| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.0 LAccepted-AOC | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹43.2 L+₹1.3 L (3.00%)Rejected-Finance | L2 | Rejected-Finance 2ND LOWEST | |
| 3 | L3₹43.9 L+₹1.9 L (4.48%)Rejected-Finance | L3 | Rejected-Finance 3RD LOWEST | |
| 4 | Rejected-Technical | - | Rejected-Technical Rejected | |
| 5 | Rejected-Technical | - | Rejected-Technical Rejected |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
10 Oct 2022, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR MAINT TO CHAIN LINK FENCING IN OTM ACCN IN ZONE A AREA INCLUDING REPAIR REPLACEMENT OF HT LT SWITCHGEARS CABLES JOINT KITS POLES CHANNELS AND FIRST LINE MAINT ASSETS OF HV LV GRIDS YARDS AT ZONE A AREA AT GMS UNDER GE I GOS
2022_MES_552948_1
8000/26/22-23/0925/E8
Open Tender
Civil Works
Item Rate
270 days
GOPALPUR-ON-SEA
PLEASE REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER I GOS
₹82,000
Yes
10 Nov 2022
19 Sept 2022
12 Oct 2022
19 Sept 2022
10 Oct 2022
3 Oct 2022
Amount
Dismantling posts or sturts (wood,steel or RCC) any section incl taking out embedded portion and making good disturbed ground etc complete all as specified and directed.
Dismantling fencing wire mesh any type etc complete all as specified and directed.
Excavating in post holes (or similar holes) each n.exc 0.5 cum getting out making good the disturbed surface if required in soft/ loose soil complete all as specified and directed.
M&L for PCC 1:3:6 Type C-2 using 40 mm graded stone aggregate in foundation filling and mass concrete complete all as specified and directed.
M&L for providing Precast cement concrete 1:2:4 type B1 in fencing posts boundary pillars, boulders (for stone walling), etc (of any section indicated) with plain fair faces, including chamfers weatherings, throating etc and setting in cement mortor complete with joints to match including necessary form work complete all as specified and directed.
S&F Angle iron posts and rails,drilled and struts in fencing including cutting tops to shape as directed, driiling holes, notching for wire, etc, flat iron fillets (for secruing wire mesh etc) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165.
S&F mild screw bolts (Machine made) with hexagonal or square head at one ends and to fitted with washers and one hexagonal or square n.exc 15cm long, dia of neck 11 to 15mm complete all as specified and directed.
M&L preparation of new steel surfaces of any description over exc 10cm in width or girth and priming with red oxide zinc chrome and applying two coat of synthetic enamel paint complete all as specified and directed.
M&L preparation of new steel surfaces of any description n exc 10cm in width or girth and priming with red oxide zinc chrome and applying two coat of synthetic enamel paint complete all as specified and directed.
S&F PVC coated chain link of 3.16mm dia mild steel galvanised fencing of mesh size 100 mm x 100 mm as per IS : 2721-2003 weight n exc 4.00 kg per sqm complete all as specified and directed.
S&F mild steel round bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to Fe-410-W (Gde E-250) quality-A or Fe-290 (Gde-E-165) complete all as specified & directed.
Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in hard / dense soil complete all as specified & directed.
Excavating in trenches not exceeding 1.5 meter wide and exceeding 1.5 meter and not exceeding 3meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in hard / dense soil complete all as specified & directed.
Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata
Removing excavated soil to a distance n.exc 50m, depositing where directed at a level n.exc 1.5M above the starting point
Supply/ Lay dry river sand /m -sand in trenches for cable protection complete all as specified & directed. Note : Punned thickness only will be measured & Paid
M & L for graded coarse aggregate (broken stone or boulders) of size 40 mm in sub - station yard for laying complete all as specified & directed.
M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for pole and stay foundation.
M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate including use and waste of form work for pole filling/ any description complete all as specified & directed.
S & F in trench/on wall in repairs GI tubing light grade for road crossing and cable protection of 80 mm bore complete all as specified & directed.
All as per item No 20 above, but 100 mm bore.
Dismantling old and unserviceable pre stressed concrete /Steel poles any type including breaking cement concrete complete, Material and erection of steel tubular swaged pole with cast iron base plate finial tapper plug, bolts nuts and screws and specified type 410-SP-55 ( 11mtr long) in truly vertical position 1.5 m length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30 cm width, black and yellow alternatively and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts complete all as specified & directed. (Note:Excavation and PCC shall be measured and paid seperately )
M & L for Prestressed concrete pole, 11.0 metres long. 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 complete all as specified and directed.
S & F in repairs Galvanaised Iron cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete incl painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces incl taking down / dismantling the old items complete all as specified & directed.
Dismantling old unserviceable stay assy complete, material and labour for new stay assembly complete with 20 mm dia stay rod with accessories shown in electric plate No 01 incl stay clamp, (loop insulator, stay wire, excavation and concrete measured seperately) complete all as specified & directed.
S & F in repairs Disc type porcelain vitreous, brown or white insulator suitable for 11 KV HT working Pressure of size 145 mm height, 255 mm dia , including. one galvanised mild steel spindle, two galvanised iron washer and one GI nut complete all as specified & directed.
S & F in repairs Pin type porcelain vitreous,brown of white insulator suitable for 11KV HT of working pressure of size 150mm height, 150mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut complete all as specified & directed.
S & F in repairs cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm complete all as specified & directed.
S & F in repairs cable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm complete all as specified & directed.
S & F in repairs cable jointing kit for 11KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm complete all as specified & directed.
S & F in repairs cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm complete all as specified & directed.
S & F in repairs cable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm complete all as specified & directed.
S & F in repairs cable jointing kit for 11KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm complete all as specified & directed.
Supply & Lay , testing and commissioning in repairs XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 95 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing in different locations / are complete all as specified & directed.
Supply & Lay , testing and commissioning in repais XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 120 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing in different locations / are complete all as specified & directed.
Repairing / Servicing the Air break isolating switch HT 33 KV/11 KV 200/400 Amps by replacing the defective major spares including provn of minor bolts nuts etc complete all as specified & directed. Note :- Major spare will be measured & paid seperately under relevant item of Sch'A' item No. 37
Supply only Male contact/moving Contact Blade 33 KV/11 Airbreak switch complete all as specified & directed.
All as per item No 37 above, but Female contact/Fix Contact Jaw
All as per item No 37 above, but Rotating contactor pipe 200A/400 A
All as per item No 37 above, but MS jumper carrier
All as per item No 37 above, but Back Connector plate
S & F in repairs lighting arrestor Zinc oxide gap less type , station class suitable for 11 KV / 65 KA complete with all fittings complete all as specified & directed.
M & L preparation of old painted surfaces of HT 33 MRS at GOS consisting of Steel poles / ISMBs, cross arms, GOD pipe,clamps etc., having of any description and applying one coat of aluminium paint manually complete all as specified & directed. Note : (a) This rate inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned in this item. (b) This painting work will be carried out during Holidays only to avoid elect shut down.
M & L for removing vegitation, grass, scrubs and bushes growing in Sub station yard along with fancing by mannually / mechanically and keep the sub station yard neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately.
S & F in repairs insulating rubber mat ISI marked of size 1 m x 2 m x19mm suitable for 11 KV at 33 KV MRS Old Air Field complete all as specified & directed.
Taking down carefully the existing 11KV/433 V distribution transformer of capacity 63 KVA to 315 KVA by disconnecting HT overhead connection/underground cables and earth strips etc. from any substation / locations using suitable capacity of crane or by any other method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully. Reloading the tranformer after repairs and testing of transformer; transportation to site and unloading including placing at given position and re-commissioning complete all as specified & directed. Note : All the T&P required for disonnection, connection, loading and loading including necessary petty items like bolts, nuts etc will be arranged by the contractor and rates for the same deem to be included in the rates quoted.
M & L for repairs toTransformer step down 11KV/0.433 KV any type of capacity 63 KVA to 315 KVA, after dismantling the transformer body carefully, opening the top cover of Transformer for inspection /repair, drain out the transformer oil from the tank complete, taking out the core and winding assy by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housing core, renewal/replacement of u/s rubber bushes and washers , replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, warnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, Painting of complete transformer body from outside and inside by weather proof type using spray gun, Marking of MES/SM Number etc, replacement of conservator tank glass, re-intalling the core and winding inside properly, making the all connection with suitable copper lugs, refilling of dehydrated transformer oil including dehydration, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the LT and HT side of the Transformer and testing complete all as specified & directed. Note :- Winding wire including labour for making of coils and LT/HT bushes will be measured & paid seperately.
All as per item No 47 above but of capacity 11 KV/0.433 KV, 315 KVA to 650 KVA complete all as specified & directed.
All as per item No 47 above but of capacity 11 KV/0.433 KV, 315 KVA to 650 KVA complete all as specified & directed.
Supply and filling of fresh transformer power oil of BDV not less than 50 KV for topping up of reduced level of transformer due to evaporation/ leakage/losses due to dehydration in distribution 11 KV transformer /Distribution transformer 63 to 650 KVA or for replacement complete including removing of old unservicable transformer oil complete all as specified & directed.
M & L for conducting oil filtration by stream line / Vacuum type filter machine to remove the moisture/carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for min for distribution transformer incl routine testing after filtration for any capacity of transformers/CT/PT units complete all as specified & directed. (Note : The contractor shall change the filter assy before starting the filtration of power/ distribution transformer of any capacity in presence of Engr In charge)
Material and labour for replacement of brass terminal rod with nuts,bolts washers & bushings suitable for HT side of the transformer of any make and capacity from 63KVA to 315 KVA complete all as specified & directed.
All as per item No 52 above but LT side.
Material and labour for replacement of brass terminal rod with nuts,bolts washers & bushings suitable for HT side of the transformer of any make and capacity from 315 KVA to 650 KVA complete all as specified & directed.
All as per item 54 above but LT side.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 63 KVA to 315 KVA transformer complete all as specified & directed.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 315 KVA to 650 KVA transformer complete all as specified & directed.
M & L for painting using spray painting the outer surface of the transformer with one coat of weather proof paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc paint free after painting including writing the MES/SM No with white enamelled paint all as directed for capacity of transformer 63 KVA to 650 KVA (Indoor/outdoor type) complete all as specified & directed.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x6mm thick burried directly in ground (earth pit not less than 2.25 m deep below normal ground level, connecting to the Galvanised iron earth lead 32x6mm size, by means of bolts, nuts, check nuts and washers of galvanised iron and 32x6 mm earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of concrete pit in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4kg/Sqm) and frame of angle iron 25x25x3 mm with lugs-02 Nos and with 6 mm dia MS bar handle made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom 1.5 meter long placed on top edge of earth plate common salt and charcoal filling, test point with fixing arrangements, funnel wire mesh and earth work in hard/dence soil returning filling in and removal of surplus soil to a distance not exceeding 50 m, all as per electrical plate No 5 of SSR-2010 Part-I and connecting to earth test point complete all as specified & directed.
M&L for replacement off load tap changer for distribution transformer of any make and capacity from 63-650 KVA complete all as specified & directed.
M&L for super enamelled copper conductor wire of suitable gauge and size as per requirement for rewinding the distribution transformer of any capacity / any make complete all as specified & directed.
Material and labour for replacement of bush type insulator white/brown/green working pressure 433 Volts LT side complete all as specified & directed.
M & L for servicing of 33 KV VCB / 11KV VCB / bus coupler by dismantling cleaning greasing the complete VCB with attached relays bus bar etc insulation testing, setting the contact gap by measuring as required reassembling the VCB and reinstalling back to its original position checking and repairing the current circuit panel wiring, replacement of new spares as required complete including operational testing and commissioning complete all as specified & directed. (Note : New spares will be measured and paid separately under relavent item of this schedule)
M & L for carrying out primary & secondary injection test of 33 KV or 11 KV indoor /outdoor type current transformer (Set of three) of VCB's by using standard injection test method and checking the electrical circuits for fault condition, all relay testing and proper functioning incl submitting the test report complete all as specified and directed. (Note : PIT/SIT for VCB will be carried out in 6 months intervals and each primary & secondary injection test will be measured and paid)
Supply only Closing coil 24/30V DC for VCB 11 KV 400 A 25 KA 250MVA as approved by GE agianst Item Ser No 65 complete all as specified and directed.
All as per item No 65 above, but Tripping coil 24/30V DC
All as per item No 65 above, but Antipumping device 24/30V DC
All as per item No 65 above, but Earth Fault and over current relay as per existing and suitable
All as per item No 65 above, but Digital type power factor indicator meter
All as per item No 65 above, but Digital type Voltmeter / Ammeter 96 x 96 mm size
All as per item No 65 above, but LED type indicator lamp assembly
All as per item No 65 above, but spout incoming side
All as per item No 65 above, but spout outgoing side
All as per item No 65 above, but Epoxy insulators bushings for incoming / out going cables / bus bar suppors as per existng size of VCBs
All as per item No 65 above, but Gear system assy complete with handle for charging / discharging of VCBs
All as per item No 65 above, but Spring charging motor for VCBs
All as per item No 65 above, but Over current protection relay as per existing and suitable
All as per item No 65 above, but Metering and protection current transformer epoxy/resin filled of 11 KV grade of ratio 100-50/5 class = 5P, 10/1 25 VA draw out type with necessary mounting and connected items.
M&L for Painting of two pole stucture consistig of 2 Nos PCC pole 11 M height, 1 no GOS, 1 set support insulators with channels, with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code to the metal structure and cement paint to the PCC structures complete all as specified & directed.
M&L for Painting of two pole stucture consistig of 2 Nos (Metal Strucure) 11 M height, 1 no GOS, 1 set support insulators with channels, with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code to the metal structure and cement paint to the PCC structures complete all as specified & directed.
M&L for Painting of four pole stucture consisting of 4 Nos pole(metal structure) 11 M height, 3 no GOS, 1 set Fuse with channels,1Bus bars 1 No LA etc with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code complete all as specified & directed.
M&L for Painting of four pole stucture consistig of 4 Nos pole(PCC) 11 M height, 3 no GOS, 1 set Fuse with channels,1Bus bars 1 No LA etc with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code complete all as specified & directed.
Supply & fix replacement of silica gel complete all as specified and directed..
Supply & fixing of petroleum jelly complete all as specified and directed..
Supply & Fixing in replacement precast PCC cable route indicator duly marked and painted for HT /LT cable of size 80 x 25 x 7.5 CM with suitable size of base complete all as specified and as directed.
Supplying & laying of precast concrete cable cover, class HV, type 1 peak type size 300mmx180mmx40mm complete all as specified and directed..
S & F in repair horn gap fuse 11 kv 200 Amps horizontal/vertical type for outdoor use including all connected accessorises complete all as specified and as directed
Supply and install HT 11 KV 3 phase 50 cycles out door type air break switch suitable for horiandal/Vertical mounting fixed type complete with 9 insulators operating handle and all clamps,nuts,bolts etc of rating upto 200 Amp complete all as specified & directed.
M&L in repairs danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified & directed.
Supply and fixing of fuse wire tinned copper of different capacity as per ground requirement complete all as specified and directed..
M&L for cable fault locator vehicle mounted to locate fault at any type of location with one fault locate at a time complete all as specified & directed.
M&L for in repairs aluminium conductor steel reinforced complete all as specified and directed to be used as jumpers complete all as specified & directed.
M & L for Cutting and trimming of tree branches 5 mtr all around of any size which is coming over the two/four pole structure of 11 KV line by using required tools and plants incl removing trimmed tree branches complete all as specified & directed. (Note : Each cleaning will be measured and paid separetely)
M&L for PVC board of size 30x30 cm with letter written in stickers dully marked the incoming and outgoing cable feeder with suitable size of letters with fixing complete all as specified and directed. Note: Background of the board should be red and letters should be in white colour.
S & F in repairs incl testing of metering & protection current transformer Oil filled out door type of 33 KV capacity ratio 100-50/5 or 200-100/5 class=5P, 10/1 15 VA including dismantling old existing CT complete all as specified & directed.
Dismantling old and burnt out PT unit 33000/110/220 volts oil filled out door type taking out contact with lead and bushing from the bus bar and replacing by new one of same model suitable for 33 KV PT unit incl testing on complete all as specified & directed.
S & F in repairs cable jointing kit for 33 KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm.
M/s Bapujee Builders and Traders
M/s Er. Shashanka Sekhar Patro
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .