineer-in-Charge.
Supply and fix in replacement MCB single pole 240 volts any rating from 5 to 30 amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as specified and directed by Engineer-in-Charge.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.44 MB
Tender.pdf
Tender Documents • 0.83 MB
BOQ_826515.xls
BOQ • 4.39 MB
Download all tender documents and submit your bid