GE (WEST) PATHANKOT
LOWERING AND LIFTING OF VARIOUS TYPES OF MOTOR PUMP SETS FOR REPAIR REPLACEMENT INCLUDING REPAIRS TO CHLORINATION PLANTS, CLEANING OF OVERHEAD TANKS AND ALLIED WORKS OF WATER SUPPLY SYSTEM UNDER GE (WEST) PATHANKOT
2022_MES_567318_1
GE/PKT-54/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (WEST) PATHANKOT
Please refer tender documents
9 documents required · 9 mandatory
₹500
GE (WEST) PATHANKOT
₹40,000
Yes
7 Feb 2023
5 Dec 2022
4 Jan 2023
5 Dec 2022
2 Jan 2023
20 Dec 2022
6 Dec 2022 - 15 Dec 2022
Amount
Taking out carefully submersible pumpset of (any capacity and make) from the borewell (80 ft-100 ft depth) after disconnection all electrical connection complete with column pipes,submersible cable, bends etc and taken to workshop for repairing complete all as directed by Engr-in-Charge. Note- All the arrangements, Special type of T&P, transpotaion is deemed to be included in the quoted rate.)
Strip opening of 3 phase AC submersible motor taking out burnt winding complete and re-winding with PVC insulated super quality copper winding wire, water proof complete with all materials i.e laminated paper, strips, PVC tape and sealing material etc of cap 4- 10 HP complete all as specified and directed by Engr-in-Charge.
All as per srl item no. 2.00 above but of cap 20/25 HP
All as per srl item no. 2.00 above but of cap 30 HP
All as per srl item no. 2.00 above but of cap 40 HP. Note :- For item Nos 2 to 5, If winding of motor burnts within 1 Yr of rewinding date .The Dept shall not pay to contractor for respective motor rewinding, lowering & lifting work.
Taking out old worn out bearing bush sleeves from the submersible motor of capacity 4 to 40 HP and S&F new stainless steel sleeve complete all as specified and directed.
Dismantling rotar shaft of motor of capacity 20 to 40HP,welding,brazing with suitable metal to bearing size of rotor/checknut of rotor & turning,facing,grinding, polishing etc up to required size of bearing for smooth functioning complete all as specified & directed. Note:- Rotor shaft shall be measured as supply only under relevent item.
S & F in replacement of thrust plate alongwith revolving disc complete of capacity 4 HP to 10 HP complete all as specified & directed .
S & F in replacement of thrust plate alongwith revolving disc complete of capacity20/ 25 HP to 40 HP complete all as specified & directed .
S & F in replacement of Rotor shaft with gun metal bush as per sample (set of bushes) of capacity 4 HP to 20 HP complete all as specified & directed .
S & F in replacement of Rotor shaft with gun metal bush as per sample (set of bushes) of capacity 25 HP to 40 HP complete all as specified & directed .
S & F in replacement of mechanical seal as per sample and size of capacity 4 to 20 HP complete all as specified & directed .
S & F in replacement of mechanical seal as per sample and size of capacity 25 to 40 HP. complete all as specified & directed .
S & F in replacement of Motor pump coupling assembly with key from 20 to 40 HP complete all as specified & directed .
S & F in replacement of T-bolts as per sample complete all as specified & directed .
S & F in replacement of cable joints of submersible cables as per sample upto 16 sqmm of cable with PVC compound, tape and other sealing materials complete all as specified & directed .
Dismantling of motor submersible and taking out old small pieces of 6 to 16 sqmm cable, star-delta connections and S&F both new cable joint inside the motor 2X 6-16 sqmm cable X 3 mtr long each complete all as specified & directed .
Dismantling the submersible pump bowls assembly of any make for carrying out repair and replacement of worn out parts by welding,cutting,turning,and brazing etc, Strip opening of all parts such as bowl casing, impellers, pump shafts, lock collects, bushes, neck rings etc and assembling the pump after complete repair all as directed by Engr-in-charge and replacing of parts of pump of 5 to 9 stages, having 4 HP to 20 HP capacity Note:- Spares parts shall be paid separately under relavent items of schedule as supply only.
All as per srl item No 18.00 above but of cap above 20 to 40 HP complete all as specified & directed .
S & F in replacement of SS pump shaft suitable for submersible pump set of capacity 4HP to 20 HP including threading cutting to size complete all as specified & directed .
All as per srl item No 20.00 above but of capacity 25 to 40 HP.
S & F in replacement SS distance bushes of capacity 4 to 20 HP all as specified and directed by Engr-in-charge.
All as per srl item No 22.00 above but of capacity 25 to 40 HP.
S & F in replacement neck ring of bowls complete of cap 4HP to 20 HP complete all as specified and directed by Engr-in-charge.
All as per srl item No 24.00 above but of capacity 25 to 40 HP.
S & F in replacement of GM/SS impellers suitable size and as per sample for bowl assembly of submersible pumping set of capacity 4HP to 20 HP as per site requirement for bowls complete all as specified and directed by Engr-in-charge.
All as per srl item No 26.00 above but of capacity 25 to 40 HP.
S & F in replacement of steel caged rubber bushes of bowl for pump capacity 4HP to 20 HP complete all as specified and directed by Engr-in-charge.
All as per srl item No 28.00 above but of capacity 25 to 40 HP.
S & F in replacement of CI casing of bowls assy of cap 4HP to 20 HP complete all as specified and directed by Engr-in-charge.
All as per srl item No 8.00 above but of capacity 25 to 40 HP.
S & F in replacement of Gun metal bush of bowls of capacity 4HP to 20 HP complete all as specified and directed by Engr-in-charge.
All as per srl item No 32.00 above but of capacity 25 to 40 HP.
S & F in replacement of SS impeller key as per sample of cap 4-40 HP all as specified and directed by Engr-in-charge.
S & F in replacement of studs with nuts & bolts complete all as specified and directed by Engr-in-charge.
S & F in replacement pump shaft coupling with key complete all as specified and directed by Engr-in-charge.
S & F in replacement Steel cage made of MS strip 25mmX5 mm to avoid the breakage of pump as a safty guard and welding with MS column pipe complete all as specified and directed by Engr-in-charge.
S & F in replacement rubber gaskets and nuts bolts with MS column pipe for fixing of pump set complete all as specified and directed by Engr-in-charge.
Lowering of submersible pump-set after complete repair and maint works, taking back from workshop to site, including electrical connections, testing and commissioning as per directions of Engr-in-charge. Note- All the arrangements, Special type of T&P, transpotaion is deemed to be included in the quoted rate)
S & F Mild steel column pipe for submersible pump 125 mm dia, heavy duty C class 5.4 mm thick and 3 meter long duly welded MS flange 10 mm thick duly drilled holes 06 Nos on both sides of coloum pipe incl making suitable joints using suitable rubber gasket 3 mm thick complete all as directed by Engr-in-carge.
Supply and laying PVC insulated submersible copper cable flat type in repairs for volatge 1100V confirming to IS 694:1990 of size 10 sqmm 3 core complete all as directed by Engr-in-carge.
All as per srl item No 41.00 here-in-before but of size 16 sqmm 3 core complete.
All as per srl item No 41.00 here-in-before but of size 6 sqmm 3 core complete.
S & F in replacement water pressure guage liquid filled with guage cock & fixing after making hole in the CI/GI pipelines, size of sample 4 inc dial X 0-200 psi complete all as directed by Engr-in-carge.
Checking of chemical dosing plant at site and repair / replacement to agitator, pump, piping, valves and other connected spare parts mentioned below for smooth fucntioning the plants complete all specified as directed by Engr-in-charge. (Note:- Spare parts shall be measured and paid seperately under relevent item of BOQ)
S&F in replacement PE tubing D-5/8 mm complete all as specified and directed.
S&F in replacement suction valve (foot valve) complete all as specified and directed.
S&F in replacement suction head valve complete all as specified and directed.
S&F in replacement Discharge valve complete all as specified and directed.
S&F in replacement line injector delivery valve complete all as specified and directed.
S&F in replacement Spring for discharge valve complete all as specified and directed.
S&F in replacement main diapharm as per sample complete all as specified and directed.
S&F in replacement pulsar Assy for dosing pump complete all as specified and directed.
Rewinding of agitator motor with super enamelled copper winding wire complete of capacity upto 1.0 HP complete all as specified and directed.
Replacement of agitator shaft with impeller complete all as specified and directed.
Cleaning of Over head tanks upto 20 metre staging height by under taking the cleaning in two stage process are as under :- (a) Descalling the inner surface by using high pressure rotary jets, pumping out the mud, algae and other dust particles by suction pump and industrial vaccum cleaner. (b) Treatment walls, roof and floor by specially developed biodegradable and eco friendly antibacterial agent. Note : (1) Tank to be cleaned in 6 montly basis. (2) writing tank capacity, date of cleaning, date of next cleaning on tank wall/pillar with black paint background and letters in white paint having size not less than 25 mm height.
Tank capacity of 25000 to 30000 Glns
Tank capacity of 50000 Glns
Tank capacity of 100000 Glns
S & F in replacement automatic DOL Starter suitable for upto 7.5 HP 440 Volt complete all as specified and directed.
S & F in replacement automatic star delta Starter suitable for upto 20-40 HP 440 Volt complete all as specified and directed.
Repairing of Star Delta Starter of 20 to 40 HP of any make by replacing contactor, relays, wiring etc include testing and commissioninng complete all as specified and directed. Note : Contactor & relays should be measured and paid under relevant items as supply only.
Supply only Power Contactor LC1E95 Easy pact TVS with 1 NO& 1 NC auxilary contacts, 415 volts complete all as specified and directed.
Supply only Power Contactor MNX 70 with relays and coil complete S 415 volts complete all as specified and directed.
Supply only Contactor ML-3 complete with auxilary contacts 2 NO & 2 NC, 415 volts complete all as specified and directed.
Supply only Contactor ML-4 complete with auxilary contacts 2 NO & 2 NC, 415 volts complete all as specified and directed.
Supply only delay timer relay ST-100 of complete all as specified and directed.
Supply only Bimetal Over load relay of rating 9- 22 Amps, 415 Volts, complete all as specified and directed
Supply only Bimetal Over load relay of rating 24- 40 Amps, 415 Volts, complete all as specified and directed
S&F in replacement repair MCCB 3 Pole LT 415 volt, 50 Hz, AC, 63-100 Amps 16 kA with 80% to 100% adjustable thermal and 5 to 10 In adjustable magnetic release, having ICS=ICU=100%, conforming to IEC 60947-2 including spreader lings complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 3 Pole LT 415 volt, 50 Hz, AC, 125 Amps 16 kA with 80% to 100% adjustable thermal and 5 to 10 In adjustable magnetic release, having ICS=ICU=100%, conforming to IEC 60947-2 including spreader lings complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 3 Pole LT 415 volt, 50 Hz, AC, 160 Amps 36 kA, with 80% to 100% adjustable thermal and 5 to 10 In adjustable magnetic release, having ICS=ICU=100%, conforming to IEC 60947-2 including spreader lings complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCCB 3 Pole LT 415 volt, 50 Hz, AC, 200 Amps 36 kA, with 80% to 100% adjustable thermal and 5 to 10 In adjustable magnetic release, having ICS=ICU=100%, conforming to IEC 60947-2 including spreader lings complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of display notice board made of fibre, decorative type and having the aluminum borders and inside 3 mm fibre sheet board will have arrengmetnt of clips to hold the standing orders of any type (04 Nos) of size 120cm x80cm with hanging arrangement on wall incl plastic transperant sheet (talk sheet) of board size which completely covers the front side of board complete all as specified and directed by Engr in charge
M & L in replacement of Flex sign board of size 5'x3' showing schematic distribution diagram and details of pump house machinery and duly fixed on suitable MS square frame complete all as specified and directed by Engr-in-charge.
Supply, Installation, testing & commisioning in replacement, totally enclosed feeder piller outdoor type (IP-65) fabricated out of 3.15 mm thick CRCA sheet dust and vermin proof powder coated double door type(independent cabin including locking arrangement for each MCCBs , bus bar chamber (enclosed) including locking arrangement complete suitable for operating on 415 Volt 50 Hz AC, supply internally wired with copper conductor , TPN bus bar of copper strip (4 Nos) of 250 Amps insulated by heat shrinkable sleaves & clips on shrouds for joints busbar shall be designed to withstand a fault level at 415 Volts having legs 105cms made out of 65x65x6 mm angle iron grouted on PCC 1:3:6 upto 45 cms pannel should be 60 cms above the Ground Level including diamantling the old panel comprising the following :-
Supply and fixing MS Clamps on 6" dia water mains (made out of 10 mm x 75 mm MS flat with four nuts & bolts and fixing one no SS nipple 6" long of 25 mm on the clamp with one socket and fixing tappered SS funnel 1"x6" (SS) on top and fixing 25 mm dia ball valve of stainless steel tested upto 600psi all as specified and directed.
M&L for 15mm bore GI pipe, medium grade with all fitttings, laid in trenches, on walls, complete all as specified and directed by Engineer-in-Charge. (Note :- Excavation and earth work shall be measured and paid saperately under relevant items of BOQ.)
All as per Srl item No. 75.00 above but 20mm bore.
All as per Srl item No. 75.00 above but 25mm bore.
All as per Srl item No. 75.00 above but 40mm bore.
All as per Srl item No. 75.00 above but 50mm bore.
All as per Srl item No. 75.00 above but 80mm bore.
All as per Srl item No. 75.00 above but 100mm bore.
Taking up or down GI tubing including connections carefully, for relaying or removal from site all as directed and specified by Engr - in - Charge, of 15 mm dia size :- (Note- Excavation and earth work shall measured and paid saperately under relative item).
All as per Srl item No. 82.00 above but 20mm bore.
All as per Srl item No. 82.00 above but 25mm bore.
All as per Srl item No. 82.00 above but 40mm bore.
All as per Srl item No. 82.00 above but 50mm bore.
All as per Srl item No. 82.00 above but 80mm bore.
All as per Srl item No. 82.00 above but 100mm bore.
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth in any type of soil for repairing/ replacement of CI/GI pipes including getting out excavated earth complete all as specified and directed.
Returning, filling in trenches incl spreading and leveling, watering and well ramming in layers n.exc. 25 cm thick all as specified and directed.
Removal of excavated soil to a distance n.exc. 50 mtr and depositing the same where directed at a level n.exc. 1.5 mtr above starting point complete all as specified and directed.
M & L for replacement of electronic motor protection relay with thermal overload range 8-22 Amps, with in-built earth fault protection having in-built CTs, trip indication, with protection of overload, earth fault, locked rotor, single phasing, current unbalance, phase sequence reversal, under current as per IEC-60947-4-1 complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of electronic motor protection relay with thermal overload range 16 -44 Amps, with in-built earth fault protection having in-built CTs, trip indication, with protection of overload, earth fault, locked rotor, single phasing, current unbalance, phase sequence reversal, under current as per IEC-60947-4-1 complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of changeover switch without enclosure, having rotary handle for panel mounting, three phase, 415 volt, 125 Amps, 4 pole complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of changeover switch without enclosure, having rotary handle for panel mounting, three phase, 415 volt, 200 Amps, 4 pole complete all as specified and directed by Engineer-in-Charge.
M & L for replacement of Ammeter 0-100 Amps of size 96 x 96mm suitable for panel mounting complete all as specified and directed
M & L for replacement of Voltmenter 0-500 Amps of size 96 x 96mm suitable for panel mounting complete all as specified and directed
M & L for replacement of RYB indicators in LT panels complete all as specified and directed
M & L for replacement of sign board of size 10' x 2' x 1 1/2' made on Acp sheet fixed in rectangular MS pipe of size 1" heavy grade for frame & legs having name of installation as required by Engineer-in-Charge printed on it with 4 x 4' long LED tube lights with suitable size of PVC insulated copper wiring fixed with suitable MCB for switching ON/OFF on wall and making connection with existing point complete all as specified and directed by Engineer-in-Charge. Note:- (1) Cost of earthwork, PCC filling in PCC 1:2:4 for foundation of legs included in the item and nothing extra shall be admissible on this account. (2) Minimum height of the frame shall be not less than 1.5 mtr as directed by Engr-in-charge.
Notes :- (a) The contract sum shall be arrived at after deduction of amount of Schedule of Credit. (Rs. 1,18,332.00). (b) PERFORMANCE SECURITY :- (Refer condition 19 of IAFW-2249) The performance security for an amount equivalent to 3% (Three percent) of the accepted contract sum shall be delivered by the successful bidder immediately after the date of intimation letter of acceptance and all provisions shall be applicable as per condition 19 of IAFW 2249
M/S GULATI ENGINEERING WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .