Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
3 Nov 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Kiran Gajrani, IDSE
Commander Works Engineers (AF), Khese Park, Lohegaon, Pune-411032
PROVN OF SIGNAGE BOARDS FOR AIRFIELD AT 2 WG AFS UNDER GE AF LOHEGAON
2026_MES_792918_1
83030/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF Lohegaon
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE AF Lohegaon
₹1.8 L
Yes
8 Oct 2026
8 Oct 2026
10 Nov 2026
8 Oct 2026
3 Nov 2026
29 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and fixing of Single sided Internally illuminated LED based mandatory information/ Guidance Sign Boards of various sizes as cited in Appendix 'B' and depth not less than 150mm made out of 4mm thick glare free polycarbonate sheet at front facia having the required details (letters and symbols) screen printed on self adhesive film of 3M make/equivalent and pasted inside of the polycarbonate sheet and body made of 2mm thick anodised aluminium profile reinforced by 50mm X 50mm Aluminium /Aluminium alloy structure on other five sides with sufficient No. of 50mm dia aluminium legs of 5.5mm thick legs and frangible couplings, uniformly internally illuminated with adequate No of LED Modules of LED of burning hours not less than 50,000 spacing not more )than 100mm with suitable rated weather proof Power Converter (IP67) to achieve required illumination level, suitable for operation on airfield series circuit input source of 2.8A - 6.6A to give constant brightness for all current variation, with all other accessories such as MS base plate etc. Complete as required and confirming to ICAO/FAA requirements etc, as required , complete all as specified and as directed by Enginner-in Charge. Note: (i) All signage board shall be strictly in accoordance with ICAO/FAA Norms duely approved by users as per list enclosed as APPEX 'B' . (ii) GPS Survey shall be carried out as per requirement before installation of signage board the same shall be included in quoted rate nothing extra shall be paid to contractor on this account. (iii) Contractor shall submit the Shop drawing of all signage board within 15 days from date of commencement as per work order for approval of GE & User as per various Sizes specified in Appendix 'B' of PS and standards of ICAO/FAA requirement showing Sign type,legend,Size,location,Orientation,Illumination etc and other deatils confirming to technical specification as specified in Tender documents ,rate of the same shall be included in quoted rate nothing extra shall be paid to contractor on this account. (iv) Before completion contractor shall carried out all tests as specified in CA ,codal provision other tests as required at site as per direction of GE/Engr-in-charge and submit all satisfactory test reports to GE office,the rate of the same is deemed to be included in Quoted rate. | 25.28 | Sqm | - | - |
| 1.01 | Description of Srl Item No 1.00 Contd/- (v) Contractor shall arrange for combined Factrory inspection visit of the for approved agency from list of Specialised agencies in Tender docuemnts with User ,Accepting officer ,GE and Engr-in-charge after necessary approval of signage board shop drawings by GE and User. (vi) Any defects observed during Defect liability period for all the interlinked items pertaning to signage board including EM items shall be recified within 7 days from date of conveying the defects to the contrcator by any means (i.e Telephonically,Via Email or Via verbal orders of Engr-in-charge in person etc).Non compliance of the recification of defects within 07 Days from date of conveying shall attract the penal recovery @ double the Quoted rate of the invididual item per day of the respective signage board area beyond 07 days. | - | - | - | - |
| 2 | Supply and fixing of Double sided Internally illuminated LED based mandatory information/ Guidance Sign Boards of various sizes as cited in Appendix 'C' and depth not less than 150mm made out of 4mm thick glare free polycarbonate sheet at front facia having the required details (letters and symbols) screen printed on self adhesive film of 3M make/equivalent and pasted inside of the polycarbonate sheet and body made of 2mm thick anodised aluminium profile reinforced by 50mm X 50mm Aluminium /Aluminium alloy structure on other five sides with sufficient No. of 50mm dia aluminium legs of 5.5mm thick legs and frangible couplings, uniformly internally illuminated with adequate No of LED Modules of LED of burning hours not less than 50,000 spacing not more )than 100mm with suitable rated weather proof Power Converter (IP67) to achieve required illumination level, suitable for operation on airfield series circuit input source of 2.8A - 6.6A to give constant brightness for all current variation, with all other accessories such as MS base plate etc. Complete as required and confirming to ICAO/FAA requirements etc, as required , complete all as specified and as directed by Enginner-in Charge. Note: (i) All signage board shall be strictly in accoordance with ICAO/FAA Norms duely approved by users as per list enclosed as APPEX 'C' . (ii) GPS Survey shall be carried out as per requirement before installation of signage board the same shall be included in quoted rate nothing extra shall be paid to contractor on this account. (iii) Contractor shall submit the Shop drawing of all signage board within 15 days from date of commencement as per work order for approval of GE & User as per various Sizes specified in Appendix 'C' of PS and standards of ICAO/FAA requirement showing Sign type,legend,Size,location,Orientation,Illumination etc and other deatils confirming to technical specification as specified in Tender documents ,rate of the same shall be included in quoted rate nothing extra shall be paid to contractor on this account. (iv) Before completion contractor shall carried out all tests as specified in CA ,codal provision other tests as required at site as per direction of GE/Engr-in-charge and submit all satisfactory test reports to GE office,the rate of the same is deemed to be included in Quoted rate. | 42.35 | Sqm | - | - |
| 2.01 | Description of Srl Item No 2.00 Contd/- (v) Contractor shall arrange for combined Factrory inspection visit of the for approved agency from list of Specialised agencies in Tender docuemnts with User ,Accepting officer ,GE and Engr-in-charge after necessary approval of signage board shop drawings by GE and User. (vi) Any defects observed during Defect liability period for all the interlinked items pertaning to signage board including EM items shall be recified within 7 days from date of conveying the defects to the contrcator by any means (i.e Telephonically,Via Email or Via verbal orders of Engr-in-charge in person etc).Non compliance of the recification of defects within 07 Days from date of conveying shall attract the penal recovery @ double the Quoted rate of the invididual item per day of the respective signage board area beyond 07 days. | - | - | - | - |
| 3 | Surface excavation n exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out Hard/dense soil , complete all as specified and as directed by Enginner-in Charge. | 109.95 | Sqm | - | - |
| 4 | Earth work in excavation by mechanical means (Hydraulic excavator)/in Ordinary rock for foundation trenches or drains (not exceeding 1.5 m in width or 10 Sqm on plan),including dressing of sides and ramming of bottoms,lift upto 1.5m,including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50m ,complete all as specified and as directed by Enginner-in Charge. | 6.88 | Cum | - | - |
| 5 | Form work to sides of concrete foundations ,footings , bases of columns ,raft and raft beams , sides and soffits ( if any) of foundation and plinth beams and similar vertical or to a batter flat rough finished surface , complete all as specified and as directed by Enginner-in Charge. | 61.92 | Sqm | - | - |
| 6 | M&L TMT bars 10 mm and over cut to length, bent to shape required incl cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia quality confirming, complete all as specified and as directed by Enginner-in Charge. | 183.28 | Kg | - | - |
| 7 | Ditto as per Srl Item No 6.00 above but, 5 mm dia and over and incl 10mm dia in stirrups, spacers and binders | 195.33 | Kg | - | - |
| 8 | M&L for Reinforced cement concrete M 30 using 20mm crushed stone as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. | 4.64 | Cum | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
83030PS.pdf
Tender Documents • 0.74 MB
BOQ_889135.xls
BOQ • 1.34 MB
83030TD.pdf
Tender Documents • 0.72 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .