Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC GE W COLABA MUMBAI | CHANDRAPUR | MAHARASHTRA | 441205 | ₹21.8 L Quoted ₹22.5 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹26.3 LRejected-Finance | ₹26.3 L | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹26.9 LRejected-Finance 3 M S SATGURU ENTERPRISES VISHWAKARMA DHARAMSHALA HISAR HARYANA 125001 UDYAM HR 06 0006866 06AEAPM7495R1ZN B R | HISAR | HARYANA | 125001 | ₹26.9 L | L3 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | SN CONSTRUCTION L1 | I.J Enterprises L2 | SATGURU ENTERPRISE L3 |
|---|---|---|---|---|---|---|
| 1.00Note : The tenderer shall note that before quoting his unit rate, all items of works shall be executed in high rise building ( upto 15th floor building) & provision of necessary scaffolding & safety measures should be included. | ||||||
| 2.00 | Demolition of cement concrete filling of any description in sunken portion and removing debris out side MD land complete all as specified and directed. | 95 | Cum | 150 ₹14,250 | 270 ₹25,650 | 140 ₹13,300 |
| 3.00 | M&L for cleaning of sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely and 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for spout (Cost of cutting holes and pipes shall be measured and paid separately) | 195 | Sqm | 90 ₹17,550 | 145 ₹28,275 | 290 ₹56,550 |
| 4.00 | M&L for Rendering of uneven surfaces with 10mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting carried out.(WPC shall be measured & paid separately)
Note- 1. All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty.2. After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean. | 195 | Sqm | 90 ₹17,550 | 75 ₹14,625 | 290 ₹56,550 |
| 5.00 | M&L for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level+300mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed. | 530 | Sqm | 40 ₹21,200 | 60 ₹31,800 | 240 ₹1.3 L |
| 6.00 | M&L for Plastering the bottom and sides up to 300mm height from bottom of the floor level with 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout.(WPC shall be measured & paid separately) | 530 | Sqm | 45 ₹23,850 | 90 ₹47,700 | 190 ₹1.0 L |
| 7.00 | M&L for covering All pipes laid in sunken portion with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint.
Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Cost of testing is included in the rates quoted above. | 75 | RM | 60 ₹4,500 | 60 ₹4,500 | 200 ₹15,000 |
| 8.00 | M&L for Cutting holes n exc 150 Sqcm into or through brick walls built in cement mortar or cement lime mortar and stone walls and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required after inserting and setting spouts all as specified. | 1,150 | Per CM Depth of Cutting | 5 ₹5,750 | 55 ₹63,250 | 20 ₹23,000 |
| 9.00 | S&F GI pipe 50mm dia medium grade laid on sunken floor complete all as specified and direced by EIC. | 15 | RM | 250 ₹3,750 | 250 ₹3,750 | 350 ₹5,250 |
| 10.00 | M&L for Injection grouting in RCC slab shall be cast/laid to the slope as directed/as per site conditions. After RCC slab is laid, cured and fully set, water shall be ponded in the sunken slab portion as per specified ponding test. The location of seepage/leakage, if any, shall be identified and marked. The portion of the slab where leakage/seepage is observed shall be repaired with grouting at contractor's expences. The area of dripping/leakage shall be cleaned to expose the surface. Mark the spots for injection grouting. If leakage is through a crack, mark grouting points along the crack in a staggered manner. If the leakage is across the area mark grouting spots in a grid pattern. Drill grouting holes so as to neatly fit the injection packers. Drilling to be done at an angle of 45 to the plane of grouting surface. Fix PVC/MS nozzles in the low viscosity, injecting polyurethane resin/epoxy grout using a grouting pump. Repeat the process after 1 or 2 days if the leakage continues at some point. allow to cure for 24 hours and seal the grouting holes appropriately using epoxy putty etc complete all as specified and as directed. | 200 | Each | 160 ₹32,000 | 75 ₹15,000 | 320 ₹64,000 |
Updated dates
Tender Value
₹49.8 L
EMD Value
₹99,560
Closing Date
22 Nov 2025, 6:00 pmClosed
GE (NW) NOFRA
Dr Homi Bhabha Road Navy Nagar Colaba Mumbai
REPAIR MAINT OF SUNKEN PORTION AT MD OTM ACCN OF AGE BR II UNDER GE (NW) NOFRA
2025_MES_737242_1
8457/E8
Open Tender
Civil Works
330 days
Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE (NW) NOFRA
₹99,560
Yes
31 Mar 2026
28 Oct 2025
24 Nov 2025
28 Oct 2025
22 Nov 2025
10 Nov 2025
28 Oct 2025 - 3 Nov 2025
Amount
Note : The tenderer shall note that before quoting his unit rate, all items of works shall be executed in high rise building ( upto 15th floor building) & provision of necessary scaffolding & safety measures should be included.
Demolition of cement concrete filling of any description in sunken portion and removing debris out side MD land complete all as specified and directed.
M&L for cleaning of sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely and 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for spout (Cost of cutting holes and pipes shall be measured and paid separately)
M&L for Rendering of uneven surfaces with 10mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting carried out.(WPC shall be measured & paid separately) Note- 1. All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty.2. After drying putty, wash the slab and sides of sunken portion with water and make it clear and clean.
M&L for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level+300mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed.
M&L for Plastering the bottom and sides up to 300mm height from bottom of the floor level with 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout.(WPC shall be measured & paid separately)
M&L for covering All pipes laid in sunken portion with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint. Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Cost of testing is included in the rates quoted above.
M&L for Cutting holes n exc 150 Sqcm into or through brick walls built in cement mortar or cement lime mortar and stone walls and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required after inserting and setting spouts all as specified.
S&F GI pipe 50mm dia medium grade laid on sunken floor complete all as specified and direced by EIC.
M&L for Injection grouting in RCC slab shall be cast/laid to the slope as directed/as per site conditions. After RCC slab is laid, cured and fully set, water shall be ponded in the sunken slab portion as per specified ponding test. The location of seepage/leakage, if any, shall be identified and marked. The portion of the slab where leakage/seepage is observed shall be repaired with grouting at contractor's expences. The area of dripping/leakage shall be cleaned to expose the surface. Mark the spots for injection grouting. If leakage is through a crack, mark grouting points along the crack in a staggered manner. If the leakage is across the area mark grouting spots in a grid pattern. Drill grouting holes so as to neatly fit the injection packers. Drilling to be done at an angle of 45 to the plane of grouting surface. Fix PVC/MS nozzles in the low viscosity, injecting polyurethane resin/epoxy grout using a grouting pump. Repeat the process after 1 or 2 days if the leakage continues at some point. allow to cure for 24 hours and seal the grouting holes appropriately using epoxy putty etc complete all as specified and as directed.
Supply only Integral water proofing compound.
M&L PCC 1:4:8 Type D2 using 40mm graded coarse aggregate as in lean concrete/filling concrete.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and disposing the rubbish to the out side of MD land.
M&L for coloured non-skid ceramic tiles 7-8mm thick rectified glossy (square/rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11Sqm in floors etc , set and jointed in neat cement slurry and pointed in white or coloured cement to match over/ incl 15mm thick screed bed (1:6), complete all as specified and directed.
M&L for Glazed ceramic tiles coloured of size 450X 300X 7mm laid on vertical surface such as dado/skirting over cement mortar backing coat, set jointed in neat cement slurry and pointed in white or coloured cement including 15mm thick backing coat in CM 1:4, complete all as specified.
Taking down Cast iron pipe of dia upto 100mm fixed on wall or in floor including all fittings upto 15th floor of bldg. complete all as specified.
S&F 100 mm dia sand cast CI soil waste & vent pipe in any length with ears and jointed with neat cement paste fixed to wall upto 15th floor of bldg., complete all as specified.
Taking down Cast iron pipe of dia 100mm fixed on walls and re-fixed on wall including all fittings after cleaning properly and paint with bitumenious paint upto 15th floor of building complete all as specified.
Taking down Cast iron pipe of dia 75mm fixed on walls and re-fixed on wall including all fittings upto 15th floor of building complete all as specified.
S&F 75 mm dia sand cast CI soil waste & vent pipe in any length with ears and jointed with neat cement paste fixed to wall upto 16th floor of bldg, complete all as specified.
S&F 100 mm dia sand cast CI soil waste pipe in any length with or without ears and jointed with neat cement paste, laid in trenches or in floors.
S&F in repair 100mm cast iron Nahani / Floor trap with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) upto 15th floor of bldg, complete all as specified.
S&F in repair 100 mm dia sand cast CI bend of any radius with ovel access door and jointed with neat cement paste , complete all as specified.
S&F in repair 75 mm dia sand cast CI bend of any radius with ovel access door and jointed with neat cement paste, complete all as specified.
S&F in repair 100 mm dia CI branch piece single/double branch of any radius with ovel access door and jointed with neat cement paste , complete all as specified.
S&F in repair 75 mm CI dia branch piece single/double branch of any radius with ovel access door and jointed with neat cement paste, complete all as specified.
S&F in repair PVC Connections 15mm size with PTMT nuts of length 600mm
S&F as in repair WHB/Kitchen sink collapsible waste pipe out let upto Nahani trap complete.
S&F in repair 15mm pillar taps, cast copper alloy with capstan heads chromium plated screw down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed.
S&F in repair 10 ltr capaciaty PVC low level flushing cistern 10 litre capacity with 32mm bore polythene flush pipe of sufficient lenght including internal fitting (valve less syphonic) etc. upto 15th floor of bldg. complete.
Removing and refixing only high or low level flushing cistern (inclusive of brackets),and connection to pipes .
Removing and refixing Vitreous china wash basin white flat back any size, including all fitting arrangements complete.
S&F in repairs white vitreous china wash down water closet pan with PVC white seat cover with mild steel chromium plated or aluminised hinging device including connection to down pipe PVC connection and flushing pipe all as specified.
S&F in repairs, Plastic water closet seat covers, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device.
S&F in repair stainless steel grating cover fixed in repairs to suit the 100mm/75mm dia nahani trap fixed with cement,complete all as specified.
S&F as in repairs Wash hand basin vitreous china White flat back size 550mmx400mm including cast iron brackets, chromium plated waste coupling, PVC connection, waste pipe up to floor trap etc in repair all complete as specified.
S&F as in repairs 15mm bore CP Stop valves/ angular stop valve, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed, complete all as specified and directed.
Supply and fix repairs in fancy concealed type stop valve with long shark and adjustable wall flange including union suitable for 15mm bore GI/upvc pipe complete all as specified and directed
S&F in repairs CP bib cock 15 mm bore complete all as specified and directed.
S&F in repairs Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.00 metre long spirochrome Flexible tube and wall hook including making connections and fixed in position complete all as specified and directed.
S&F in repairs aluminium anodised tubular towel rail 20mm dia D type 60 cm long between flanges , complete all as specified.
S&F in repairs brass chromium plated shower rose 125mm size, including fixed to steel tube, complete all as specified.
Taking down and refixing 15mm bore stop cock / bib tap/ pillar tap/shower/ health faucet etc. to iron /CPVC pipe,including repairing complete all as specified.
S&F in repair 100mm dia CI sanitary connection- short connections pipe of length upto 300mm
S&F in repair Vitreous water closet (orissa pattern) white , front or back inlet any pattren, including provision of cement concrete bedding complete all as directed.
S&F in repair Cast iron floor trap 75 mm dia, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) all as specified.
Removing and refixing only Vitreous china EWC pedestal pattern complete any size complete.
Resecuring or easing & adjusting without taking down shutters of any description exc 1 sq. m and n exc 2 sq. m Each
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water, upto 15th floor of bldg.,complete all as specified.
M&L for Rendering 15mm thick cement plaster in cement mortor 1:6 on brick or concrete surfaces in patches, surfaces to be finished even and smooth without using extra cement,upto 15th floor of bldg, complete all as specified.
M&L for plastering 10mm thick in CM 1:3 in ceiling finishing even and smooth without using extra cement, upto 15th floor of bldg, complete all as specified.
M&L for Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and fair including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions & upto 15th floor of bldg, complete all as specified.
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat primer on 2mm thickness wall care putty all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash on ceiling complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of exterior emulsion paint over a coat of primer on wall complete all as specified and directed.( Work carried out upto 15th floor of building from outside)
Taking down chowkats or frames area n exc 1.5 sqm Each but with shutters (without taking off shutters from the frame)
S&F Factory made single extruded WPC (WoodPolymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45 x 85 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp?ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and directed.
M&L for factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screwsand as per specification & drawing complete all as specified and directed.
S&F butt hinges 100 mm mild steel hinges medium weight and fixed.
S&F 150 mm size aluminium alloy handles, cast type anodised, ISI marked all as specified.
S&F for aluminium anodized barrel tower bolts 150 mm of extruded section and fixed.
S&F in repairs low density polyethylene pipes (LDPE) of pressure rating 6 kg/cm2 fixed complete to walls, ceilings or in floors etc for outlet of washing machine/wash basin etc of 40 mm dia bore complete all as specified and as directed.
Taking down & Refixing 15mm old steel tubing and connections in new or old position (Walls, ceiling,floors, etc.), complete all as specified.
S&F in repair GI water tubing 15mm bore medium grade (ISI marked) including with all fittings and fixed to wall /ceilings laid in floor or concealed upto 16th floor of bldg. including taking down old GI tubing complete all as specified and directed.
S&F in repair 20mm bore of CPVC pipes having thermal stability for hot & cold water supply including all plain and brass threded fittings fixed of required sizes including with all fittings and fixed to wall /ceilings with suitable clamps, laid in floor or concealed of 20mm size (in high rise building (upto 16th floor) including scaffolding). complete all as specified and directed by Engineer-in-Charge.
S&F as in repairs 15mm fancy type chromium plated Two way Bib taps, of approved make cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair Toilet paper holder along with cover of stainless steel suitable for 120mm width and 100mm depth long paper fixed to walls sample approved by GE.
S&F in repairs Stainless Steel Soap Dish as approved fancy type fixed with two Steel/ CP Screws complete all as specified and directed
S&F in repair PVC cabinet mirror 450X300 mm with 3 mm thick mirror, complete all as specified and as directed.
S&F in repair decorative glass corner shelf round 10mm thick, 300mm size with stainless steel railing, fixed with D type stainless steel bracket on wall of approved design and pattern all as specified.
Taking down eaves gutters and rainwater pipes of any dia (any size or pattern ) including all fittings, heads, shoes, bends, swan necks etc (Measured overall as fixed along the centre line over fittings and accessories) & ht. upto 16th floor of bldg., complete all as specified.
S&F 160 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including fixing clips, bends, elbows, shoes etc & ht. upto 16th floor of bldg., complete all as specified.
S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including fixing clips, bends, elbows, shoes etc & ht. upto 16th floor of bldg., complete all as specified.
S&F PVC (SWR) bends of 160 mm bore & ht. upto 16th floor of bldg., complete all as specified.
S&F PVC (SWR) bends of 110 mm bore & ht. upto 16th floor of bldg., complete all as specified.
M & L for washing, rubbing down and stopping of distempered and painted old plastered surfaces of walls and apply two coat distemper oil emulsion over a coat of primer over a coat 2 mm thick wall care putty, complete all as specified.
M&L for preparation of old wall surfaces and applying two coats of oil emulsion distemper complete all as specified and directed.
M&L preparation of old distempered surfaces of walls and applying one coat of oil emulsion distemper on walls etc all as specified.
M&L for applying one coat of oil emulsion distemper on ceiling incl preparation of surfaces all as specified and directed. .
M&L for light shade coloured vitrified ceramic tiles 10 mm thick (square/rectangular) polished area of Each tiles not exceeding 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointee in white or coloured cement to match incl 15 mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for light shade coloured vitrified ceramic tiles 10 mm thick (square/rectangular) polished area of Each tiles not exceeding 0.36 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match as in skirting incl 15mm thick backing coat in CM 1:4 complete all as specified and directed.
M & L for glazed ceramic tiles in patches, area n exc 5 sq.m. including removing and cleaning old tiles, preparing beds and laying or setting, jointing and pointing new or old tiles, incl 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for applying white cement mixed with polymer base water proofing compound inside the floor/nahani trap and inside P/S trap, complete all as specified and directed.
M&L for preparation of old painted wooden surfaes of any description over 10cm width or girth and applying one coat of synthetic enamel paint including external window with necessary scafolding for high rise bldgs.
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint & ht. upto 16th floor of bldg, complete all as specified.
Supply and fix in repair white rectangular PVC water storage tanks (Loft tank) of capacity 300Ltrs with complete fitting including fixing 03 Nos tank nipples of GI/ PPR with washer for out let and inlet all as per manufacturers instructions including disconnecting service connections/over flow pipes and removing old tank complete all as specified and directed.
Supply and fix in repair PVC modular 20mm thick as in proflie including 'C' channels, aluminium U clip all around the profile suitable for 300 ltr capacity loft tank ,complete all as specified and directed.
Dismantling wrought iron or mild steel works of any description work etc.
Supply and fix Mild steel angle iron section (Fe 290 Gde E 165) fixed independently, without connecting plates, etc incl cutting to required length, drilling, welding etc and embedding in Brick work incl Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 as required as in loft Water tank base in bathrooms/kitchens etc complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described, and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
Supply and fix in repair brass float valve flat type of size 15 mm bore, high pressure with polythene float & fly nut complete, screwed for GI pipe of following sizes including necessary GI fittings complete all as specified.
M&L for post construction anti termit treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified and directed.
I.J Enterprises (BID ID -3474881)
SATGURU ENTERPRISE (BID ID -3475887)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
tenderpages8457.pdf
Tender Documents • 1.12 MB
BOQ_825475.xls
BOQ • 1.77 MB
Download all tender documents and submit your bid