Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹9.9 L+₹2.8 L (38.9%)Rejected-Finance AT AMRITPUR PO NB CHILKA DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹11.0 L+₹3.8 L (53.3%)Rejected-Finance FLAT NO 404 A WING HILL SIDE RESIDENCY BEHIND KIRTI POLICE SOCIETY KATRAP BADLAPUR EAST DIST THANE MAHARASHTRA 451503 | 451503 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹12.5 L+₹5.4 L (75.0%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
18 Nov 2022, 6:00 pmClosed
Garrison Engineer Chilka
Garrison Engineer Chilka, PO INS CHILKA, KHURDA, ODISHA 752 037
REPAIR AND MAINTENANCE OF SPLIT AC, WINDOW AC, TOWER AC, WATER COOLER, REFRIGERATORS OF VARIOUS CAPACITIES AND OTHER CONNECTED WORKS AT INS CHILKA UNDER GE CHILKA
2022_MES_558555_1
GE/CHL/8834 OF 2022-23
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer Chilka
MES Enlisted contractor Class E
Category C (i)
7 documents required · 7 mandatory
₹500
Garrison Enginner Chilka
₹17,000
Yes
24 Dec 2022
19 Oct 2022
25 Nov 2022
19 Oct 2022
18 Nov 2022
5 Nov 2022
19 Oct 2022 - 26 Oct 2022
Amount
S&F of 1.5 TR AC compressor reciprocating or rotary or scroll type compressor hermetically sealed type with overload protector including taking out existing old unserviceable compressor from its position in Split/ window AC including testing complete all as specified and as directed.
S&F of 2 TR AC compressor reciprocating or rotary or scroll type compressor hermetically sealed type with overload protector including taking out existing old unserviceable compressor from its position in Split/ window AC including testing complete all as specified and as directed.
S&F of 3 TR AC compressor reciprocating or rotary or scroll type compressor hermetically sealed type with overload protector including taking out existing old unserviceable compressor from its position in Split AC including testing complete all as specified and as directed.
S&F of 4 TR AC compressor reciprocating or rotary or scroll type compressor hermetically sealed type with overload protector including taking out existing old unserviceable compressor from its position in Split AC including testing complete all as specified and as directed.
S&F of compressor reciprocating or rotary or scroll type compressors hermetically sealed type with overload protector including taking out existing old unserviceable compressor from its position in 120 to 180 Litre refrigerator including testing complete all as specified and as directed.
S&F of compressor reciprocating or rotary or scroll type compressor hermetically sealed type with overload protector including taking out existing old unserviceable compressor from its position in 240 to 270 Litre refrigerator including testing complete all as specified and as directed.
S&F of compressor reciprocating or rotary or scroll type compressor hermetically sealed type with overload protector including taking out existing old unserviceable compressor from its position in 40 to 80 Litre water cooler including testing complete all as specified and as directed.
S&F of compressor reciprocating or rotary or scroll type compressor hermetically sealed type with overload protector including taking out existing old unserviceable compressor from its position in 60 to 120 Litre water cooler including testing complete all as specified and as directed.
S&F of compressor reciprocating or rotary or scroll type compressor hermetically sealed type with overload protector including taking out existing old unserviceable compressor from its position in 150 Litre water cooler including testing complete all as specified and as directed.
S&F of 1/5HP, 825-1400 RPM condenser fan motor or Blower Motor pre wired, single phase, AC supply, 230 volts, 50 Hz, corrosion resistant with built- in thermal protection (as per sample) complete all as specified and as directed
S&F in repair of condensor Fan blade assembly made up of aluminium or hard PVC of suitable size as existing at site complete as specified and as directed.
S&F in repair of 10 mfd running capacitor for condensor fan of suitable size as existing at site complete as specified and as directed.
S&F in repair of 4 mfd running capacitor for condensor fan of suitable size as existing at site complete as specified and directed.
S&F in repair of 36 mfd running capacitor complete as specified and as directed.
S&F in repair 45+4 mfd running capacitor complete as specified and as directed.
S&F in repair 50/55+4 mfd running capacitor complete as specified and as directed.
S&F 80-100 mfd starting capacitors including taking out old unserviceable capacitor complete all as specified and directed.
S&F 100-120 mfd starting capacitors including taking out old unserviceable capacitor complete all as specified and directed.
Supply and charging of refrigerant R-22 industrial grade in AC, Refrigerator, Water coolers as required complete all as specified and as directed
Supply and charging of refrigerant R-134A industrial grade in AC, Refrigerator, Water coolers as required complete all as specified and as directed.
S&F in repair thermostat for AC / Refrigerator / Water Coolers electronic type with temperature range of the equipment specification with auto cut-off and auto reset feature complete all as specified and as directed.
S&F in repair timer switch with auto reset feature for Air conditioners and refrigerators complete all as specified and as directed
S&F in repair Bimetalic fuse complete all as specified and as directed
S&F in repair of OLP Kit 0072/73 suitable for water cooler/refrigirator of various capacities complete all as specified and as directed
S&F in repair Flare valves of size 1/4 inch as existing at site complete all as specified and as directed
S&F in repair Flare valves of size 5/8 inch as existing at site complete all as specified and as directed
S&F Reversing valves of any size as existing at site complete all as specified and as directed
S&F in replacement of starting relay for water cooler/Refrigirator/AC as existing at site of required capacity complete all as specified and as directed.
S&F in replacement of screw/ pin type fridge bulb 240 volts 10 watt for any type of refrigerator all as specified.
S&F in replacement of knob for window/ split type AC as per existing at site of various makes complete all as specified and as directed.
S&F in replacement of swing motor 240 volts, 50 HZ, 3-8 watts for split/window type ACs of various capacities complete all as specified and as directed.
S&F in replacement of circuit board of split/window AC of capacity 1.5/2/3TR complete all as specified and as directed .
S&F in replacement of cordless remote controller Kit including all accessories for split/ window type AC of 1.5/ 2 / 3 ton complete as specified and as directed.
S&F in replacement of Bimetal over load relay (relay range suitable for MNX18 contactor) including disconnecting & reconnecting inter connections complete all as specified and as directed
Supply and replacement of magnetic EPDM rubber gasket for refrigerator doors of industrial grade ISI marked complete all as specified and as directed.
S&F in replacement of Contactor 2/3 pole 20 to 30 Amps 240 Volt/415 Volt AC supply as existing site l complete all as specified and as directed.
S&F in repair Vertical / Horizontal louvers step motor as existing at site complete all as specified and as directed.
S&F in repair bush / bearing of required size as existing at site complete all as specified and as directed
S&F PVC drain pipe 32/40 mm dia ISI marked complete all as specified and as directed.
S&F PVC drain pipe 20mm dia ISI marked complete all as specified and as directed.
Supply and replacement of drain tray for refrigerator of required size and capacity as existing at site complete all as specified and as directed.
S&F 1/4 inches internal dia copper tube of thickness 1.20 - 1.50 mm , industrial grade ISI marked for refrigerator/watercoolers/ACs complete all as specified and as directed .
S&F 3/8 inches internal dia copper tube of thickness 1.20 - 1.50 mm , industrial grade ISI marked for refrigerator/watercoolers/ACs complete all as specified and as directed .
S&F 5/8 inches internal dia copper tube of thickness 1.20 - 1.50 mm , industrial grade ISI marked for refrigerator/watercoolers/ACs complete all as specified and as directed .
M&L for gas welding of copper tubes with copper or silver or any other metal as filler material as per site requirementafter required cutting and preperation before welding complete all as specified and as directed.
S&F in replacement of wall mounted 4 KVA single phase voltage stablizer low voltage corrector with input voltage of 160 to 260 volts and out put voltage 240 + 1% complete all as specified and as directed. Make :- V-Guard/Shakti/Zenith
S&F in replacement of wall mounted 5 KVA single phase voltage stabilizer low voltage corrector with input voltage of 160 to 260 volts and out put voltage 240 + 1% complete all as specified and as directed. Make :- V-Guard/Shakti/Zenith
S&F in replacement of floor mounted three phase 415 Volt voltage stabilizer of 6.0 KVA low voltage corrector with input voltage of 380 to 415 volts and out put voltage 415 + 1% of complete all as specified. Make :- V-Guard/Shakti/Zenith
S&F copper condensor coil unit complete as existing at site for ACs / Water Coolers / Refrigerators of any capacity complete all as specified and as directed.
S&F electrical box assembly complete unit for Our door unit / Indoor unit for AC of 1 Ton to 3 Ton Split/ Window AC complete all as specified and as directed .
S&F terminal blocks 3/4/6 pole and 20 to 30 Amps for outdoor / indoor Unit for AC as existing at the site complete all as specified and as directed.
S&F Out door coil sensor unit for AC/Water Cooler/ Deep Fridgers as existing at the site complete all as specified and as directed.
S&F in replacement of 2.5 Sqmm three core multistranded copper conductor flexible cable PVC insulated, PVC sheathed 1100 volts grade complete all as specified and as directed. Make :- Polycab/Havells/Plaza
S&F in replacement of 4 Sqmm four core multistranded copper conductor flexible cable PVC insulated, PVC sheathed 1100 volts grade complete all as specified and as directed. Make :- Polycab/Havells/Plaza
S&F in replacement of MCB SP 6 to 32 Amps 230volts, AC complete all as specified and as directed. Make:- C&S/ Standard/L&T
M&L for taking out Indoor/ Out-door units of AC / Water Coolers/ Deep freezer / Tower AC including shifting and re-installation at any other location as decided by Engineer-in-charge complete all as specified and as directed.
M&L for removing of water cooler of various capacity from the existing position, servicing with HCL acid and water solution and refixing the same in its original position with insulating material complete all as specified and as directed.
M&L for servicing of Air conditioning units of any size in existing position, cleaning it from inside completely, checking and fixing any minor damaged article, electrical wiring etc including testing complete as specified and directed
S&F in replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole,20 amp, 240volt MCB complete all as specified and as directed.
S&F in replacement of indoor unit of 1.5/2 ton of Split AC complete with fan motor, remote as existing on ground including testing complete all as specified and as directed. Make:- Godrej/Blue star/Voltas /Hitachi /Daikain
M&L for repair to existing circuit board of split/window AC of capacity 1.5 or 2 or 3 TR to make it fully functional complete as specified and directed
M&L for removing of Split/Window AC of various sizes from the room, servicing(Chemical servcing) with HCL acid and water solution and refixing the same on its original position with insulating complete all as specified and as directed.
S&F in replacement of circuit board PCB (indoor and outdor) of inverter type split AC of capacity 1.5/ 2 TR complete all as specified and as directed.
S&F in repair float valve of any size for water cooler as per site requirement complete all as specified and as directed.
M&L for repair to existing stabilizers of any capacity as per site requirement complete all as specified and as directed.
Notes : (i) The contractor shall generally be avaliable for 24 hours call back services but strictly ensure availability of his responsible representative during the entire period of the contract for attending all types of complaints. He shall promptly attend complaint with in 2 hour and rectify the same at that time Excepect Major defects (Compressor and Condensor) and the complaint shall not be kept pending for more than 2 hours of intimation to contractor via e-mail/electronic media. The contractor shall obtain the signature of the Eng-in-charge in token of satisfactory completion of defects. (ii) In case of dealy in the rectification of any defects for more than 2 hours for minor defects and more than 72 hours for major defects, the GE may at his absolute discretion to impose on the contractor to pay to the department a penalty of Rs 5,000/- for minor defects and Rs 10,000/- for major defects towards inconvenience caused to the users. The decision of the GE as to whether a particular defect occured is minor or major will be the final and binding. The above penalty shall be in addition to the provision made in condition 50 of IAFW-2249.
PABITRA MOHAN PARIDA
M/S SOMANATH ENTERPRISES
M/S KAMAL KEE ENGINEERS WORK
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .