| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹26.6 LAccepted-AOC R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | 1 | Accepted-AOC BEING L1 | |
| 2 | 2₹27.8 L+₹90,420 (3.36%)Rejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | 2 | Rejected-Finance BEING L2 | |
| 3 | 3₹37.5 L+₹10.6 L (39.2%)Rejected-Finance | 3 | Rejected-Finance BEING L3 | |
| 4 | Rejected-Technical 15A 9 CHOWBHAGA ROAD KOLKATA KOLKATA 700039 | KOLKATA | WEST BENGAL | 700039 | - | Rejected-Technical REFER SUMMARY |
Tender Value
Refer Docs
EMD Value
₹64,000
Closing Date
30 Jan 2023, 6:00 pmClosed
GE AF UDHAMPUR
GE AF UDHAMPUR
AMC (Annual Maintenance Contract) for lift of high rise Building along with certain misc works at 39 Wing AF Stn Udhampur.
2023_MES_572664_1
GE/AFU-60/2022-23
Open Tender
Civil Works
Item Rate
365 days
GE AF Udhampur
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE AF UDHAMPUR
₹64,000
Yes
30 Mar 2023
3 Jan 2023
1 Feb 2023
3 Jan 2023
30 Jan 2023
17 Jan 2023
3 Jan 2023 - 10 Jan 2023
Amount
Note : for item No 1,&2 (i) All items required pertaining to these lift shall be deemed to be included quoted rate except items covered in item No 3 to 27 (are and any other defective items shall be measured & paid separately. (ii) The contractor will have to submitt MOU from the OEM i.e. thyssonkrupp elevator India Pvt Ltd, The contractor shall submit constent/readiness letter from the OEM on/before DRT,otherwise financial bid of the bidder shall not be opened. (iii) Contractor will conclude AMC with OEM and copy of the agreement will be submitted to Engr-in-Charge and GE before commencement of the AMC, No payment will be made to contractor with submission of valid AMC agreement. (iv) Testing & certifcate of all lift by lift inspecting officer giving certificate for its safety for 12 months (v) Lift to be testing in presence of user & certificate to this effect for payment purpose. (vi) Contractor will produce a register signed by user rep towards proper functioning of lift every month. Payment will be released only on satisfactory functioning of lifts
(vii) Periodical servicing by rep of OEM of the lift to maintain in a reliable, safe and efficient manner using latest techniques & experts by carrying out planned maintenance in a systematic and control manner by regularly examing, testing, lubricating and adjusting all the items of the lifts with including repair/replacement of all defective parts i.e. all type of mechanical and electrical items, check that lift stop in downward direction properly with 25% overload with operation of the “emergency” stop when lift is moving at full speed, check and lubricate by grease cup or top up oil on sleeve type bearing on motor shaft, deflector sheave shaft, governor pulley, check and lubricate sheave of governor tensioning pull at the pit, controller-clean contracts and shields with carbon tears chloride move relay armature by hand for movement and see that contracts are aligned, replace carbon contacts if worn out, check fuses of controller and mains, brake oil in dash pots, check flexible leads to relay, check and adjustment carbon bushes spring pressure commutator reset brushes, greasing bearing AC motor lubricating bearing, cleaning ventilation passenger inspect for tray noises lubricate bearing and top up oil in gear box (viii) If complaint not attended by rep of OEM within one hour panelaty of Rs 500/ per hour will be charged. (ix) OEM will ensure that lift machenic deployed must have minimum ITI cert with experience of such type of works (x) If lift become unserviceable under srl item no 1&2 after inspaction during any month , same shall be repaired by company rep/contractor within 24 hrs and nothing extra shall be addmissible for additional visit will be paid except spare parts Brake: Clean if oil and trace source of oil leakage, adjust clearance between shoes and drum, clean contacts, check tape safety switch, lubricate shaft bearing. Governor : Check that the levers works smoothly, check that electrical contacts open before the rope locked.
Ropes : Check condition of hoist rope and governor rope. Check slack rope if too dry. Hoist way lubricate guides and guide shoes: Check that the buggers are in proper position and measure & record counter weight buffer cleans with car at the top. Retring car and lock : Check operation of the car and lock from the top and each landing. Check that retring car solenoid is not getting over heated and that movement of car is smooth, check all the locks are functioning properly mechanically and electrically after opening the covers check all set screws and spring and replace if necessary the lever should lock the brake properly. Check that the retiring car does touch the lock roller at the landing which is being passed, check that car gate switch operated properly, check condition of traveling cable and termination at junction boxes, check guide clamps and adjust , after physical inspection, get the lift to over travel by holding from the controller and see that the switches operate properly, check door closer safety , clean and adjust, if necessary, lubricate top track and door motor and linkage, check that landing doors can be opened by emergency keys, Machine room, Check and adjust overload relay and phase failure relay, check power wiring termination in switch, motor, controller and power switching relays, check lubricants of all equipments. (viii) Contractor will produce a visit schedule in which he will intimate that how many visit he will scheduled during the month.
S&F in repair of lead acid battery 12 volts, 17 AH, type EP-42-12 suitablefor lift. Make power safe/exide/okaya/amron
S&F in repair of LED lights 3 o 5 watt complete all as specified and directed.
Supply and fixing in repair infrared red beam sensor for thyssonkrup elevator complete all as specified and directed. Make Thyssenkrupp or suitable make for thyssenkrupp.
Supply and fixing in repair Inverator Door Drive AC 220v1.3A lp20Nice-900 -D-sop2 Monarch for thyssonkrup elevator complete all as specified and directed. Make Thyssenkrupp or suitable make for thyssenkrupp.
Supply and fixing in repair Inverator Main DRIVE VVF13 pasanger for thyssonkrup elevator complete all as specified and directed. Make Thyssenkrupp or suitable make for thyssenkrupp.
Supply and fixing in repair Inverator Main DRIVE VVF08 pasanger for thyssonkrup elevator complete all as specified and directed. Make Thyssenkrupp or suitable make for thyssenkrupp.
Supply and fixing in repair mother board for thyssonkrup elevator complete all as specified and directed. Make : Thyssenkrupp or suitable make for thyssenkrupp.
Supply & fixing in repair MCU card for Thyssenkupp elevator complete all as specified and directed.
Supply & fixing in repair CCU card for Thyssenkupp elevator complete all as specified and directed.
Supply & fixing in repair of Emergency Alarm Set complete all as specified and directed. Make : Thyssenkrupp or suitable make for thyssenkrupp.
Supply & fixing in repair of Contractor LC1d18f7 110 Vac Set complete all as specified and directed. Make : Thyssenkrupp or suitable make for thyssenkrupp.
Supply & fixing in repair Contractor LC1d12 110 Vac Set complete all as specified and directed. Make : Thyssenkrupp or suitable make for thyssenkrupp.
Supply & fixing in repairof intercom phone set complete all as specified and directed. Make : Thyssenkrupp or suitable make for thyssenkrupp.
Supply & fixing in repair of Reed Switchcomplete all as specified and directed. Make : Thyssenkrupp or suitable make for thyssenkrupp.
Supply & fixing in repair of COP Display complete all as specified and directed. Make : Thyssenkrupp or suitable make for thyssenkrupp.
Supply & fixing in repair of UPS3000SUA complete all as specified and directed. Make : Thyssenkrupp or suitable make for thyssenkrupp.
Supply & fixing in repair of CHOKE complete all as specified and directed. Make : Thyssenkrupp or suitable make for thyssenkrupp.
Supply & fixing in repair of Emergecy car light unit complete all as specified and directed. Make : Thyssenkrupp or suitable make for thyssenkrupp.
Supply & fixing in repair of MCCB 100 Amps 4pole 36KA Ics 18kA lec60947-2 Utilization category Aas per existing size complete all as specified and directed.
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium condutor 1100 volts grade of size 50 Sqmm 3.5 core laid on walls/floors or in air with saddles and gutties complete all as specified and directed.
Disconnecting and taking down old unserviceable of power command control HM/211and M&Lfor microproceaser based power command controlHMI211of DG set AMF Panel of capacity 320 KVA complete including digitaly voltage regulation (full wave rectified single phase (line to line) sencing digital engine speed complete all as specified and directed.
Supply & fixing in repair of MCCB 63 Amps 4pole 25KA LCS 12.5KA Utilization category Aas per existing size complete all as specified and directed.
Note : Total amount of Schedule of Credit for retrieved material mentioned on General summary of Tender documents in PDF format will be deducted offline during acceptance of Tender
M/s Dhapola Elevator and Engineering
N K BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .