Power Grid Corporation of India Limited -Saudamini, 3rd Floor, Plot No 2, Sector-29 Gurugram (Haryana) - 122001.
Package-X: New Generation Equipment Package for MPLS-TP, OTN system & L2 Switch type of equipment under Procurement of Telecom Equipment (DWDM/ SDH), associated Auxiliary System and Fiber Optic Cable System for augmentation of Telecom Backbone and Access Network.
CC-CS/1021-SR2/TELE-4121/3/G5
Open
Electrical - All
Works
PAN INDIA Telecom Network
₹25,000
₹59.5 L
13 Nov 2020
30 Apr 2020
2 Sept 2020
30 Apr 2020
31 Aug 2020
30 Apr 2020
14 May 2020
(Period in weeks from LOA)
Batch-1*
Batch-2*
Batch-3*
Network Security Audit/ Vulnerability assessment
Batch-1 (200 Equipments)
Lot-1 (100 Equipments)
Lot-2 (50 Equipments)
Lot-3 (50 Equipments)
Batch-2 (140 Equipments)
Lot-1 (70 Equipments)
Lot-2 (70 Equipments)
Batch-3 (50 Equipments)
Lot-1 (50 Equipments)
POWERGRID may increase/ decrease the no of Equipment in each LOT based on requirement.
POWERGRID may increase/ decrease the no of BATCH/ LOT for delivery of equipment, based on requirement.
POWERGRID may advance/ delay in the implimentation of TMN
BoQ for 'Package-X: New Generation Equipment Package'
OTN System (100G)
Base Equipment (Crossconnect Fabric, Common cards, min 2x100G line & min 10x10G/ STM-64 client ports, Power supply cards, patch cords, power cabling, tributary cables, other hardware & accessories including sub-racks etc. fully equipped excluding optical Pluggable) Hardware & Software
100G OTN Line pluggable optics (40km)
100G OTN Line pluggable optics (80km)
MPLS-TP Equipment (100G)
Base Equipment (Crossconnect Fabric, Common cards, min 2x100G line & min 10x10G client ports, Power supply cards, patch cords, power cabling, tributary cables, other hardware & accessories including sub-racks etc. fully equipped excluding optical Pluggable) Hardware & Software
100G Line pluggable optics (40km)
100G Line pluggable optics (80km)
Base Equipment (Crossconnect Fabric, Common cards, min 4x10G & min 4x1G (2 Optcial + 2 Electrical) ports patch cords, power cabling, tributary cables, other hardware & accessories including sub-racks etc. fully equipped excluding optical Pluggable) Hardware & Software
Base Equipment (Crossconnect Fabric, Common cards, min 4x10G (optical), 4x1G (2 Optcial + 2 Electrical) ports, 6xE1 & 1xSTM-1 ports, patch cords, power cabling, tributary cables, E1 Cable, STM-1 SFP, other hardware & accessories including sub-racks etc. fully equipped excluding optical Pluggable) Hardware & Software
Base Equipment (Crossconnect Fabric, Common cards, min 4x1G ports (Min 2x1G Optical & min 2x1G Electrical), equipped with SFP, Power supply cards, patch cords, power cabling, tributary cables, other hardware & accessories including sub-racks etc. fully equipped)
AC Power Module
DC Power Module
10GBASE-ZR XFP
10GBASE-ER XFP
10G BASE-LR XFP
10G BASE-SR XFP
1000 BaseLX SFP
Gbe Electrical (1000 base-T) SFP
BI-DI XFP (STM-64/ 10G) 60 KM PAIR:END A
BI-DI XFP (STM-64/ 10G) 60 KM PAIR:END Z
Cabinet Standard
Cabinet Data Center
The ‘Set’ consists of all necessary amplifiers, pluggable Optics for respective equipment, Patch cords, power cables, Communication/ DCN cable accessories and any other items as per TS, for one end of the link i.e. POWERGRID shall order two (02) sets for implementation of one (01) link.
Amplifier Solution Set for 30 dB
Amplifier Solution Set for 35 dB
Amplifier Solution Set for 40 dB
Server
Work stations
Other hardwares
(One set will comprise of all necessary hardwares e.g. gateway NE, Router/Ethernet swtich/Converter etc. as required.)
System software
(One set will comprise of all necessary hardwares e.g. computer system, gateway NE, Router/Ethernet swtich/Converter etc. as required.)
Application software
Server
Work stations
Other hardwares
(One set will comprise of all necessary hardwares e.g. gateway NE, Router/Ethernet swtich/Converter etc. as required.)
System software
Application software
(One set will comprise of all necessary hardwares e.g. computer system, gateway NE, Router/Ethernet swtich/Converter etc. as required.)
Training
Synchronization Clock (Rubidium)
Synchronization Clock (OCXO)
24x7 Shift Operations
Day time Operations (9:00 to 18:00 Hrs)
Comprehensive AMC of all elements in Network
Power Grid Corporation of India Ltd. Telecommunication Backbone and Access Augmentation Project Volume II - Appendcies for Package-X: New Generation Equipment Package
Appendix D
Data Requirement Sheets
The following sets of Data Requirement Sheets are required to be filled up by the bidders to aid in the evaluation process. The response shall be brief and to the point and shall be supported by the printed product description and other literature. However, more parameters may be required to provided in DRS during detailed engineering.
NOTE- DRS for each type of offered equipment shall be filled separately by the bidder & attached with the bid
DATA REQUIREMENTS SHEETS for OTN 100G SYSTEM
Manufacturer:
Model #:
Dimension (mm)
Weight (kg)
Max. Power Supply (W)
Voltage Range (V)
Please mention all modules(Like Xconnect , Controller, FAN ,Power card etc.)
Please mention all modules(Like Xconnect , Controller, FAN ,Power card etc.)
Number of Service Slots
Cross-connect Type
Cross-connect Capability
Rate per Channel (maximum)
Number of Switching Fabric Modules
Switching capacity to each interface card
If more than one Switching Fabric goes done which interface traffic will go down
Supporting other Bit Rates above 100G:
Transport and storage
Operation for long term
Operation for short term
System Availability
Secure Shell (SSHv2) support for remote login and file transfer
SFTP (Secure File Transfer Protocol)
Allows the administrator to define actions permitted for each user
Auto-logout function to logout the idle session
Specify equipped Bit Rates:
Spectral Characteristics(Maximum -20 dB spectral width)
Laser Class
Data rate
Input frequency tolerance
Framing Baud Rate
Modulation format
Pulse shaping
Eye Pattern Mask
Extinction ratio
Channel spacing
Central Frequency Deviation
FEC coding gain
Wavelength range:
Wavelength locking time
Absolute wavelength stability(over life & temperature)
Laser line width (unmodulated)
Side mode suppression ratio
Tx power
output power stability
Chromatic Dispersion tolerance
PMD tolerance
Rx input power range
Receiver reflectance at RS
Pre-FEC BER
BER / error floor (post-FEC) < 1e-15
Bit Rate
Frequency Range
Frequency Spacing
Frequency Stability
Transmission Distance
Connector Type
Transmitter
Laser Type
Mean Output Power(Max)
Mean Output Power(Min)
Minimum Extinction ratio
Eye Mask
SBS Suppression
Optical Path
Dispersion(Max)
Optocal retun Loss(Min)
Discrete reflectance (Max)
DGD(Max)
Receiver
Mean input power Load
Reflectance of receiver
Sensitivity path panelty
Application Code
Fiber type
Modulation
Supported Distance Range [km]
Laser Types
Central Wavelength [nm]
Max. Spectral Width [nm]
Average Launch Power [dBm]
Extinction Ratio [dB]
Receiver Types
Mini. Overload [dBm]
Receiver Sensitivity @BOL [dBm]
Receiver Sensitivity @EOL [dBm]
Optical Path Penalty [dB]
Max. Reflect. of receiver [dB]
Digital Diagnostics Function
ITU-T G.691 Mask Margin
STM-64/ 10GE:
STM-16/Gbe:
SNC/I (sub-network connection with inherent monitoring)
SNC/N (sub-network connection with non-intrusive monitoring)
SNC/S (sub-network connection with sub-layer monitoring)
HO/LO SNC protection
1+1 unidirectional SNC/N, SNC/I and SNC/S w/o APS protocol
1+1 bidirectional SNC/I and SNC/S w/ APS protocol
Unidirectional
Bidirectional (single fibre operation)
Output power Range
Receive Maximum/Minimum power
Laser class
Wavelength range
Gain ripple
EDFA tilt for minimum gain ripple
Noise figure
Gain flatness
Multichannel Gain Variation
Multichannel Gain-change difference
Raman Amplifier safey precations and measure
VOA range
Amplifier management
OPTICAL SUPERVISORY CHANNEL MODULE
OSC transmitter wavelength (nm)
OSC transmitter output (dBm)
OSC receiver sensitivity (dBm)
Insertion loss of return path (dB)
Network Management
Input Port
Output Port
Loss of Signal
Loss of Frame
Signal Degradation(BER)
Input Port
Output Port
a) 100G on G.652 and G.653 fibre
b) 10G on G.652 and G.653 Fiber
Nominal supply voltage:
Power supply variation
Guaranteed performance:
Operation without damage:
Polarity:
Whether 220 Vac mains operation capability inbuilt
List derived DC voltages:
Module cut of power values
Total power consumption (Fully equipped incl. service channels)
Unprotected terminal:
1+1 Protected terminal:
1+1 APS protection provided?
MTBF of power supply unit:
Ultimate power delivery capacity
Are the following protections provided?
Whether proposed equipment has distributed Power Supply?
Provide AC & DC power supply requirement for each of the proposed equipment.
Provide Procedure to convert OLA and Repeaters to Add Drop Multiplexer
Power Distribution in Subrack by power module
Expected life of Equipment
Engineering Orderwire (Fill for all type of Equipment)
Omnibus calling available?Describe:
Signalling scheme Describe:
DTMF supported
Tx/Rx level
Speech coding method & bit rate
Distortion:
Noise performance:
OSC as per G.692
Are Service channel requirements specified in section 2.2.1.3 met?
No of data channels:
Interfaces/Connectors:
Data rates:
PROTECTION SWITCHING
List the type of Protection Schemes supported by the Equipment
Discuss the proposed protection scheme
Switching modes available(For Modules)
Manual?
Remote/network management?
Switching priority:
switchover & switchback criteria:
Switch option mode & status indicators:
Switching Time
Nominal:
Maximum:
List all alarms supported by Equipment:
Number of Sub-Racks (including DC/DC converters, O/W muldem etc.) required for Unprotected Terminal:
1:1 Protected Terminal:
Sub-Rack mounting options:
Sub-Rack clearance requirements
Top * Bottom * Sides:
Front Access:
Rear Access:
Sub-Rack color and finish
Cabinet options available
Slim rack?
Others (specify)?
Whether Truncated Cabinet Available?
Fill for all Cabinet Types Proposed
Protection Class (IP Class):
Rack Color and Finish:
Altitude Installed:
Air flow in subrack (diagram required)
Describe Ventilation requirements:
Describe dustproofing provisions:
Electromagnetic compatibility (List standards & severity levels) (Submit Test Reports)
Noise Standards supported (Submit Test Reports )
Environmental standards supported (Submit Test Reports)
DATA REQUIREMENTS SHEETS for MPLS-TP
Manufacturer:
Model #:
Equipment Type
Dimension (mm)
Weight (kg)
Max. Power Supply (W)
Voltage Range (V)
Please mention all modules(Like Xconnect , Controller, FAN ,Power card etc.)
Please mention all modules(Like Xconnect , Controller, FAN ,Power card etc.)
MPLS Tunnel1:1 Switch Time
LAG Switch Time
Max. Number of Routing
Number of MPLSTunnel
Max. Number of MSP Group
Max. Number LAG Group
Max. Number LSP Protection Group
Max. Number Wrapping
Number PW
Number E-line
Number of E-LAN Service
Number of E-Tree Service
Static MAC Address
Accuracy of CAR/Shaping
Number of CAR
Number of Multicast
Number of PTP Interface
Number of Sync ETH Interface
VLAN (IEEE 802.1Q)
Q-in-Q (IEEE 802.1ad)
9600 bytes jumbo frame
VLAN manipulation: stack/switch/strip
IGMP snooping (V1/V2/V3)
Flow control (IEEE 802.3x)
MPLS-TP OAM (G.8113.1/G.8113.2)
ITU-T Y.1731 End-to-end Performance Monitoring and AIS
802.3 Link OAM
802.1 CFM OAM
LSP 1:1 linear protection
LSP SNC protection
LSP ring protection
Single segment (SS) pseudowire 1:1 protection
Multi-segment (MS) pseudowire 1:1 protection
802.1AX Link Aggregation (UNI/NNI) with LACP
RSTP (IEEE 802.1Q)
Link Pass-Through (LPT)
L2 Classification: VLAN,PRI, MAC address, TPID
L3 Classification: IP address,DSCP, port number, TOS
Connection Admission Control (CAC)
Policing (CIR, CBS, EIR, and EBS; ColorBlind Mode and Color-Aware Mode)
Shaping
Congestion Avoidance: WRED
Transport and storage
Operation for long term
Operation for short term
System Availability
Secure Shell (SSHv2) support for remote login and file transfer
SFTP (Secure File Transfer Protocol)
Allows the administrator to define actions permitted for each user
Auto-logout function to logout the idle session
Specify equipped Bit Rates:
Spectral Characteristics(Maximum -20 dB spectral width)
Laser Class
Data rate
Input frequency tolerance
Framing Baud Rate
Modulation format
Pulse shaping
Eye Pattern Mask
Extinction ratio
Channel spacing
Central Frequency Deviation
FEC coding gain
Wavelength range:
Wavelength locking time
Absolute wavelength stability(over life & temperature)
Laser line width (unmodulated)
Side mode suppression ratio
Tx power
output power stability
Chromatic Dispersion tolerance
PMD tolerance
Rx input power range
Receiver reflectance at RS
Pre-FEC BER
BER / error floor (post-FEC) < 1e-15
Bit Rate
Frequency Range
Frequency Spacing
Frequency Stability
Transmission Distance
Connector Type
Transmitter
Laser Type
Mean Output Power(Max)
Mean Output Power(Min)
Minimum Extinction ratio
Eye Mask
SBS Suppression
Optical Path
Dispersion(Max)
Optocal retun Loss(Min)
Discrete reflectance (Max)
DGD(Max)
Receiver
Mean input power Load
Reflectance of receiver
Sensitivity path panelty
Application Code
Fiber type
Modulation
Supported Distance Range [km]
Laser Types
Central Wavelength [nm]
Max. Spectral Width [nm]
Average Launch Power [dBm]
Extinction Ratio [dB]
Receiver Types
Mini. Overload [dBm]
Receiver Sensitivity @BOL [dBm]
Receiver Sensitivity @EOL [dBm]
Optical Path Penalty [dB]
Max. Reflect. of receiver [dB]
Digital Diagnostics Function
ITU-T G.691 Mask Margin
Bit Rate
Connector Type
Symmetry
Load Impendance
Peak Voltage (Signal Transfer)
Peak Voltage (No Signal)
Return Loss
Input jitter acceptance
Maximum output jitter in the absence of i/p jitter
Jitter transfer characteristic:
Unidirectional
Bidirectional (single fibre operation)
Output power Range
Receive Maximum/Minimum power
Laser class
Wavelength range
Gain ripple
EDFA tilt for minimum gain ripple
Noise figure
Gain flatness
Multichannel Gain Variation
Multichannel Gain-change difference
Raman Amplifier safey precations and measure
VOA range
Amplifier management
OPTICAL SUPERVISORY CHANNEL MODULE
OSC transmitter wavelength (nm)
OSC transmitter output (dBm)
OSC receiver sensitivity (dBm)
Insertion loss of return path (dB)
Network Management
Nominal supply voltage:
Power supply variation
Guaranteed performance:
Operation without damage:
Polarity:
Whether 220 Vac mains operation capability inbuilt
List derived DC voltages:
Module cut of power values
Total power consumption (Fully equipped incl. service channels)
Unprotected terminal:
1+1 Protected terminal:
1+1 APS protection provided?
MTBF of power supply unit:
Ultimate power delivery capacity
Are the following protections provided?
Whether proposed equipment has distributed Power Supply?
Provide AC & DC power supply requirement for each of the proposed equipment.
Provide Procedure to convert OLA and Repeaters to Add Drop Multiplexer
Power Distribution in Subrack by power module
Expected life of Equipment
a) 100G on G.652 and G.653 fibre
b) 10G on G.652 and G.653 Fiber
MEF CE 2.0 Compliant: E-Line, E-LAN,E-Tree, E-Access
ETSI EN 300 386 V1.6.1/EN 55022(2010)
Others
PROTECTION SWITCHING
List the type of Protection Schemes supported by the Equipment
Discuss the proposed protection scheme
Switching modes available(For Modules)
Manual?
Remote/network management?
Switching priority:
switchover & switchback criteria:
Switch option mode & status indicators:
Switching Time
Nominal:
Maximum:
List all alarms supported by Equipment:
Number of Sub-Racks (including DC/DC converters, O/W muldem etc.) required for Unprotected Terminal:
1:1 Protected Terminal:
Sub-Rack mounting options:
Sub-Rack clearance requirements
Top * Bottom * Sides:
Front Access:
Rear Access:
Sub-Rack color and finish
Cabinet options available
Slim rack?
Others (specify)?
Whether Truncated Cabinet Available?
Fill for all Cabinet Types Proposed
Protection Class (IP Class):
Rack Color and Finish:
Altitude Installed:
Air flow in subrack (diagram required)
Describe Ventilation requirements:
Describe dustproofing provisions:
Electromagnetic compatibility (List standards & severity levels) (Submit Test Reports)
Noise Standards supported (Submit Test Reports )
Environmental standards supported (Submit Test Reports)
DATA REQUIREMENTS SHEETS for L2 Switch
Manufacturer:
Model #:
Equipment Type
Dimension (mm)
Weight (kg)
Max. Power Supply (W)
Voltage Range (V)
Ports
Technical Specifications
Switching capacity nonblocking
Forwarding rate
Jambo Frame
Flash Memory
MAC table size
Number of VLANs
Type of VLAN
HOL blocking
Web user interface
CLI interface
SNMP MIBs
Firmware upgrade
Port mirroring
Other management
IEEE 802.1X
Access control
Access security
Link aggregation
Storm control
Spanning tree
IGMP snooping
Priority levels
Scheduling
Class of service
Per flow QoS
Rate limiting
Standards
Application Code
Fiber type
Modulation
Supported Distance Range [km]
Laser Types
Central Wavelength [nm]
Max. Spectral Width [nm]
Average Launch Power [dBm]
Extinction Ratio [dB]
Receiver Types
Mini. Overload [dBm]
Receiver Sensitivity @BOL [dBm]
Receiver Sensitivity @EOL [dBm]
Optical Path Penalty [dB]
Max. Reflect. of receiver [dB]
Digital Diagnostics Function
ITU-T G.691 Mask Margin
Transceiver form factor
Transmission speed
Connector type
Applicable cable and maximum transmission distance
Transport and storage
Operation for long term
Operation for short term
Unidirectional
Bidirectional (single fibre operation)
Nominal supply voltage:
Power supply variation
Guaranteed performance:
Operation without damage:
Polarity:
Whether 220 Vac mains operation capability inbuilt
List derived DC voltages:
Module cut of power values
Total power consumption (Fully equipped incl. service channels)
Unprotected terminal:
1+1 Protected terminal:
1+1 APS protection provided?
MTBF of power supply unit:
Ultimate power delivery capacity
Are the following protections provided?
Whether proposed equipment has distributed Power Supply?
Provide AC & DC power supply requirement for each of the proposed equipment.
Provide Procedure to convert OLA and Repeaters to Add Drop Multiplexer
Power Distribution in Subrack by power module
PROTECTION SWITCHING
List the type of Protection Schemes supported by the Equipment
Discuss the proposed protection scheme
Switching modes available(For Modules)
Manual?
Remote/network management?
Switching priority:
switchover & switchback criteria:
Switch option mode & status indicators:
Switching Time
Nominal:
Maximum:
List all alarms supported by Equipment:
Number of Sub-Racks (including DC/DC converters, O/W muldem etc.) required for Unprotected Terminal:
1:1 Protected Terminal:
Sub-Rack mounting options:
Sub-Rack clearance requirements
Top * Bottom * Sides:
Front Access:
Rear Access:
Sub-Rack color and finish
Cabinet options available
Slim rack?
Others (specify)?
Whether Truncated Cabinet Available?
Fill for all Cabinet Types Proposed
Protection Class (IP Class):
Rack Color and Finish:
Altitude Installed:
Air flow in subrack (diagram required)
Describe Ventilation requirements:
Describe dustproofing provisions:
Electromagnetic compatibility (List standards & severity levels) (Submit Test Reports)
Noise Standards supported (Submit Test Reports )
Environmental standards supported (Submit Test Reports)
DATA REQUIREMENT SHEETS FOR OPTICAL AMPLIFIERS
Manufacturer: ______________________________
GENERAL PARAMETERS
(Fill for All Type of Amplifiers requred for 10G, 100G, 200G and above line rates in DWDM & DCI Box)
Type of Amplifier:
Source Power Supply requirements
Volts:
Current:
Gain medium:
Small Signal Gain:
Connection loss to transmission fibre:
Insertion Loss:
System Noise Figure:
Type of pump laser:
Pumping Wavelength:
Bit-Rate distance product:
Type of optical coupler:
Type of optical isolator:
Operating optical bandwidth:
Polarisation Gain Dependence:
Can the same optical amplifier Operate at:
Operating Bit Rates
Lower Limit:
Upper Limit:
"F" Type interface?
POWER AMPLIFIER, PRE AMPLIFIER, LINE AMPLIFIER (ALL PROPOSED TYPES)
Optical Input:
Signal wavelength:
Signal input power (max):
Signal input power (min):
End of Life :
Spectral width (-20 dB from peak):
Connector type:
Pulse shape:
Optical Reflectance:
Optical Output:
Signal output power (max):
Signal output power (min):
End of Life:
Connector type:
List and describe Monitor, Control and Alarm Points:
Describe Network Management Interface provisions:
Complete Accessibility from TMN
Accessibility as a Modules/ Card of the main Equipment in NMS?
Accessibility as a Sub-Equipment in the NMS?
Input Power Measurement via NMS?
Output Power Measurement via NMS?
Unreachability Alarm in NMS?
DATA REQUIREMENTS SHEETS for TMN
Manufacturer: _____________________________
Model Name & #:_____________________________
Whether all types of offered equipment are manageable from single TMN on a seamless end-to-end basis.
MPLS-TP
L2 Switch
Amplifiers
Hardware Configuration at Main Control Centre, including details of Processors, LAN, Routers, Printers etc.
Hardware Configuration at Back-up control centre including details of Processors, LAN, Routers, Printers etc
Describe the flow of data from Network Element to the Main and Back-up control centre, providing details of all the network components in between.
Describe features of TMN including:
Configuration Management
Fault Management
Performance Management
Security Management
Inventory Management
Software Management
Describe communication network required for TMN
Whether Back-up control centre can function independently?
Whether changes implemented by Main Control center automatically updated at Back-up Control centre and vice versa?
Describe configuration of the Voice Network
Describe Remote Access Solution
Solution Supports:
Storage of such logs/audit trail
DATA REQUIREMENTS SHEETS for Sync Clock
Manufacturer: _____________________________
Model Name & #:_____________________________
GNSS Reference Source (GPS and GLONASS/BEIDOU/GALILEO etc)
Compliance with:
Oscillator Long Term Stability (after 30 Days)
Oscillator Holdover Accuracy (after 4 Days)
No of Interfaces
Dual DC Power
Antenna Cable Length suppot
Cable Compensation
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html
01_First Envelope Attachments and Bid Form_Pkg-X.xlsx
xlsx • 1.78 MB
02_Second Envelope Bid Form and Schedules_Pkg-X.xls
xls • 5.29 MB
03_Attachment-3(QR).docx
docx • 0.15 MB
04_Attachment-20_KMP Declaration.doc
doc • 0.29 MB
05_Attachment-8_Manufacturer Authorization Form.docx
docx • 0.03 MB
06_Attachemnt-21_Affidavit for self-certification.DOCX
docx • 0.10 MB
07_Attachment-22_Certificate by Auditor.docx
docx • 0.10 MB
08_Attachment-23_Compliance to the process related to the e-RA.docx
docx • 0.10 MB
09_Attachment-25_Declaration regarding events encountered pursuant to ITB Clause 2.1.docx
docx • 0.11 MB
10_Legends for Units.pdf
pdf • 0.03 MB
01_Vol-II Sec_01.doc
doc • 0.16 MB
02_Vol-II Sec_02.docx
docx • 0.14 MB
03_Vol-II Sec_03.doc
doc • 0.15 MB
04_Vol-II Sec_04.doc
doc • 0.09 MB
05_Vol-II Sec_05.doc
doc • 0.22 MB
06_Vol-II Sec_06.doc
doc • 0.11 MB
07_Vol-II Sec_07.doc
doc • 0.14 MB
08_Vol-II Appendix-A cover page.docx
docx • 0.03 MB
09_Appendix-A (Implementation Plan).xls
xls • 0.12 MB
10_Vol-II Appendix-B Cover Page.docx
docx • 0.03 MB
11_Appendix-B (Telecom Map).jpg
jpg • 1.46 MB
12_Vol-II Appendix-C cover page.docx
docx • 0.03 MB
13_Appendix-C (BoQ).xlsx
xlsx • 0.01 MB
14_Vol-II Appendix-D Cover Page.docx
docx • 0.03 MB
15_Appendix-D (DRS).xlsx
xlsx • 0.27 MB
16_Vol-II Appendix-E cover page.docx
docx • 0.03 MB
17_Appendix-E (DoT Agreement).doc
doc • 0.18 MB
00_Cover Pages .doc
doc • 2.59 MB
01_Main Index_Volume-I.doc
doc • 0.15 MB
02_Section-I Invitation for Bids (IFB).docx
docx • 0.12 MB
03_Section-II Instructions to Bidders (ITB)-Rev 5.pdf
pdf • 1.95 MB
04_Section-III Bid Data Sheets (BDS).docx
docx • 0.16 MB
05_Annexure-A (BDS).docx
docx • 0.11 MB
06_Annexure-B (BDS).docx
docx • 0.18 MB
07_Annexure-C (BDS).docx
docx • 0.11 MB
08_Section - IV General Conditions of Contract (GCC) -S&I Rev 3-DCB.pdf
pdf • 1.93 MB
09_Section-V-Special Conditions of Contract (SCC).docx
docx • 0.13 MB
10_Appendix-I to SCC.pdf
pdf • 0.35 MB
11_Annexure-I to SCC.pdf
pdf • 0.63 MB
12_Section - VI Sample Forms and Proceedures.doc
doc • 0.80 MB
05_Second Envelope Bid Form and Schedules_Pkg-X_Rev_02.xls
xls • 5.54 MB
OBD_EXTN-IX_LETTER_Telecom_Pkg-X.pdf
pdf • 0.75 MB
05_Attachment 30_Certificate by Bidder.docx
docx • 0.02 MB
OBD_EXTN-VIII_LETTER_Telecom_Pkg-X.pdf
pdf • 0.76 MB
OBD_EXTN-VII_LETTER_Telecom_Pkg-X.pdf
pdf • 0.76 MB
OBD_EXTN-VI_LETTER_Telecom_Pkg-X.pdf
pdf • 0.75 MB
04_First Envelope Attachments and Bid Form_Pkg-X_Rev_03.xlsx
xlsx • 1.87 MB
OBD_EXTN-V_LETTER_Telecom_Pkg-X.pdf
pdf • 0.75 MB
OBD_EXTN-IV_LETTER_Telecom_Pkg-X.docx
docx • 0.16 MB
07_Form No 25 (Format of Value Addition Certificate).docx
docx • 0.10 MB
OBD_EXTN-III_LETTER_Telecom_Pkg-X.docx
docx • 0.16 MB
OBD_EXTN-II_LETTER_Telecom_Pkg-X.docx
docx • 0.24 MB
OBD_EXTN-I_LETTER_Telecom_Pkg-X.docx
docx • 0.24 MB
04_Attachment-27 (Undertaking).docx
docx • 0.10 MB
01_Amendment No.-I.pdf
pdf • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .