| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-Finance | ₹1.7 L | L1 | Accepted-Finance Accepted |
| 2 | L2₹1.8 LRejected-Finance | ₹1.8 L | L2 | Rejected-Finance Rejected |
| 3 | L3₹1.8 LRejected-Finance VILLAGE SANDHASU P O KHASHDHAR TEHSIL CHIRGAON DISTT SHIMLA H P | ₹1.8 L | L3 | Rejected-Finance Rejected |
| Sl No | Description | Qty | Unit | ANSHU SHARMA L1 | NIPINDER SINGH L2 | VIJAY CHAUHAN L3 |
|---|---|---|---|---|---|---|
| 1.00 | Wiring for light point/fan point/exhaust fan/call bell point with 1.5 Sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC Conduit conductor and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. with in all leads and lifts as per direction of the Engineer-in-Charge. Group ( A.) | 58 | P/ Point | 980 ₹56,840 | 1,000 ₹58,000 | 1,000 ₹58,000 |
| 2.00 | Wiring for power plug with 2.5 Sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke sinlge core (flexible) copper conductor cable in PVC Conduit along with 1 No. 4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.with in all leads and lifts as per direction of the Engineer-in-Charge. Group (A.) | 180 | P/Rmt | 50 ₹9,000 | 60 ₹10,800 | 70 ₹12,600 |
| 3.00 | Wiring for power plug with 4Sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke sinlge core (flexible) copper conductor cable in PVC Conduit along with 2 No. 4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.with in all leads and lifts as per direction of the Engineer-in-Charge. Group (A.) | 40 | P/Rmt | 60 ₹2,400 | 70 ₹2,800 | 80 ₹3,200 |
| 4.00Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke sinlge core (flexible) copper conductor cable in PVC Conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. with in all leads and lifts as per direction of the Engineer-in-Charge. | ||||||
| 4.01 | 2x1.5 Sq.mm. | 270 | P/Rmt | 90 ₹24,300 | 100 ₹27,000 | 110 ₹29,700 |
| 5.00Supplying and fixing following size modular base and cover plate on the existing modular metal boxes as required:- | ||||||
| 5.01 | Modular base and cover plate, 3 module. | 8 | Each | 80 ₹640 | 80 ₹640 | 90 ₹720 |
| 5.02 | modular base and cover plate, 8 module. | 6 | Each | 200 ₹1,200 | 200 ₹1,200 | 210 ₹1,260 |
| 5.03 | modular base and cover plate, 6 module. | 4 | Each | 150 ₹600 | 150 ₹600 | 160 ₹640 |
| 6.00Supplying and fixing following rating Piano-type switch/socket on the existing switch box/cover including connections etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge. | ||||||
Tender Value
₹1.2 L
EMD Value
₹2,483
Closing Date
27 Jan 2026, 11:00 amClosed
Executive Engineer
JSV Division Rohru
SH R M of Electric Wiring in Pump house cum attendant quarter LWSS Jhalwari stage 1st and 2nd
2026_HPIPH_126333_1
No.JSV-RD-AB-Tnd/2025- 6679-6740 dt 20.01.2026
Open Tender
Civil Works
30 days
Rohru
Tender Document
8 documents required · 8 mandatory
₹500
EE Rohru
₹2,483
9 Mar 2026
20 Jan 2026
27 Jan 2026
20 Jan 2026
27 Jan 2026
20 Jan 2026
Wiring for light point/fan point/exhaust fan/call bell point with 1.5 Sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in PVC Conduit conductor and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. with in all leads and lifts as per direction of the Engineer-in-Charge. Group ( A.)
Wiring for power plug with 2.5 Sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke sinlge core (flexible) copper conductor cable in PVC Conduit along with 1 No. 4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.with in all leads and lifts as per direction of the Engineer-in-Charge. Group (A.)
Wiring for power plug with 4Sq.mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke sinlge core (flexible) copper conductor cable in PVC Conduit along with 2 No. 4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.with in all leads and lifts as per direction of the Engineer-in-Charge. Group (A.)
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke sinlge core (flexible) copper conductor cable in PVC Conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
2x1.5 Sq.mm.
Supplying and fixing following size modular base and cover plate on the existing modular metal boxes as required:-
Modular base and cover plate, 3 module.
modular base and cover plate, 8 module.
modular base and cover plate, 6 module.
Supplying and fixing following rating Piano-type switch/socket on the existing switch box/cover including connections etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
S.P. 5/6 Amps one way switch, piano type.
S.P. 15/16 Amps one way switch, porcelain base/paino type.
5 pn 5/6 Amps socket outlet, poreclain base/piano type.
6 pin 15/16 Amps socket outlet, porcelain base/piano type.
Supplying and fixing bakelite batten/angle holder including connections etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge.
Supplying and erection of 6 amps, to 32 amps, rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge. Single pole . Cat-A
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge. 40 Amps. Cat- A
Supplying and fixing of following way, single pole and netural sheet steel MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus-bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels inter-connections phosphatized and powder painted, including earthing etc. as required. with in all leads and lifts as per direction of the Engineer-in-Charge. Double door-8 way
Wiring for batten holder etc. required bottam floor with in all leads and lifts and as directed by the Engineer-in-charge.
Wiring for angle holder etc. required bottam floor with in all leads and lifts and as directed by the Engineer-in-charge.
Providing and fixing casing, capping 3/4" complete in all respect.
Providing and installation of following type of surface mounting square/round type LED panel Light with aluminium die cast housing in white finish with anti glare polycarbonate diffuser and seprated energy efficient constant current, non-integral, electronic driver; suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, connections, testing etc. as required: of Approved Make
Square/round LED Panel Light 10/12W Surface
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.02 MB
F6.pdf
Tender Documents • 0.06 MB
F7and8.pdf
Tender Documents • 2.82 MB
termandcondition.pdf
Tender Documents • 0.19 MB
BOQ_186214.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid