Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.5 LAccepted-AOC | L1 | Accepted-AOC Reasonable Lowest Tenderer | |
| 2 | L2₹13.9 L+₹84,636 (6.48%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Tenderer | |
| 3 | L3₹15.5 L+₹2.4 L (18.7%)Rejected-Finance | L3 | Rejected-Finance Not Lowest Tenderer | |
| 4 | L4₹17.6 L+₹4.5 L (34.5%)Rejected-Finance | L4 | Rejected-Finance Not Lowest Tenderer |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
18 Mar 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (East) Ferozepur Cantt
GE (East) Ferozepur Cantt
Repair to Summar Appliances and certain E/M under GE (East) Ferozepur Cantt
2024_MES_643332_1
8159/GE/E/FZR/2023-24/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (East) Ferozepur Cantt
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
Yes
GE (East) Ferozepur Cantt
₹36,000
Yes
28 Mar 2024
20 Feb 2024
20 Mar 2024
20 Feb 2024
18 Mar 2024
5 Mar 2024
Amount
WATER COOLER STORAGE TYPE Taking out existing compressor unit from the water cooler of capacity 40/80/120/150 Ltr of any make including removed of all other unserviceable parts/spares such as strainers, filter, capillary tubes suction /discharge pipe, thermostat switch, float valve, push cock running , starting capacitor, over load relay complete all as specified and directed.
Supply and fixing new compressor to water cooler of 150 Ltr/Hr cooling capacity including, jointing capillary tube and testing the compressor complete all as specified and directed.
Supply and fixing new compressor to water cooler of 60/120 Ltr/Hr cooling capacity including, jointing capillary tube and testing the compressor complete all as specified and directed.
Supply and fixing new compressor to water cooler of 40/80 Ltr/Hr cooling capacity including, jointing capillary tube and testing the compressor complete all as specified and directed.
M & L for servicing of water cooler any size and make including drain out water cleaning of water tank and cleaning of condersor coil with anti scaling solution complete all as specified and directed.
Charging of water cooler with R-134a,R-22,R-290,R-410 gas complete including leakage test and testing of water cooler on full load for 24 hrs continuously at site of any Make of any capacity complete all as specified and directed.
Repairing the water cooler / body by replacing rusted MS sheet body with new MS sheet of 16 SWG approx area 2.5 Sq ft complete including replacement of unserviceable channel legs, fan motar base complete all as specified and directed.
Taking out existing unserviceable fan motor of capacity 1/8 HP from water cooler, dismantling the motor and taking out old burnt copper winding wire, rewinding of fan motor with similar size super enamelled copper winding wire of Make of HTP/devidayal after providing 'E' class insulation material complete including replacement of unsv pad MS clamps, nut and bolt, varnishing & refixing the motor in the water cooler and testing of water cooler complete all as specified and directed.
Supply, fixing and connecting in replacement new fan motor of water cooler capacity 1/8 HP 230 Volt 50 c/s of make MIE/Khaitan/ Crompton Greaves complete all as specified and directed
Replacement of fan blades of fan motor of water cooler of make sidwal of capacity 150-40 ltr made out of GI Sheet complete all as specified and directed existing shape and size.
Supply,fixing and connecting the Running capacitor 36 MFD of water cooler of capacity 120/150 Ltr complete all as specified as directed.
All as per srl item 11 here in before but Starting capacitor 80-100 MFD complete all as specified and directed.
All as per srl item 11 here in before but Over load protector as per sample complete all as specified and directed.
All as per srl item 11 here in before but Starting relay 1/8 HP as per sample complete all as specified and directed.
All as per srl item 11 here in before but Thermostat switch for water cooler as per sample complete all as specified and directed.
All as per srl item 11 here in before Push cock brass HD chromium plated complete all as specified and directed.
All as per srl item 11 here in before but float valve ½” dia, brass with ball complete all as specified and directed.
All as per srl item 11 here in before but Rubber hose pipe/ for 1 ½” dia and 1.5 m long drain pipe complete all as specified and directed.
All as per srl item 11 here in before but Over load/relay complete box type Y-412 complete all as specified and directed.
REFRIGIRATOR 310/165 LTR & DEEP FREEZER 300/400 LTR Taking out existing compressor unit from the refrigerator of any capacity, of any make including removed of all other unserviceable parts/spares such as over load relay, bulb, strainer, thermostate switch, bulb holder, capillary tubes, freezer door complete all as specified and directed.
Taking out existing compressor unit from the deep freezer of any capacity of any make including removed of all other unserviceable parts/spares such as over load relay, bulb, strainer, thermostate switch, bulb holder, capillary tubes, freezer door complete all as specified and directed.
Supply & Fixing only company repaired compressor in lieu of defective compressor to refrigerator of 180/165 ltr capacity including jointing capillary and testing the compressor complete all as specified and directed
Supply & Fixing only company repaired compressor in lieu of defective compressor to refrigerator of 310/280 ltr capacity including jointing capillary and testing the compressor complete all as specified and directed
Supply & Fixing company repaired compressor in lieu of defective compressor to deep freezer of 200/250 ltr capacity including jointing capillary and testing the compressor complete all as specified and directed
Supply & Fixing company repaired compressor in lieu of defective compressor to deep freezer of 300/400 ltr capacity including jointing capillary and testing the compressor complete all as specified and directed
Supply and fixing new compressor to refrigerator of capacity 310 ltr including, jointing capillary tube and testing the compressor complete all as specified and directed.
Supply and fixing new compressor to refrigerator of capacity 195/165 ltr including, jointing capillary tube and testing the compressor complete all as specified and directed.
Supply and fixing new compressor to Deep freezer of capacity 320 ltr including, jointing capillary tube and testing the compressor complete all as specified and directed.
Supply and fixing new compressor to Deep freezer of capacity 250 ltr including, jointing capillary tube and testing the compressor complete all as specified and directed.
Charging of gas in Refrigerator/Deep Freezer with R-134a,,R-290,R-410 & R-600 gas complete including leakage test and testing of water cooler on full load for 24 hrs continuously at site of any Make of any capacity complete all as specified and directed.
Supply,fixing and connecting Plunger type relay 1/6 HP of REFRIGERATOR complete all as specified and directed.
All as per srl item No 31 here in before but Over load protector 1/6 HP. complete all as specified and directed.
All as per srl item No 31 here in before but Thermostat switch with knob - u-50-1018 complete all as specified and directed.
All as per srl item No 31 here in before but Glass cover heavy duty of Refrigerator capacity 310 ltrs complete all as specified and directed.
All as per srl item No 31 here in before but Repair to Freezer door for Refrigerator of Cap 310 ltr complete all as specified and directed.
All as per srl item No 31 here in before but Timer controller for Double door Refrigerator of Cap 310 ltr complete all as specified and directed.
All as per srl item No 31 here in before but Heating Elemnet for Double door Refrigerator of Cap 310 ltr complete all as specified and directed.
All as per srl item No 31 here in before but BioMetal for Double door Refrigerator of Cap 310 ltr
All as per srl item No 31 here in before but Supply Sensor for Double door Refrigerator of Cap 310 ltr complete all as specified and directed.
Supply & fixing PCB unit of Double Door Refrigertor 310/400 Ltrs of existing make complete all as specified and directed
Supply & fixing Butter box / any try any type and size as per sample complete suitable for whirlpool/Samsung refrigarater of Cap 310 Ltr complete all as specified and directed.
Supply,fixing and connecting the Running capacitor 06-15 MFD of Refrigerator/ Deep Freezer of capacity 120/150 Ltr complete all as specified as directed.
Supply,fixing and connecting, Replacement of the existing damage, choked Backside Condensor Coil from the Refrigerator of Cap 165/195 Ltr complete all as specified and directed.
Supply,fixing and connecting, Replacement of the existing damage, choked evaporator (Freezer) from the Refrigerator of Cap 310 Ltr of any Make
All as per srl item No 47 here in before but Replacement of the existing damage choked evaporator (Freezer) from the Refrigerator of Cap 165 Ltr complete all as specified and directed.
Taking out exiting unserviceable fan motor of capacity 1/8 HP from the cooler/Deep freezer/Refrigerator dismantling the motor and taking out old burnt copper winding and rewinding of blower motor with similar size of super enameled copper winding wire of make: HTP/ Devidayal after providing 'E' class insulator material including replacement of bushes, Name pad and varnishing refixing the motor in the DF Ref and testing of Desert Cooler complete all as specified and directed.
Taking out exiting unserviceable fan motor of capacity 1/8 HP from the cooler/Deep freezer/Refrigerator dismantling the motor and connecting new fan motor & Fan Blade complete all as specified and directed.
AIR CONDITIONER WINDOW TYPE 1.5 TON CAP Taking out existing serviceable window type Air conditioner of capacity 1.5 Ton of any make and capacity and refixing the same to its position after serviceing with anti scaling solution and cleaning complete including removal of all other unserviceable parts/spares such as strainer, pillar suction, starting capacitor overload Running capacitor relay etc and replaced with New parts as required complete all as specified and directed by Engineer-in-Charge.
All as per Srl item No 52 here in before but split type AC of Cap 1.5 Ton complete all as specified and directed.
Supply and fixing company repaired compressor in lieu of defective compressor to Air Conditioner of 1.5 Ton capacity including jointing compressor, capillary,, copper tubing as required and testing the compressor complete all as specified and as directed Note: Compressor will be repaired/replaced by OEM only.
Supply and fixing New compressor in lieu of defective compressor to Air Conditioner of 1.5 Ton capacity including jointing compressor, capillary, copper tubing as required and testing the compressor complete all as specified and as directed. Note: Compressor will be repaired/replaced by OEM only.
Supply and fixing New compressor in lieu of defective compressor to Air Conditioner of 2.0 Ton capacity including jointing compressor, capillary, copper tubing as required and testing the compressor complete all as specified and as directed. Note: Compressor will be repaired/replaced by OEM only.
Supply and fix in replacement of copper tubing for split type Air conditioner of 1/4 ", 1/2" or any size required at site Including Insulation Pipe all as specified and directed by Enge-in-charge
Charging of gas in Split/Window AC with R-134a,,R-22,R-32 & R-410 gas complete including leakage test and testing of water cooler on full load for 24 hrs continuously at site of any Make of any capacity complete all as specified and directed.
Dismantling taking out existing unserviceable fan motor of capacity 1/8 HP from window type Air conditioner/Split type dismantling the motor and taking out old burnt copper winding wire and rewinding of fan motor with similar size super enamelled copper winding wire of make. HTP/Devidayal after providing 'E' class insulation material complete including replacement of unsv rubber pad MS clamp nut bolt varnishing and refixing the motor in the A/C and testing of Air conditioner complete all as specified and directed.
Supply & fixing outer unit of spilt type AC 1.5 Tonn of existing make complete with condenser coil and compressor etc complete all as specified and directed.
Supply & fixing inner unit of spilt type AC 1.5 Tonn of existing make complete all as specified and directed
Supply & fixing PCB unit of spilt type AC of existing make complete all as specified and directed
M&L for repair of existing UNSV PCB unit of spilt type AC of existing make complete all as specified and directed
M&L for repair of existing UNSV PCB unit of Invertor Type spilt AC of existing make complete all as specified and directed
Supply & fixing in replacement of condenser/Evaporator coil of window type AC of 1.5 TR Capacity any make complete all as specified and directed
Supply & fixing in replacement of condenser/Evaporator coil of split type AC of 1.5 TR Capacity any make complete all as specified and directed
Supply, fixing and connecting Running capacitor 36-50 MFD complete all as specified and directed
All as per srl item No 67 here in before but Over Load protector No SR-1622 complete all as specified and directed
All as per srl item No 67 here in before but Starting capacitor 80-120 MFD complete all as specified and directed.
All as per srl item No 67 here in before but Starting Relay box type 1/8 HP SR-1622 complete all as specified and directed.
Taking out existing unserviceable fan motor from the Air conditioner supply fixing and connecting new fan motor 1/8 HP 230 Volt 50 C/s single phase complete including MS clamps and rubber pad , Fan Blade complete all as specified and directed.
M & L for shifting of air conditioner split type of any make from its original position to another position with and including any B & R work reqd and electric work required for it complete all as specified and directed.
M & L for shifting of air conditioner window type of any make from its original position to another position with and including any B& R work and electric work required for it complete all as specified and directed.
DESERT COOLER Taking out exiting unserviceable fan motor of capacity 1/8 HP from the desert cooler/ dismantling the motor and taking out old burnt Aluminium winding and rewinding of blower motor with similar size of super enamelled Alumium winding wire of make: HTP/ Devidayal after providing 'E' class insulator material including replacement of bushes, Name pad and varnishing refixing the motor in the Desert Cooler and testing of Desert Cooler complete all as specified and directed.
Taking out existing unserviceable Tulu pump (water pump) from the desert cooler supply and fixing connecting new Tulu pump 1/20 HP 230 Volt 50 C/S single phase of ISI Marked all as specified and directed
Taking out existing unserviceable fan motor from the desert cooler supply fixing and connecting new fan motor 1/8 HP 230 Volt 50 C/s single phase complete including MS clamps and rubber pad complete all as specified and directed.
Replacement of Desert Cooler front show grill made of PGI sheet 20 gauge duly painted all as specified and directed.
Replacement of Desert Cooler sides Shutters made of PGI sheet 20 gauge with pad sporting frame of size duly painted complete all as specified and directed. (Set of 3)
Replacement of capacitor 4 MFD, 230 volts 50 c/s of complete all as specified and directed
Replacement of 3 way PVC distributer complete all as specified and directed.
Taking out unserviceable fan blades of fan motor from the desert cooler and supply and fixing new blade of standard quality and as per existing size complete all as specified and directed.
Taking out existing serviceable fan motor and Tulu pump from the unsv body of desert cooler carefully supply of desert cooler body made out of GI sheet 18 gauge duly painted complete including shutters front show grill made out of GI sheet, wooden wool pad and refixing the fan motor and Tulu pump and testing complete all as specified and directed
Painting of desert cooler body at site of any make and capacity with one coat of approved quality synthetic enamelled paint over a coat of red oxide primer after cleaning of dust rust and preparation of surface both inside and 0ut side complete all as specified and directed.
Supply and fixing PVC pipe 15mm dia in each cooler complete all as specified and directed.
Taking out unserviceable supporting leg fan motor with screw and fixing new supporting legs as per existing size complete all as specified and directed
Replacement of wood wool pad, supporting wire frame (set of three) and fixing in Dessert cooler all as specified and directed.
REPAIR TO VOLTAGE STABILIZER OF CAPACITY 5 KVA MAKE - INTEG/NAYAR/ BLUE LINE COMPRISING THE FOLOWING: Dismantling and opening of main transformer and taking out of old burnt Aluminium winding wire, rewinding of main transformer with supper enamelled copper wire of make HTP/Devidyal after provisioning 'E' class insulator material varnishing and refixing complete all as specified and directed.
Dismantling of printed circuit board complex with condenser choke pre fixer and time delay relay and supply & fixing of new printed circuit board complete all as specified and directed.
Supply and fixing volt meter Display 0-300 volt single phase 230 volt complete all as specified and directed.
Supply and fixing Bakelite connector in main connection lead complete all as specified and directed.
REPAIR TO VOLTAGE STABILIZER OF CAPACITY 4 KVA OF MAKE - INTEG/ NAYAR/ ELECTRON COMPRISING OF FOLLOWING Dismantling and opening of main transformer and taking out of old burnt Aluminium winding wire, rewinding of main transformer with supper enamelled copper wire of make HTP/Devidyal after provisioning 'E' class insulator material varnishing and refixing complete all as specified and directed.
Dismantling of printed circuit board complete with condenser dioel pre fixer of time delay relay. and supply & fixing of new printed circuit board complete all as specified and directed.
Supply and fixing Bakelite connector in main connection lead complete all as specified and directed.
Supply and fixing volt meter Display 0-300 volt single phase 230 volt complete all as specified and directed.
REPAIR TO VOLTAGE STABILIZER OF CAPACITY 3 KVA MAKE- ELECTRON COMPRISING THE FOLLOWING :- Dismantling and opening of main transformer and taking out of old burnt Aluminium winding wire, rewinding of main transformer with supper enamelled copper wire of make HTP/Devidyal after provisioning 'E' class insulator material varnishing and refixing complete all as specified and directed.
Supply and fixing volt meter Display 0-300 volt single phase 230 volt make Bajaj or equivalent standard complete all as specified and directed.
Supply and fix Voltage stabilizer with 100% copper winding for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA complete all as specified and directed. Make: Microtek/Voltas/ V Guard.
Taking out carefully existing unserviceable copper PVC flexible 3 core cable and supply and fixing PVC sheathed copper cable 3 core of size 40/ 00.0076 complete all as specified and directed.
Taking out carefully existing unserviceable copper PVC flexible 3 core cable and supply and fixing PVC sheathed copper cable 3 core of size 70/ 00.0076 complete all as specified and directed.
M&L for replacement of UNSV existing reverse valve copper tubing as required on site for AC all as specified and directed.
Servicing and repairing of Aqua Guard water purifier of any cap with following replacment of parts complete all as specified and directed. Make :- Aqua guard. Note:- Unserviceable parts shall be measured as supply only. Labour element is included in the quoted Rate
Supply only Primary filter Small omplete all as specifid and directed.
All as per Srl item No 99 above but Primary filter Long complete all as specifid and directed.
All as per Srl item No 99 above but Carbon In Line Candle complete all as specifid and directed.
All as per Srl item No 99 above but Inline Sediment Candle complete all as specifid and directed.
All as per Srl item No 99 above but Long CTO Candle complete all as specifid and directed.
All as per Srl item No 99 above but Booster Pump 100 gpd complete all as specifid and directed.
All as per Srl item No 99 above but Booster Pump Head complete all as specifid and directed.
All as per Srl item No 99 above but SMPS Power Supply complete all as specifid and directed.
All as per Srl item No 99 above but Solenoidal Valve Copper complete all as specifid and directed.
All as per Srl item No 99 above but 100 GPD membrane complete all as specifid and directed.
All as per Srl item No 99 above but PVC pipe gripper at Primary filter ( set of two) complete all as specifid and directed.
All as per Srl item No 99 above but Replacement of Float Valve switch complete all as specifid and directed.
All as per Srl item No 99 above but PVC pipe of 1/4" as per exiting size complete all as specifid and directed.
All as per Srl item No 99 above but Primary filter case with clamps complete all as specifid and directed.
All as per Srl item No 99 above but Membrane Hosing A per Existing size complete all as specifid and directed.
PAWAN KUMAR GOVT. CONTRACTORS
Guru Kirpa Trading Company
M/s Sham and Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .