Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 CrAccepted-AOC | ₹4.7 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹4.7 Cr+₹4.6 L (0.98%)Rejected-AOC | ₹4.7 Cr+₹4.6 L (0.98%) | L2 | Rejected-AOC Other than lowest |
| 3 | L3₹5.3 Cr+₹57.3 L (12.2%)Rejected-AOC | ₹5.3 Cr+₹57.3 L (12.2%) | L3 | Rejected-AOC Other than lowest |
| 4 | L4₹6.0 Cr+₹1.3 Cr (27.7%)Rejected-AOC JAISALMER RAJASTHAN 345001 INDIA UDYAM RJ 18 0001538 | JAISALMER | RAJASTHAN | 345001 | ₹6.0 Cr+₹1.3 Cr (27.7%) | L4 | Rejected-AOC Other than lowest |
| 5 | L5₹6.4 Cr+₹1.7 Cr (36.5%)Rejected-AOC | ₹6.4 Cr+₹1.7 Cr (36.5%) | L5 | Rejected-AOC Other than lowest |
Tender Value
Refer Docs
EMD Value
₹5.0 L
Closing Date
23 Dec 2020, 6:00 pmClosed
Chief Engineer 31 Zone
HQ Chief Engineer 31 Zone PIN914631 c/o 56 APO
PROVN OF KLP FOR CERTAIN UNITS WITH ALLIED INFRA AT SONAMARG (PHASE-I OF TWO PHASES)
2019_MES_289246_2
CESZ- /2019-20
Open Tender
Civil Works
Lump-sum
1295 days
Sonamarg
As per NIT
6 documents required · 6 mandatory
₹2,000
Yes
GE 970 EWS
₹5.0 L
Yes
1 Jan 2021
1 Dec 2020
25 Dec 2020
1 Dec 2020
23 Dec 2020
5 Dec 2020
1 Dec 2020 - 16 Dec 2020
Amount
Note: (i) Please refer Schedule 'A' Notes given on serial page No. 21 to 28 of tender documents. (ii) Item from Srl No. 3 to 7 of this document shall be Part-XII (Miscellaneous items) of BOQ (iii) Unless otherwise specified, earth work and excavation shall be measured and paid separately for item No 3 to 7 of BOQ (iv) This schedule 'A' Part-XII (Miscellaneous items) is not estimated by MES and the estimated rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule 'A' Part-I brought forward from serial page No. 29.
Lump sum price worked out by the contractor for INTERNAL ELECTRIC SUPPLY WORKS as listed in Schedule 'A' Part-II brought forward from serial page No. 31
Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-III brought forward from serial page No. 33
Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS listed in Schedule 'A' Part-IV brought forward from serial page No. 35
Lump sum price worked out by the contractor for ROAD, PATH & CULVERT WORKS as listed in Schedule 'A' Part-V brought forward from serial page No. 36
Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule 'A' Part-VI brought forward from serial page No. 37
Lump sum price worked out by the contractor for FENCING & GATE WORKS as listed in Schedule 'A' Part-VII brought forward from serial page No. 39
Lump sum price worked out by the contractor for PROTECTIVE WORKS as listed in Schedule 'A' Part-VIII brought forward from serial page No. 41
Lump sum price worked out by the contractor for SITE CLEARANCE & EARTHWORKS as listed in Schedule 'A' Part-IX brought forward from serial page No. 42.
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule 'A' Part-X brought forward from serial page No. 46
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule 'A' Part-XI brought forward from serial page No. 48
INTERNAL ELECTRIFICATION WORKS
LED bulb of capacity 9 watts lumen out put (500) length 102mm dia 56mm base cap B22, (ISI marked) complete with all accessories base (ISI marked) all as specified & directed by Engr-in-charge. Make : Bajaj/Philips or its equivalent.
LED tube light 18 watts with high transmissitivity diffuser and high lumen output, PF>0.98, energy efficient all as specified and as directed by Engineer-in-charge. Make : Havells/Bajaj/Philips/CG.
LED Mirror light/rechargeable light 6 watt with frosted PVC cover and pull chord including Li-ion battery 3.7V, 2000 MAH (ISI marked) all as specified. Make : Bajaj/CG/Wipro/Havells
MCBs single pole and neutral (SPN) 40 Amps with 10 KA breaking capacity of 'B' series in distribution boards (ISI marked) complete all as specified and directed.
MCBs single pole (SP) 6-32 amps with 10 KA breaking capacity of 'B' series in distribution boards (ISI marked) complete all as specified and directed.
MCBs single pole (SP) 0.5 to 6 Amps with 10 KA breaking capacity of 'B' series in distribution boards (ISI marked) complete all as specified and directed.
Heavy duty exhaust fan of size 300mm sweep, AC single phase 220 volts 50Hs, 1500 RPM incl louver shutter, XPM jaali, grouting etc. (ISI marked) complete all as specified and directed. Make : Havells/Bajaj/Usha/CG/Khaitan.
Ceiling fans 1200mm sweep BEE 5 star rated single phase AC 220 volts 50 Hz aluminium body, copper wound with fan blade aluminium, three core copper wire lead, electronic type regulator (rotary type 360 degree) (ISI marked) complete alll as specified and directed. Make : Havells/Bajaj/Usha/CG.
LED street light fitting 20 Watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment with IP 66 ptotection and impact resistance of IK07 (ISI marked) complete all as specified and directed. Make : Havells Cat Part No ENDURAPEARLSL20WLED757SASYTOPC or equivalent in Wipro/CG/Bajaj.
'Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x6 mm thick burried directly in gound (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to galvanised iron earth lead 4mm dia by means of bolt, nuts check nuts and washers of galvanised iron and 4 mm dia GI earth wire protected by provn of GI medium grade pipe 15mm bore upto 7.5mtr including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (Weight not less than 4kg/Sqm) and frame of angle iron 25x 25 x 3mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of Bronze/Gun metal with fixing arrangement, funnel, wire mesh and excavation/earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50 metre, all as per electrical plate No 3 of SSR -2010 Part -I and connecting to earth test point all as specified or indicated including testing on completion, complete all as specified and directed. Note : The quoted rate of earthing shall be deemed to include cost of 7.5 m long galvanised wire 4 mm dia and protection pipe 15 mm bore medium grade GI light grade 20 mm bore watering pipe. Any variation in length shall be adjusted through deviation order based on SSR rates adjusted with quoted rates.
Supply, installation & connecting & installed water heater storage type (Geyser) of 25 ltrs capacity complete including grouting of bolts four nos for fixing of geysers complete all as specified and directed; Make :- Havells /Venus/Bajaj/Racold
Exhaust fan of size 230 mm sweep, AC single phase, 220 volt 50 Hz 1500 RPM (ISI marked) complete all as specified and directed.
MCB’s SPN 63 Amps with 10 KA breading capacity of ‘B’ series in distribution boards (ISI marked) complete all as specified and directed.
PVC connection 15mm with PTMT nut of length 450mm complete all as specified and directed.
INTERNAL WATER SUPPLY WORKS
Angle valve cast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for 15mm bore iron pipe or for unions and fixed complete all as specified and directed.
SEWAGE DISPOSAL WORKS
Construction of RCC septic tank for 50 user with upflow filter designed to carry sewage and sludge water, including excavation and earth work in any type of soil, PCC 1:4:8 below foundation, RCC M-30 design Mix in walls, Base Slab, Baffle walls and roof slab including beams etc with vent shaft, manhole openings with cover connection etc, complete with effective depth of 1.5 metre and overall depth of 3 metre, complete all as specified and directed.
LLDPE septic drainage tank with upflow filter including media designed to carry sewage and sludge water, excavation in any type of soil, PCC 1:4:8 below foundation, vent shaft, connection etc, complete for 25 users LLDPE tank (commercial grade) as per manufacturer's instructions of Make sintex/polywell/Rotex/Polycon, complete all as specified.
Construction of Soakage well including excavation and earth work, in any type of soil, foundation in PCC 1:3:6 wall of honey combed masonry with top ring of M-30 (Design mix) concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.6 M dia x 4.5 M effective depth (Ref TD ND CESZ/TD-1078/2011) complete all as specified.
Construction of Soakage well including excavation and earth work, in any type of soil, foundation in PCC 1:3:6 wall of honey combed masonry with top ring of M-30 (Design mix) concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3.0 M dia x 4.5 M effective depth (Ref TD ND CESZ/TD-1078/2011) complete all as specified.
EXTERNAL ELECTRIC SUPPLY WORKS
Sand cushioning with a layer of fine sand 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified. Notes: (i) Excavation and earth work to be measured and paid for separately. (ii) Measurement shall be taken only after punning down sand cushioning.
Supply and laying brick common burnt sub class ‘B’ old size for protection of cable laid in trenches laid flat for underground cable all as specified. Note:-Excavation and earth work to be measured and paid for separately.
Supplying, transporting to site, erecting and fixing in position, 11 mtr long and type 410 SP-55 steel tubular swaged and welded poles, ISI marked with with cast iron base plate, finial taper plug, bolts, nuts, washers & screws etc as specified complete, including painting outside with two coats of aluminium paint over a coat or red oxide primer on exposed surfaces and black bituminous paint on steel surface embedded in concrete complete all as specified and directed.
PCC HT cable route indicators of size 300 x 500 x 40mm duly embossed HT cable/LT cable including PCC foundation complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of the earth plate at a depth not less than 1.25 metre below ground level, earth plate surrounded by 15cm thick and packed with layers of charcoal dust and common salt, earth electrode GI strip 25 x 4 mm dia connected to GI earth plate electrode by means of bolts, nuts, check nuts and washers of galvanized iron and thimbles and other end of earth wire connected to main switch board and protected by galvanized iron light grade 40mm bore and GI pipe 20mm bore medium grade with funnel and wire mesh for watering including necessary excavation and earth works. PCC chamber in cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) with 40mm thick RCC cover in M-30 (Design Mix) reinforced with XPM (weight not less than 4 kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 02 Nos and all as shown in Electrical Plate No. 3 of SSR (Part-1)of 2009. all as specified. Notes:- (i) Main earthing strip from earth plate electrode to rest point upto length of 7.5 meters length shall deemed to be included in the unit rate quoted against this item. (ii) On testing after completion if the desired resistance is not obtained the contractor shall redo the earthing without any extra cost to the department.
Earthing complete with galvanized iron or steel earth plate electrode 60cm x 60cm x 6.00 mm thick buried directly in ground (earth pit not less than 2.25 Mtrs below ground level) with top edge of earth plate not less than 1.5 Mtrs below ground level connected to galvanised earth lead wire 4mm dia by means of nuts, bolts, thimbles, check nuts, washers of GI or steel, including PCC (concrete chamber) shall be PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate), with fair finish. Internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire gauge of (0.68mm) 8 mesh per liner inch, 80 mm thick RCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering pipe shall be 20mm bore medium grade GI pipe, and including all excavation and earth work & connecting the earthing to an earthing test point /transformer neutral/body/ LT panel etc. and testing on completion, complete all as specified & directed. Note : (i) The quoted rate of earthing shall be deemed to include cost of 7.5 m long galvanised wire 4 mm dia and protection pipe 15 mm bore medium grade GI light grade 20 mm bore watering pipe. (ii) On testing after compeltion if the desired resistance is not obtained the contractor shall redo the earthing without any extra cost to the department all as specified
Platform for transformer of size 2500 x 2000 x 1200 mm (1.2 m above ground level) with block construction in cement motar 1:4 PCC M-10 (nominal mix) in floor, brick step on one side including fixing XPM jalli all around on angle iron 50 x 50x 6mm post and gate openable type with locking arrangement and top roof shed including earth work in any type of soil. Metal work to be painted with two coats of synthetic enamelled paint over a coat of red oxide primer complete at as specified.
Supply, installing, testing & commissioning of CPRI approved LT panel board, outdoor type, cubical, dust and vermin proof made out of 3.15 mm thickness MS sheet with front and back door openable type fitted with nuts, bolts and washers fitted with knobs and hinges and air vents including painting with two coats of enamelled paint over a coat of red oxide primer, suitable for 415 V , 50 Hz, 3 phase, 4 wire suitable for and including the following (Distribution panel No-01) :- (a) MCCB FP 125 Amps 36 KA- 01 No (Incoming) (b) MCB DP 32Amps - 02 Nos (c) MCCB FP 32 Amps 16 KA - 01 No (d) MCCB FP 25 Amps 16 KA - 01 No (e) Digital voltmeter 0-200 volt -01 No (f) Digital Ameter with CT 0-200 Amps-01 No (g) LED indicator lamp-03 Nos (h) Copper bus bar chamber of capacity with bus bar 200 Amps TPN with bus bar insulator-01 No. (Including one free space for future expension of MCCB 32 Amps) (j) Internal wiring with suitable size single core copper conductor cable of Red, Yellow, Blue and black colour including lugs, ferrule, tag etc.
EXTERNAL WATER SUPPLY WORKS
Non return valve//Reflux valve ISI marked of rating PN 1.6 ISI marked 100 mm bore complete with nuts,bolts and washers complete all as specified.
Cast iron sluice valve long body ISI marked both end flanged Class PN 1.6 ISI marked for 80 mm bore pipe with brass spindle ISI marked complete with hand wheel joints, jointing material rubber insertion sheet 3mm thick bolts,nuts,washers etc complete all as specified.
Air release valve with two air release outlets of size 100mm bore pipe flanged type with 3mm thick rubber gasket MS bolts,nuts,washers etc complete all as specified.
Air release valve with two air release outlets of size 80mm bore pipe flanged type with 3mm thick rubber gasket MS bolts,nuts,washers etc complete all as specified.
Construction of brick masonry valve pit of size 90cm x 90cm x 100cm (internal size) with mild steel sheet cover 3.15mm thick and frame of angle iron of size 40x40x 6mm duly all exposed surfaces painted with two coats of synthetic enamel paint over a coat of red oxide primer and painting all embedded MS surfaces with two coats of black bitumenous paint including excavation and earth work,150mm thick PCC (1:4:8) type D-2 as in foundation,brick work in cement mortar (1:6),locking arrangement, and all inner size of pit shall be plastered 15mm thick using cement mortar (1:4) and coping in PCC (1:2:4) type B-1 over brick wall complete all as specified and shown on drawings.
All as per item No. 7.05 but size 90cm x 90cm x 90cm.
Supply and laying rubber matting electrical grade 12.5mm thick chequered too, ISI marked laid in front of the LT panel all as specified and directed of dimensions 0.9mtrx1.8mtr. complete all as specified.
Supply, installation, testing and commissioning submersible DOL horizontal type electrical submersible pump set 3 phase, 415 Volt having capacity of pumping water at the height of 25 mtr and discharge rating 4 LPS mounted on MS commom base frame motor having copper wound class F complete all as specified and directed including following:- (a) Provn of necessary PCC foundation/MS bracket for fixing the above pump set as per OEM recommendations including provn of new nuts, bolts and washer arrangement complete. (b) Provn of S/S strainer in the inner side
Submersible cable PVC insulated, multi stranded, copper conductor 3 core, 4 Sqmm flat, 1100 volt grade incld necessary water proof joint,lugs and fixing saddles from starter to pump set drawn through and including PVC conduit of suitable size complete all as specified and directed.
Online submersible DOL starter suitable for 3 to 5 HP submersible motor in sheet steel enclosure having accessories such as voltmeter,ammeter, indication lamp, push button ON-OFF switch, over load relay including fixing clamps fixed on wall complete all as specified
M/S SYED NOORULLAH RIZVI
M/S VALLEY ENTERPRISES CONSTRUCTION CO
RAMESH AND CO
M/S KASHCON CONSTRUCTION CO
M/s Hafizullah Beigh
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .