Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.9 LAccepted-AOC 67 AASANI BAS PALANA PALANA BIKANER BIKANER RAJASTHAN 334402 UDYAM RJ 08 0063520 | BIKANER | RAJASTHAN | 334402 | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹28.9 L+₹1.4 L (5.09%)Rejected-Finance 13 218 MASJID EXTEN SADAR BAZAR | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹35.1 L+₹7.7 L (27.8%)Rejected-Finance | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹38.6 L+₹11.2 L (40.6%)Rejected-Finance | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹46.9 L+₹19.4 L (70.5%)Rejected-Finance | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
₹44.3 L
EMD Value
₹88,500
Closing Date
10 Nov 2021, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
REPAIR/ REPLACEMENT OF SUMMER/ WINTER APPLIANCES OLD/ UNSERVICEABLE WIRING AND CONNECTED ITEMS AT YOGENDER VIHAR BANA SINGH ENCLAVE 180 ORS MAHIPALPUR 35 INF BDE 18 MADRAS 5/11 GR AND 227 FD WKSP UNDER AGE E/M (S) OF GE (SOUTH) DELHI CANTT-10
2021_MES_481693_1
GE/DS-64/2021-22
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹88,500
Yes
8 Dec 2021
13 Oct 2021
12 Nov 2021
13 Oct 2021
10 Nov 2021
27 Oct 2021
14 Oct 2021 - 25 Oct 2021
Amount
Taking down carefully the old U/S Aluminium / Copper point wiring (light, fan, socket or power) including fitting and fixtures (switch, socket, bell push, lamp holder, electric bell, ceiling rose, fan regulator) and making good disturbed surfaces of walls including necessary touch up with the adjoining surface of disturbed area ie with OBD/colour wash/white wash as the existing finish complete all as specified and directed by Engineer-in-charge.
M&L for point wiring complete, stranded copper conductor 1.5 Sqmm nominal area PVC insulated FRLS 1100 volts grade electrical cable in but with through existing concealed PVC/ MS conduit and including replacement of unserviceable pressed steel terminal boxes of required size with top cover 3 mm thick plastic/laminated sheet of required color with screwed and cup washer with all accessories including 1.5 sqmm stranded copper conductor PVC unsheathed cable earth wire to common earth and connected to earth dolly complete all as specified for One light/Fan/Bell point controlled by one switch 5 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing). Note No. 1. Making good to disturbed surface of walls including necessary touch up with adjoining surface of disturbed area i.e with OBD/colour work/white wash as existing finishes complete all as specified and directed by Engineer-in-charge. 2. In existing conduit wiring new conduit will be added where there is a burnt/blokage/damage to the existing conduit including bends/elbows/tees/Junction boxes.
All as per item No 2 here-in-before but for One 3 pin socket outlet, 5/6 Amps, independent, with cables 1.5 sq. mm size with through existing concealed PVC/MS conduit.
All as per item No 2 here-in-before but for 5 Amp socket outlet on same board.
All as per Item No 2 here-in-before but for one socket outlet 5/15 Amps on Independent board with cables 2.5 sqmm size for phase and neutral and 2.5 Sqmm for earthing.
All as per Item No 2 here-in-before but for one One light controlled by 2-way switches using cable of 1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing
S&F of switch piano flush type 5/6 Amps SP one way complete all as specified and directed by Engineer-in-charge.
S&F of switch piano flush type 5/6 Amps SP two way complete all as specified and directed by Engineer-in-charge.
S&F bell push, flush type 5/6 Amps complete all as specified and directed by Engineer-in-charge.
S&F socket outlet 2-in-1, 5/6 Amps flush mounted 5 pin multi purpose complete all as specified and directed by Engineer-in-charge.
S&F switch piano type 15/16 Amps SP one way complete all as specified and directed by Engineer-in-charge.
S&F universal socket outlet 2-in-1 (multipurpose) 5pin 6/16 Amps flush mounted type complete all as specified and directed by Engineer-in-charge.
S&F 0-4 step type electronic regulators for ceiling fan 1200/1400 mm sweep, 240V complete all as specified and directed by Engineer-in-charge.
S&F Lamp holder Angle/Batten Type bakelite insulated body with back plate suitable for batten fitting complete all as specified and directed by Engineer-in-charge.
S&F LED lamp 12 Watt with LED Bulb complete all as specified and directed by Engineer-in-charge. Make of LED Bulb: Halonix/C&S//Syska/Crompton as approved)
S&F in replacement for decorative wall mounting , Champagne gold finish fixture with plastic body suitable for Led Lamp upto 15 Watt complete all as specified and directed by Engineer-in-charge.
S&F in replacement of Electric bell ding dong any type complete all as specified and directed by Engineer-in-charge.
S&F ceiling rose surface Bakelite 65x25 mm two to three terminals complete all as specified and directed by Engineer-in-charge.
S&F wall mounted LED Integrated batten T5 20Watt -4ft white , 6500K, indoor decorative PVC extruded T5 LED batten- Integrated type in replacement of old unsv existing 36/40Watt FTL fitting any type, complete all as specified and directed by Engineer-in-charge.
S&F wall mounted LED Integrated batten T5 10Watt -2ft white , 6500K, indoor decorative PVC extruded T5 LED batten- Integrated type in replacement of old unsv existing 18/14 watt FTL fitting any type, complete all as specified and directed by Engineer-in-charge.
S&F Surface mounting Round/ Square shaped LED downlighter 6 Watt any type complete with including new fliexble wire as required on site in replacement of old unsv existing ceiling light fitting any type complete all as specified and directed by Engr-in-charge.
S&F LED 10 watt white Bulk head any type complete with including new fliexble wire as required on site in replacement of old unsv existing light fitting of any type complete all as specified and directed by Engineer-in-charge.
S&F in replacement of Recessed/surface mounting 36 watt 2' x 2' flat LED panel fitting with soft light and glare free symetrical ilumination suitable for RCC/POP ceiling supplied with wedge bracket to fix in existing ceiling in replacement of existing old unserviceable CFL fitting any type from ceiling and making good the disturbed surface/POP ceiling area to match and getting electrically connected the fitting with switch board for suitable size of PVC copper wire complete all as specified and directed by Engineer-in-charge.
S&F in replacement of building security light fitting 45W LED 5000K new Powder coated pressure die cast aluminium compact LED Street light suitable for pole dia 40 mm of bracket duly fixed with clamps, nut, bolts & washers etc complete all as specified and directed by Engineer-in-charge. (Make: Halonix HL-R or equivalent in Bajaj/CG/Havells/C&S as approved)
S&F in replacement of VTPN distribution board 4 way double door, for fixing MCCB up to 250 Amps as incommer and MCBs as out goings with metel door and IP 43 Protections complete all as specified and directed by Engineer-in-charge. (Make :Legrand Cat No. 5077 47 or equivalent in L&T/Havells/Indoasian/ Siemens as approved)
S&F in replacement of TPN distribution board 4 way double door, vertical type for fixing TPN up to 100 Amps as incommer and MCBs as out goings with metel door and IP 43 Protections and connecting complete all as specified and directed by Engineer-in-charge. (Make :Legrand Cat No. 5077 47 or equivalent in L&T/Havells/ Indoasian/Siemens as approved)
S&F in replacement of MCCB 3 Pole 415V, 'C' series 160 Amps with breaking capacity 36 KA including providing new lugs & thimbles of required size as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement of MCCB 3 Pole 415V, 'C' series 125 Amps with breaking capacity 36 KA including providing new lugs & thimbles of required size as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCB triple pole 63 Amps 415 volts, 'C' Series 10 KA as per site requirement complete as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-8 Way, 240V with 200 Amp rated busbar complete as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-12 Way, 240V with 200 Amp rated busbar complete as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement of sheet metal enclosures double door for DBs when MCBs to be used SPN-16 Way, 240V with 200 Amp rated busbar complete as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement of MCB SPN 63 Amps 240 volts, 'C' Series 10 KA of any description including providing new lugs & thimbles of required size complete as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement of MCB SPN 40 Amps 240 volts, 'C' Series 10 KA of any description including providing new lugs & thimbles of required size as per site requirement complete all as specified and directed by Engineer-in-charge.
S&F in replacement of MCB SP 63 AMPs C curve complete all as specified and directed by Engineer-in-charge.
S&F in replacement of MCB SP 40 AMPs C curve complete all as specified and directed by Engineer-in-charge.
S&F in replacement of MCB SP 6 to 32 AMPs C curve complete all as specified and directed by Engineer-in-charge.
S&F in replacement of sheet metal enclosures with metal clad plug & socket and MCB SP 20Amps, 240 V complete all as specified and directed by Engineer-in-charge. Make - Legrand / Havell's / C&S
S&F in replacement for submain wiring PVC insulated FRLS single core with stranded copper cable of size 10 Sqmm in 2 runs and 10 Sqmm one run for earth drawing through existing PVC conduit 25 mm dia complete all as specified and directed by Engineer-in-charge. Note:- (a) Two runs of main cable and one run of earth cable all together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
M&L 'in replacement' submain wiring PVC insulated FRLS single core with stranded copper cable of size 6 Sqmm in 2 runs and 6 Sqmm one run for earth drawing through existing PVC conduit 25 mm dia complete all as specified and directed by Engineer-in-charge. Note:- (a) Two runs of main cable and one run of earth cable all together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
Taking down old Submain wiring any type , keeping away from site and M&L for submain wiring PVC insulated FRLS single core with stranded copper cable of size 4 Sqmm in 2 runs and 4 Sqmm one run for earth drawing through existing PVC/MS concealed conduit complete all as specified and directed by Engineer-in-Charge. Note:- (a) Two runs of main cable and one run of earth cable all together shall be considered as one length. (b) New conduit of suitable size with connected fitting will be laid if there is a damage/blockage in existing conduit including making good to disturb surfaces with CM 1:3, same surface finished with the adjoining surface of disturbed area and the rates are inclusive of quoted rates.
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to GI wire 4 mm as earthing lead by means of nut, bolts and check nuts and washers, GI light grade protection pipe 15 mm dia upto 7.5 M, GI watering pipe 20 mm dia medium grade, RCC cover with funnel, excavation in any type of soil, PCC pit charcoal, salt all as shown in electrical plate No 5 of SSR Part I, including earth test point upto panel board including testing on completion complete all as specified and directed by Engineer-in-Charge.
Taking down of ceiling fan/ exhaust fan dismantling of blades, transportation to work shop and carrying out rewinding, transportation to site, reinstallation with required cable and testing complete all as specified and directed by Engineer-in-charge. Note:- Rewinding will be measured and paid under respective item of this Schedule.
M&L for Rewinding of ceiling fan 1200/1400 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush and Shaft where ever required complete all as specified and directed by Engineer-in-charge.
M&L for Rewinding of Exhaust Fan & Wall mounted fan upto 300/450 mm sweep by dismantling of fan motor cutting and removing of burnt windings, cleaning, winding with supper enameled copper wire of superior quality, same gauge of wire, same Nos of turns, provn of insulation paper applying of varnish drying of varnish and assembling of fan including replacement gun metal bush & shaft where ever required complete all as specified and directed by Engineer-in-charge.
S&F in replacement ceiling fan/ Exhaust fan Ball bearing of suitable size & model (as per sample) complete all as specified and directed by Engineer-in-charge. Make:- NBC/ SKF or its equivalent as approved by Engineer-in-charge.
S&F in replacement of fan condenser 2.5 Mfd complete all as specified and directed by Engineer-in-charge. Make :- Epcos/Tibcon/Havells or its equivalent as approved by Engineer-in-charge.
S&F in replacement of fan condenser 3.15 Mfd complete all as specified and directed by Engineer-in-charge. Make :- Epcos/Tibcon/Havells or its equivalent as approved by Engineer-in-charge.
M&L for replacement of exhaust fan blades for size upto 450 mm sweep as per sample complete all as specified and directed by Engineer-in-charge.
M&L for replacement of MS louvers suitable for exhaust fan of sizeupto 450 mm sweep as per sample complete all as specified and directed by Engineer-in-charge.
S&F in replacement ceiling fan holder hook with rubber washer suitable for size 1200/1400 mm ceiling fan as per sample complete all as specified and directed by Engineer-in-charge.
S&F PVC canopy for ceiling fan of size 1200/1400 mm as per sample complete all as specified and directed by Engineer-in-charge.
Taking down geyser 25/35/50 ltrs capacity of any make, opening up complete for inspection descalling by chemical treatment of internal tank , themrostate pipe, base plate assembly carrying out minor repairs including replacement of gaskets testing and refixing in position and making electrical and water connection complete all as specified and directed by Engineer-in-charge.
S&F in replacement heating element 1.5 KW for any make of geyser of 25/35 litres capacity as per sample complete all as specified and directed by Engineer-in-charge. Make Micronking/Theeta/Standard or its equivalent as approved by Engineer-in-charge.
S&F in replacement heating element 2 KW for any make of geyser of 50 litres capacity as per sample complete all as specified and directed by Engineer-in-charge. Make Micronking/Theeta/Standard or its equivalent as approved by Engineer-in-charge.
S&F in replacement thermostat ( 9/11 inch Long) for geyser 25/35/50 ltrs capacity complete all as specified and directed by Engineer-in-charge. Make Micronking/Theeta/ Standard or its equivalent as approved by Engineer-in-charge.
S&F in replacement indicating lamp round / flat type as required for geyser 25/35/ 50 litres capacity as per sample complete all as specified and directed by Engineer-in-charge.
S&F in replacement safety valve ISI marked for geyser 25/35/50 litres capacity as per sample complete all as specified and directed by Engineer-in-charge.
S&F in replacement safety plug for geyser 25/35/50 litres capacity as per sample complete all as specified and directed by Engineer-in-charge.
S&F in replacement PVC connection with brass nipple 15 mm x 450 mm long for hot water for geyser 25/35/50 ltrs capacity as per sample complete all as specified and directed by Engineer-in-charge.
S&F in replacement base plate geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket of 25 litres capacity as per sample complete all as specified and directed by Engineer-in-charge.
S&F in replacement base plate geyser syphon assembly set complete with inlet, outlet and thermostat pipe including rubber gasket of 35/50 litres capacity as per sample complete all as specified and directed by Engineer-in-charge.
S&F in replacement inner stainless steel tank suitable for 25 Ltr storage water heater complete all as specified and directed by Engineer-in-charge.
S&F in replacement inner stainless steel tank suitable for 35 / 50 Ltr storage water heater complete all as specified and directed by Engineer in Charge.
S&F in replacement FR PVC Sheathed Round , Copper conductor (Flexible) industrial cable , 1100 Volts , conforming to IS: 694 of size 2.5 Sqmm 3 core for connecting geyser , complete all as specified and directed by Engineer-in-charge.
S&F in replacement Rubber gasket for Water heater storage type of any capacity as per the existing, complete all as specified and directed by Engineer-in-charge.
S&F in replacement MS fastner bolt 8 mm dia and upto 150mm long for fixing Geyser/Exhaust Fan with nuts and washers complete all as specified and directed by Engineer-in-charge.
S&F in replacement of Metal Clad Socket 240 Volts , 20 Amps, 2P + E, upto 20 Amps capacity of Ovory or blue cap colour complete all as specified and directed by Engr-in-charge. Make - Legrand / Havell's / C&S
S&F in replacement of Metal Clad Plug Top 240 Volts , 20 Amps, 2P + E, upto 20 Amps capacity of Ovory or Grey colour complete all as specified and directed by Engineer-in-charge. Make - Legrand / Havell's / C&S
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
verma enterprises
niranjan singh and company
Microsys Controls India
Surjit and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .