Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹27.1 LAccepted-Finance | L-1 | Accepted-Finance FIT | |
| 2 | L-2₹29.9 L+₹2.8 L (10.4%)Accepted-Finance | L-2 | Accepted-Finance FIT | |
| 3 | L-3₹32.8 L+₹5.7 L (21.2%)Accepted-Finance VILL POST RANI PIND DISTT HOSHIRPUR PUNJAB PIN 144202 BRANCH OFFICE MAILING ADDRESS 121 LANE 8 UPPERSIDE GREATER KAILASH JAMMU 18001 | HOSHIARPUR | PUNJAB | 144202 | L-3 | Accepted-Finance FIT | |
| 4 | L-4₹35.3 L+₹8.3 L (30.5%)Accepted-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L-4 | Accepted-Finance FIT |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
9 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Tanuj Bagla, EE
GE Kaluchak Pin-900673 C/O 56 APO
REPAIR REPLACEMENT AND MAINT OF DG SETS IN ELECTRIC/WATER SUPPLY/SECURITY LIGHT INSTALLATIONS IN RATNUCHAK MIL STN MIL STN UNDER GE KALUCHAK
2024_MES_637165_1
GE/KC/NIT-74/2023-24
Open Tender
Civil Works
Item Rate
180 days
Kaluchak
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE Kaluchak
₹76,000
Yes
27 Feb 2024
12 Jan 2024
12 Feb 2024
12 Jan 2024
9 Feb 2024
26 Jan 2024
12 Jan 2024 - 19 Jan 2024
Amount
Servicing of DG Set 250 KVA of any Make, checking entire system as per manufacturer's catalogue such as checking all parts for serviceeablility, taking down defective parts such as fuel filter assy, by pass filter assembly, lub oil filter assembly, air cleaner assy, flexible hose pipe, coolent etc and replacing the same with same size, make and capacity of parts, draining out the old used burnt engine oil from the sump cleaning all serviceable filters and oil sump with cleaning solution such as petrol/ diesel and refilling new engine oil upto required level and including testing to DG Set to entire satisfaction of Engr-in Charge. Note:- (i) Spare parts/ Engine oil/ check kit/ filter shall be measured and paid for saperately under respective items of BOQ (ii) Minimum 6 months gap/ 200 hrs of run whichever is earlier shall be considered for next service (iii) Repair Guarantee for replaced parts/servicing of DG Set shall be for six month/200 hrs from the date of service.
All as per item No 1 here-in-before but for DG set 125 KVA.
All as per item No 1 here-in-before but for DG set 100 KVA.
All as per item No 1 here-in-before but for DG set 62.5 KVA.
All as per item No 1 here-in-before but for DG set 40 KVA.
All as per item No 1 here-in-before but for DG set 30 KVA.
All as per item No 1 here-in-before but for DG set 20 KVA.
Supply only lubricant oil filter suitable for 250 KVA DG set
Supply only lubricant oil filter suitable for 125 KVA DG set
Supply only lubricant oil filter suitable for 100 KVA DG set
Supply only lubricant oil filter suitable for 62.5 KVA DG set
Supply only lubricant oil filter suitable for 40 KVA DG set
Supply only lubricant oil filter suitable for 30 KVA DG set
Supply only lubricant oil filter suitable for 20 KVA DG set
Supply only fuel filter with set of 'O' Ring for 250 KVA DG set.
Supply only fuel filter with set of 'O' Ring for 125 KVA DG set.
Supply only fuel filter with set of 'O' Ring for 100 KVA DG set.
Supply only fuel filter with set of 'O' Ring for 62.5 KVA DG set.
Supply only fuel filter with set of 'O' Ring for 40 KVA DG set.
Supply only fuel filter with set of 'O' Ring for 30 KVA DG set.
Supply only fuel filter with set of 'O' Ring for 20 KVA DG set.
Supply only air filter inner & outer suitable for 250 KVA DG set
Supply only air filter inner & outer suitable for 125 KVA DG set
Supply only air filter inner & outer suitable for 100 KVA DG set
Supply only air filter inner & outer suitable for 62.5 KVA DG set
Supply only air filter inner & outer suitable for 40 KVA DG set
Supply only air filter inner & outer suitable for 30 KVA DG set
Supply only air filter inner & outer suitable for 20 KVA DG set
Supply and changing engine oil 15W/ 40, Make: Kirloskar / Castrol/ HP
Supply and changing coolent all as specified and as directed. Make: Servo/ Shell/ Castrol/ HP
Supply and changing distilled water in for filling in batteries all as specified and as directed.
Dismantling the alternator in parts for rewinding, removing the burn out copper winding coil carefully, cleaning slots and replacing the insulation paper and re-winding 'F' class copper conductor winding wire of existing size/ shape, glass sleeves of connecting leads, binding/ tightening loose coils with binding cloths, varnishing and applying the bactol on the excitor coil/ winding with supper varnish, heating the windings at appropriate tempeature to achive required insulation resistance with out damaging the other parts, replacement of driving and non-driving end bearings, cleaning, greasing, reassembling and testing with megger for insualtion resistance etc., complete all as specified and as directed :-
Taking down existing defective injector and fuel injection pump (FIP) for the following capacity DG set installed at various installation and replacement of worn out spares like delivery valves, nozzles, bearings, fly weight, packing kit, and copper washer kit, injector element, kit injector, retainer injector cup, fixing tappit cover packing set and recalibration of FIP and refixing in same position and testing of full load checking of pressure and adjustment by dial gauge complete all as specified and as directed :-
Dismantling of unserviceable battery charging dynamo of 12 Volts from DG set of capacity 15 KVA to 100 KVA, repair and servicing of dynomo including replacement of bushes, bearings, carbon brushes, rectifires, rewinding of field magnet coil / rotor armeture coils and any other minor parts required for smooth functioning and refixing on DG set after repair/service including testing after commissioning, complete all as specified & directed.
Dismantling of old unserviceable battery charging dynomo of rating 12 volts and supply and fixing new battery charging dynomo of same specifications as per existing model suitable for fixing on DG set, 1500 rpm including testing after complete installation, complete all as specified & diirected.
Disconnecting, removing and dismantling radiator assembly from the following capacity DG sets and descaling the radiator throughly with CTC solution/ any other chemical solvent agent as approved by the Engineer-in-charge, stopping of leakage at place to copper cores and tubes by brazing scrapping the existing oil paint, dusting and painting the radiator with enamelled paint etc., re-installing and commissioning complete all as specified & directed :-
20 to 30 KVA
40 to 62.5 KVA
100 to 125 KVA
Taking down brunt unserviceable automatic voltage regulator assy from alternator of DG set by disconnecting its electrical connections, supply and fixing new AVR 12V suitable for 100 KVA DG Set including connecting all electrical connections, testing voltage after starting engine and setting properly complete all as specified & directed.
Feed pump (OEM manufactured) suitable for 15 KVA to 63 KVA DG set including taking down old unserviceable pump, complete all as specified & directed.
Feed pump (OEM manufactured) suitable for 100 KVA to 125 KVA DG set including taking down old unserviceable pump, complete all as specified & directed.
S&F in replacement maintenance free lead acid battery 12 volts 180 AH confirming to IS 7372 complete all as specified and as directed. Make : Exide / Boss / Amron/Tata green
S&F in replacement maintenance free lead acid battery 12 volts 150 AH confirming to IS 7372 complete all as specified and as directed. Make : Exide / Boss / Amron/Tata green/Luminous/Panasonic/cummins/APC/MICROTEX
S&F in replacement maintenance free lead acid battery 12 volts 90 AH confirming to IS 7372 complete all as specified and as directed. Make : Exide / Boss / Amron/Tata green/Luminous/Panasonic/cummins/APC/MICROTEX
S&F in replacement steel flexible fuel pipe, superior quality, of 10mm dia approximate length 2 RM, tightening the same with two Nos of jublee clips on both ends,complete all as specified and as directed.
Supply and fix in repair on load change over switch in sheet metal enclosure 63Amp four pole,modular type,positive isolation,door interlock and padlock facility confirming to IS/IEC 60947-3 complete all as directed.C&S cat no ECSCS63NM4CO(nm SERIES)/HPL CAT NO CDC00634PEAV
Supply and fix in repair on load change over switch in sheet metal enclosure 100Amp four pole,modular type,positive isolation,door interlock and padlock facility confirming to IS/IEC 60947-3 complete all as directed.C&S cat no ECSCS100NM4CO(nm SERIES)/HPL CAT NO CDC01004PEAV
Supply and fix in repair on load change over switch in sheet metal enclosure 160Amp four pole,modular type,positive isolation,door interlock and padlock facility confirming to IS/IEC 60947-3 complete all as directed.C&S cat no ECSCS160NM4CO(nm SERIES)/HPL CAT NO C01604PEAV
Supply and fix in repair on load change over switch in sheet metal enclosure 200Amp four pole,modular type,positive isolation,door interlock and padlock facility confirming to IS/IEC 60947-3 complete all as directed.C&S cat no ECSCS200NM4CO(nm SERIES)/HPL CAT NO C02004PEAV
Supply and fix in repair on load change over switch in sheet metal enclosure 400Amp four pole,modular type,positive isolation,door interlock and padlock facility confirming to IS/IEC 60947-3 complete all as directed.C&S cat no ECSCS400DM4CO(DM SERIES)/HPL CAT NO C04004PEAV
Dismentaling &Taking down unserviceable street light fittings LED Fittings/ CFL Fittings,post top lantern,garden light, Pin /Holder type from pole or from Bldgs for repairs including replacement of unserviceable Lamp, holder, integral wiring with appropriate gauge copper conductor and refixing the same after repairs in original position properly using PVC insulation tape or where directed complete including replacement of any spares,cable connections from OH conductors,or from junction boxes to light fitting all as specified and as directed. Note : Spares items such as LED driver and cable etc, will be measured and paid separately under respective items.
S&F LED street light fitting of capacity 60 Watt (Efficacy :120LM/W) made up of pressure die cast aluminium housing with toughened glass cover and high power LED's and secondary lenses with IP66 protection with 10 KV inbuilt surge protector including taking down existing old unserviceable light fittings from the bracket of pole or any other place not more than 8.00 metres height from ground level complete all as specified and directed.
S&F Integral LED street light fitting of capacity 90 Watt (Efficacy :120LM/W) made up of pressure die cast aluminium housing with toughened glass cover and high power LED's and secondary lenses with IP66 protection with 10 KV inbuilt surge protector including taking down existing old unserviceable light fittings from the bracket of pole or any other place not more than 8.00 metres height from ground level complete all as specified and directed.
Supply and fix Integral LED security FLOOD light luminaire 120W LED 230 volts made of pressure die cast aluminium housing with high power LED’s lens & toughned glass IP-66 including GI pipe 50mm ,medium grade ,1.7mtr long mounting bracket and providing fixing clamps ,bolts,nuts of suitable sizecomplete all as specified and as directed.
New generation, IP 65 LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. Clear Cover offers bright illumination for different applications cat part No- RUBYPT25WLED830SSYMTOPC Make Havells or eqivalent in Bajaj/Philips
Supply and fixing in replacement path light LED bollard 7W to 10W in cylindrical shape with opal acrylic diffuser and IP 65 & IK-10 protection with silent observer and giving light, diffuser at the upper portion acts a beacon of path guidance in a landscape enironment fixed on PCC block of size 450x450x600 mm with PCC 1:4:8 type D2 40mm graded all as specified and directed. Make- Philips /Wipro/Crompton/GE
S&F Thermoplastic Cable Junction Boxes IP66/67 "weather proof" , for outdoor installation with knockouts for cable entry for streetlight with terminals suitable for 10-16 sqmm cable of Size 155 X 210 X 92 mm incl aluninium busbar and MCB SP 6 amps 1 No, for street light, including necessary clamps for fixing with street light pole, and connecting all incoming and outgoing cables with AL lugs of appropiate sizes complete all as specified and directed. Make-Hensel Cat Part No-KF1616G or equivalent in sintex.
Supply and laying of LT cable in trenches or on poles / walls, XLPE Insulated screened, PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm, 2 core, ISI marked complete all as specified and directed.
Supply & Fixing in replacement of the following spare parts in street lights :-
LED Driver 60 Watt of Make Bajaj/Equivalent
LED Driver 90 Watt of Make Bajaj/Equivalent
Excavation in trenches not exceeding 1.5 metres wide and not exceeding1.5 metres in depth and getting out in any type of soil complete all as specified.
Excavation in trenches n.exc 1.5 metre wide and exc. 1.5m in depth but n.exc 3.0 metre in depths for foundations and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading , leveling , watering and well ramming in layer not exceeding 25cm each layer all as specified.
Removing excavated material not exceeding 50M and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
Sand filling in trenches for cable protection provided with layer 8cm deep before laying of cable and 15 cm after laying including spreading and leveling watering and well ramming in layer not exceeding 25mm thick complete all as specified and directed.
Supply and laying in trenches Sub class ‘B’bricks well burnt locally available for covering to cable laid dry flat ,with width of brick perpendicular to the length of cable complete all as specified and as directed.
Material and labour for PCC 1:3:6 Type C-2 (Using 40 mm grade aggregate as in foundation of pole, stay and filling and mass concrete) including providing necessary form work complete all as specified and as directed
Material and labour for PCC 1:2:4 type B1 using 20 mm grade stone aggregate as in copping of electric pole at site including providing necessary form work complete all as specified and as directed.
M&L for of PVC insulated weather prof flat twin core Aluminium cable of size 2.5 Sqmm single core including with PVC conduit of all necessary suitable iron clamp(3 nos), nut and bolts of appropriate size from junction box to street light all as specified. .
Supply and fix XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor rating 1100 volts cross sectional area 25 Sq mm 3.5 core laid in trenches or passing through pipes/ducts or fixed to walls/poles incld taking out old unserviceable under ground cable from excavated trenches /pipes (Earth work, segragating cable cover measured separately).complete all as specified.
Supply and fix Pole mounted bracket made out of GI pipe 40 mm dia medium grade of length 1.5 mtr with two clamps made out of 40x6 mm with suitable nuts, bolts and washers incld taking down old unserviceable GI bracket from pole complete all as specified and directed
M&L for GI tubing light grade with all necessary fittings laid in trenches under road crossing fixed on poles, walls under floor for cable protection complete all as specified and directed for 50 mm dia.
Supply, installation, testing and commissioning of CPRI approved, factory made, LT Feeder Pillar Box cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 450mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 400 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer (400Amps), and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable dismantled before etc., and comprising of the following:-
(a) MCCB 350 Amps, 4 pole with breaking capacity 36KA (Adjustable thermal & magnetic release) - 01 Nos(Incomer) (b) MCCB 125 Amps, 4 pole with breaking capacity 25KA (Adjustable thermal & magnetic release) - 05 Nos(Outgoing) (c) MCCB 63 Amps, 4 pole with breaking capacity 25KA (Adjustable thermal & magnetic release) - 01 Nos(Outgoing) (d) Digital Volt meter .Make Schneider Cat No DM3210 (e) Digital Ammeter meter .Make Schneider Cat No DM3110 (f) Indicator lamp RYB :01 Set (g) CT'S 400/5 01 Set (RYB) Make-L&T
Supply, installation, testing and commissioning of CPRI approved, factory made, LT Feeder Pillar Box cubical, Outdoor type, floor mounted double door, 3 phase 4 wire, 50 cycles, 415 Volts. The panel board shall be made of 3.15 thick CRCA sheet for load bearing members and 16 SWG (1.6 mm thick) for doors covers and internal partitions and shall be powder coated both side. Base frame of the panel shall be made of ICMC channel of size 50 x50 x 6mm, duly grouted on platform made of brick work in CM (1:2:4), 15mm thick plastering in CM (1:6) having minimum height of 450mm. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gears. The panel board shall be suitable for AC, 415 Volts, 50 Hz, 3 phase, 4 wire supply complete with epoxy insulated 250 Amps rated high conductivity aluminium bus bars, supported with DMC / SMC barriers and coluor coded, prewired with copper cable, the degree of protection is IP-54. the panel shall be complete with instrumentation such as LED phase indicating lamps and CT's, including extended aluminium strip of rating of Incomer and outgoing as per rating of MCCB’s, including aluminium lugs to connect the cable dismantled before etc., and comprising of the following:-
(a) MCCB 200 Amps, 4 pole with breaking capacity 25KA (Adjustable thermal & magnetic release) - 01 Nos(Incomer) (b) MCCB 100 Amps, 3 pole with breaking capacity 25KA (Adjustable thermal & magnetic release) - 05 Nos(Spare) (c) MCCB 63 Amps, 3 pole with breaking capacity 25KA (Adjustable thermal & magnetic release) - 01 Nos(Spare) (d) Digital Volt meter .Make Schneider Cat No DM3210 (e) Digital Ammeter meter .Make Schneider Cat No DM3110 (f) Indicator lamp RYB :01 Set, C&S (g) CT'S 250/5 01 Set (RYB) Make Legrand
M&L earthing complete with galvanised steel earth plate eletrode size 600 x 600 x 6.00mm thick buried directly in ground vertically in pit of depth not less than 2.25 mtr below normal ground level with top edge of the earth plate not less than 1.5 mtr below normal, ground level connceted to galvanised iron strip 32 x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI (or) steel all as shown in electrical palte No. 3 connected to earthing test point and testing on completion with and including necessary excavation and earth work including necessary excavation and earth work including lying soil, earth electrode, earthing lead earth electrode to equipment/sub station/panel etc. adequate quantity of charcoal dust and common salt. test point PCC (1:2:6) type B-1 (using 20mm graded stone aggregate/40mm thick cover reinforced with 6 mm dia TMT bars. 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20mm dia with panel, wire mess all as shown in electrical plate No 3 of SSR part 1 of 2009 and 40mm dia GI light grade pipe for earth lead and protection complete all as specified and directed all as specified directed.
Taking out old /unserviceable damaged existing steel/concrete poles of any size/length from existing position including necessary excavation and demolition of PCC foundation and removing the same from site complete all as specified and as directed.
Supply, erecting and fixing in proper position steel tubular swaged poles of type 410-SP-31 (9.0 mtr long) complete with CI base plate, finial taper plug, bolts, nuts ,screws and pole cap and inclusive of two coat of aluminium paint over a coat of red oxide primer including preparing the surface all as specified and as directed. ( Note:Excavation ,earth work and PCC shall be measured and paid separately )
Material and labour for cross arms, bracings, supports clamps and back plates fabricated from structural steel sections incl. nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide primer including preparing the surface all as specified and as directed.
Material and labour for Shackle type insulator, porcelain, vitreous white / brown including galvanized mild steel straps (of size 31 mm x 3 mm) washers, insulator bolts ( 12 mm dia) washers and nuts per size of height 75 mm and dia 90 mm for working pressure 1100 Volts all as specified and as directed.
Material and labour for Pin type insulator , porcelain, vitreous white / brown including one galvanized mild steel spindle, two galvanized iron washers and one nut (galvanized iron) , for size of 100 mm height, 65 mm dia for 1100 volts grade insulator all as specified and as directed.
VEE ESS ENGINEERS
M/s BASRA BROTHERS
MAMTA ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .