Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC MOH PADAW NAWABGANJ GONDA U P 271303 | GONDA | UTTAR PRADESH | 271303 | ₹13.4 L | L1 | Accepted-AOC ok |
| 2 | L2₹13.4 LRejected-Finance | ₹13.4 L | L2 | Rejected-Finance ok |
Tender Value
₹13.6 L
EMD Value
₹27,200
Closing Date
28 Apr 2026, 12:00 pmClosed
Executive Engineer
EE red saharanpur vikas bhawan delhi road saharanpur
Gram bishanpur mein mangeram rohale ke Makan Se vijay pal ke Makan ki or sadak Nirman karya
2026_REDUP_1139817_9
1617/RED/cashier/25-26 dt 20-03-2026
Open Tender
Civil Works
90 days
EE red saharanpur
Gram bishanpur mein mangeram rohale ke Makan Se vijay pal ke Makan ki or sadak Nirman karya
3 documents required · 3 mandatory
₹766
₹27,200
Yes
EE red saharanpur vikas bhawan delhi road saharanp
2 Jun 2026
23 Apr 2026
28 Apr 2026
23 Apr 2026
28 Apr 2026
23 Apr 2026
25 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m (As per Mord Sr.No.-2.5-II(A) & Technical Specification Clause 202.) | - | Cum. | - | - | BI01010001010000000000000515BI0100001113 |
| 2 | Construction of embankment with approved material obtained from borrow pits with a lift upto 1.5 m, transporting to site, spreading, grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 3000 m as per MORD Technical Specification Clause 3.4 - 301.5 | - | Cum. | - | - | BI01010001010000000000000515BI0100001114 |
| 3 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings (As per Mord Sr.No.-11.4 and technical specifications Clause 802, 803, 1202 & 1203) P.C.C. Grade M-10, Nominal mix (1:3:6). | - | Cum. | - | - | BI01010001010000000000000515BI0100001115 |
| 4 | Brick masonry work in cement mortar in substructure complete excepting pointing and plastering, as per drawing (As per Mord Sr.No.-11.5 and technical specification Clauses 602, 603, 604, 1202 & 1204 (II). (In 1:4 Cement mortar). | - | Cum. | - | - | BI01010001010000000000000515BI0100001116 |
| 5 | Plastering with cement mortar (1:4), 12 mm thick on brickwork in substructure (As per Mord Sr.No.-12.3 and technical specification Clauses 613.4 & 1204. | - | Sqm. | - | - | BI01010001010000000000000515BI0100001117 |
| 6 | Providing concrete for plain/reinforced concrete in open foundations complete as per drawings (As per Mord Sr.No.-11.4 -(III) and technical specifications Clause 802, 803, 1202 & 1203) P.C.C. Grade M-20, Nominal mix (1:2:4). | - | Cum. | - | - | BI01010001010000000000000515BI0100001118 |
| 7 | Construction of Granular Sub Base by providing Well graded material, spreading in uniform layers with Motor grader/Tractor mounted appropriate equipment on prepared surface, mixing by mix in place method with Rotavator at OMC and compacting with Smooth wheel roller to achieve the desired density complete as per Technical Specification Clouse 401 | - | Cum. | - | - | BI01010001010000000000000515BI0100001119 |
| 8 | Providing, laying, spreading and compacting Stone aggregates of specific sizes to Water Bound Macadam (WBM-G-III) specification incl spreading in uniform thickness, hand packing , rolling with three wheel 80-100kN static roller in stage to proper grade and camber , applying and brooming , crushable screening to fill up the interstices of coarse aggregate , watering and compacting tothe required density Grading 3 as per Technical Specification Clause 405. | - | Cum. | - | - | BI01010001010000000000000515BI0100001120 |
| 9 | Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 (As per Mord Sr.No.-12.5 and Technical Specification Clause 800).(Concrete Grade-M-25) | - | Cum. | - | - | BI01010001010000000000000515BI0100001121 |
| 10 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Mild steel and Medium Tensile steel bars (As per DSR Sr.No.- 5.22.1 | - | Qtls. | - | - | BI01010001010000000000000515BI0100001121 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.35 MB
BOQ_2128804.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid