The Superintending Engineer
The Superintending Engineer, PWD., Buildings Construction and Maintenance Circle,Tiruvannamalai-4.
Construction of New Collectorate and Other Office Buildings in Master Plan Complex at Veeracholapuram in Kallakurichi District.
2024_PWD_473113_1
11/TVM-CLE/24-25/1/ Dt.30.07.2024
Open Tender
Civil Works - Buildings
540 days
Veeracholapuram
Please refer Tender documents.
14 documents required · 14 mandatory
₹0
₹64.2 L
2 Jan 2025
15 Aug 2024
21 Aug 2024
15 Aug 2024
21 Aug 2024
15 Aug 2024
Amount
Earth work excavation for foundation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 10 mts and initial lift of 2 mts. and clearing and levelling the site, etc., complete complying with standard specification.
Earth work open excavation in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification.
Supplying and filling in foundation, basement, etc with filling stone dust in layers of not more than 15cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers.
Supplying and filling of conveyed well gravel by lorry in basement filling including stacking for premeasurement, conveyance loading and unloading charges and all other incidential charges and including filling laying watering and consolidating etc., complete as directed by the dept., Officers and complying with standard specification.
Providing and laying sand gravel mix as per mixed to a consolidated thickness of 100mm, using 0.67 cm of sand / M sand and 0.69 cm of gravel for every cum consolidated sand gravel mix to give a soaked CBR valve of minimum 20 including cost and conveyance of sand and gravel from approved sources to work site and premeasurement including labour charges for mixing the required quantities of sand and gravel to the proportion and consistency using soft portable water to keep up optium moisture content over day and night mixing well on the next morning water sprinkler and laying watering including all leads spreading the mix in layers not less than 10cm and not more than 15 cm watering and consolidating including labour charges for mixing spreading and hire charges fuel charges and running charges for power rollers, water sprinkles and all other tools and plants etc. complete complying with standard specifications.
Refilling with excavated earth other than M-sand with an initial head load of 100 mts. and depositing the earth as shown by the departmental officers in layers of not more than 15 cm thick well rammed, watered and consolidated etc. complete complying with standard specification.
Cement Concrete 1:5:10 (One Cement, Five M-sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification.
Cement Concrete 1:5:10 (One Cement, Five M-sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for flooring including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and curing etc. complete complying with standard specification.
Brick work in Cement Mortar 1:3 (One Cement and Three M-Sand) using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9" x 4-3/8" x 2-3/4" for foundation and basement including curing, etc., complete complying with standard specification.
For Foundation and Basement
Brick work in Cement Mortar 1:5 (One Cement and Five M-Sand) using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9" x 4-3/8" x 2-3/4" for foundation and basement including curing, etc., complete complying with standard specification.
For Foundation and Basement
For Superstructure in Ground Floor
Brick work in Cement Mortar 1:6 (One Cement and Six M-Sand) using best quality of Second Class Ground Moulded Chamber Burnt Bricks 9" x 4-3/8" x 2-3/4" for foundation and basement including curing, etc., complete complying with standard specification.
For Foundation and Basement
For Superstructure in Ground Floor
For Superstructure in First Floor
For Superstructure in Second Floor
For Superstructure in Third Floor
For Superstructure in Fourth Floor
For Superstructure in Fifth Floor
For Superstructure in Sixth Floor
For Superstructure in Seventh Floor
For Superstructure in Eighth Floor
Brick partition walls of 11.50cm thickness using best quality Second Class Ground Moulded Chamber Burnt Bricks of size 9" x 4-3/8" x 2-3/4" in Cement Mortar 1:3 (One Cement and Three M-Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately)
For Superstructure in Ground Floor
For Superstructure in First Floor
For Superstructure in Second Floor
For Superstructure in Third Floor
For Superstructure in Fourth Floor
For Superstructure in Fifth Floor
For Superstructure in Sixth Floor
For Superstructure in Seventh Floor
Damp proof course with Cement Mortar 1:4 (One Cement and Four M-sand) 12mm thick mixed with best approved quality water proofing compound conforming to Indian Standard specification as specified by the departmental officers at 2% by weight of cement used and finishing, curing etc. complete complying with standard specification.
Supplying and erecting steel centering including necessary supports for plane surfaces for Reinforced Cement Concrete works such as column footings, column pedestals, plinth beams, grade beams, staircase steps, etc. which require only nominal strutting using mild steel sheets of size 90cm x 60cm and 10 BG stiffened with welded mild steel angles of size 25mm x 25mm x 3 mm for boarding, laid over silver oak joists of size 10cm x 6.5cm spaced at about 75cm centre to centre or at suitable intervals etc. complete in all floors complying with standard specifcation. (Payment for centering shall be given after the concrete is laid)
Supplying and erecting centering for sides and soffits including necessary supports and strutting upto 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at abote 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specificaiton. (Payment for centering shall be given after the concrete is laid)
For plane surfaces such as RCC floor slab, roof slab, beams, lintels, bed blocks, landing slab, waist slab, portico slabs and beams, etc.
For plane surfaces such as rectangular or square RCC columns, sunshades, top and bottom slab of RCC boxing, etc.
For plane surfaces such as vertical slab, side slabs of boxing, vertical drops, facia, vertical wall, etc.
Centering for curved surfaces of all RCC items of work.
Providing additional strutting to centering of RCC slabs of plain surface for every additional 1.0 metre height or part thereof but not less than 30 cm, over the initial 3.00 metre height from floor level using casurina props of 10cm to 13cm dia including cross bracing etc., complete complying with standard specification and as directed by the department officers.
Providing and laying in position, Standardised Concrete Mix M-20 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 325 kg/mᶾ and maximum water cement ratio of 0.55, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
For Foundation and Basement
For Superstructure in Ground Floor
For Superstructure in First Floor
Providing and laying in position, Standardised Concrete Mix M-25 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 350 kg/mᶾ and maximum water cement ratio of 0.50, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
For Foundation and Basement
For Superstructure in Ground Floor
For Superstructure in First Floor
For Superstructure in Second Floor
For Superstructure in Third Floor
For Superstructure in Fourth Floor
For Superstructure in Fifth Floor
For Superstructure in Sixth Floor
For Superstructure in Seventh Floor
For Superstructure in Eighth Floor
Providing and laying in position, Standardised Concrete Mix M-35 Grade in accordance with IS:456-2000, using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement content of 425 kg/mᶾ and maximum water cement ratio of 0.45, including admixture (plasticiser / super plasticiser) in recommended proportions as per IS:9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability with about (5.0 cu.m.) 7730 kg. of 20mm machine crushed stone jelly and with about (3.3 cu.m.) 5156 kg. of 10-12mm machine crushed stone jelly and with about (4.79 cu.m.) 7670 kg. of sand, but excluding cost of reinforcement grill and fabricating charges, centering and shuttering and also including laying, vibrating with mechanical vibrators, finishing, curing, etc. and providing fixtures like fan clamps in the RCC floor/ roof slabs wherever necessary without claiming extra, etc., complete complying with standard specification and as directed by the departmental officers. The coarse and fine aggregates to be used should comply with the requirements of IS Standards. (No separate payment will be made by the Department for the excess usage of materials).
For Foundation and Basement
For Superstructure in Ground Floor
For Superstructure in First Floor
For Superstructure in Second Floor
For Superstructure in Third Floor
For Superstructure in Fourth Floor
For Superstructure in Fifth Floor
For Superstructure in Sixth Floor
For Superstructure in Seventh Floor
Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two M-sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed.
50mm thick slab (using 20mm HBGS jelly)
75mm thick slab (using 20mm HBGS jelly)
Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel grills for all RCC works as per design given including cost of steel and G.I. binding wire in all floors etc. complete complying with standard specification.(Contractor has to make his own arrangements for the supply of steel and binding wire)
Post Tensioning Work: Design and execution of post tensioning work, including decoiling, the strands, cutting to the required lengths, supplying, laying of HT strands sheathing (GI corrugated ducts 0.3mm thick) jointing with couplers and inserting the strands, profiling, fixing live end anchorages, including supply of stressing anchorages, suitable for 5-5 & 5-4 tendons, grout vents, making dead end anchorages, including flowering the strands, fixing tendon support bars, supervising the fixing of antibursting reinforcement, stressing the cables, end trimming, grouting the cables, with cement slurry, mixed with admixtures with required tools, plants, and machineries, and consumables etc. (Shuttering, concreting & reinforcement steel shall be paid under respective items) at all heights including all leads, lifts, coordination, with the post- tensioning agency, preparation of drawings, obtaining approval from the Employer / Architect etc. Rate to include providing water, power, cement and admixture for grouting, packing of sheathing and anchorages blockings, filling of recess pockets after stressing using grouts (cement slurry mixed with approved admixtures) including providing access to post tensioning at all heights including all leads, lifts etc., all complete and as approved and as directed by the Employer Architect but excluding shuttering, concreting & reinforcement steel which shall be payable under respective items separately.
Plain Cement Concrete 1:2:4 (one cement, two M-sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specifications and as directed by the departmental officers.
For Foundation and Basement
For Superstructure in First Floor
For Superstructure in Second Floor
For Superstructure in Fifth Floor
For Superstructure in Seventh Floor
For Superstructure in Eighth Floor
Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers.
For Superstructure in First Floor
For Superstructure in Second Floor
For Superstructure in Third Floor
For Superstructure in Fourth Floor
For Superstructure in Fifth Floor
For Superstructure in Sixth Floor
For Superstructure in Seventh Floor
Paving the Top of roof with Solar refelective ceramic tiles of size 305 x 305 x 7mm thick of approved quality and colour laid in Cement mortar 1:3 (One cement and three M-sand) 12mm thick and pointed with tile grout (Nitotile Grout or equivalent) and cement in the ratio of 1:3 for joint, curing etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by the Executive Engineer before use on works)
Flooring with Self design Jointfree Rectified Glazed Ceramic Tiles of size 305 x 305 x 8mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three M-Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be Johnson / Kajaria / Somany / Nitco / RAK which has to be got approved by Executive Engineer before use on works)
Paving the floor with best quality Double Charged Vitrified Tiles of size 600 x 600 x 8mm of approved colour, shade and quality laid in cement mortar 1:3 (one cement and three M-sand) 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Paving the floor with best approved quality fine polished Kota stone slabs of size above 600 x 600 of 18/20mm with machine cut edges and matching marble slab not less than 100mm width other than Adanga Marbles as border laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three M-sand) fixing the slabs in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments and polishing with floor polisher to a high degree of finish etc., The kota stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard speicification.
Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three M-sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Paving with Rubber Moulded hydraulically pressed cement concrete paver block with pattern design of 50% colour and 50% Plain of 83 mm of approved quality and colour, over the sand filling to full depth of slab perfectly and neat finishing the joints, compressing with vibrator. The rate shall be inclusive of cost of paver block, taxes, incidental charges, transportion charges and labour charges for fixing, neat finishing the joints as directed by the departmental officers etc., complete complying with standard specification. The paver block should got approved by the departmental officers before use on work.
Paving the floor with Tactile Paver Type of New Tek BT Yellow Colour Ceramic Tiles of size 305 x 305 x 15mm for Vision Impairment Person of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three M-Sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg/sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works).
Dadooing walls with best approved quality of Ceramic Tiles of size 300 mm x 450 mm x 8 mm in Cement Mortar 1:2 (One Cement and Two M-sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be Johnson / Kajaria / Somany / Nitco / RAK which has to be got approved by Executive Engineer before use on works)
Dadooing walls with Colour designed digital print Ceramic tiles, with borders, with size of 300mm x 600mm x 10mm and above set in Cement Mortar 1:2 (One Cement and Two M-sand) 10mm thick and pointing the joints with white cement mixed with colouring pigments at the rate of 0.40 Kg. / sq.m. neatly in all floors, curing, etc., complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be Johnson / Kajaria / Somany / Nitco / RAK which has to be got approved by Executive Engineer before use on works)
Providing granolithic floor finish of the following thickness with plain cement concrete 1:2:4 (One Cement, Two M-sand and Four aggregate) using 10 to 12mm gauge hard broken stone jelly including laying, finishing and the top rubbed smooth with power trawl, thread lining, curing etc. complete complying with standard specification and as directed by the departmental officers. (The rate is inclusive of necessary planking for panelling wherever necessary and as directed by the departmental officers)
For 40mm thick
Supplying and fixing fine polished cuddapah slab of 38 / 40mm thickness for cup-board arrangements including laying to correct alignment with necessary cement mortar and black powder etc, complete complying with standard specification and as direct.
Providing Leather finished granite slab Jet Black of similar varieties of approved colour for Staircase Treads and midlanding including nosing free from all defts in all floors over a base layer of cement mortar 1:3 (one cement and three msand) 10 to 20mm thick in all floors and the top pointed with the white cement mixed same colour pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works)
Paving the floor with best approved quality fine polished Granite Stone Slabs of size 1200 x 600 of 18 / 20mm thick of Synthetic Grey, Paradise and similar varieties with machine cut edges laid over a cement mortar bed of 20mm thick using cement mortar 1:3 (One cement and three M-sand) fixing the slabs with required cement slurry and laid in true right angles with minimum possible width of joints and pointing the joints with white cement mixed with mathcing colouring pigments etc., The granite stone slabs and other materials to be used shall be got approved by the Executive Engineer concerned before use on work, etc., complete as per standard specification.
Providing Nosing the granite slabs by cutting the granite slabs for size 1200 x 600 x 18mm to 20mm thick edges semicircular shape to required size and nosing with semicircular shape and polishing using hand machine and the nosing is made highly smooth and gloosy the cost includes labour charged and cost of machineries and polishing charges etc., complete.
Supplying and Fixing marble slab for Urinal partition of 18/20 mm thick with top and bottom edges sharped to curve and fixing with cement mortar 1:2 (One cement and Two M.sand) including dismantling the existing wall and fixing the slab in position including cement slurry etc., complete complying with standard specifications.
Plastering with Cement Mortar 1:5 (One cement and Five M-sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three M-Sand) 10mm thick including hacking the surfaces, providing cement mortar nosing, beading for sunshades, staircases, steps, landing slabs and curing, etc., in all floors complying with standard specification and as directed by the departmental officers.
Plastering with Cement Mortar 1:3 (One Cement and Three M-Sand) 12mm thick mixed with water proofing compound conforming to BIS at 2% by weight of cement used including finsihing, curing, etc., complete in all floors complying with standard specification and as directed by the departmental officers.
Plastering the surface of walls with Cement Mortar 1:3 (One cement and Three M-sand), 20mm thick in all floors including curing etc., complete complying with standard specification and as directed by the departmental officers.
Plastering with Cement Mortar 1:5 (One cement and Five M-sand), 20mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers.
Providing Polymer Coating (Water Proof Coating) for sunken Portion of toilet with following specification and the surface shall be cleaned to remove all dust, foreign, matters lose materials or any other deposits of contamination by rubbing with wire brush. Slurry: Dry blend and polymer liquid blend shall be mixed into the desired ratio as per recommendation of the supplier. The mix shall be stirred throughly until no bubbles remain in the mix. Any lumps found in mix shall be removed. Apply first coat of polymer modified cementitious slurry by brush on wet cleaned surface. After drying, second coat shall be applied on the first coat as directed by the departmental officers etc. The rate inclusive of cost of materials and labour, etc., complete.
Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg/sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of "U" clamp at the centre of the pipe line in addition to those for more than 3 metre pipe length, etc., complete complying with standard specification.
160mm dia PVC Pipe (Eight Floors )
110mm dia PVC Pipe (Single Floor )
110mm dia PVC Pipe (Three Floors )
Supplying and applying of two coats of putty of 3mm thick over the exposed RCC surface of ceiling including finishing the joints smoothly with grinding machine and the surface shall be thoroughly cleaned out of dust and scrubbing. The surface shall then be allowed to dry for atleast 48 hours. It shall then be sand papered (water proof abrasive sheet) to give a smooth and even surface. Any unevenness shall be made good by applying 1st coat of putty mixed with water on the entire surface including filling up the undulations and applying 2nd coat of putty after 6 hours of 1st coat of putty and then sand papering (water proof abrasive sheet) the same after it is dry and finishing the surface smoothly, etc., complete complying with standard specifications and as directed by the Departmental Officers. (The rates are inclusive of hire charges for grinding machine with wheel,cost of sand paper (water proof abrasive sheet), coat of putty blade, labour charges for grinding the joints and sand papering,two coats of putty,scrapping the putty area to level the surface smooth,etc., complete.The putty should be got approved by the Executive Engineer before use on work.
Supplying and applying wall Putty with two coats of plastered wall surface of first class quality and of approved including thorough scrapping, clean removal of dirt wherever required etc., complete complying with standard specification.
Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc., as per standard specification. (The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work).
Painting Two coats of newly plastered wall surface with ready mixed Plastic Interior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting two coats of newly plastered wall surface with ready mixed Exterior emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
Supplying and fixing following Ornamental Burma Teakwood entrance door as per the drawings and designs approved by the departmental officers .The size of the opening is 3.00x3.00m. The outer frame of the door is 150mmx125mm teakwood. The main door shutter opening size is 3.00mx3.00m.The main door should be double leaves and each door shutter fully panelled.The door shutter outer frame of size 150mmx50mm teakwood. The door panells shall be of 50mm thick teakwood planks with ornamental designs approved by the Executive Engineer. The Lock rail shall be of 200x50mm tk teakwood. The top of the door to a height of 900mm finished with fixed glazing of approved pattern using 12mm thick toughened glass with MS grill. the sides of the door shall be fixed glazing of size 900mmx3900mm finished with 12mm thick toughened designed glass. All the door frames and fixed glazing frames are made out of 150mmx125mm teakwood of best quality. The door frames and shutters shall be given two coats of best approved quality melamine finish. The rate inclusive of cost of approved quality teakwood, 12mm thick designed toughened glass, brass hinges, brass tower bolts, brass aldrops, door stoppers, brass screws etc.,The cost includes cost of material, labour charges, conveyance charges, fixing charges,designing charges and glass design charges, electricity charges and all other incidental charges., etc. All materials should be got approved by the Executive Engineer before use on works.
Supplying and fixing inposition Stainless Steel (Salem Stainless Steel) Door Frame (Box Section using Stainless Steel Plate of 1.6mm thick) of size 100mm x 60mm with a rebate of 30 / 35mm x 15mm on one side of the frame including supplying and fixing dovetail splayed end stainless steel hold fast etc., etc.The door frame inner shall be packed with CC 1:2:4 using 12mm gauge HBG stone jelly including fixing the door frames inposition and dismantling the masonry and concrete wherever necessary and redoing the same original condition after fixing including scaffolding charges and labour charges and door frame will be given one coat of Red Oxide primer etc. Complete complying with standard specification The rate shall inclusive of all materials, labour, transportation, loading, unloading, handling, charges etc. The sample of materials should be got approved by the Excutive Engineer before use on works.
FRAME: Fully Solid core WPC – 75MM x 50MM: Providing & Fixing of Qute WPC / PVC solid door frame extruded with size 75mm x 50mm. The inner core made of rigid WPC compound with minimum shore hardness of 55, and Bulk Density 0.8 Grms/ Cub.C.Mt. The frame shall be fixed to the wall using 10 x 100mm long M.S Screw through the frame by using PVC fasteners. A minimum of 4nos screws to be provided for each vertical member.
SHUTTER: Solid Single Core WPC Door - 25mm thick: Providing & Fixing of 25mm thick QUTE WPC / PVC single core Extruded door shutter (confirming As per IS : 4020), with one layer on either sides of the door surface. The Solid board shall have minimum shore hardness of 55 and Bulk Density 0.65 Grms/ Cub.C.Mt. With the 3 layers mounting the thickness shall be minimum 25mm (+/- 1mm). The door shall be Lead freeand it must be manufactured by an ISO: 9001 : 2015 certified company. The door should be guaranteed Water Proof , Termite Proof , Fire Retardant and having high screw holding capacity.
Supplying and fixing 30mm thick solid core PVC door shutter with PVC frame of size 50x45mm with suitable rebate for housing the shutter (Conforming to IS 4020 with updated amendment) consisting of frame made out of MS tubes 19 gauge thickness and size of 19 x 19mm for styles and 15x15mm for top and bottom rails. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C' channel of size 30 x 50mm forming styles, and 75x50mm for top rail, lock rail and bottom rail on either side and 10mm (5mm x 2) thick 20mm wide cross PVC sheet as gap insert for top rail, bottom rail. Paneling of 5mm thick PVC sheet bearing on either side and join together other side etc. An additional 5mm thick PVC strip of 20mm width is to be stack and the interior side of the ‘C' channel using PVC sealant adhesive including cost of all furniture fittings such as aluminium aldrop of size 250x16mm - 1No., aluminium tower bolt 250x12mm - 1No. aluminium D type handle 200mm etc. complete, as per direction of Engineer in charge and drawing. (Sliding arrangements with roller)
Manufacturing, supplying and fixing of Steel doors with following specification. MS angle of size 40x40x6mm at 3.5 kg/m used for outer frame and MS Angle of size 35x35x5mm at 2.6 Kg/m for the shutter frame. Stiffeners with 32x6mm at 1.5 Kg/m MS Flat is provided as the lock rail of the door and welded intact on both ends to the shutter frame. 18 G CR Sheets of best quality is laid as panel in the shutter frames. 18x5mm at 0.70 kg/m MS flat is welded over the 32x6mm at 1.50kg/m MS Flat on the rear side of the door, sandwitching the CR Sheet for rigidity. Additional stiffeners with 18x5mm at 0.7 Kg/m MS flats are provided diagonally on the rear side of the shutter. 300mm length of hinges 2 Nos, for shutter is provided. 6 Nos. of 250mm length hold fasts 200mm length specified at the ends are welded to the outer frame of the door. Tower bolt 2 Nos. at the top provided. 250x16mm size of Two aldrops are provided in single leaf door at lock rail section in the door for inner and outer provided and one rotating locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place and 1 No. of M.S. handle of heavy duty. A tie bar is provided at the bottom of the outer frame to prevent twisting of the frame during transportation and fixing. All members are given one coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation, taxes and all other incidental charges, etc., complete.
Single Leaf
Manufacturing, Supplying and fixing in position of steel windows with the following specifications. Outer frames of windows made of 'Z' section F7D of size 33 x 25 x 3mm at 1.419 Kg/m and mullion 'J' section (F4B) of size 46x25 x 3mm at 2.28 kg/m and shutter section of made of F7D of 33 x 25 x 3mm at 1.419 Kg/m as specified in IS 7452/1990. Each openable shutter should not exceed a width of 600mm to enable separate operations and easy maintenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18x5mm MS flat at 0.70 Kg/m at 3 Nos. for each shutter and additional diagonal stiffeners of the same MS Flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR sheets in position firmly. 4 numbers of sturdy hinges and Two number of handle-cum-latch of special type made with 18x5mm MS Flats are revetted to the shutters at an appropriate height in window. Suitable opening is left for its easy operation. A stopper square rod for handle is provided in the mullion section at suitable place to catch the window handle. Each window shutter having an adjustable stay made out of 18x5mm at 0.70 kg/m MS flat of length 320mm with three adjustable position. A matching peg is provided in the outer frame of the window at suitable place. 4 Nos. of hold fasts of 120mm length spliced at the nds are welded to the out frame of the window by using MS flat of 18x5 mm at 0.70 kg/m, welded to the shutter at two place equivalent from each other from top and bottom of the shutter. An MS square bar of 12mm size is welded to the inner face of the window at an equal interval not exceeding 100mm edge to edge between them. All members are painted with one cat of anti-corrosive red oxide primer as directed by the departmental officers. All sections should be in confirmed with IS7452/1990. The cost includes cost of all materials, labour charges and other incidental charges, etc., complete.
Two Leaves
Supplying and fixing of solid core flush shutters of exterior grade, both side pre lamiated 35mm thick conforming to I.S.12406\1989 with 35x12mm T.W. lipping on all edges with necessary adhesive and C.P.Screws complying with std specifications, including fixing of aldrops, tower bolts, hinges and lock strike plates, putty, fevical, varnish, for T.W. lipping thinner colouring agent etc, and aluminium anodised 125mm size hinges 3 nos best quality of aluminium anodised fittings of 200 mm, tower bolt 1 no 250mm tower bolts 1 nos, 250mm aldrops 16mm dia rod 1 no 200mm long handle 2 nos 60mm dia nylon bush 1no, door stoper 1 No shall be provided. The rate is inclusive cost of fevical and fixing charges, transportation, loading, unloading and all other incidental charges handling charges etc., complete complying with standard specification. The sample of materials and fittings should be got approved by the Engineer-in-charge before use on works.
Single Leaf
Supplying and fixing of solid core flush shutters of exterior grade, both side pre lamiated 35mm thick conforming to I.S.12406\1989 with 35x12mm T.W. lipping on all edges with necessary adhesive and C.P.Screws complying with std specifications, including fixing of aldrops, tower bolts, hinges and lock strike plates, putty, fevical, varnish, for T.W. lipping thinner colouring agent etc, and aluminium anodised 125mm size hinges 3 nos best quality of aluminium anodised fittings of 200 mm, tower bolt 1 no 250mm tower bolts 1 nos, 250mm aldrops 16mm dia rod 1 no 200mm long handle 2 nos 60mm dia nylon bush 1no, door stoper 1 No shall be provided. The rate is inclusive cost of fevical and fixing charges, transportation, loading, unloading and all other incidental charges handling charges etc., complete complying with standard specification. The sample of materials and fittings should be got approved by the Engineer-in-charge before use on works.
Double Leaves
Providing Strong Room Door for Sub Treasuries etc., complete as directed by the departmental officers.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work.
Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work.
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete complying with Standard Specification.
Manufacturing Supplying and fixing of stainless Steel Hand rails for staircase near wet raiser using 50mm dia 304L Grade Stainless steel pipe of 1.60m thick will be provided with tubular supports made of 304L Grade Stainless Steel pipe of 25mm dia 1.60m thick welded to the railing. The supports will be grouted into the wall and provided with 93.00mm thick Stailess Steel circular base plate of 304 Grade. The rate is inclued for grouting into concrete with necessary supporting arrangements the hand rail in floor polishing buffing, bonding, cutting, grinding, conveyance, eletrical charges,ect, complete complying with standard specification.
Supplying and fixing of M.S.grill of approved design for grill gate, grill work to doors and windows openings ramp etc., using necessary mild steel flats for inner and outer members which should be fixed on edges including priming coat of best approved quality red oxide primer etc., complete complying with standard specification.
Supplying and fixing of rolling shutters shall be pull and push type made of 18/Gx3" lath sections which consist of five main parts such as curtain, lock plate, guide channels rollers and hood cover. These five main parts are made out of special components detailed below:Curtain shall be of 18/Gx3" lath sections cut to required size and filled with heavy cast iron / MS clips. For 8' 0" (2.45m) high rolling shutter lath sections provided shall be not less than 37 numbers. Lock plate shall be of 10 GMS sheet reinforced with 40mm x 6mm MS angles at the bottom and fitted with heavy latches and locking arrangements on either sides. There should be one handle on either sides. Guide channel pressed guide channels shall be 10GMS sheet and attached to the side brackets with 20mm square bar. Side brackets shall be of 10G MS plate and cast iron "U" clamps shall be rivetted to the side brackets. Roller shall be of heavy cast iron pullies fitted with heavy duty "C" class 40mm steel pipe and high tensile high carbon coil springs. 2 springs shall be supplied. Side brackets shall be of 10G MS plate and cast iron "U" clamps shall be rivetted to the side brackets. Roller shall be of heavy cast iron pullies fitted with heavy duty "C" class 40mm steel pipe and high tensile high carbon coil springs - 2 springs shall be supplied. Hood cover shall be of 0.8mm CRCA sheet reinforced with 25mm x 25mm x 3 mm MS angle or gate channel. The rolling shutter in addition to the above should have pulling hook and shall be coated on exposed area with heavy coat of red oxide primer.
Manually Operated
Providing suspended GYP Board False Ceiling of the following types with G.I. perimeter channel of size 0.55mm tk (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimetre of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws at 610mm centres. Then suspending G.I. Intermediate channel of size 45mm (0.90mm thick with two flanges of 15mm each) from the soffit at 1220mm centres with ceiling angle of 25mmx 10mmx0.50mm thick fixed to soffit with G.I. Cleat and steel expansion fastners ceiling section of 0.50mm thickness having knurled web of 51.50mm and two flanges of 26mm each with lips of 10.50mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm centres. 12.50mm tapered edge Gyp board (confirming to IS 2095-1982) is then screw fixed to ceiling section with 25mm dry wall screws at 230mm centres. Screw fixing should bedone mechanically either with screw driver or with drilling machine with suitable attachment.
Providing Cornice Work for Gyp Board False Ceiling as directed by the Departmental Officers. The design pattern, water proof plywood, OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete.
Providing Wall Panelling using one side teak wood sheet with melamine polishing with following specification. The frame using aluminium tubular section of size 50mm x 25mm x 2mm thick fixing horizontally and vertically in position with wall at interval of 0.60m in both diretions, fixing water proof plywood of 12mm thick over the aluminium frame work with necessary screws. One side teak wood sheet of 3.5mm thick will be fixed over the plywood using fevical and finishing with melamine polishing and the rate inclusive of conveyance to site and labour charges and as directed by the Departmental Officers. The design pattern, water proof plywood, OST sheet and other materials to be used shall be got approved by the Executive Engineer concerned before use on work etc., complete.
Providing Cup-board Shutter using termite / water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work.
Supplying and fixing of fully Calcium Silicate HILUX Board Partition using alu. Box section and aluminium frame at an interval of 0.75m at the aluminium frame of size 63.50mm x38.10mm x 1.28mm, 1.41mm @ 0.818Kg/m with necessary 'L' Angles, screws, nails and fixed in the wall using drilling machine with neat straight alignments etc., after finishing the frame work and fixed with both side 8mm thick HILUX BOARD approved quality and ISI make with necessary screws nails, fevicol and necessary grooves as per instruction of the departmental officers and also cutting the partition for Electrical Switch box and AC Plug Box and telephone Box requirements and finally cleaning the wooden partition for both side with neat position etc., The partition both side should be finished with best wall putty and painting two coats of plastice emulsion paint over one coat of primer including preparation of surface etc. The rate is inclusive of cost of materials,labour charges aluminium frame work and partition work, transporting charges etc., complete as directed by the departmental officers. (The materials quality and colours are approved by the departmental Engineer before use of works)
Structural Glazing: Providing and fixing structural glazing fabricated from roll formed sections made of galvanized steel colour coated (Base steel as per IS 513 of ‘D’ quality, galvanized as per IS 277 with Zinc of 120 grams / sqm.) with total coated thickness of 0.72mm. The glass holding section made of 304 grade SS of 0.6mm thick. Galvanized steel sections are to be used as stiffeners inside the colour coated steel / powder coated sections as per the design requirement. Design calculations are made to suit wind pressures as given in IS 875. Paint specifications: Primer coat with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick. Dimensions: The section should be of 37 x 53mm for frame vertical, 37 x 53mm for frame horizontal section and section for reinforcement should be of 31 x 55mm. glass holding section should be of 37 x 37mm for top and bottom grids in between should be of 37 x 18mm Accessories: Brackets made of CRCA powder coated / electro plated should be used to fix vertical at top and bottom and vertical to slab as per site requirement. Polyurethane brackets should be used to connect horizontal section to vertical sections. Silicone: Natural cure, with good UV resistance to be used. The above frame should be fixed to brick / concrete masonry by using nylon self–expanding cap and driving MS electro plated 80mm long screws into the caps through frames. Glass: 5mm reflective Saint Gobain OR equivalent.
Providing and fixing of Aluminium Composite Panel (ACP) 4 sided having 50 x 25 x 1.50mm frame work vertical and horizontals out of specially designed extruded sections withstand wind pressure of 180 Kg/sq.m and fabricated fixed at all level elevation and heights. The extruded section cutting and fixing required space extruded section shall be of 6063 and alloy of BSH 9 confirming T is – 63400 rate shall included to fix the main frame with necessary clamps, fasteners, bolt nuts etc. The main frame of extruded section shall be of 22843 & 22739 (H9) grade conforming to BS 4174 (or) IS 8147. Rate shall included 4mm thick ACP sheet (0.25 + 3.5 + 0.25) alstrong or equivalent fixing with spacer tape and the ACP sheet bounded with special type structural sealant of dow corning 789 or equivalent in dust free conditions the gaps between ACP sheet to be filed with whether sealant and backer rod or 12mm foam sheet to ensure water and air tightness in all complete complying with standard specification as directed by the departmental officer.
Supplying, laying and jointing UPVC pipes of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. (Above Ground Level) (External Water Supply)
50 mm dia UPVC Pipe
40 mm dia UPVC Pipe
32 mm dia UPVC Pipe
25 mm dia UPVC Pipe
Supplying, laying and jointing UPVC pipes of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. (Above Ground Level) (Internal Water Supply)
25 mm dia UPVC Pipe
20 mm dia UPVC Pipe
Supplying, laying and jointing UPVC pipes of approved quality and best variety conforming to BIS of the following dia including cutting, threading and fixing PVC specials using UPVC adhesives (but excluding cost of such specials) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. (Below Ground Level) (External Water Supply)
40 mm dia UPVC Pipe
32 mm dia UPVC Pipe
Supplying and fixing the following UPVC specials of heavy type of approved quality and good variety of various sizes excluding fixing charges, but including cutting and threading of pipes painting two coats with good variety and approved quality synthetic enamel paint over one coat of priming coat for the GI specials in case of pipeline above ground level and one coat of tar in case of pipe line below ground level for both internal and external water supply arrangements as directed by the departmental officers etc., complete complying with standard specification. UPVC specials should be got approved by the departmental officers before use on work.
50mm dia UPVC Elbow
40mm dia UPVC Elbow
32mm dia UPVC Elbow
25mm dia UPVC Elbow
20mm dia UPVC Elbow
50mm dia UPVC Tee
40mm dia UPVC Tee
32mm dia UPVC Tee
25mm dia UPVC Tee
20mm dia UPVC Tee
50mm dia UPVC Union
40mm dia UPVC Union
32mm dia UPVC Union
25mm dia UPVC Union
50 x 40 mm dia UPVC Reducer
40 x 32 mm dia UPVC Reducer
32 x 25 mm dia UPVC Reducer
25 x 20 mm dia UPVC Reducer
20 x 15 mm dia UPVC Reducer
50 x 40 mm dia UPVC Reducer Elbow
40 x 32 mm dia UPVC Reducer Elbow
32 x 25 mm dia UPVC Reducer Elbow
25 x 20 mm dia UPVC Reducer Elbow
20 x 15 mm dia UPVC Reducer Elbow
50mm dia UPVC Hex Nipple
40mm dia UPVC Hex Nipple
32mm dia UPVC Hex Nipple
25mm dia UPVC Hex Nipple
Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work.
50mm dia Gun Metal Gate Valve
40mm dia Gun Metal Wheel Valve
32mm dia Gun Metal Wheel Valve
25mm dia Gun Metal Wheel Valve
20mm dia Gun Metal Wheel Valve
Supplying and fixing in position 15mm dia brass CP screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
Supplying and filling of 40mm ISS metal in dispersion trench around the stoneware pipe or in the leach pit or soak pit to the required thickness as directed by the departmental officers etc. complete. (The rate including cost of metal filling etc., complete complying with standard specification).
Supplying and filling of 20mm ISS metal in dispersion trench around the stoneware pipe or in the leach pit or soak pit to the required thickness as directed by the departmental officers etc. complete. (The rate including cost of metal filling etc., complete complying with standard specification).
Supplying and fixing PVC ventilating shaft of 110mm dia (having working pressure 4 kg. / sq.cm) with 3 metre height including cost of PVC cylindrical cowl of best approved quality etc., complete complying with standard specifications and as directed by the departmental officers.
Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level.
160mm dia PVC soil / waste pipe
110mm dia PVC soil / waste pipe
75mm dia PVC soil / waste pipe
50mm dia PVC soil / waste pipe
Supplying and fixing in position PVC specials of the following dia and types of approved quality confirming to BIS and providing leak proof joints including fixing to the walls and giving connection to the PVC soil stacks, dismantling the masonry or RCC works and re-doing the dismantled portion to original condition etc., complete complying with standard specifications. (The PVC specials should be got approved by the Executive Engineer before use on works).
160mm dia PVC Elbow
110mm dia PVC Elbow
75mm dia PVC Elbow
50mm dia PVC Elbow
160mm dia PVC Tee
110mm dia PVC Tee
75mm dia PVC Tee
50mm dia PVC Tee
160mm dia PVC Bend
110mm dia PVC Bend
75mm dia PVC Bend
50mm dia PVC Bend
160mm dia PVC Tee with Single Door
110mm dia PVC Tee with Single Door
75mm dia PVC Tee with Single Door
Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with "P" or "S" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two M-sand and Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works)
Supplying and fixing in position white / colour glazed European Water Closet of best quality and approved make with 100 mm "P" or "S" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works) (Special Wall Mount)
Supply and fixing in position of best Indian make white glazed earthernware lipped mouth flat back urinal of best quality and approved make of size 430mm x 260mm x 350mm with GI pipe, 32mm dia bell mouth PVC connection and waste pipe, 15mm dia GI pipe of required length, 15mm dia GM wheel valve, 15mm dia brass nipple 2 Nos., and fixing the urinals in position with necessary TW plugs, clamps, screws, etc., including dismantling masnory and re-doing the same to the original condition, etc., including painting the pipe with two coats of best quality approved synthetic enamel paint over one coat of red oxide primer and checked without any leakage etc. complete complying with standard specifications and as directed by the departmental officers. (The urinal should be got approved by the Executive Engineer before use on works.)
Supplying and fixing in position best approved quality PVC Nahini trap of 100 mm x 75 mm size with PVC grating of approved quality fixed over a bed of brick jelly lime concrete.1:2:5 (one lime two M-sand and five brick jelly) using 40mm broken brick jelly including dismantling the flooring concrete / Brick masonry wherever necessary and redoing the disturbed portion to the original condition and giving connection to the PVC soil (stacks) pipe as directed etc., complete complying with standard specifications. (The PVC Nahini trap should be got approved from the Executive Engineer before use on works).
Supplying and fixing in position on best quality approved make SS sink of size 600x600x200mm including cost of 32mm dia CP waste, coupling 32mm dia PVC waste pipe with rubber plug and chain, 15mm dia brass nipple including fixing the sink in position and testing for leakage etc., complete complying with standard specifications. Excluding CI brackets. (The sink and specials should be got approved by the Executive Engineer before use on works)
Supplying and fixing in position best quality and approved make Indian made white glazed earthernware wash hand basin of size 550 x 400mm without pedestal with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia "B" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
Supply and fixing in position of best CP Wall Mixture tap 3 in 1 system with Hand Showers with approved make and quality with approved brand (Jaguar, Parryware, ESS, Kohler, cera or equivalent) the cost including labour charges for fixing, fittings etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works).
Supplying and fixing in position best approved quality CP Shower Arm with Overhead Shower Rose., complete complying with standard specification and as directed by the departmental officers.
Supplying and fixing in position Indian make bevelled edge mirror of approved quality and brand PVC / Fibre Glass framed 600 x 450 x 5.5mm thick mirror, shelf type with hard board backing of approved colour fixed with brass screws, rawl plug, etc., complete complying with standard specification. (The mirror should be got approved by the Executive Engineer before use on woks).
Supplying and fixing best approved best quality brass CP soap tray of size 150 x 150mm including cost of teak wood plugs, brass screws, etc., complete complying with standard specifications. (The soap tray should be got approved by Executive Engineer before use on works).
Supplying and fixing approved best quality brass CP towel rail 600mm long and 20mm dia with brackets of same materials including cost of teak wood plugs and CP screws, etc., complete complying with standard specifications. (The tower rail should be got approved by Executive Engineer before use on works).
Supplying and fixing in position of heavy type SFRC manhole cover of size 60x60cm including making necessery raised portion with brick work in cement mortar 1:5 (one cement and five M-sand) and plastering with cement mortar 1:5 (one cement and five M-sand) to accommodate the manhole cover frame and neatly finishing etc complete complying with standard specification.
Drilling of 150mm dia vertical bores in hard rock areas to any required depth as directed by the Departmental Officers including Labour charges for inserting casing pipes assembling in the drilled including welding the joints wherever necessary and grouting the casing pipe, and developing the bore etc., the rate shall inclusive of transportations charges for the rig and supporting vehicle from one place to another excluding cost of casing pipe etc., complete as directed by the Executive Engineer. (Upto 150m Below Ground Level)
Supply of 160 mm PVC Special Blue casing pipe of best approved quality etc complete as directed by the departmental officers. The pipe should got approved by the Executive Engineer before use on works.
Supplying and fixing of PVC end cap of 160mm dia at the end of P.V.C casing pipe etc., complete complying with standard specification. The bore cap should be got approved by the Engineer Incharge before us on works.
Supplying and fixing erecting 7.5 HP ( DECCAN MAKE) ISI make bore well SUBMERSIBLE PUMPSET with required accessories for the 7.5HP ISI make 3 phase electric motor 2900 rpm , 400/S.S. shaft cable of discharging 100 to 200 LPM against a total Head of 135m to 100m with ISI mark and an outlet of 50mm and suitable for 150mm dia bore well including supplying and fixing M.S. fabricated wall mounting Pannel board with internal wiring as per I.E. rules and necessary locking arrangements with suitable cutler and hammer type bush button automatic 10 HP texvel DOL starter - 1 no, suitable 15 Amp, TPIC switch, 0 to 500 v Voltmeter, 0 to 20 Amps Ammeter, single phase preventer. pilot lamps with 3 bulps to indicate power supply and 50mm dia GI coupling - 2 nos, M.S.clamps - 2 nos, 2.5 Sq.mm wire 3 core copper flat submergible cable, including Conveyance and Erection charges including required G. I. Specials, MR Tape Electrical connection charges., delivery pipe connection charges and other plumbing works including hire charges for Chain pully, tripod and other tools and trial run for three days etc., including labour charges complete complying as directed by the departmental officers.
Supplying & fixing of 5.0 H.P Borewell compressor with 5.00 HP motor with heavy duty double cylinder air lifting compressior with stand pulli guard with 2hp 1440 Rpm 220V,50 Hz , 220V ,single phase ,TEFC heavy duty motor complete set with Vee belt& Foot valve ,Pump size water pipe 1 " and air pipe 1/2" etc., complete
Supply and fixing of water proof 2 core 2.5 sq.mm flat P.V.C insulated copper cable for submersible pumpset in the borewell including fixing and fying with copper wire and clamping water pipe etc., complete as directed by the departmental officers.
Supplying and fixing 20mm dia HDPE pipe for sub-mergible pump in Bore well (class-5 1 MPa or 10 Kg / cm2 pressure) of best approved quality including welding wherever necessary etc., complete as directed by the Executive Engineer. The pipe should be got approved by the Executive Engineer before use on works.
Supplying and fixing 32mm dia HDPE pipe for sub-mergible pump in Bore well (class-5 1 MPa or 10 Kg / cm2 pressure) of best approved quality including welding wherever necessary etc., complete as directed by the Executive Engineer. The pipe should be got approved by the Executive Engineer before use on works.
Supplying, fixing of cylindrical vertical notational polythene water storage tank of 2000 litres capacity confirming to I S. 12701 / 96. the tank is meant for outer (or) indoor, use complete with removable hinged top locking arrangements and to make provision to fix with simply pipe lines necessary manhole with cover and including all PVC specials, plugs, screws, nails to fix the tank etc., and the tank should be fixed firmly as directed. The rate shall inclusive of all materials labour, conveyance, hoistings and fixing charges etc., (The water tank should be got approved by the Executive Engineer before use on works by the deptartmental Officers.
Supplying and erecting in position of 2000 liters capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings. The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact.
Supplying and Fixing of Brass Dye Cast Letters of following size to suit the Architectural elevation drawings given for the including cost, conveyance and all other materials and labours involved etc., complete and as directed by the departmental officers.
Brass Dye Cast Letters 37cm (15”) Size
Brass Dye Cast Letters 25cm (10”) Size
Emblem (15”)
Supplying and Fixing of Stainless Steel engraved name plate of size 18"x4" etc., complete and as directed by the departmental officers.
Supplying and fixing of Acrylic name plate 3mm thick with Vinyl printing including embossing the letters of all fonts and sizes etc., complete and as directed by the departmental officers.
Providing expansion joint in RCC floor slab for 12.5mm width using polysulphide as sealent on the top and bottom for a depth of 7.5mm each and packing the inner space using compressible non-absorbent filler materials including cost of labour for cutting and fixing filler materials and laying polysulphide sealent with necessary spatula etc., complete complying with standard specifications and as directed by the departmental officers.
Providing expansion joint 12.5mm width in RCC roof slabs between RCC twin beams using PVC water bar of 150mm wide centre bulb of 4mm to 6mm thickness of approved quality and brand and including filling the inner space with suitable non-absorbent flexible and well compressible filler materials of approved quality and covering the top surface with GI sheet 30cm wide and 1.6mm thick using phill plugs, GI screws, limpet cup washers, bitumen washers, etc., complete complying with standard specifications and as directed by the departmental officers.
Providing expansion joint of 12.5mm wide in between RCC twin columns from top of pedastal to full height including filling the inner space with suitable non-absorbent, flexible and well compressible filler materials of approved quality and brand; finishing the sides of RCC columns with polysulphide sealents for a depth of 7.5mm on either side covering the inner space filled with filler materials as above etc., complete complying with standard specifications and as directed by the Departmental officers.
Supplying and fixing RCC hume Pipe 300 mm dia for cross drain with necessary accessories etc., complete complying with standard specification.
Supplying and fixing sanitary napkin destroyer of approved quality of standard size is 310mm x 310mm and the height of 640mm for over all of the machine weight is approximate 25kgs each Nos, with capacity of 10 to 15 napkin at a time for operating of machine is of duel chamber [primary and secondary and the burring chamber is of SS 304 and this sanitary napkin is certified by the NABL Laboratories and it is machine is operated with electrical for 230 v+ / - 10%, 50Hg single phare 5 A, 1.25 KW this sanitary napkin destroyer machine is destroyer is engineered to reduce used sanitary napkins to sterile as in a matter of seconds, it is extremely easy to use and operate wall mountable free standing] etc, the rate is inclusive of cost of materials such as rigid pipe with complete accessories and labour charges and transporting charges scaffolding charges etc complete as directed by the departmental officer [ the quality of machine is approved by the EE before installed.
Providing and laying Granular sub Base Course by providing close graded material, mixing in a mechanical mix plant at OMC, carriage of mixed metrial to work site, preading in uniform layer with motor grader on prepare the surface and compacting with vibartory power roller to achive the desire density, complete as per class 401. (Grading - V Material)
Providing and laying, spreading and compacting graded stone aggregates to Wet Mix Macadam 150mm thick specification including premixing the materials with water at OMC in mechanical mix plant carriage of mixed material by tipper to site laying in uniform layers with pavers in SubBase / Base course on well prepared surface and compacting with vibratory roller to achieve the desired density including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per clause 406 of MORTH Rev-5
Providing and laying Prime Coat over WBM/WMM surface using 7Kg of Emulsion Bitumen (SS1) per 10 sqm for preparatory to another bituminous construction over it, including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per Clause 502 of MORTH Rev-5
Providing and laying Tack Coat over WBM/WMM surface (treated with primer) using 2.50Kg of Bitumen Emulsion (RS1) per 10 sqm for preparatory to another bituminous construction over it including cost of material, labour charges, rentals for machinery, fuel and all other incidental charges etc., complete as per Clause 503 of MORTH Rev-5
Providing and laying of 50mm consolidate thick Bituminous Macadam (CMB Grade II) using 0.20 cum of 26.50 -13.20mm, and 0.43 cum of 13.20-2.36 and 0.08 cum of 2.36mm & below size IRC Matel with 37kgs of VG30/VG40 bitumen for premixing per 10 sqm including cost and conveyance of all materials to CMP site, heating the bitumen and aggregate to required temperature and mixing the min required temperature in central hot mix plant 20-30 ton capacity, conveying the mix by tipper trucks to paver site, spreading the mix to uniform thickness of 50mm with mechanical paver to the specified grade sand cross sections and consolidated by 8-10 tonne Vibratory /Pneumatic Roller to the required density etc., including labour for attending to paver to site etc., including hire charges and fuel charges for 20-30t CMP with bitumen boiler, tipper trucks, Paver Finisher / 9m paver finisher, Vibratory/ Pneumatic roller and all other tools and plant required, including fuel and all other incidental charges etc., complete as per specification using CMP as per clause 507 of MORTH Rev-5
Providing and laying Bituminous Concrete to 40mm thick (CMB Grade II) using 0.13 cum of 19.00-9.50mm, 0.17 cum of 9.50-2.36 mm and 0.26 cum of 2.36 and below with 50.30 kgs of VG30/VG40 bitumen for premixing per 10 sqm including cost and conveyance of all materials to CMP site, heating the bitumen and aggregate to required temperature and mixing the min required temperature in central hot mix plant 20-30 ton capacity, conveying the mix by tipper trucks to paver site, spreading the mix to uniform thickness of 40mm with mechanical paver to the specified grade sand cross sections and consolidated by 8-10 tonne Vibratory /Pneumatic Roller to the required density etc., including labour for attending to paver to site etc., including hire charges and fuel charges for 20-30t CMP with bitumen boiler,tipper trucks, Paver Finisher / 9m paver finisher, Vibratory/ Pneumatic roller and all other tools and plant required, including fuel and all other incidental charges etc., complete as per specification using CMP as per clause 507 of MORTH Rev-5
Providing Ornamental Sthapathy works on the Entrance Arch elevational column of Size 1.20mx1.20m with a height of 5.40m as directed by the departmental officers. The elevation beams shall be given with Ornamental design Sthapathy Kadungais, design projections and kumuthams for a depth of 25cm shall be given on the kabhodha-column junction at bottom. and column-beam junction at top. The Ornamental design Vari Vargam shall be given in between the top and bottom vedhiyais and kumuthams. All the Ornamental works shall be done with Brick work in cement mortar 1:2 ( one cement and two M-sand ) and finished neatly with cement slurry. The rate includes cost of all materials, scafolding charges, finishing, curing and special skilled labours, etc., complete complying with Standard Specification.
Providing Ornamental Sthapathy works on the Entrance Arch elevational column of Size 0.45mx0.45m with a height of 4.80m as directed by the departmental officers. The elevation beams shall be given with Ornamental design Sthapathy Kadungais, design projections and kumuthams for a depth of 25cm shall be given on the kabhodha-column junction at bottom. and column-beam junction at top. The Ornamental design Vari Vargam shall be given in between the top and bottom vedhiyais and kumuthams. All the Ornamental works shall be done with Brick work in cement mortar 1:2 ( one cement and two M-sand ) and finished neatly with cement slurry. The rate includes cost of all materials, scafolding charges, finishing, curing and special skilled labours, etc., complete complying with Standard Specification.
Providing Ornamental sthapathy works on the Entrance Arch elevational slab on three sides as directed by the departmental officiers. The elevational slab shall be given with Ornamental design sthapathy Kadungais, design projections and fins. All the Ornamental works shall be done with Brick work in cement mortar 1:2 ( one cement and two M-sand ) and finished neatly with cement slurry. Reinfocement of required sizes shall be given for making the kabathams and kodungais. The rate includes cost of all materials, scaffolding charges, finishing, curing and special skilled labours, etc., complete complying with Standard Specification.
Supply and fixing of Fire fighting application oblique type stainless steel Hydrant Valve of size 63mm dia with oblique type instantaneous coupling with rotating wheel to open and close the valve including MS flange of table “E”, bolts & nuts with washer as per IS 5290 at ring main around the building and wet riser inside the building including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, installation of Fire Fighting Application 180 degree swinging type, hose reel drum with 20mm dia braided thermoplastic hose of 30 metres long, so as to extend to necessary distance by self rolling spindle wheel including necessary 20mm dia ball valve and open and close spray nozzle, warm clip, etc., as per the standard pattern of any reputed make at every floor nearer to hydrant valve, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary., etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, and fixing in position of Fire Fighting Application Hose of 63mm dia of 15 metres length binded by copper wire with 63mm dia stainless steel male and female instantaneous fire fighting special coupling as per IS 901 as directed by the Departmental Officers. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR/ LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, and fixing in position of Fire Fighting Application 63mm dia stainless steel short length Branch Pipe with hexagonal type spray nozzle of 15mm (or) 20mm jet bore. Near every hydrant points including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply of Fire Fighting Application MS Hose Box to keep two number of hoses and 1 No. of branch pipe with nozzle having proper glass window type double door with universe open key, painted inside white and outside Post Office Red. Near every hydrant point including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply and fixing nominal bore quartized bulb type sprinkler bulb 68 Deg C fast response pendent type including GI collar for each sprinkler bulb, mounted in MS pipe line using suitable size MS threaded coupling, thread, shellac etc., as per standard methods and including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: OMEX / KARTAR / LIFE GUARD / SAFE GUARD / EQUIVALENT.
Supply, erection, testing and commissioning of Fire Fighting 4 Way Fire Brigade Inlet with necessary gun metal 63mm dia non return spring shutter arrangements, so that to control one way flow at the time of emergency water supply by fire and rescue service fire engine entry including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. (Make: KIARTAR / OMEX / EQUIVALENT).
Supply, erection, testing and commissioning of following MS ‘C’ Class Heavy Duty Pipe as per IS 1239 to withstand a developing pressure of 10 kg. / sq.cm including necessary fittings like MS flange of table ‘E’, elbows, reducers, gaskets, bolt, nuts with washers & joints as per standard method of arc welding, including one coat metal primer and two coat Post Office Red painting including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: JINDAL / EQUIVALENT.
150mm Dia
110mm Dia
80mm Dia
50mm Dia
40mm Dia
25mm Dia
Wrapping and coating anti-corrosive treatment for 150mm dia under ground MS pipe having one coat of anti-corrosive metal primer, one layer of asphalt tar tape wound over the MS Pipe as per standard methods as per standard specifications and as directed by the Departmental Officers.
Supply, erection, testing and commissioning of Cast iron body and Gun metal or stainless steel internal Non-return valve of 100mm dia size to control one way flow of water to be installed pump room at delivery line and near overhead tank at terrace level near to jockey pump and motor including necessary MS flange of table ‘E’, gaskets, bolts & nuts, etc. as per IS 5312 including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers.
Supply, erection, testing and commissioning of cast iron body and bronze internal non-rising spindle sluice valve of 100mm dia size at required places to control the flow of water including necessary MS flange of table ‘E’, gaskets, bolts & nuts including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: NORMEX / KARTAR / EQUIVALENT.
Supply, erection, testing and commissioning of 150mm dia size of Heavy Duty Foot Valve including all accesories, such as, MS flange of table ‘E’, gaskets, bolts & nuts, etc., installed at end of 150 / 200mm dia suction pipe line at sump including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete and as per standard specification and as directed by the Departmental Officers. Make: NORMEX / KARTAR / EQUIVALENT.
Supply, erection, testing and commissioning of Air Release Valve of 20mm dia, so as to release airlock in 100mm dia MS pipe at top most wet riser, including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: KARTAR / EQUIVALENT.
Supply, installation, testing and commissioning of Conventional Smoke Detector suitably mounted on ceiling with MS juction box / false ceiling using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers. (Make: Apollo / Equivalent)
Supply, installation, testing and commissioning of Manual Call Point (MCP) providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers. (Make: Ravel / Equivalent)
Supply, installation, testing and commissioning of Electronic Hooter / Sounder providing on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers. (Make: Ravel / Equivalent)
Supply, installation, testing and commissioning of Micro Processor based Conventional 12 Zone Fire Alarm Control Panel having the rating of 24 volt DC power supply, consisting 230 / 24 volt SMPS unit, 2 Nos. of 12 volt, 7 AH standby batteries, suitably mounted on wall using fixing accessories like screws, plug, clamps and etc., as per standard methods and as directed by the Departmental Officers.
Supply and fixing of stored pressure ABC (Mono Ammonium Phospate) Powder Type Fire Extinguisher of 6 kg. capacity as per IS:15683 with pressure gauge, discharge hose & control nozzle, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc, complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT.
Supply and fixing of Carbon-di-Oxide Gas Type 2 kg. capacity Fire Extinguisher as per New IS15683, complete with control valve, discharge hose with horn, wall mounting bracket, safety clip etc., including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary etc., complete as per standard specification and as directed by the Departmental Officers. Make: EXCELLENT / SAFETY FIRST / EQUIVALENT
Supply and fixing of Water CO2 Stored Pressure Type 9 litres capacity Fire Extinguisher as per new IS 15683 complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, wall mounting bracket, safety clip, etc., as directed by the Departmental Officers.
Supply, erection, testing and commissioning of Pressure Gauge with 0 to 14 kg. range of reputed make with necessary valve, milling thread MS coupling fixed at delivery pipe line in pump house to read the developing pressure including conveyance, all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: H-GURU / ISI MAKE / EQUIVALENT.
Supply and laying of following sizes of Armoured Aluminium / Copper Cables for electrical motor, control panel, pressure switch, jockey motor etc., all incidental charges, neccessary scaffolding and re-doing the dismantled portions to its original condition wherever found neccessary, etc., complete as per standard specification and as directed by the Departmental Officers. Make: POLYCAB / PARACON / FINOLEX / EQUIVALENT.
3 core 10 sq.mm Armoured Copper Cable
10 core 2.5 sq.mm Armoured Copper Cable
2 core 2.5 sq.mm Armoured Copper Cable
Supply erection testing and commissioning of Electric Motor Driven Fire Pumpset suitable for automatic operation and consisting of following: a. 1 No. horizontal split casing centrifugal type fire pump capable of delivering 4550 LPM against a total head of 110 metres, so as to ensure a minimum pressure of 3.5 kg. per sq.cm at the farthest top most hydrant / outlet with pump casing of cast iron to grade FG 200, IS 210-1978 and parts like impeller, shaft sleeve, bearing ring etc., of non-corrosive metal either like bronze, brass or gun metal and shaft of stainless steel. b. 1 No. squirrel cage induction motor of 175 HP, 415 Volt, 3 phase 50Hz rating, conforming to IS:325-1978 with class "F" insulation, totally enclosed, IP 55 for enclosure fan cooled type conforming to relevant protection clause of IS 4691, synchronous speed of 2900 RPM. c. Common bed plate fabricated with MS channel / cast iron type for assembling the pump and motor flexible coupling between the pump and the motor with coupling guard for protection - 1 No. d. Making cement concrete foundation suitable for the above pumpset including vibration isolation pads as necessary, foundation bolts, brackets, clamp fixtures, grouting, etc., in accordance with the manufacturer's design and as per standard methods and including conveying, fixing and incidental charges, etc., complete as per standard Specification and as directed by the Departmental Officers.
Supply, Installation, Testing and Commissioning of Diesel Engine driven main Fire Pump suitable for automatic operation and consisting of following complete in all respects as required. (a) 1 No Horizontal split casing centrifugal type fire pump capable of delivering 4550 LPM against total head of 110mtrs so as to ensure a minium pressure of 3.50kg per sq.cm at the farthest top most hydrant / Outlet with pump casing of castiron to grade FG 200, IS 210-1978 and parts like lmpeller, shaft sleeve, bearing ring etc., of non corrosive metal either like Bronze, brass or Gun Metal and shaft of Stainless Steel (b) 190 BHP, 1500 RPM water cooled with radiator, disel engine conforming to relevant BS & IS standard complete. (c) Auto starting mechanism, 12 Volts/24Volts electric starting euipment like self Motor, Dyanamo, Solenoid switches, etc., (d) 110 Ltrs capacity Diesel tank mounted over stand fabricated using 25mmx25mmx6mm size MS angle, providing with level indicator, inlet port, outlet port drain port and deisel return line port fuel pre filter, after filter etc., (e) exhaust system having flexible metalic mufler, 100 mm dia MS heavy pipe extended upto 1m outside pump house duly insulated with 50mm thick glass wool with 1mm thick aluminium sheet cladding, residental sliencer with necessary MS support arrangements from wall or ceiling as per site condition. (f) Dash board consisting the insruments like Temperature gauage, Galvano type DC Ammeter, Lub oil pressure gauge, lgnition switch, Emergency stop and all other protection equipement as per specification, stop seleneid for auto stop in the event of fault with audio indicators, paintyed with post office red colour etc as required.
Supply, erection, testing and commissioning of 180 LPM, 70 metres Head Pressurization Pump with 10HP electrical motor of Kirloskar make with suitable base frame including necessary vibration bad mounting etc., including conveying, fixing and incidental charges, etc., complete as per standard specification and as directed by the Departmental Officers. (Make: KIRLOSKAR / EQUIVALENT).
Earthing arrangements with GI Earth Plate including charcoal and salt with necessary excavation in all soils and to full depth as may be required and masonry work, re-filling the sides of foundation with excavated earth as per the standard specification and as directed by the Departmental Officers.
Supply and providing 1000 litres capacity Priming Tank made up of PVC. Make: SINTEX / EQUIVALENT
Supply and laying of FRLS PVC insulated 2 core 1.5 sq.mm. Armoured Copper Cable on ceiling / wall using fixing accessories like screws, plug, clamps, etc., as per standard methods and as directed by the Departmental Officers.
Providing Pre construction Anti termite treatment for the building including all chemicals as per standard specifications. Labour charges for preparing the areas for treatment spraying chemicals and other incidential charges etc., complete. The rate shall be inclusive of giving anti-termite treatment to the building for the following four stages including breaking the termite mounds making holes with crow bars at an intervel of 12"to a depth of 8" in the periphery of building and pouring chemicals etc., complete as per ISI 6313-1981 and. The antitermite chemicals used should have 0.5% concentration with 3L solution for the entire operation etc. as directed by the Engineer incharge and including cost of chemicals labour transportion etc, Stage:1 Spraying Anti-termite treatement chemicals solution for the foundation before laying the foundation concrete bottom and sides of the foundation. Stage:2 Spraying anti-termite chemicals solution to the grade beams level spraying has to be done for the grade beams brick masonry in the superstructure in contact with back fill earth. Stage:3 Spraying anti-termite chemicals solution on sand for the flooring before laying the flooring concrete. The treatment has to be carried out on the sand filling the basement after leveling operation is over. Stage:4 Spraying anti-termite chemicals solution around the building outside of the building by making crow bar holes at an intervel of 12" to a depth of 8" around the building before laying the plinth projection. This holes has to be be closed after the treatment.
Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) ( 4 points / Coil) Higher End (32 +288 GDP)
Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (5 points / Coil) Higher End
Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with PVC accessories with Module GI switch box in flush with wall with 6A one way module switch with module front plate with continuous earth wire connection by 2.5 sq.mm. PVC insulated SC unsheathed copper wire and making good of the concealed portion with suitable colour for Concealed PVC Light point / fan point (for electronic regulator) (6 points / Coil) Higher End
Wiring with 2 x1.5 sq.mm. (22/0.3) PVC insulated single core unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories with suitable Module GI switch box in flush with wall with 1 no. 6A one way module switch and 1 no. 6A 3/2 pin module socket with module front plate with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with painting of suitable colour for concealed PVC pipe Plug point ( 8 points / Coil) Higher End
Supply and fixing of Essential 10W Hexagon bulk Head Back -lit luminaire ( Make Havells / Wipro Crompton) LED bulb for BH point.
Supply and fixing of single box type 4' 18 W LED fitting complete with TW round blocks on wall or ceiling with 18 W LED tube light with Single side connection (Havells / Crompton / Wipro) with PVC unsheathed Copper leads from terminals to the fitting.
Supply and fixing of single box type 4' 18 W LED fitting complete with TW round blocks with conduit pipe suspension from the ceiling with 18 W LED tube light with single side connection (Havells / Crompton / Wipro) with PVC unsheathed Copper leads from terminals to the fitting.
Supply and fixing of Twin box type 4' 22 W LED fitting complete with TW round blocks on wall or ceiling with 2 Nos 18 W LED tube light with Single side connection (Havells / Crompton / Wipro) with PVC unsheathed Copper leads from terminals to the fitting.
Supply and fixing of Aesthetically desined ultra modern 34 W 2' x 2'recessed Mounting luminaire with high brightness LED fitting (Havels model No. Pluto NEO PANEL 2x2 LHEWEJP7PL 1W034 ) ( Havells / Crompton/Wipro ) on wall or ceiling, with PVC unsheathed leads from terminals to the fitting.
Supply and fixing of Aesthetically desined ultra modern 34 W 2' x 2' Surface Mounting luminaire with high brightness LED fitting (Havels model No. Pluto NEO PANEL 2x2 LHEWEJP7PL 1W034 ) ( Havells / Crompton /Wipro ) on wall or ceiling, with PVC unsheathed leads from terminals to the fitting.
Supply and fixing of Aesthetically desined ultra modern 15 W 1' x 1' High efficacy 1x1 recess LED flat panel with high brightness LED for glare-free homogenous illumination. Also for POP ceilings LED fitting (Havels model No. PLUTO1X1PLR15WLED857S) (Havells/Crompton / Wipro ) on wall or ceiling, with PVC unsheathed leads from terminals to the fitting.
Supply and fixing of Aesthetically desined ultra modern 15 W 1' x 1' surface Mounting luminaire with high brightness LED fitting (Havells model No. PLUTO1X1PLR15WLED857S ) (Havells / Crompton / Wipro) on wall or ceiling, with PVC unsheathed leads from terminals to the fitting.
Supply and fixing of High efficacy round type High efficacy suface mounted LED SPOT light 25W LED downlighter with white powder coated aluminium housing with integrated electronic driver (ENDURA HOLDR 25W LED857MOD+ LED DRIVER 25W ENDURA HOCE) (Havells / Crompton / Wipro ) on wall or ceiling, with PVC unsheathed leads from terminals to the fitting.
Supply and fixing of 1200mm (48") sweep AC ceiling fan High speed complete with 2 module 100W fan step regulator (Higher end) with 1 metre down rod on the existing fan clamp.
Supply and fixing of 300mm (12") sweep (light duty) AC exhaust fan complete without provision of hole in the wall.
Supply and fixing of louvers shutters arrangements for 300 mm (12") sweep (light duty) AC exhaust fan.
Supply and fixing of 3nos.6A two module 5 pin socket , 3 nos. 6A one module switch with module cover plate (plastic) on suitable module concealed Box (GI ) in flush with wall with connections. Higher End.
Supply and fixing of 1 no.6/16A two module socket , 1 no. 16A one module switch on suitable module surface mounting Box (GI ) with module cover plate (plastic) on wall with connections. Higher End
Supply and fixing of 20A DP Plug and Socket in sheet steel enclosure with 32A DP MCB in flush with wall with earth connection. DP Plug and Socket with enclosure and the MCB should be of Legrand/Hager make (For AC Plug).
Supply and fixing of 32A DP Isolator in sheet steel enclosure in flush with wall and making good of the concealed portion with earth connection. The DP MCB Enclosure should be of Legrand / Hager make only.
Supply and fixing of 32A FP MCB in sheet steel enclosure in flush with wall and making good of the concealed portion with earth connection The FP MCB Enclosure should be of Legrand / Hager make.
Supply and fixing of 63A FP Isolator in suitable FP sheet enclosure in flush with wall and making good of the concealed portion with earth connection. The MCB Enclosure should be of Legrand (MDS)/Hager (L&T) make.
Supply and fixing of 40 A Rotary switch with 3 Nos Indicator combined with switch insutable sheet steel encloser on wall with earth connection only.
Supply and and fixing of 12 way single pole and neutral MCB Double door type sheet steel enclosure Distribution board with 1 No.40 A ELCB IP 42 protection with 1 No 32A DP MCB as incoming and 10 Nos. 6A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB's should be of Legrand / Hagger make.
Supply and and fixing of 8 way single pole and neutral MCB Double door type sheet steel enclosure Distribution board with 1 No.40 A ELCB IP 42 protection with 1 No 32A DP MCB as incoming and 6 Nos. 6A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection only. The MCB DB and MCB's should be of Legrand / Hagger make.
Supply and fixing of 6 Way 7 segment TPN MCB distribution board with metal / acrylic double door cover with IP 42 protection in sheet steel enclosure with 100A 4 pole MCB isolator as incoming and 3Nos.25A 30MA DP ELCB and 18Nos.6A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark. ( like Legrand (MDS)/Hager (L&T) make)
Supply and fixing of Vertical type 4 way triple pole neutral MCB distribution board in sheet steel enclosure with 100A 4 pole MCB as incoming 3 Nos. 32 A SP MCB and 3 Nos 32 A TP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark (like Crabtree Load Line make)
Supply and fixing of 4 Way 7 segment TPN MCB distribution board with metal / acrylic double door cover with IP 42 protection in sheet steel enclosure with 63 A 4 pole MCB as incoming and 3Nos.40 A 30 MA DP ELCB and 12Nos.6A to 32 A SP MCB as outgoing in flush with wall and making good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark ( like Legrand (MDS)/Hager (L&T) make)
Supply and Run of 2 of 2.5 sq.mm. (36/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe Concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour.
Supply and run of 2 of 4 sq.mm (56/0.3) PVC insulated SC unsheathed Copper Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour.
Supply and run of 2 of 6 sq.mm (84/0.3) PVC insulated SC unsheathed Copper Conductor of 1100V Grade in suitable PVC rigid pipe concealed in wall and ceiling with contiinuous earth wire connection of 14SWG TC wire and making good of the concealed portion with suitable colour.
Supply and run of 4 of 6 sq.mm (84/0.3) PVC insulated SC unsheathed Copper Conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection by 14 SWG TC wire and making good of the concealed portion with suitable colour.
Supply and Run of 4 of 10 sq.mm. (140/0.3) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire with painting of suitable colour.
Supply and Run of 4 of 16 sq.mm. (101/0.45) PVC insulated SC unsheathed copper conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire with painting of suitable colour.
Supply, erection ,testing and commissioning of 800A capacity vermin dust proof cubical of 14SWG line quality MS sheet steel enclosures for accommodating the 800A TPN copper busbar and rising main of 2” x 1/2 ” copper busbar 3 phases and neutral earth bus bar 2 Nos copper of 1” x 1/8” and with provision for accommodating incomer MCCB,and adaptor boxes and tape off switches including copper inter connect to the stretch oh height building. Make : L&T / C&S / Legrand / Eqt (Separate Rising mains for essential and non essential power )
Supply and fixing End Feed Unit and 4P 800A MCCB and flange End Unit (Schneider / L&T / Legrend Make)
Supply and fixing of End Cover for the rising main.(Schneider / L&T / Legrend Make)
Supply and fixing of 4P 250A, Tap off Box with MCCB. (Schneider / L&T / Legrend Make)
Supply and fixing of 4P 400A, Tap off Box with MCCB. (Schneider / L&T / Legrend Make)
Supply and fixing of Spring Hanger, Edge wise hanger, for rising main. (Schneider / L&T / Legrend Make)
Supply and fixing of Copper Flexible (braided). (Schneider / L&T / Legrend Make)
Supply and laying of 2 Runs, 3 ½ x 400sq.mm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.
Supply and clamping of 2 Runs, 3 ½ x 400sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps.
Supply and fixing of brass cable gland for 3½ x400 sq.mm PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3½ x 400 sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.
Supply and laying of 2 run 3 ½ x 185 sq.mm PVC armoured LTUG Aluminium armoured cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 metre Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.
Supply and clamping of 2 run 3 ½ x 185 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps.
Supply and fixing of brass cable gland for 3 ½ x 185 sq.mm PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3½ x 185 sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.
Supply and fixing of brass cable gland for 3½ x 120 sq.mm PVC armoured LTUG cable with earth connection.
Supply and clamping of 3 ½ x 120 sq.mm PVC LTUG armoured LTUG cable on post or on wall with MS Clamps.
Supply and providing cable end termination of 3 ½ x 120 sq.mm PVC LTUG Aluminium armoured cable with necessary aluminium cable sockets by crimping etc. with electrical connection complete.
Supply and Clamping of 3.5 X 400 sq.mm PVC LTUG Armed Aluminium Cable on wall with MS clamp.
Supply and laying of 4 x 16 sq.mm PVC armoured LTUG Aluminium armoured cable in a trench to be excavated at a depth of 0.75 metre putting 0.15 mt. Layer of sand and covering the cable completely with bricks and sand and refilling the earth to make good.
Supply and clamping of 4 x 16 sq mm PVC LTUG armoured LTUG Aluminium armoured cable on post or on wall with MS Clamps.
Supply and fixing of brass cable gland for 4 x 16 sq.mm PVC armoured LTUG Aluminium armoured cable with earth connection.
Supply and Laying of 3 1/2 x 25 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and Clamping of 3.5 X 25 sq.mm PVC LTUG Armed Aluminium Cable on wall with MS clamp.
Supply and fixing of brass cable gland for 3.5 X 25 sq.mm PVC armoured LTUG Cable with earth connection.
Supply and Providing cable end termination for 3.5 X 25 sqmm PVC LTUG alu armoured Cable with necessary alu cable sockets by crimping etc with earth connection complete.
Supply and erection of 8mtr. double arm bracket octagonal pole of free standing with continuously tapered structure made up of HT sheet steel designed to with stand wind velocity as per IS – 875 hot dip galvanized both internally and externally confirming to BSEN: ISO 1461 (65 micro thickness) the octagonal pole shall be erected on the foundation concrete with foundation bolt M 24 x 700 mm 4Nos. and HT steel pole having a base plate of size 250 x 250 x 12 mm and suitable size door at the bottom with locking arrangements with following pole specification. Height of pole : 7000 mm Bottom dia : 130 mm Top dia : 70 mm Thickness of Pole : 3 mm Bracket : 1000 mm With octagonal pole with Double arm bracket will have 2 Nos of 90W LED Street Light Fitting NEXUS NEO LED streetlight made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 Protection. 10KV SPD included. Efficacy : 110LM/W to be approved by PWD officials, with necessary service wires from fuse box to the fitting with 10 Mtrs. of 3 Cx 2.5 sq.mm PVC insulated copper cable with necessary connection. The junction box provided with 1No 4 way terminal blocks with Hylum sheet with 1Nos 10A SP MCB with connection complete, testing and commissioning as directed by the departmental officers.
Supply and erection of 8mtr. Single arm bracket octagonal pole of free standing with continuously tapered structure made up of HT sheet steel designed to with stand wind velocity as per IS – 875 hot dip galvanized both internally and externally confirming to BSEN: ISO 1461 (65 micro thickness) the octagonal pole shall be erected on the foundation concrete with foundation bolt M 24 x 700 mm 4Nos. and HT steel pole having a base plate of size 250 x 250 x 12 mm and suitable size door at the bottom with locking arrangements with following pole specification. Height of pole : 8000 mm Bottom dia : 130 mm Top dia : 70 mm Thickness of Pole : 3 mm Bracket : 1000 mm With octagonal pole with single arm bracket will have 1 Nos of 90W LED Street Light Fitting NEXUS NEO LED streetlight made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 Protection. 10KV SPD included. Efficacy : 110LM/W [Model LSTP-90-CDL-M Crompton Make] to be approved by PWD officials, with necessary service wires from fuse box to the fitting with 10 Mtrs. of 3 Cx 2.5 sq.mm PVC insulated copper cable with necessary connection. The junction box provided with 1No 4 way terminal blocks with Hylum sheet with 1Nos 10A SP MCB with connection complete, testing and commissioning as directed by the departmental officers.
Supply and erection of 8mtr. Single arm bracket octagonal pole of free standing with continuously tapered structure made up of HT sheet steel designed to with stand wind velocity as per IS – 875 hot dip galvanized both internally and externally confirming to BSEN: ISO 1461 (65 micro thickness) the octagonal pole shall be erected on the foundation concrete with foundation bolt M 24 x 700 mm 4Nos. and HT steel pole having a base plate of size 250 x 250 x 12 mm and suitable size door at the bottom with locking arrangements with following pole specification. Height of pole : 8000 mm Bottom dia : 130 mm Top dia : 70 mm Thickness of Pole : 3 mm Bracket : 1000 mm With octagonal pole with single arm bracket will have 1 Nos of ALL-IN-ONE SUNSOKO SOLAR 100W STREET LIGHT Smart Integrated Solar Street Light with built in mono Crystalline Panel, Lithium Ferro Phospate (LiFeP0 4 ) Battery, MPPT Charge Controller and PIR Sensor with Colour Temperature 6000-6500K. 2 Days Autonomy With Dimming Profile with connection complete, testing and commissioning as directed by the departmental officers.
Supply, erection, testing and commissioning of Three phase automatic street light controller of outdoor type housed in suitable size power coated enclourse made 8 KW accommodating the following with necessary internal wiring with 10 Sq.mm Unsheathed Copper wire. a) 63A four poie MCB=1 No (1/C) b)32A Four pole MCB=4Nos (O/g) c) 24 Hrs Time switch (Timer) with Batter backup= 1 No d) 40A Three phase contactor with 230v coll =1No (MCB’s & Timer: Legrand/equivalent contactor L & T /Siemens/BCH the metal danger board shall be fixed at approximate location.
Supply and fixing of 25 W LED gate light fitting (make like Havels) Model No. CORALPT25WLEDPSYMTOCP complete with 32 mm dia G.I pipe (Class "B") complete on the existing post / wall with PVC unsheathed copper leads MS clamps and aluminium painting.
Supply and erection of Aesthetically designed decorative hot dipped galvanised mild steel step pole with grey powder finish.Compatible for all Havells post top range. Window - Plasma cut & duly chamfered opening window of 300x110 mm for terminal connections & mounting accessories. Window cover is fitted with allen screws to the pole of 3.5 mtr length with Aesthetically designed decorative pole base cover, enhancing the appearance of the pole with construction of Masonry pedestal with 1 1/4" G.I. pipe for supply cable entry in/out arrangements and fixing the SMC Junction Box fire proof and shock proof with suitable clamp of size 275 x 150 x 100mm with door and lock and key arrangements in corporating 1 No 10A DP MCB for control and 4 way connector on suitable hylem sheet to be housed in the above junction box with painting and supply and fixing of Aesthetically designed 50 W LED post Top with aluminium enclosure, powered with high power LEDs as lightsource and die casted heat sink exhibits classic Victorian look with symmetrical light distribution and excellent heat dissipation for long life. Model No. JUPITERMAXIPT50WLED830PSYMTOPC complete on 0.5 mtr of 32mm dia G.I. pipe (class B) with suitable cowl arrangements and using 3 Nos of bolt fixing on the above post including inter connection with PVC unsheathed leads with coil earthing complete.
Supply and Laying of 2x10 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. (Post op Lantern)
Supply and Clamping of 2x10 sq.mm PVC LT UG Armed Aluminium Cable on wall with MS clamp. (Post op Lantern)
Supply and fixing of brass cable gland for 2x10 sq.mm PVC armoured LTUG Cable with earth connection. (Post op Lantern)
Supply erection, Testing and commissioning of 2 TR split type 5 star rated AC units fitted with hermetically sealed Air compressor with Non CFC refrigerant air cooled condenser, fan etc. and 1 No indoor High wall mounted 2.0 TR capacity evaporator unit complete with cooling coil, blower motor and connected accessories, control etc chord wire connecting indoor and outdoor unit with drain pipe suitable for operation on 230V + 10% 50Hz sinle phase AC supply. (Make - Carrier / OGeneral / Daikin/ Toshiba)
Supply and fixing of 5 KVA voltage stabilizer (V guard /Eq.make ) suitable for 2.0 tons capacity split type air conditioner with 3 minutes time delay and low / high voltage cut off switch (wall mounting) with necessary wire connection.
Supply and laying of 5/8'' and 3/8'' copper pipe. (Extr beyond 3Mtrs supplied with AC Unit)(For split AC Unit).
Supply and Fixing of MS stand for fixing outdoor units. (For Split outdoor unit)
Supply, Erection, Testing & Commissioning of 3.0 TR norminal capacity ceiling suspended ductable air conditioner with the following components. 3.0 TR capacity ceiling suspended Ductable Air conditioner high tech,low height,low noice level indoor unit with fin and tube type cooling coil,Detachable type drier provided in refrigerant cicuit to reduce moisture content multi stage type distributor for feeding equal quantities of the refrigerant mixture to all the section of the coil,with required valves,directly coupled blower to reduce troubles and wear & tear compared to belt drive blower.Thermostatic expansion valve lift and pull type aluminum framed durable, washable air filter.Integrated electrical panel with complete microprocessor control with display for easy operation and maintenance of unit common operating conditions of 450 F suction temperature Auto reset type HP/LP safety cut to improve reliability of compressor. Air conditioner high tech Outdoor unit with power saving high efficiency sturdy and rugged 1 No of scroll comprssor each with inbuilt internal thermal protector, internal pressure relief valve,Auto reset type HP/LP safety cut out to improve reliability of compressor and condenser shell be made of super slit high efficient aluminum fins mechanically banded to copper tubes condenser 'L' type coil to be rigidly fixed to unit frame with fasteners.imported condenser fan & fan blades to be statically and dynamically balanced to reduce noise and vibration.The fans are direct driven 3 phase motor with protection.Condencing temperature 1300 F for the system operations.
Supply, Erection, Testing & Commissioning of 8.5 TR norminal capacity ceiling suspended ductable air conditioner with the following components. 8.5 TR capacity ceiling suspended Ductable Air conditioner high tech,low height,low noice level indoor unit with fin and tube type cooling coil,Detachable type drier provided in refrigerant cicuit to reduce moisture content multi stage type distributor for feeding equal quantities of the refrigerant mixture to all the section of the coil,with required valves,directly coupled blower to reduce troubles and wear & tear compared to belt drive blower.Thermostatic expansion valve lift and pull type aluminum framed durable,washable air filter.Integrated electrical panel with complete microprocessor control with display for easy operation and maintenance of unit common operating conditions of 450 F suction temperature Auto reset type HP/LP safety cut to improve reliability of compressor. Air conditioner high tech Outdoor unit with power saving high efficiency sturdy and rugged 1 No of scroll comprssor each with inbuilt internal thermal protector,internal pressure relief valve,Auto reset type HP/LP safety cut out to improve reliability of compressor and condenser shell be made of super slit high efficient aluminum fins mechanically banded to copper tubes condenser 'L' type coil to be rigidly fixed to unit frame with fasteners.imported condenser fan & fan blades to be statically and dynamically balanced to reduce noise and vibration.The fans are direct driven 3 phase motor with protection.Condencing temperature 1300 F for the system operations.
Supply, Erection, Testing & Commissioning of 5.5 TR norminal capacity ceiling suspended ductable air conditioner with the following components. 5.5 TR capacity ceiling suspended Ductable Air conditioner high tech,low height,low noice level indoor unit with fin and tube type cooling coil,Detachable type drier provided in refrigerant cicuit to reduce moisture content multi stage type distributor for feeding equal quantities of the refrigerant mixture to all the section of the coil,with required valves,directly coupled blower to reduce troubles and wear & tear compared to belt drive blower.Thermostatic expansion valve lift and pull type aluminum framed durable,washable air filter.Integrated electrical panel with complete microprocessor control with display for easy operation and maintenance of unit common operating conditions of 450 F suction temperature Auto reset type HP/LP safety cut to improve reliability of compressor. Air conditioner high tech Outdoor unit with power saving high efficiency sturdy and rugged 1 No of scroll comprssor each with inbuilt internal thermal protector,internal pressure relief valve,Auto reset type HP/LP safety cut out to improve reliability of compressor and condenser shell be made of super slit high efficient aluminum fins mechanically banded to copper tubes condenser 'L' type coil to be rigidly fixed to unit frame with fasteners.imported condenser fan & fan blades to be statically and dynamically balanced to reduce noise and vibration.The fans are direct driven 3 phase motor with protection.Condencing temperature 1300 F for the system operations.
Supply and filling of R-22 Refrigerant Gas.
Supply and fixing of flexible canvas connection between Airconditioning unit and ducting.
Supply, fabrication and fixing of MS Channel for Mounting the Airconditioning Indoor Unit.
Supply, fabrication and fixing of MS Channel for Mounting the Airconditioning Oudoor Unit.
Supply and fixing of laying and bracing of 1-1/8 Inches Hard drawn copper refrigerant piping interconnecting indoor unit and condensing unit with necessary fittings, supports etc.,
Supply and running of 5/8" Hard drawn copper refrigerant piping liquid line with insulation.
Supply and fixing of water drain pipe line (1” PVC Pipe ).
Supply and fixing of Fabrication and erection of 22SWG Galvanished Sheet Steel ducting with necessary supports.
Supply, Fabrication and erection of fabricated ducting made up of GI sheets of 24 gauge thickness complete with MS angle supports, angle flanges, anchor fastness, tees and bends, wherever necessary etc. as required.
Supply and fixing of extruded aluminum powder coated, Supply and return Air Grilles / Diffusers with Volume Control Damper.
Supply of extruded aluminium powder coated Gravity Louvers.
Supply and providing acoustic for initial portion of ducting with 12mm thick Fibre Glass Rigid Board covered with Tissue Paper and Aluminum Perforated Sheet.
Supply and providing thermal insulation of 9mm thick vidoflex with Aluminum Foil.
Supply and providing of 2.5Sq.mm 4 core copper flexible cable.
Supply and providing of pipeline nitrle rubber insulation for Refrigerant and drain pipe lines.
Supply, erection, commissioning, testing and handing over of 1No 250KVA Diesel Generator Set canopy, fuel tank battery charging alternator with AMF Control Panels developing 3phase electrical output 250KVA powered by diesel engine of 0.8P.F Three phase 415/420Volts, 50c/s, 345BHP at 1500RPM as detailed below. a]. ENGINE: Oil engine make model 6SL 8800 TA turbo charged vertical inline 6 cylinders. Liquid cooled diesel engine developing 310.3 HP at 1500 RPM conforming B.S 5514 / 6490 or IS 10000 incorporating the following accessories. The engine shall comprise the following standard fittings Flexible coupling with guard, Flywheel, Air cleaner, Fan blower type with guard, Radiator with guard, water pump engine mounted, Fuel pump, Fuel filter, Lubrication oil filter, Lubrication oil pump, Governor (mechanical/hydraulic) Exhaust silencer residential type. b]. Electric starting equipment, complete with starter motor, dynamo and battery with cables, flexible exhaust piping of 50cms length c].ENGINE INSTRUMENT PANEL MOUNTED: Starting push button with key, lubricating oil temperature gauge, lubricating oil pressure gauge, water temperature gauge, safety control for low lubricating oil pressure, safety control for high water temperature, safety control for over speed, hour meter and RPM meter indicator, battery.
f].FUEL TANK: Fuel tank of 460 liters capacity to generator with inlet and outlet connection filling cap drain plug level indicator etc., complete. g].BASE FRAME: The base frame should be fabricated with MS channel of rigidly welded constructed for mounting the generator set. The engine and alternator should be coupled by suitably designed diaphragm type flexible coupling with guard and mounted on the base frame with proper alignment. The supply of generator set includes loading, unloading and transportation charges. h]. Supply of maintenance and operating manual with list of engine parts and alternator parts. j]. Erection Testing and Commissioning The erection shall comprise of I].Providing suitable concrete foundation with plain cement concrete 1:2:4 with stand cushion all around the foundation -1Job II]. Providing ISI earthling with earth electrode of 2.1 meter length, 1 ½ ” diameter class ‘B’ GI pipe for the alternator and control panel including masonry work with cover slabs for earth pits -6 Nos III]Providing earth connection and interconnection of earth pit by 1”x1/8” copper conductor - 30 meters IV].Providing 200 liters fuel oil to run the set for 8 hours on load testing and commissioning using water rheostat or suitable leading elements-1 Job. V] First charging of lubrication oil and first charging of starting battery – 1Job.
VI] Supply of tools such as 1no. 15” cutting pliers, 1no. 6” screw driver, 2no.9” screw drives, 1set of 6nos, double ended spanners, 1no. Adjustable spanner, 1no. ½ Ib hammer, 1no. Spanner for removing engine oil plug, 1no. Line tester required for the for the maintenance and operation of the generator set -1set VII].Preparation of site plan, physical layout, electrical line schematic diagram in 10 sets. getting drawing approval from CEIG, preparation of completion report, rectification report and arranging CEIG’s inspection and obtaining safety certificate. Preparation of one set of approved drawing and a copy of safety certificate in a neat frame work to be fixed in the generator room – 1set. VIII: Supply and laying of 2 run of 3 ½ x 240 sq.mm PVC LTUG cable from the alternator to the control panel – 10 Mts. IX: Terminating the above cable gland, cable sockets, gland earthing etc – 8 sets. BATTERY: 2 No's 25 plate 180 AH 24V battery with one set of connecting leads of 75 Sq.mm copper cable with sockets etc.,
MANUALS & DOCUMENTATION : Operation and maintenance manual for engine, maintenance manual for alternator, engine test certificate, alternator test certificate, circuit diagram for control panel, DG set test certificate, CPCB compliance label fixed on canopy. Supply of ACOUSTIC ENCLOSURE suitable for 250KVA Diesel Generator set. The acoustic enclosure should be free standing floor mounting type with modular construction with the provision to assemble and dismantle easily and designed to suit all weather conditions The construction details / specification: Acoustic Modules: Outer body: 2mm thick CRCA sheet Door: 2mm thick CRCA sheet Inner surface:0.8mm thick GI perforated sheet / Perforation area should be > 2 / 3 of total area Insulation:100mmthickRockWool (Density: 65kg / cub.m or as approved by competent authority) to suit CPCB norms Skeleton structure Channels: should not be less than ISMC75 and ISMC 100. Cleats: should not be less angle 40x6mm and 50x 6mm. The sheet metal competent shall be pre-treated by seven tank process. The joints should be designed in such a way the airborne noises are prevented. For larger panels, special care should be taken to prevent deformation. Adequate ventilators should be provided so that the generator performance is not affected and also the temperature inside is limited. The maximum permissible sound pressure level should be as per the norms prescribed by the central Pollution Control Board/ State Pollution
Control Board / Competent Authority concerned or should be 75db(A) at 1meter from the enclosure surface, whichever is advantageous to the department The emergency stop and suitable meter with digital display to indicate inside ambient temperature of the enclosure should be available on the enclosure panel. The enclosure should be only poly polished based coated inside and outside The enclosure provided shall be duly approved by the Engine Manufacture of the Engine provide for Diesel Generator sets mounted inside and should be to the satisfaction of Inspection / Testing Authority concerned. (Kirloskar/Cummins/Greves Make)
ERECTION AND TESTING AND COMMISSIONING Providing gen set bed size of 8340 mm length x 4740mm width x 1200 mm height suitable concrete foundation with cement concrete 1:2:4 with sand cushion all around the foundation erection of 250 KVA Generator set ovwer the existing foundation and erection of generator set with proper alignment over the existing foundation to suit 250 KVA Gen set.
Supply and installation of exhaust piping of sufficient length with suitable MS pipes so asa to extenf\d outside the generator room with necessary thermal insulation.
Supply of tools such as 1no. 15” cutting pliers, 1no. 6” screw driver, 2nos. 9” screw drives, 1set of 6nos, double ended spanners, 1no. Adjustable spanner, 1no. ½ Ib hammer, 1no. Spanner for removing engine oil plug, 1no. Line tester required for the maintenance and operation of the generator set -1set.
Supply and demonstration of the following safety accessories a) 1 meter x 1 meter x1/2 inch 22 kv rubber mat - 2 nos. b) one set of 4 nos. 9 liters fire buckets with metal stand frame - 1set c) first aid box with medicine - 1no d) 11 kV rubber hand gloves - 2 nos. e) 2 Kg capacity dry powder type fire extinguishers - 2 nos f) Hand operated pump to transfer fuel from standard barrel to fuel tank - 1 no. g) First aid chat in Tamil and English - 1no. h) Battery water acidity tester - 1 no.
Earthing as per the ISI specification with an earth electrode of 2.1mt class 'B' GI pipe of dia not less than 40mm, with copper earth plate of size 125mm x 50mm x 6mm, with necessary funneling arrangements with necessary masonry work and with 38mm RCC cover slab for the brick masonry.
Supply and run of 25mm x 3mm tinned copper flat with necessary clamps / supports on wall / floor / ground for earth connection.
Supply and Run of 1 of No.8 SWG copper wire in suitable PVC rigid pipe on wall / floor / ground for earth connection.
Supplying Single Stage Silver Code Super Conductor Lightning diverter with Silver tipped Receiver, Diffuser, H.T Divider With discharging diverter.
Supplying and Laying the Copper Wire 8mm swg for open air network system.
Supplying and Fixing G.I center sturdy pole.
Supplying and Fixing porcelain wall insulator with PVC pipe, clamps & screws etc.
Supplying and Digging earth and providing earth chemicals, earth discharging units with copper base plate.
Providing S cup holding for the building bottom to top of the building rented.
Civil work – masonry, concrete with materials and labor charges. & Transportation charges.
Fabrication, Supply, Installation, testing and commissioning of 22KV DP Pole structure with the following accessories : (I) 2 Nos of 200mm x 100mm RS Joist 33 feet length with bottom plates. (II) 1 Set of 3 Nos. 22KV Disc Insulator with fixing channels 12 feet length and earthing etc. (III) 22KV 3 insulator tilting type AB Switch with operating rod, 2 Nos. of 12 feet length supporting channels and earth connections etc. (IV). 1 Set of 3 Nos. 22KV Drop out Fuse with 11KV PT Insulators, supporting channels of 12 feet length 2 Nos, cross supporting channel, earth connection etc. (V). 1 Set of 3 Nos. 22 KV Lightening arrestor with supporting channels of 12 feet length and earth connections etc. (VI). 1 Set of 3 Nos. 22KV Pin Insulator with GI Pin and stool, supporting channels of 100 x 50mm x 12 feet length with earth connections etc. for jumber supporting. (VII). The RYB 3 Nos. of over head No. 0 SWG Copper wire from EB DP Structure to consumer EB Structure and AB Switch to Transformer etc. with coloring of No. 0 SWG Copper wire, complete painting of DP structure with 1 coat of zinc chromate primer and 2 coats of aluminium paints complete set etc. The above works should be carried out strictly based on IES, CEA, CEIG Regulations.[CER/NAMAKKAL]
Design manufacturing Supply, erection, testing, commissioning and handing over of 22KV 25KA HT Three panel vacuum Circuit Breakers Switch Board VCB Comprising one number 800A 18.4 KA VCB as incoming and 2 Nos 630 a 18.4 KA VCB as outgoing panels for indoor installation each panel comprising 1. Draw out type 22 KV 800 A 18.4 KA Horizontal Draw out / Horizontal isolation Vacuum Circuit Breaker with Motor (230V AC. – AC source of supply to be arranged purchaser) operated spring charged mechanism. Anti Pumping Device 110V DC shunt trip and closing coils (DC source of supply to be derived from a Power Pack suitable for 3 tripping and two closing operation counter, 4 no + 4 NC spare Aux, contact for customer use, automatic safety shutter, mechanical close / trip knob, mechanical on/off indication, operating hand, 110V AC – 110V DC Power Pack etc (Incoming 1 No. 800A Outgoing 2 Nos of 630 A). 2. 22KV / Root 3 / 110V /Root3 – Three phase, 3 Limb 200VA Class 1 Resin Cast Draw Out type Potential transformers complete with HT and LT HRC Fuses (Incoming – 1 No.) 3. Current Transformers of 100 – 50/5-5 Amps. Dual Core (Core 1 -15 VA class 1 for metering and core 2-15 VA 5P 10 for protection) for incoming 3 Nos, current transformers of 30/5-5 Amps dual core (Core 1-15VA Class 1
Control wiring with appropriate colors Bus bar Ratings 22KV, 800Amps Bus bar with insulation 22KV, 800Amps Bus bar with insulation Earth bus Common For Switchgear Heater ON / OFF switch with filament type 100Watts space heater & thermostat, single phase switch with socket, 9W cubicle Lamp for panel illumination with snap type door limit switch, Fuses / MCBs for AC / DC conrol.MS Sheet steel enclosure & installation suitable for Incoming (Excluding Cable termination kits, lugs & glands) Outgoing (Excluding Cable termination kits, lugs & glands) Surge Arrester Power Pack ( Make : SRIWIN / Kirloskar)
Supply and laying 22 KV 3 core 240 sq.mm XLPE HTUG Cable in existing trench / pipe laid in ground.
Supply and laying 22 KV 3 core185 sq.mm XLPE HTUG Cable in existing trench / pipe laid in ground.
Supply and providing cable and termination suitable for 22 KV 3 core 240 sq.mm XLPE HTUG cable with necessary Indoor type heat/cold shink able joint kit and accessories. (Make : Ray Chem / MSeal / Acechem)
Supply and providing cable and termination suitable for 22 KV 3 core 185 sq.mm XLPE HTUG cable with necessary Indoor type heat/cold shink able joint kit and accessories. (Make : Ray Chem / MSeal / Acechem)
Supply and run of 25mmX6mm tinned copper flat with necessary class /Support on wall / floor Ground for earth connection. (Body earth for the RMG, Transformer neutral earth )
Preparation of electrical schematic diagram site plans physical layout 10 copies and payment of CEIG fees submission of completion report obtaining drawing approval safety certificate etc., complete including lamination copy fixed at panel room.
Providing fire fighting equipements like CO2 extinguisher, 4 Nos of Bucket with stand, tongue tester, 4 Nos of rubber hard gloves and Rubber mat etc.,
Supply and fixing of Neutral CT protection class 75/5A with suitable outdoor type MS enclosure, busbar arrangements with necessary angle iron arrangements, control cable connection from ACB to Neutral CT box etc.,
Supply, erection, testing and commissioning of 630 KVA, 22KV, 433V, HV - Delta, LV Star off load tap changing, copper wound, outdoor type, distribution transformer as per IS 1180(Level I) ON AN cooled, confirming to relevant IS 1180 / IEC 60076, Level-II Class A Insulation and mounted on 300 x 90 x 6mm base channel bolted to a suitable RCC plinth of height 5' and RCC foundation to a depth of 2' with reinforcement by suitable MS rods 150Kg / m3 capable of bearing 2 ton weight and connected works fitted with the following: 1) HT Cable End box suitable for connection of 3 x 240 sq.mm HT cables & LT Cable end box suitable for connection 1600A Bus duct 2) Bucholz relay with shut off valve, alarm and trip contacts. 3) Dehydrating silica gel breather. 4) Conservator with oil filling pipe, cap and drain plug valve. 5) Tank drain cum bottom filter valve with plug. 6) 4 Nos. plain rollers uni and bi-directional under base channels with skid. 7) Dial type thermometer with pocket to measure oil temperature stem type. 8) Tank top filter valve with plug. 9) Explosion vent with diaphragm. 10) Oil level gauge with marking. 11) Two body earthing terminal and additional neutral bushings for solid earthing. 12 Rating and terminal marking diagram plate. 13) Lifting hooks/ Lifting eyes/ Jacking pad to facilitate easy movement of Transformer to ground level, cover lifting lugs.
14) Off load hand operated tap changing switch at standby height from ground level. 15) Tapping on primary winding for voltage variation +5% to -5% in steps of 2.5%. 16) Welded and detachable radiators. 17) Air release device. 18) The transformer should be supplied with first filling of oil as per IS 335 with high dielectric strength, BDV and flash point. 19) Monogram plate. 20) Shut off valve for surge relay 21) Oil surge relay 22) All removable covers shall be provided with weather proof hot oil resistant, resistance gaskets to prevent leakage of water into core, and oil from the tank with low no load loss 1100W and full load loss 6400W, impendence 5% with temperature rise oil / winding 50° - 55°C (Make: Kirloskar / Rowsons )
Supply, erection and commissioning of duct and vermin proof type 1000 A capacity Copper Bus duct made out of 16 SWG CR sheet with power coated painting. The bus duct provided with 1000 Amps.Rating CU. Flat for 3 phase and 1000 A rating Copper flat for neutral with RYB & N colour sleeving. Bus bar size : 1 Run 100x6mm CU. flat for 3phase and neutral.
1000A TPN flexible joint Fabrication, supply, erection and commissioning of 1000A flexible joint to the bus bars required to suitable bus bars.
Design, Supply, erection, testing and commissioning of 1000A draw out type floor, mounted MV cubical bus bar chamber dust and vermin proof and accomodating the following switch and 2 Nos. ACB as incomer units and 1 no ACB as Bus coupler with the following items of work complete to satistfy the latest IE Rules and CEIG guidelines, Supply and fixing of suitable size bus bar chamber made up of 16 SWG MS sheet steel with 4 Nos of 4"x1/4 " tinned copper bus bar for 3 phases and 8 Nos of 2"X1/2" tinned copper bus bar for Vertical Bus bar and 2 Nos of 1"X1/4" tinned copper for earthing bus on suitable bus bar insulator (Epoxy insulator ) with maximum creepage distance and supported on MS base channel frame work of size 4"X2"X 1/4"- 1 Set INCOMING Supply and fixing of 3 nos . 1000A basic rating 4 pole 433V LT ACB conforming to IS 13947 - 2 IEC 60947 -2 with making capacity of 25 KA and breaking capacity of 50 KA at 600V AC with all accessories for standard horizontal manual draw out type ACB equipped with auxilizry contacts and all accessories for closing and openning operation with micro processor SR 18 G relay over current trip device adjustable to LTD, STD and release with time delay EF release short circuit protection , Mains CTs for 3 phases lockout features separate mould base for each pole for easy maintenace all relvenat protection safety accessories as per CEIG , IE rules inforce with inter connection and terminations as required in speciications (Three Lock Two Key System) OUTGOING 1) Supply and fixing of 800A FPN double break front operated switch disconnector fuse interior only with HRC fuse -3 Nos interconnected with
1 1/2x1/4 " bus with main Horizontal bus 1) Supply and fixing of 630A FPN double break front operated switch disconnector fuse interior only with HRC fuse -3 Nos interconnected with 1 1/2x1/4 " bus with main Horizontal bus 1) Supply and fixing of 400A FPN double break front operated switch disconnector fuse interior only with HRC fuse -4 Nos interconnected with 1 1/2x1/4 " bus with main Horizontal bus 2) Supply and fixing of 250A TPN double break front operated switch disconnector fuse interor only with HRC fuses - 2 Nos interconnected with 1 "x1/4 "bus with main Horizontal bus
3) Supply and fixing of 125A TPN double break front operated switch disconnector fuse interor only with HRC fuses - 1 Nos interconnected with 1 "x1/8 "bus with main Horizontal bus 5) 1000 Amps 4 pole LT ACB bus coupler, inter connecting all the LT ACB and switches to bus bar with 2" x 1/2" insulated tinned copper flats and painting of phases and neutral indication Double Earth connection of the switches and ACB's to earth bus using suitable tinned copper flats by 2 runs of 1"X1/8" Supply and fixing of pilot lamp arrangements with toggle switches to the control to each phases and with grid connection in sutitable separete compartments with in the cubicle as per CEIG rules 2 Sets of supply and fixing Electronic multifunctional meter Class 1.0 flush mounting L&T make 1 No. of supplying and fixing of earth fault relay with necessary CT arrangement (L& T ) Make Supply and fixing of danger board with spray painting the entire panel with 1 coat of red oxide primer and 2 coat of super synthentic enamel metallic paint with superscribing the names of places to which supply is fed feeder sizes of cables direction of cables etc., erection of panel board complete with suitable foundation bolts and nuts including commissioning (All switches and ACBS are of L&T /Siemens/GE Make
Design, supply, erection of 200 KVAR, 8 stage switching, sequence automatic power factor correction wall mounting stand vermin proof cubical panel board made of 16 SWG CRCA sheet steel with supply and fixing of the following interior mounting capacitor chamber relay with metering chamber and compartmentalised out going feeders with suitable capacity MCCB with panel board with provision for louvers and cooling fan for proper ventilation to manage heat load incoming - DPX 630A FP MCCB with rotary handle. Outgoing : 8 stage capacitor bank Contactors : Bharatia Cuttler Hammer/L&T Heavy Duty contactors. Relays : World class solid state relays with TM2 technology as an option. Capacitor MPP capacitor 8 stage from 1 KVAR to 250 KVAR 1. stage -5 KVAR 2. stage -10 KVAR 3. stage -15 KVAR 4. stage -20 KVAR 5. stage -25x2 KVAR 6. stage -25x2 KVAR 7. stage -25x2 KVAR 8. stage -25x2 KVAR Bus bar: 2 run of 52mm x 6mm tinned copper Metering : 1-500A Ammeter with CT coil 2) 0-500V voltmeter 3) Advance micro controller based intelegent power factor controller with self dianostic sensing and digital net work analayset with software for mentiory and saving para meter of a suitable multi function meter.
Indication: R,Y,B The panel should be coated with Epoxy based painting and the whole assembly fixed in suitable cubical panel grouted in floor with connection complete.
Design, Engineering, supply, fabrication, erection, testing, commissioning and handing over of 1No 20 persons capacity Gearless passenger Lift with machine room as per the following Technical specifications inclusive of all taxes and duties. Technical specifications: 1. Location: Kallakurichi Collectorate 2. No of Lift : 1 No 3. Type of lift : passenger lift.(1768Kgs) 4. Capacity of lift : 20 persons capacity Gearless passenger lift 5. Speed : 1.0 M / Sec 6. Type of Drive: Specific variable voltage variable frequency V3F drive with enhanced ride comfort and near Zero leveling functions. 7. No. of floors: 8 (Ground + 7 floors) 8. Total Travel : 23.8 mtrs Travel. 9. Leveling Accuracy: High level accuracy with smooth & jerk free stopping 10. Construction of Car: 18SWG High quality S.S 304 Grade car Neat hairline finish, S.S hand rail, SS floor line finish, Perspex false ceiling, stretcher impact protection. 11. Position of machine: Directly above the lift well. 12. No. of landing entrance: one in front 7 Nos 13. No. of car entrance: one in front only 14. Car entrance door: power operated V3F drive side opening sliding 18SWG stainless steel hair line finish. 15. Landing entrance door: power operated V3F sliding, opening 18SWG stainless steel hair line finish with provision for emergency key
28. Fireman’s switch: To be provided at ground floor 29. Minor builders work: to be provided by lift contractor. 30. Scaffolding: to be provided by lift contractor 31. Sill angles and facia plates: to be provided by lift contractor 32. Steel for lift machinery: to be provided by lift contractor 33. Servicing and maintenance: Free comprehensive servicing and maintenance should be provided by the lift contractor during the guarantee period of one year. 34. Automatic Rescue Device: To facilitate the landing of the lift to the nearest floor at the time of power failure. This shall consists of suitable type battery system with charger, invertor, under voltage protection system etc., complete with all accessories. 35. Provision of intercom with phone: To be provided by lift contractor 3 points EPABX system at three places vide 1) inside the car 2) Head room 3) at ground floor attender room 36. Lift License: Preparation of Drawing, payment of charges to CEIG and insurance policies if any and obtaining CEIG safety certificate as per lift act should be done by lift contractor. 37. Floor announciator with music, included 38. Special features: a. Infra red door sensor with full height screen. b. Tubular S.S hand rail in cars. c. Voltage stabilizer for circuit control. d. Stainless Steel signal fixtures. e. Vendal proof S.S. Button with S.S. cover f. SS hairline finish door frames for landing doors.
g. VF door Register signal h. Call Register signal i. Stainless steel facia plate for car operating panel and landing fixtures. j. Steel ladder for machine room and ladder for lift Shaft pit, k. On – Off switch for fan and light l. Over load warning indicator With audio announcement. m. Fall width half height rear panel mirror. 39. Provision of architraves covering all three sides up to a width of 300 decorum sheet of plywood with TW frame with aluminum beading architraves should also cover the thickness of still level door frame at the landing and indicator boxes at all landings. 40. Other standard features: Voltage stabilizer for control units, Over speed governor, phase failure and phase reversal relay alarm bell, T. Guide brackets for car and counter weight, rubber padding under winding unit, motor of adequate capacity, single reduction worm gear, electromagnetic brake with compression springs car safety gears buffer, electro mechanical door locks emergency key side supporting angles, motor over load protection devices final limits switch, main suspension ropes counter weights lifting hoist for mounting the machineries. All features as per differently abled persons act should be provided. 2hrs. fire retardent landding doors.
41. Guarantee: Guarantee for the materials and workmanship of equipments complete should be offered by lift firm for a period not less than one year. 42. Site testing in accordance with IS 14665 should be carried out at the time of handing over. Necessary spares and tools required for the maintenance for a period of one year 43. Supply of operation and maintenance manual with Necessary tools for Operation. The list of tools required should be detailed by the contractor in a separate sheet duly signed by contactor. (Johnson/KONE/ OTIS / Eq.)
supply and erection of 150mm GI tray to be fixed with the existing wall, Structure or in Trench in suitable angle iron support.
supply and erection of 300mm GI tray to be fixed with the existing wall, Structure or in Trench in suitable angle iron support .
Supply and installation of 4MP IP Bullet CCTV Camera with H.265 Video Compression, Smart IR, True Day Night, 3.6mm Fixed Lens, IP66 and IK10 Rated rugged housing , PoE or 12V DC support with necessary clamps and accessories.
Supply and installation of 150 meter IR Rang , 2MP 32X Digtal Zoom with 360 Digree PTZ (PAN. TILT. ZOOM) High speed Dome Camera with accessories.
Supply and installation of PTZ High speed Doome camera mounting kit with aeccessories.
Supply and installation of 16 Channel Network Video Recorder with high bandwidth, high security protocol gateway with hack protection with H.265 Video Compression, each channel supports 4K and PoE with 2 numbers of SATA ports for Hard Disk.
Supply of Western Digital Make or Equivalent 4TB Surveillance Hard Disk for NVR.
Supply of D-Link Make 8 Port PoE Switches for CCTV IP Camera.
Supply of D-Link Make 8 Port Fully Managed 10 /100 /1000 Layer-2 with 1G Uplink LAN Network Switch.
Supply of D-Link Make 24 Port Fully Managed 10 /100 /1000 Layer-2 with 10G Uplink LAN Network Switch.
Supply and fixing of 25mm PVC rigid pipe concealed in wall and ceiling and making good of the concealed portion with suitable colour for CCTV.
Supply and run of Cat-6 cable in existing concealed PVC rigid pipe on wall and ceiling. ( CCTV and LAN)
Supply and laying of 12 core ofc indoor cable in 50mm/38mm HDPE pipe in trench excavated at a depth of 0.75m and refilling the earth to make good.
Supply and run of 2x1.5sq.mm (22/0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in existing concealed PVC rigid pipe in wall and ceiling.
Supply and fixing of 4U Rack with accessories and fan with suitable angle iron frame work.
Supply and fixing of 42U Rack with accessories and fan with suitable angle iron frame work.
Supply and fixing of fan extra for the rack.
Supply and termination of Single Mode Media converter for Optical Fiber Cable.
Supply, erection, testing and commissioning of Uninterrupted Power Supply (UPS) unit of capacity 5KVA with input voltage 24V DC supply, output voltage 230V- 50HZ AC supply with following accessories / circuits and with 3 hrs. of battery backup at full load respectively. 1. Battery Charging device 2. Inverter Circuit 3. Overload as well as short circuit Tripping Device 4. Indication for all operations like Battery charging, over load, Low battery etc, 5. Reset Switch 6. Tubular Battery - 4 Nos of 12V DC / 150Ah 7. One Layer Wooden/ Steel Fabricated Stand
Supply and installation of Sony Make 40 inches Full HD LED Television with suitable wall mount on wall.
Supply of 2 Nos. 6A Switches with 2 Nos. 6A 5 Pin Universal sockets in suitable Plastic box with earth connection. (Legrand or Equivalent)
Supply and installation of Beetel Make M59 Model High quality Push Button Telephone with Caller ID.
Supply and fixing of Legrand Make Arteor Model or Equivalent double RJ11 Telephone socket with suitable module box and face plate in concealed.
Supply, installation, programming, testing and commissioning charges for NEC Make SV9100 Model EPABX Base unit for 256 analog extions, 8 trunks and 30 STP lines with softwares license so as to link all Exchanges within the premises.
Supply, fixing and termination of 20 pair MDF Box with module and Krone.
Supply, fixing and termination of 50 pair MDF Box with module and Krone.
Supply, fixing and termination of 100 pair MDF Box with module and Krone.
Supply and run of 0.5mm copper unarmoured 2 pair telephone cable in existing concealed PVC rigid pipe.
Supply and run of 0.5mm copper unarmoured 20 pair telephone cable in existing concealed PVC rigid pipe.
Supply and run of orbit Make or Equivalent 0.5mm copper unarmoured 50 pair telephone cable in existing concealed PVC rigid pipe.
Supply and fixing of Legrand Make Arteor Model or Equivalent double RJ45 LAN socket with suitable module box and face plate in concealed.
Supply and fixing of 12U Rack with accessories and with suitable angle iron frame work.
Supply of 3 Meters patch cord for linking EPABX Exchange boxes.
Supply, fixing and testing of 2 KVA online UPS with DC Voltage 36V with one hour backup and Exide Powersafe Plus SMF battery: 12v - 100AH in 3 Nos and one layer wooden/steel fabricated stand.Make and Model:APC or Equivalent.
Supply and installation of PA Booster Amplifier of 480W Power.
Supply and installation of PA Mixer Amplifier of 240W Power.
Supply and installation of PA Mixer Amplifier of 120W Power.
Supply and installation of 30W Wall Speaker with all relevant accessories.
Supply and installation of 15W Wall Speaker with all relevant accessories.
Supply and installation of DI400P Direct Injection box or customized XLR converter.
Supply and run of 2 core 1.5 sq.mm PVC Copper speaker Cable in suitable PVC rigid pipe concealed on wall and floor.
Supply and Laying of 8 core 7/36 shielded conference cable with PVC pipe and accessories etc.
Supply and installation of Shure Make BETA 58A Model XLR Supercardioid Dynamic Vocal Microphone with suitable stand.
Supply and installation of Chairman unit Long flexible gooseneck, Internal Loud speaker automatically mutes LED indicator, Headphones output . Make : Bosh CCSE-CU-700 series / Equivalent
Supply and installation of delegate unit Long flexible gooseneck, Internal Loud speaker automatically mutes LED indicator, Headphones output . Make : Bosh CCSE-CU-700 series / Equivalent
Supply and installation of Conference Control unit with following features, suppliies power upto 50 units and control upto 150 unit Male Make : Bosh CCSE-CU-700 series / Equivalent
Supply and installation of MX18 Model 18 inches gooseneck microphone with suitable base.
Supply and Installation of 1KVA Servo Voltage Stabilizer with No Waveform Distortion, Less than 1 sec Stabilization Time, Voltmeter displays output voltage, specifically designed for audio equipment, Over and Under Voltage Correction (Automatically regulates in both conditions),Wide Input Voltage Range for Indian Conditions 180 to 250Volts. Make: Studiomaster/Equivalent
Supply of XLR Male connector , XLR Female connector , 1/4" Mono connector, 1/4" TRS connector, soldering with Cables and connecting with accessories.
Supply and installation of Optoma Make 4200 Ansi Lumens Full HD Projector with ceiling mount kit.
Supply and run of 3 core 1.5 sq.mm PVC Power Cable for Projector in suitable PVC rigid pipe concealed in wall and ceiling.
Supply of Proxy Make 8U Wall mount Rack suitable for mounting amplifiers.
Supply of Proxy Make 12U Vertical Amp Rack Mount ATA Flight Case suitable for mounting amplifiers.
Supply and installation of Soundcraft Make EPM8 Model Pre Amplifier with 8 channel.
Supply and fixing of Sony Make or Samsung Make 55 inch LED Smart TV.
Supply of Liberty Make 20 Metre HDMI Cable.
Supply, fixing and termination of Legrand Make HDMI I/O Socket, Face Plate and PVC Module Box.
Supply and Installation of INBIO 460: 4 Door Controller Supports different Wiegand formats, and connects to ZK readers as well as HID, Mifare, and generic ID card readers Connects with a variety of electric locks, sensors, exit buttons, alarm devices, and indicators can be integrated with other security systems such as CCTV, Intrusion Detection, Fire Alarm Release, and elevastor Control for total security system. Directly compatible with ZK’s biometric reader controllers. Easy-to-use and intuitive programming with ZKAccess Software System management by browser from client PC’s. No need to install software on each client Programming of special logic between doors is set up with simple pull down menus. No special scripts or code is required. Management software allows indication of real-time door status and remote commanding of door open/close state. Alarm conditions such as forced open and extended open alarms are reported Advanced access control capabilities are built into the hardware, including anti-passback, Dual and multi-Card Authentication, and Duress Mode. MAKE: ZKTECO
Supply and Installation of F16 IP65 Rated Outdoor Fingerprint Access Control TerminalF16 is a fingerprint access control terminal with an integrated proximity reader (EM),It is IP65 rated which enables it to be resistant from water, dust and other outside damages,It can be installed easily on your network having both Ethernet and RS485 serial ports
Supply and Installation of Desktop Software for Access Control & Time Attendance System 1 Year Software License
Supply and Installation of Proximity Card
Supply and laying of PVC 1" Pipe With Accessories.
Supply and demonstration of 5 KVA Automatic On line UPS with input Voltage range 180V -260V and output Voltage 200V-230V 50HZ with micro controller based design like microtek/ equivalent with 10 Nos 12V -100AH Exide battery/ equivalent and testing complete.
Supply, Installation, Testing, Commissioning and Handing over of 50 KWp of Grid connected roof top Solar PV Systems Scheme complete as detailed below. Design, Engineering, Manufacturing, Procurement, Supply of materials to project site, project management, installation of mechanical equipment, cabling & appurtenances, instrumentation and electrical system and other equipment, as detailed in this section. Scope of the proposal a)Solar Modules (Multicrystalline-as per IEC specifications) b)Mounting Structure (Design to Pudukkotai ambient condition) c) Inverter, distribution boards, junction boxes, cables d) Earthing for Solar modules and inverter e)Lightning Protection f) Installation and commissioning g)Project management h)Liasioning for approval from MNRE TECHNICAL SPECIFICATIONS 1. SOLAR PV MODULES AND ARRAY (i) Only indigenous modules shall be used in the Solar module shall be Poly Crystalline (or) Concentrator PV modules type. The peak power output of the PV Module shall be min 100Wp under STC. Module Voc shall be minimum 21V. The total array capacity shall not be less than required capacity and this shall be operating at the required DC voltage. The power output of the PV module must be reported under standard test conditions (STC). 315 watt modules 64 nos 72 Cells with Voc 45.6V and 9.01 IMP I_V curve of the sample module should be submitted.
(v) PV modules must also qualify Salt Mist Corrosion Testing as per IEC 61701/IS61701. (vi) SPV modules shall be certified by NABL/IECQ accredited test centre. The bidder shall submit appropriate certificates. (vii) Protective devices against surges at the PV module shall be provided. Low voltage drop bypass diodes shall be provided. (viii) Module Junction box (weather proof), where the module terminals shall be interconnected and output taken, shall be designed for long life out door operation in harsh environment as per the relevant BIS specifications and protected against surges. It should have a provision for "Opening" for replacing the cable, if required. (ix) PV modules used in solar power plants must be warranted for output wattage, which should not be less than 90% at the end of 10 years and80% at the end of 25 years. (x) Each PV module must use a RF identification tag (RFID), which must contain the following information: a.Name of the manufacturer of PV Module b.Name of the manufacturer of Solar cells c.Unique Serial Number & Model No. of the module d.Month and year of the manufacture (separately for Solar cells and module) e.Country of origin ( separately for solar cells and module) f..I-V curve for the module g.Peak Wattage of the module ,Im, Vm and FF for the module h. Date and year of obtaining IEC PV module qualification certificate
i. Name of the test lab issuing IEC certificate j. Other relevant information on traceability of solar cells and module as per ISO 9000 series RFID shall be mandatorily placed inside the module laminate. A distinctive serial number starting with NSM will be engraved on the frame of the module or screen printed on the tedlar sheet of the module. 1.1 ORIENTATION AND TILT OF PV MODULES Modules shall be North -South oriented at the Tilt Angle of 11° "13° 2. MOUNTING STRUCTURES The PV modules will be mounted on fixed metallic structures of adequate strength and appropriate design, which can withstand load of modules and high wind velocities up to 150 km per hour. The support structure used in the power plants will be hot dip Galvanized Iron (G.I). The "Mounting Structure" should have the following features: •The modules support structure shall be Mild Steel /hot dipped Galvanized (atleast 120 micron) Iron for holding the PV modules. The size of angle iron should not be less than 50x50x5mm.Each panel frame structure shall be so fabricated as to be grouted on roof on its legs. The legs of the structure shall be fixed and grouted in the PCC foundation column made with 1:2:4 cement concrete. The foundation shall support SPV modules at a given orientation, absorb and transfer the mechanical
loads to the ground properly and shall withstand maximum wind speed of 150 km/hr. All nuts and bolts should be made of good quality Stainless Steel. The structure should be designed to allow easy replacement of any module. The array structure shall be so designed that it will occupy minimum space without sacrificing the output from the SPV panels.The minimum clearance of the lowest part of the module structure and the developed ground level shall not be less than 500 mm. The minimum clearance required from the parapet wall of the roof & in between row of panels is min 2 feet for cleaning the panels & servicing. The bidder shall specify installation details of the PV modules and the support structures with appropriate diagrams and drawings. The workshall be carried out as per the designs approved by the procuring entity. 3. JUNCTION BOXES The junction boxes shall be dust proof, vermin and waterproof and made of FRP / Thermo Plastic. The terminals shall be connected to copper bus bar arrangement of proper sizes. The junction boxes shall have suitable cable entry points fitted with cable glands of appropriate sizes for both incoming and outgoing cables. Suitable markings shall be provided on the bus bar for easy identification and cable ferrules shall be fitted at the cable termination points for identification. Each main junction box shall be fitted with appropriate rating blocking diode. The junction boxes shall be of reputed make. 4. POWER CONDITIONING UNIT (PCU) The PCU shall also house MPPT (Maximum Power Point Tracker), an interface between Solar PV array & the Inverter, to maximize Solar PV array energy input into the System. PCU including MPPT & protection
conform to IEC 61683/IS 61683, IEC 60068-2(1,2,14,30)/Equivalent BIS Std., DETAILED SPECIFICATION 1) DC Array Input Operating Voltage -20% to +15% of the DC Array input voltage in Sl. No. 1 above 2) Type of Solar Charge Controller MPPT Based Solar Charge Controller 3) Switching device MOSFET/IGBT based 4) Output Wave Form Pure Sine Wave Output 5) Total Harmonic Distortion < 3% with resistive load 6) Output Voltage 230+ 3 % in case of 1 phase PCU 400+ 3 % in case of 3 phase PCU 7) Output Frequency 50 Hz. ± 0.5 Hz. 8) Power Factor > 0.9 9) PCU efficiency > 90% at nominal voltage & power 10) Idle Current < 4% of rated capacity 11) Regulation Line regulation & Load regulation - 2 % 12) Overload Features 150% for 1 minute 13) Cooling Forced Air cooling, with temperature controlled cooling fan 14) Operating temperature 0 - 50 °C 15) Relative Humidity 95% Maximum
16) LED /LCD Display : Indications Display shall indicate system functional parameters and protection functional indicator 17) Data monitor and display controls RS485, Ethernet OR RS232 connectivity 18) Protections: 1) Input over voltage 2) Low/high frequency 3) Short circuit 4) Under/over output voltage 5) Over Temperature 6) Grid Input under voltage / over voltage with auto recovery 7) DC disconnect device 8) DC reverse polarity 9) Anti Islanding Protection as per the standard 19) Enclosure Protection IP 21 (for indoor) as per IEC 529 20) Safety 1. IEC 62103 2. IEC 62109 Part 1 & 2 3. Galvanic Isolation at input & output through transformer INVERTER: The power conditioning unit/inverter should be grid interactive and also DG set interactive if necessary. Inverter output should be compatible with the grid frequency. Nominal AC O/P voltage and frequency : 415V, 3-ph, 50Hz Accuracy of AC voltage control Output frequency : +1% Output frequency : 50 Hz Accuracy of frequency control : +0.1% Grid Frequency Synchronization range : +3Hz
Maximum Input DC Voltage : inverter Dependant Ambient temperature considered : 40˚C Humidity : 95% Non condensing Protection of Enclosure : IP- 20(Min) Indoor. IP-65(Min) Outdoor Grid Frequency Tolerance range : +3% Grid Voltage tolerance : -20% & +15% No-load losses : <1% of rated power Inverter efficiency(minimum) : >95% THD : <3% 5.DC & AC Switches a. DC SIDE (i) MCB of suitable rating shall be provided for connection and disconnection of array & PCU for maintenance purpose. (ii) Switches and Circuit Breakers on DC side shall be DC rated or they shall be sufficiently de-rated, if AC rated switches are used. b.AC SIDE MCB of suitable rating shall be provided for connection and disconnection of PCU & load All the cables shall be supplied conforming to IEC 60227/IS 694 & IEC 60502/IS 1554 shall be of 1.1 kV grade as per requirement. Only PVC copper cables shall be used. The size of the cables between array
protection. In addition to disconnection from the gird (islanding protection i.e. on no supply), under and over voltage conditions will adequate rating fuses, fuses on inverter input side (DC) as well as output side (AC) for overload and short circuit protection and disconnecting switches to isolate the DC and AC system for maintenances as needed. Fuses of adequate rating will also be provided in each solar array module to protect them against short circuit. A manual disconnect 4 pole isolation switch beside automatic disconnection to grid would have to be provided at utility end to isolate the grid connection by the utility personal to carry out any maintenance. 10.OPERATION AND MAINTENANCE MANUAL An Operation and Maintenance Manual, in English and Tamil, should be provided with the solar PV power plants. The following minimum details must be provided in the Manual: About Photo Voltaic & PV Module Clear instructions about mounting of PV module. About electronics used in DO's and DONT's, Trouble Shooting of the power plants. Name & address of the person or Centre to be contacted in case of failure or complaint.
The equipment/materials and the whole system should be operated by trained personnel of the purchaser after giving training. The periodical maintenance, cleaning of the Solar Panels should be done by the firm/Supplier/Contractor for a period of five years. 11.Grid – Tie Solar PV System i)Solar PV Modules ii)Structure for mounting modules iii)Inverters iv)Cabling to PV module to Inverter (a)Bench mark cost (MNRE) Rs. 100/per wattp (b)MNRE Subsidy: 30% (c)Cabling for grid interaction (d)Segregation of mains (e)Installation and Commissioning (f)Periodical inspection, cleaning of panels and maintenance of the system for five years 12.WARRANTY (i) Solar panel at 90% efficiency - 10 years (ii)Solar panel at 80% efficiency - 25 years (iii)All other equipments - 5 years WARRANTIES & GUARANTIEES: The goods supplied under this contract are new, unused, of the most recent or latest technology and incorporate all recent improvements in design and materials. This warrantee will also be covering the rectification of any and all defects in the design of equipment, materials and workmanship including spare parts for the guarantee period specified by
MNRE/ TEDA from the date of commissioning. All the Guarantees / Warrantees of the different components will be transferred to Owner of the project. 13. Make of the Components (i) Indigenous MNRE approved Multi Crystalline modules – Tata Power / Emvee / HHV / ORB / Renewsys / Equivalent. (ii) ON grid Inverter (PCU) –GrowWatt / K-Solarie / JFA / Polycab / Delta / Kirloskar / Zaver / ABB / Equivalent.
Supply and Clamping of 3.5 X 150 sq.mm PVC LTUG Armed Aluminium Cable on wall with MS clamp.
Supply and fixing of brass cable gland for 3 ½ x 150 sq.mm PVC armoured LTUG Cable with earth connection.
Supply and Providing cable end termination for 3 ½ x 150 sq.mm PVC LTUG alu armoured Cable with necessary alu cable sockets by crimping etc with earth connection complete.
Power Manager cum Total Generation Meter IBox with iPLON_IoT and 24V Power supply - 1 no. with Modbus Converter (RS 485 to TCP/IP) - 2 Ports. PV-DG controller setup logics and Inverter power control simulation Wifi Router (placed outside iBox) - 1 no. 5 Port Ethernet Switch - 1 no. Build in IP55 Hensel Box: Ready with all terminals -1 no. Accessories (SPD, TBs, Ferrule etc), Configuration of MFM Meters,Router setup Arrangements to get Net Feed In with TNEB in HT service includes Cat/ RS485 Cable , Gross Production reading arrangement as per TNEB NCS wing /TNRC Guidelines.
3 Phase multifunctional Energy Meter Must asses the Voltage / ampere range of the TNEB power supply through suitable I.T/CT coil to be fixed in the main power panel Bus bar and communicate the same to the Solar Log Equipment.
Control Panel Suitable MS Box with indication lamps with wire connections for 3 Phase and suitable for fixing the Solar log Equipment and the multifunctional Energy meter.
CT Coil Suitable CT coil for to measure the current in the Main in coming cable in the MV Panel and in Generators.
UPS Supply 800VA Ups with maintenance free Li ferrous Oxide Battery with 90% Efficiency and 4 years warrenty for to ensure uninterrupted supply for the Total device to work even in power cut times.
Supply and laying of 2x2.5 sq.mm cu .wire in PVC pipe between zero export device and the Solar panel invertors.
Supply and laying of Lan cable between the solar invertors and the existing WIFI arrangement with Net connection.
CEIG Inspection Provision for Electrical Safty Certificate CEIG Inspection (preparation of application drawing, Paying fees and getting approval from TANGEDCO for connecting the two ON Grid systems).
Net feed in meter Paying all estimate charges to Tangedco for getting netfeed in meter for the existing solar power plant as per the directions given in the NFR Order received from NCES wing.
Charges payable to TANGEDCO. (For Solar Meter)
Supply and fixing of Sub Meter Board suitable for 3 Phases 200A service connection made up of suitable angle iron frame work of size 2 feet x 1 1/2 feet using angle iron of size 1 1/2" x 1 1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1 1/2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos 200A fuse units (500V) 1 No. Neutral link, copper earth flat of size 1" x 1/4" with inter connection of Sub meter to fuse units by 19/16 PVC insulated copper wire with earth connection complete with 200 Amps watt hour meter.
Supply and fixing of Sub meter board suitable for 32A single phase service connection with 32A fuse unit (500V) 32A neutral link and earth link (1" x 1/8" copper flat) on TW plank of size 375mm x 300mm x 19mm with supporting TW reepers of 1" thick an either side with painting with suitable bolt and nuts for fixing the TW plank on wall with earth connection and inter connection with 7/20 PVC insulated copper wire from EB meter to fuse unit with 10 Amps Single phase watt hour meter.
Supply of 16M high mast shaft in two sections suitable for 50/47/44/39m/sec wind speed, with raising lowering system comprising, head frame, luminaries carriage suitable to install 8 nos luminaries in symmetrical arrangement, double drum winch, 6mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightening finial. Wiring material, power cables between panel and mast, MCB in base compartment, CG mounting clamps and bolts, luminary mounting bolts are not included.
Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and template.
Supply of Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium non integral IP66 flood light, suitable for high mast application, highlighting architectural facade and general purpose lighting. (Havels make : JETA VALOURFL240W LED757MODNBLT G and ASSEMBLED CGBOXVALOUR240WAP
Supply of Single dome aviation obstruction lights of type LED.
Supply of outdoor stand mounted feeder pillar with 32A TPN MCB incomer, Double dial time switch, 63A TP contactor for the automatic switching of luminaries, power tool control with 2 no 9A contactors and raise lower push button, Incoming 35 sq. mm and out going 16 & 2.5 sq. mm terminals.
Construction of shallow foundation with M25 grade concrete for the high mast considering the safe soil bearing capacity at site as 10 T / sq.mtr at 2 metre depth with all materials and labour.
Erection of the high mast with the help of suitable tools and plants, wiring of luminaries with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all labour.
Installation of the mast feeder pillar by grouting the stand in concrete.
Supply and Installation of 6’x8’ Motorized High Gain Glass Beaded Projection Screen with Remote control. Make: Liberty or equivalent.
Supply and installation of Delegate Discussion Unit with Removable Microphone: Modern, sleek, and contemporary design, Removable microphone connector, Digital signal processing, Shielded microphone, immune to mobile phone interference, High-quality integrated loudspeaker, Headphone output, Headphone volume adjustment, Microphone On/Off button. Make: Televic, Model: D-CernoDSL+D-MIC40SL
Supply and installation of Chairman Discussion Unit with Removable Microphone: Modern, sleek, and contemporary design, Removable microphone connector, Digital signal processing, Shielded microphone, immune to mobile phone interference, High-quality integrated loudspeaker, Headphone output, Headphone volume adjustment, Microphone On/Off button,. Make: Televic, Model: D-CernoCSL+D-MIC40SL
Supply and installation of Conference Control Unit with Recording & Web Server : Contemporary design fits in everywhere, Fan-less operation guarantees silence, Energy-efficient, Plug-and-play approach, Easy browser-based configuration, Camera control integration capabilities, Touch sensor button technology, Digital signal processing, Integrated web server, Integrated Recording. Make : Televic Model: D-CernoCUR.
Supply and laying of Connection cable, 20m, black.
Supply and installation of Wireless Handled Microphone. Make :Studio Master Model :XR 100
Supply and installation of 5"ICT Surface-Mount Loudspeaker for Installation Applications, 50W@ 16 Ohms, 70 V/100V: 30 W / 15 W / 7.5 W, IP65 rating,Yoke bracket included (White). Make: Tannoy. Model: AMS5ICT.
Supply and installation of 2 Channel 2X240 Watt Commercial Amplifier with Energy Star Certification, 240 W output per channel into 8,4,Ohms and 70V. Make: Labgruppen, Model : CA2402.
Supply & Installation of 12 Audio Mixing Console. Make : Sound craft / EPM12
Supply & Installation of Professional Ultra-low noise 8 in 2 out line mixer and 2 in 8 out line splitter, 6 mono in, 6 mono out, 2 main inputs and 2 outputs, 4/8-segment input/output level meters for all channels. Make: Behringer, Model: Ultralink Pro MX882
Supply and Installation of Super cardiod Handled microphone. Make: SHURE Model: Beeta 58A
Supply and laying of 2 core shelded pure copper belden microphone cable.
Supply and installation of Wireless Handled Microphone. Make : AKG.Model :Mini40
Supply and Installation of 17U floor standing heavy duty audio rack with power sockets and lock and key facilities. Make: Avalon/Equivalent
Testing and commissioning charges for the above work including necessary cables XLR M & F jacks, Phono, RCA, E pin stereo jack etc.
Supply and Installation of 4K full HD speaker tracking with 12x optical 12x digital zoom, full view EPTZ camera, auto framing participants, echo cancellation ,USB video conferencing camera. Make: Panasonic. Model:KX-VDW200SX.
Supply and Installation of Wireless Bluetooth omnidirectional USB conference microphone with speaker for echo cancellation, noise reduction, 3 meter radial mic pickup range. Make: Panasonic. Model :KX-VDW320SX.
Supply and installation of 5 mtrs 4K HDMI cable. Make : Honeywell
Supply and installation of 5.1 USB printer cable 5 meters.
Supply and installation of camera holding stand.
Renewal by supply and installation of SONY 75 inch 4K UHD, Speaker 10W+10W, USB, HDMI, Audio Jack, RS232, RJ45, 350 nits, Display color 16.7M, Response time 6ms (Typ), Contrast Ratio 4000 to 1, High Temperature Sensor, 24/7 operation with 3 years warranty with stand. Make: SONY Model: X90 K
CMK Projects Private Ltd., (BID ID -1112385)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid