| 1 | 1₹10.0 LAccepted-AOC 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 UDYAM PB 19 0009496 | SANGRUR | PUNJAB | 148001 | ₹10.0 L | 1 | Accepted-AOC LOWEST AND REASONABLE |
| 2 | 2₹12.0 L+₹2.0 L (20.2%)Rejected-Finance 255 VILLAGE UGRA POST OFFICE BARA AMBALA HARAYANA PIN 134003 | AMBALA | AMBALA | HARYANA | 134003 | ₹12.0 L+₹2.0 L (20.2%) | 2 | Rejected-Finance NOT LOWEST |
| 3 | 3₹12.5 L+₹2.5 L (25.4%)Rejected-Finance | ₹12.5 L+₹2.5 L (25.4%) | 3 | Rejected-Finance NOT LOWEST |
| 4 | Rejected-Technical | - | - | Rejected-Technical NO REMARKS IN WLR QE END JUN 2022 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
13 Apr 2023, 6:00 pmClosed
LT COL ANIMESH TRIPATHI
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
REPAIR MAINT TO CEILING FANS EXHAUST FANS AND DESERT COOLERS UNDER GE N PATIALA
2023_MES_586222_1
GE(N)/TOKEN-5/2023-24
Open Tender
Electrical and Maintenance Works
Item Wise
180 days
PATIALA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE NORTH PATIALA
₹30,000
Yes
16 May 2023
17 Mar 2023
15 Apr 2023
17 Mar 2023
13 Apr 2023
31 Mar 2023
Amount
Dismantling of ceiling fan 1200 mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins, body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
Dismantling of ceiling fan 1400 mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins, body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
Dismantling of wall mounting/Cabin fan 380/400mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins, body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
Dismantling of industrial wall mounting air circulator fan 450/600mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins, body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
Dismantling of exhaust fan 380/450mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins, body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed.
Dismantling of exhaust fan 225/300 mm sweep, (any make and type , taking out rotor, removing all coils (burnt and alive), rewinding all the coils with suitable size super enamelled copper wire (ISI Marked) including all packing materials, insulating materials, varnishing, greasing, oil, re-assembling, split pins, body/blade screws and testing on full speed,. as per the direction of Engineer-in-Charge complete all as specified and directed. Note for item No. 1.00 to 6.00 : It is the prime responsibility of EIC to ascertain the necessity of rewinding to a particular fan. Before handing over fan to the contractor, testing for winding shall be done in presence of EIC and all such fans shall be stored separately for subsequent repair from the contractor.
Supply and replacement of exhaust fan motor suitable for 225/230mm sweep complete including necessary fitting & connection complete all as specified and directed.
Supply and replacement of exhaust fan motor suitable for 300mm sweep complete including necessary fitting & connection complete all as specified and directed.
Supply and replacement of exhaust fan motor suitable for 380/450mm sweep complete including necessary fitting & connection complete all as specified and directed.
Supply and replacement of industrial wall mounted fan motor suitable for 450/600mm sweep complete including necessary fitting & connection complete all as specified and directed.
Opening up ceiling fan, exhaust fans, wall mounting/table fans, air circulator fans (any sweep, size or make) as kept unserviceable in E/M store yard for detection of defect and reassembling after cleaning, greasing and overhauling including replacement of split pins, body/blade screws and testing before depositing in store yard complete all as specified and directed. Note: Other spares necessary to be replaced shall be measured and paid for separately under following items of this schedule.
Replacement of Capacitor 2.5/3.15 mfd 230 Volts (+) 5 % dry type complete all as specified and directed. Make- TIBCON/ELCAP/'AD/TORCON)
Supply and fixing PVC capacitor assy two ways with fixing screws any type complete all as specified and directed
Supply and replacement of ball bearing for ceiling fans of any sweep/size/ any make complete all as specified and directed. Size of 6200,6201,6202,6203,6204 & size S-7/S-8 (Make of bearing : Make ABC/SKF/NBC. Note : Ball bearing shall be replaced in the store yard of E/M or in the civil workshop on lathe machine if required and cost thereof shall be included under this item.
Replacement of gun metal bush for ceiling fans, exhaust fans and cabins fans of any makes/size complete all as of specified and directed. Note : Bush shall be replaced in the store yard of E/M or in the civil workshop on lathe machine if required and cost thereof shall be included under this item. Note:- Cost of replacement of UNSV Shaft for exhaust fan of capacity 200/300mm sweep shall be included under this item.
Supply and replace rubber reel of fan complete with ms split clamp two Nos nuts and bolts complete all as specified and directed .
Supply and replace fan regulator electronic, Piano type, stepped, AC 230 volts suitable for 1200mm/1400mm ceiling fan complete all as specified and directed .
Supply and replace fan regulator electronic, modular type as per sample, stepped, AC 230 volts suitable for 1200mm/1400mm ceiling fan complete all as specified and directed .
Replacement of Capacitor 4 mfd 230 Volts (+) 5 % dry type complete suitable for desert cooler all as specified and directed. Make- TIBCON/ELCAP/'AD/TORCON)
Replacement of ceiling fan blade suitable for 1200 mm sweep ceiling fan including nuts, washers etc complete all as specified and directed suitable for any make of fan approved by engineer-in-charge. (white/Browm colour/as per site requirement).
Supply and connecting flexible Cable of copper wire 2 core of size 23/0.0076, 0.5 sq mm (white colour) complete all as specified and directed.
Supply & fixing as in repair louvers made out of 0.63 mm galvanised iron sheet for Exhaust Fan of any make and size upto 300 mm complete all as speicfied and directed.
Supply & fixing as in repair louvers made out of 0.63mm galvanised iron sheet for exhaust fan of any make and size 380mm/450mm complete all as speicfied and directed.
Replacement of PVC canopy (upper/bottom) for ceiling fan of any make and size complete all as speicfied and directed.
Supply & fixing down rod for ceiling fans made out of MS pipe 15mm bore medium grade 60 cm long duly threaded, holes drilled and spray painted with synthetic enamel paint complete all as speicfied and directed.
Spray painting on outside body of the ceiling fan incl blades any size with synthetic enamel paint (white colour) including scrapping existing paint and incl writing MES Number with black paint complete all as speicfied and directed.
Spray painting on outside body of the exhaust fan incl blades any size with synthetic enamel paint (smoke gray colour) including scrapping existing paint and incl writing MES Number with black paint complete all as speicfied and directed.
Painting of one coat of primer red oxide and two coat of super enamelled paint for Desert cooler and matching the same on the exterior colour by metal paste/puty and of any size/ make complete all as specified and directed.
Dismantling of desert cooler motor,(any make and type,taking out rotor removing all coils(burnt and alive)rewinding all the coils with suitable size super enamled copper wire(ISI marked) including all packing materials,insulating materials,varnishing greesing oils,reassembling,split pins, body blade screw and testing on full speed as per the direction of EIC complete all as specified and directed . Note: Cost of Replacement of UNSV gun metal bush and shaft for desert cooler shall be included under this item
Supply and fixing in replacement submersible PVC body Tulu pump suitable for desert cooler of any size complete all as specified and directed. Make- KHAITAN/COOL HOME/CG
Supply and fixing in replacement wood wool padding for desert coolers on all three sides ( for any size and type of cooler) complete all as specified and directed.
Supply and fixing flexible PVC transparent 15mm bore pipe set comprising one pipe from pump to PVC junction and 3 Nos short pieces of pipe from junction to shutter.
Supply and replacement of fan motor 1/10HP capacity suitable for desert cooler complete including necessary fitting & connection. Make:Khaitan/Cool home/Crompton Greaves
Supply and replacement of Desert Cooler body duly spray painted made out of 22 gauge MS sheet complete with front grill side shutters, control switch piano type 5 Amp speed regulator including lamp, wiring with suitable copper cable complete all connection
Supply and fixing in replacement of PVC front grill (Jali) suitable to existing size.
Supply and fix as in replacement flexible copper conductor cable 3 core, PVC insulated of size 70/.0076 and connected electrically to any electric devices/of any capacity size type & make etc complete all as specified and directed.
Supply & replacement of regulator knob type switch, 3 step control of speed of Desert cooler motor 230 volts, 50 Hz all as specified and directed.
S & F fan blade of suitable size for desert cooler complete all as specified and directed.
S & F Top Plug 3 Pin 5 Amps 230 Volts complete all as specified and directed.
S & F metallic frame with set of 4 legs as per model suitable for fixing/mounting fan motor of desert cooler with nuts, bolts, rubber etc., complete all as specified and directed.
S&F in replacement of PVC water distributer and elbow for desert cooler ( for any type and size of desert cooler) complete all as specified and directed.
Supply and replacement of PTMT Ball Valve suitable for 15 mm bore pipe complete suitable for desert cooler complete all as specified and directed.
u and v engineers and consultants
m/s s.n. builders
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .