| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | ₹9.6 L Quoted ₹9.7 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹11.2 LRejected-Finance 0 H O SIDHARTH SHANKAR ROY DIGHA GHAT DIGHA PATNA BIHAR 800011 UDYAM BR 26 0085368 | PATNA | BIHAR | 800011 | ₹11.2 L | L2 | Rejected-Finance BEING L2 |
| 3 | L3₹12.5 LRejected-Finance | ₹12.5 L | L3 | Rejected-Finance BEING L3 |
| Sl No | Description | Qty | Unit | sapana enterprises L1 | Atharva Enterprises L3 | M/S KHUSHI ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00 | Material and labour in repair for sub main wiring complete with 2 run of 6 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC existing/new casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 6 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable item complete and making good the disturbed surfaces to match with existing all as specified and directed.
Note : - 02 run of 6 sqmm single core copper conductor cable and 01 run of 6 sqmm single core copper conductor and 01 run of PVC casing and caping shall be measured as one unit. | 145 | RM | 340 ₹49,300 | 420 ₹60,900 | 400 ₹58,000 |
| 1.01 | All as per item no 1 herein before but of size 2X4 sq mm and 1X4 sqmm all as specified and directed. | 155 | RM | 250 ₹38,750 | 300 ₹46,500 | 250 ₹38,750 |
| 1.02 | All as per item no 1 herein before but of size 2X2.5 sq mm and 1X2.5 sqmm all as specified and directed. | 95 | RM | 170 ₹16,150 | 200 ₹19,000 | 190 ₹18,050 |
| 1.03 | All as per item no1 herein before but of size 4X16 sq mm and 2X16 sqmm all as specified and directed. | 60 | RM | 950 ₹57,000 | 1,920 ₹1.2 L | 1,910 ₹1.1 L |
| 2.00 | Material and labour in repair for sub main wiring complete with 2 run of 6 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC existing/new conduit of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 6 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable item complete and making good the disturbed surfaces to match with existing all as specified and directed.
Note : - 02 run of 6 sqmm single core copper conductor cable and 01 run of 6 sqmm single core copper conductor and 01 run of PVC conduit shall be measured as one unit. | 140 | RM | 340 ₹47,600 | 420 ₹58,800 | 390 ₹54,600 |
| 2.01 | All as per item no 2 herein before but of size 2X4 sq mm and 1X4 sqmm all as specified and directed. | 150 | RM | 250 ₹37,500 | 300 ₹45,000 | 250 ₹37,500 |
| 2.02 | All as per item no 2 herein before but of size 2X10 sq mm and 1X10 sqmm all as specified and directed. | 70 | RM | 550 ₹38,500 | 730 ₹51,100 | 700 ₹49,000 |
| 3.00 | S&F PVC Conduit 25mm dia, medium grade with necessary Conduit Accessories such as Tee, Bend, Elbow, Junction Box, etc. ISI marked including taking down/out unserviceable PVC Conduit with Fittings, complete all as specified and as directed. | 200 | RM | 30 ₹6,000 | 35 ₹7,000 | 55 ₹11,000 |
| 4.00 | S&F PVC Casing & Cappings, ISI marked, heavy duty of size 25mm with all Fittings including taking down old unserviceable one, complete all as per specified and as directed. | 200 | RM | 25 ₹5,000 | 20 ₹4,000 | 45 ₹9,000 |
| 5.00 | S&F in repair Multi LED Street Light Fitting of capacity 35 Watt IP 65, having Die-cast Aluminium Housing, Weather Proof with Accessories and connecting up with and including PVC insulated Copper Conductor Cable 1.5 Sqmm, Single Core with bracket 25 mm dia GI medium grade pipe,1.2 mtr long including Taking down unserviceable Street Light Fittings from the bldg, complete all as specified and as directed. | 14 | EACH | 1,550 ₹21,700 | 1,400 ₹19,600 | 1,400 ₹19,600 |
Updated dates
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
19 Jan 2026, 6:00 pmClosed
GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIRS / MAINTANANCE OF SERVICE CONNECTION, DISTRIBUTION BOARD, BUILDING SUB MAIN WIRING, EARTHING AND ALLIED WORKS AT AF STN YEOUR UNDER GE AF THANE (3rd call)
2025_MES_734826_3
GE (AF) T-43 OF 2025-26 (8536)
Open Tender
Electrical and Maintenance Works
180 days
THANE
AS PER NOTICE OF TENDER
8 documents required · 8 mandatory
₹500
GE AF THANE
₹20,000
Yes
24 Mar 2026
29 Dec 2025
26 Jan 2026
29 Dec 2025
19 Jan 2026
5 Jan 2026
Material and labour in repair for sub main wiring complete with 2 run of 6 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC existing/new casing and caping of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 6 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable item complete and making good the disturbed surfaces to match with existing all as specified and directed. Note : - 02 run of 6 sqmm single core copper conductor cable and 01 run of 6 sqmm single core copper conductor and 01 run of PVC casing and caping shall be measured as one unit.
All as per item no 1 herein before but of size 2X4 sq mm and 1X4 sqmm all as specified and directed.
All as per item no 1 herein before but of size 2X2.5 sq mm and 1X2.5 sqmm all as specified and directed.
All as per item no1 herein before but of size 4X16 sq mm and 2X16 sqmm all as specified and directed.
Material and labour in repair for sub main wiring complete with 2 run of 6 sqmm, single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded duly colour coded cable drawn through and including PVC existing/new conduit of size 25mm width or above as required at site and accessories such as tee, corners,overlaping connector etc of suitable size fixed on surface of walls/roofs/ceiling and including 01 run of 6 sqmm single core, copper conductor cable 1100 volts grade, FRLS type, PVC insulated, unsheathed, flexible, multi stranded of green colour as earth continuity conductor connected to common earth dolly including removing old unserviceable item complete and making good the disturbed surfaces to match with existing all as specified and directed. Note : - 02 run of 6 sqmm single core copper conductor cable and 01 run of 6 sqmm single core copper conductor and 01 run of PVC conduit shall be measured as one unit.
All as per item no 2 herein before but of size 2X4 sq mm and 1X4 sqmm all as specified and directed.
All as per item no 2 herein before but of size 2X10 sq mm and 1X10 sqmm all as specified and directed.
S&F PVC Conduit 25mm dia, medium grade with necessary Conduit Accessories such as Tee, Bend, Elbow, Junction Box, etc. ISI marked including taking down/out unserviceable PVC Conduit with Fittings, complete all as specified and as directed.
S&F PVC Casing & Cappings, ISI marked, heavy duty of size 25mm with all Fittings including taking down old unserviceable one, complete all as per specified and as directed.
S&F in repair Multi LED Street Light Fitting of capacity 35 Watt IP 65, having Die-cast Aluminium Housing, Weather Proof with Accessories and connecting up with and including PVC insulated Copper Conductor Cable 1.5 Sqmm, Single Core with bracket 25 mm dia GI medium grade pipe,1.2 mtr long including Taking down unserviceable Street Light Fittings from the bldg, complete all as specified and as directed.
S & F in repair Loadline Distribution board, TP&N vertical, with Bus bars, 200A, 415V CapNetural links,blanking plates, double door 8 way, with MCCB 63 to 100 Amps as incommer and SP/DP/TP MCB as outgoing and electrically connecting up ,complete all as specified and as directed by Engr-in-charge.
S & F in repair Loadline Distribution board, TP&N vertical ,with Bus bars, 200A, 415V Netural links,blanking plates, double door 4 way, with MCCB 63 to 100 Amps as incommer and SP/DP/TP MCB as outgoing and electrically connecting up ,complete all as specified and as directed by Engr-in-charge.
S & F in repair Distribution board, SP&N ,Prewired ,Netural links,blanking plates, double door 4 way, with provision for MCB SP&N as incommer and SP/DP MCB as outgoing and electrically connecting up ,complete all as specified and as directed by Engr-in-charge.
S & F in repair Distribution board, SP&N ,Prewired ,Netural links,blanking plates, double door 8 way, with provision for MCB SP&N as incommer and SP/DP MCB as outgoing and electrically connecting up ,complete all as specified and as directed by Engr-in-charge.
S & F in repair MCB SP 6 to 32 Amps 240 volts 50 HZ having 10 KA ,complete all as specified and as directed by Engr-in-charge.
S & F in repair MCB SPN 40 Amps 240 volts 50 HZ having 10 KA ,complete all as specified and as directed by Engr-in-charge.
S&F in repair MCB SPN 240 volt,50Hz,63 Amp,C Curve,10kA breaking capacity ,complete all as specified and as directed by Engr-in-charge.
S & F in repair MCB FP 40 Amps/63Amps 240 volts 50 HZ having 10 KA ,complete all as specified and as directed by Engr-in-charge.
S&F in repair DB box with protected power unit rating 16-25 Amps 240volt 50HZ as per Havells cat part no-DHDUCDP0253016-25 or equivalent as per Approved.
S & F in repair RCCB DP,30 mA, 25 Amps 240 volts 50 HZ having ,complete all as specified and as directed by Engr-in-charge.
Taking down the unserviceable MCCB, Supply and fixing MCCB TP/FP pole with thermal Release range 40/63 Amps, 16KA, 415V, 50 Hz including extension bar for connection cable, ,complete all as specified and as directed by Engr-in-charge.
Taking down the unserviceable MCCB, Supply and fixing MCCB TP/FP pole with thermal Release range 100-125 Amps, 16KA, 415V, 50 Hz including extension bar for connection cable, ,complete all as specified and as directed by Engr-in-charge.
M & L in repair for Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth of not less than 1.5 mtr below ground level connection to and including 4mm dia (8 SWG) GI earth wire from earth plate to main switch board including necessary GI bolts, nuts, check nuts, washers, thimble etc to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to DBs /LT Panel wlith provision of charcoal and salt all as per electrical plate No 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade) excavation and earth work returning , filling, ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion.Note:1.After completion if test results are nor satisfied, earthing should be redone by contractor without any extra cost. 2. Contractor should quote the rate deemed to be included with testing.
S&F in repair sheet metal plug & socket DB, SP, with a two pin and earth plug with socket, 230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair LED light fitting 1x 40 Watt flameproof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistant toughened glass, with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed.
S&F in replacement of Energy saving 9/10 watt environmental friendly, ultra modern, energy saving, surface mounted, decorative oval bulk head edge-lit LED luminaire comprising of high brightness LEDs, IP 65 protection fixed on wall complete all as specified and as directed by Engineer-in-charge.
Supply,lay and testing in replacement of over head line or cable XLPE insulated,galvanised steel strip armoured,1100 volts grade with multistranded aluminium conductor of cross-sectional area 50 sqmm; 3.5 core laid in trenches/pipes/ducts/walls and connection with necessary cable lugs and glands, nuts, bolts and washers etc and testing including removing old unserviceable item complete all as specified and directed. Note for item No 27 to 29- (i) Excavation & Earth work,sand cushioning, cable cover and protection pipe shall be measured and paid separately. (ii) The cable shall be in one length unless otherwise directed by the GE.
All as per item No.22 above but of size 70 sqmm, 3.5 core
All as per item No.22 above but of size 35 sqmm, 3.5 core
Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all as specified and directed.
Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed
Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed
Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed. Note: Punned thickess i.e 18 cm shall be measured for paymeny purpose.
Supply and laying unreinforced precast factory made concrete cable cover, class LV, Type -I, flat, size 250mm x 150mm x 40mm, complete all as specified and directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
TD8536.pdf
Tender Documents • 2.03 MB
BOQ_835899.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid