Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC | ₹29.9 L | L1 | Accepted-AOC Lowest Tender |
| 2 | L2₹31.1 LRejected-AOC | ₹31.1 L | L2 | Rejected-AOC Second Lowest Tender |
| Sl No | Description | Qty | Unit | BHARAT CORP L1 | GAJENDRAA ELECTRIC COMPANY L2 |
|---|---|---|---|---|---|
| 1.00 | Charges for removing the HT & LT Cable connections of the 11 KV/433 Volts 500 KVA transformer, shifting the transformer from the one sub-station to the alternate substation with necessary crane arrangements, man power, Puller, Tripods etc. and positioning ,erection of the same in by constructing new PCC bed with suitable size & position suitable for cable terminations all as complete as instructed by PWD officials | 2 | Job | 1,10,000 ₹2.2 L | 1,50,000 ₹3 L |
| 2.00 | Charges for reconnecting all the existing Incoming and Outoging HT< cables, Neutral Connection, Body Earth Connections for the newly erected transformer including testing and precommissioning the same all as complete as instructed by PWD officials | 2 | Job | 32,500 ₹65,000 | 32,500 ₹65,000 |
| 3.00 | Charges for removing the existing 4 panel VCB 11 KV/433 Volts 630A panel, shifting from the one sub-station to the alternate substation with necessary crane arrangements, man power, Puller, Tripods etc. and positioning ,erection of the same in by constructing new PCC bed for cable terminations all as complete as instructed by PWD officials | 1 | Job | 62,500 ₹62,500 | 63,000 ₹63,000 |
| 4.00 | Hiring Charges for 500KVA DG set for temporary backup power supply arrangements for one day SR | 2 | Nos | 13,400 ₹26,800 | 13,500 ₹27,000 |
| 5.00 | Hiring Charges for 3.5Cx 185 Sqmm LTUG cable for temporary supply arrangements SR | 70 | Mtrs | 22 ₹1,540 | 22 ₹1,540 |
| 6.00 | Supply and Laying of 3C x 300 Sq.mm. 11 KV HT XLPE cable in a suitable 6" duro pipe to be excavated at a depth of 1 metre and covering the cable completely and refiling the earth to make good.(Make Gloster/Havells/ Polycab) | 253 | mts | 3,335 ₹8.4 L | 3,340 ₹8.5 L |
| 7.00 | Supply and fixing of HEAT SHRINKABLE HT CABLE JOINT KIT CONSISTS OF RIGHT ANGLE / STRAIGHT BOOTS, WRAP AROUND SLEEVES, INSULATION TAPE, BUTYL SEALANT, CONSTANT FORCE SPRING, CLAMPS, TINNED COPPER BRAIDS ETC., of size 240-300 sq.mm. 3 core HT Cable Indoor Terminations XLPE 11KV (E) - EPKT 3121 | 4 | Nos. | 16,196 ₹64,784 | 16,200 ₹64,800 |
| 8.00 | Supply and Laying of 2 run of 3 1/2 x 300 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good. | 331 | Mtr | 3,732 ₹12.4 L | 3,800 ₹12.6 L |
| 9.00 | Supply and fixing of brass cable gland for 3-1/2 x 300 sq.mm. PVC armoured LTUG cable with earth connection. | 8 | Nos | 946 ₹7,568 | 950 ₹7,600 |
| 10.00 | Supply and providing cable end termination of 3-1/2x300 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete | 8 | Nos | 866 ₹6,928 | 870 ₹6,960 |
Updated dates
Tender Value
Refer Docs
EMD Value
₹25,000
Closing Date
28 Jan 2026, 3:00 pmClosed
The Superintending Engineer, PWD.,
O/o. The Superintending Engineer, PWD., Buildings (C and M) Circle-1, Chepauk, Chennai-5
Sub Work. Shifting, relocation of Transformers, VCB panels including allied works for Construction of Emergency Care Block at Govt. Stanley Hospital, Chennai-01
2026_PWD_644510_1
PWD/BCMC1/98-1/2025-26
Open Tender
Electrical Works
60 days
Stanley Medical and Hospital
Refer Tender Condition
8 documents required · 8 mandatory
₹0
₹25,000
1 Apr 2026
19 Jan 2026
28 Jan 2026
19 Jan 2026
28 Jan 2026
19 Jan 2026
Charges for removing the HT & LT Cable connections of the 11 KV/433 Volts 500 KVA transformer, shifting the transformer from the one sub-station to the alternate substation with necessary crane arrangements, man power, Puller, Tripods etc. and positioning ,erection of the same in by constructing new PCC bed with suitable size & position suitable for cable terminations all as complete as instructed by PWD officials
Charges for reconnecting all the existing Incoming and Outoging HT< cables, Neutral Connection, Body Earth Connections for the newly erected transformer including testing and precommissioning the same all as complete as instructed by PWD officials
Charges for removing the existing 4 panel VCB 11 KV/433 Volts 630A panel, shifting from the one sub-station to the alternate substation with necessary crane arrangements, man power, Puller, Tripods etc. and positioning ,erection of the same in by constructing new PCC bed for cable terminations all as complete as instructed by PWD officials
Hiring Charges for 500KVA DG set for temporary backup power supply arrangements for one day SR
Hiring Charges for 3.5Cx 185 Sqmm LTUG cable for temporary supply arrangements SR
Supply and Laying of 3C x 300 Sq.mm. 11 KV HT XLPE cable in a suitable 6" duro pipe to be excavated at a depth of 1 metre and covering the cable completely and refiling the earth to make good.(Make Gloster/Havells/ Polycab)
Supply and fixing of HEAT SHRINKABLE HT CABLE JOINT KIT CONSISTS OF RIGHT ANGLE / STRAIGHT BOOTS, WRAP AROUND SLEEVES, INSULATION TAPE, BUTYL SEALANT, CONSTANT FORCE SPRING, CLAMPS, TINNED COPPER BRAIDS ETC., of size 240-300 sq.mm. 3 core HT Cable Indoor Terminations XLPE 11KV (E) - EPKT 3121
Supply and Laying of 2 run of 3 1/2 x 300 sq.mm. PVC armoured LTUG cable in suitable size HDPE pipe in a trench to be excavated at a depth of 0.75 metre and refilling the earth to make good.
Supply and fixing of brass cable gland for 3-1/2 x 300 sq.mm. PVC armoured LTUG cable with earth connection.
Supply and providing cable end termination of 3-1/2x300 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_772405.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.13 MB
Shiftingtransformerstanley.pdf
Tender Documents • 0.74 MB
BOQ_772405.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid