Driller-in-Charge
Office of the Driller-in-Charge. Bankura Mechanical Sub-Division (Drilling). P.H.E. Dte. Ailakundi, PO Kenduadihi, Bankura 722102
Rectification of Transformer, AVR, VCB with related allied works at Pathardoba w/s Scheme under BMD, PHE, Dte.
2025_PHED_855039_1
WBPHED/DIC/BMSD(D)/NIeT-2 OF 2025-2026
Open Tender
Electrical Work/ Equipment
Item Rate
20 days
Bankura
Please refer Tender documents.
5 documents required · 5 mandatory
₹12,000
Yes
23 Jul 2025
5 Jun 2025
24 Nov 2025
5 Jun 2025
16 Jun 2025
5 Jun 2025
Amount
supply delivery of the following switch gear or other items for necessary rectification of the existing sub-station (1 nos AVR, 1 no single panel VCB , 1 no 4 panel VCB, 2 nos transformer ) at site
Single Panel VCB
Supply of 8 Channel Annunciator ( Make : Minilac Model : MBAS : 0600 )
400 KVA HT AVR (7-12/11 KV)
240 sq. mm. X 3 core, 11 KV grade, Indoor type, Heat shrinkable End Termination Kit supply 9Make-Approved)
Painting Charges of AVR B-Unit and (A+C) Unit (Including derusting Paint supply)
Supply of Foam and Cable Entry Point filling by Foam for AVR Pan
315 KVA Transformer (11 KV / 0.433 KV) :
Transparent Breather supply with 1/2 Kg. Silica Gel
Transformer body De-Rusting and Painting (including Paint supply)
95 sq. mm. X 3 core, 11 KV grade, Indoor type, Heat shrinkable End Termination Kit supply (Make-Approved)
Supply of Foam and Cable Entry Point filling by Foam for each Panel
4- PANEL VCB
Charges for 11 KV HT cable disconnection, 11 KV CT primary & secondary side disconnection, 11 KV CT dismantling, rubbing, cleaning done by applying CRC, WD-40. After that heating treatment done, then varnishing done by applying Red Insulation Varnish to improve the IR value, after improving the IR value finally re-fitting the 11 KV CT, reconnecting the primary and secondary connection and termination of 11 KV HT cable and power charging done of Incomer, Outgoing-1, Outgoing-2 & Spare Panel
Charges for CT Spouts & Bus-Bar Spouts Dismantling, Rubbing, Cleaning done by applying CRC, WD-40. After that heating treatment done, then varnishing done by applying Red Insulation Varnish to improve the IR value, after improving the IR value finally re-fitting all spouts of Incomer, Outgoing-1, Outgoing-2 & Spare Panel
Charges for complete Bus-Bars Dismantling, Sulfation Cleaning by applying CRC, WD-40, for IR Improvement and finally Re-fitting.
Painting with paint supply for Incomer, Outgoing-1, Outgoing-2 & Spare VCB Chamber & CT Chamber Painting
Rusted portion De-rusting & Painting charges of Incomer, Outgoing-1, Outgoing-2 & Spare VCB Chamber & CT Chamber
Power Pack supply (Make: Shruti Electronics)I/P: 110 / 230 V AC, O/P: 110 V DC
Solid State Electronic Buzzer / Hooter supply (Make: STS) Model: SBMV-96, Aux: 12 – 240 V AC/DC
2.5 sq. mm 3 core cu wire for control circuit modification (Make-Approved)
Supply of Foam and Cable Entry Point filling by Foam for each Panel
Fault finding and through out checking of the existing complete Sub Station at Gargaria W/S Scheme at Sarenga Block of Bankura District by expart engineer and other technician with carrying different Testing servicing kit/machine like Insulating Resistance checking machine (1KV, 2.5KV, 5KV) 3 phase variac, Current injection machine/kit, Voltage injection machine/kit, Blower , Multimeter, clamp meter , Different type of tools tackles , verious testing wires, MCBs , wires & Cables , HT insulation tapes, Gas can with nozzle, CRTWD-40, Lecta cleaner , Adesive non adesive PVC taaps and itrms for complete servicing and testing the Transfoemers , VCBs, AVR with connecting HT, LT cables.
Fitting fixing of the above said supplied items Sl No 2-5 with expart engineers, electricians with needed HT inssulators, tapes,various cleaner by dismalting the 315 KVA 2 nos transformers all HT LT terminals, opening the top cover, arresting any kind of leakage by changing the gaskets oil seal of top cover , inspection cover tap switches, consevertor tanks, radiators, HT-LT bushing portion, OLTC new UPS , Breaather replacement With suppling of necessary HT-LT insulator tapes , seals , glands , glue, teflon tapes and other items to complete the work with Checking and testing of rectified the 2 nos VCB (1 nos Single panel , 1 no 4 panel ) 2 no 315 KVA transformers, 1 no AVR (Indoor and out door unit with other all the parameters for health fault free operation for a certaion duration as per direction of EIC
Add: 18% GST
Add: 1% Cess
Premnath Mitra (BID ID -6550007)
MS S G Enterprise (BID ID -6549893)
M/S. SWAPAN BANERJEE (BID ID -6549946)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .