Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC AT BAGHUABOL CHHAK PO HATATOTA TALCHER ANGUL ODISHA PIN 759100 | ANUGUL | ODISHA | 759100 | L1 | Accepted-AOC techno commercially eligible L1 bidder | |
| 2 | L2₹8.4 L+₹1.1 L (15.6%)Rejected-Finance AT GURUDHWAR NEAR UCO BANK SOUTH BALANDA TALCHER DIST ANGUL ODISHA PIN 759116 | TALCHER | ANGUL | ODISHA | 759116 | L2 | Rejected-Finance REJECTED FOR NOT BEING L1 |
Tender Value
₹17.9 L
EMD Value
₹22,500
Closing Date
26 Nov 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer(EnM), Jagannath Area, MCL
Jay Prakash, Staff Officer(EnM), Jagannath Area, MCL PH 06760-269717, 06670-269751(Extn)2023 Fax 06760-269527 E-mail so-enm-jaga.mcl(at)coalindia.in
Day to day repairing, maintenance and testing of various 3.3 kV and 6.6 kV starters, breakers and field switches of Ananta OCP for a period of 365 days.
2024_MCL_320743_1
GM(JA)/EnM/e-Tender/24-25 /E-702/67 DTD. 07/11/24.
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
talcher
AS PER NIT
5 documents required · 5 mandatory
₹22,500
17 Mar 2025
8 Nov 2024
29 Nov 2024
9 Nov 2024
26 Nov 2024
9 Nov 2024
9 Nov 2024 - 14 Nov 2024
Amount
For 3.3 kV & 6.6 kV, 200 KW- 650 KW Starters
Supply of complete Isolator (On-Off triple pole) as per requirement
Supply of Limit Switch for Isolator as per requirement
Supply of Vaccum interrupter bottle as per requirement
Supply of Closing coil /tripping coil for contactor as per requirement
Supply of Core balance Transformer as per requirement
Supply of 3 Phase CT operated overload relay with mounting kit as per requirement
Supply of DC pack for closing coil as per requirement
Supply of suitable HTTB bushing as per requirement
Supply of HT PT fuse as per requirement
Supply of Control Fuse as per requirement
Supply of Auxilary contactor as per requirement
Supply of Cable Gland as per requirement
Supply of Ammeter as per requirement
Supply of Voltmeter as per requirement
Supply of 3 Ph Potential Transformer 3.3 kV /220 V as per requirement
Supply of Current Transforemer as per requirement
Supply of Push Button with element as per requirement
Supply of LED indication lamp as per requirement
Supply of Control cable 2.5 Sq. mm as per requirement
Labour Cost for repairing of 3.3 kV & 6.6 kV, 200 KW- 650 KW Starters
Major repairing work of HT starter: Dismantling , maintenance & installation of HT Vaccum contactor unit with vaccum bottle, isolator, CT , PT, Cable gland , Ammeter & Voltmeter etc. with necessary wiring as per the requirement.
Minor repairing work of HT starter: Testing of control Circuit and protective devices along with replacement of defunct spares for smooth working of HT starter as per the requirement.
For 3.3 kV & 6.6 kV, 200 A- 1250 A Circuit Breakers & Field switches
Supply of shunt trip coil assembly as per requirement.
Supply of Electrical release coil assembly as per requirement.
Supply of Auxilary Switch assembly as per requirement.
Supply of Solenoid coil 110V DC as per requirement.
Supply of Anti pumping Relay for solenoid as per requirement.
Supply of Closing contact for solenoid 110 V DC as per requirement.
Supply of Push to trip assembly as per requirement.
Supply of complete Vacuum interrupter 1250A as per requirement.
Supply of Operating mechanism for VCB as per requirement.
Supply of Springs for operating mechanism as per requirement.
Supply of indicating Lamp as per requirement.
Supply of Push buttons as per requirement.
Supply of TNC Switch as per requirement.
Supply of Rectifier Capacitor unit 63A as per requirement.
Supply of High speed triping Relay (Master trip) as per requirement.
Supply of 3PH Potiential Transformer as per requirement.
Supply of Auxilary contactor as per requirement.
Supply of IDMT 3 O/C & 1 E/F relay, AUX 110V AC/DC, 5A as per requirement.
Supply of Cable gland cone (Brass) - Wipen type as per requirement.
Supply of Power factor meter as per requirement.
Supply of Copper Busbar 50mmX8mm as per requirement.
Supply of Copper Busbar 25mmX6mm as per requirement.
Supply of Ammeter 96 sq.mm as per requirement.
Supply of Voltmeter 96 sq.mm as per requirement.
Supply of Surge suppressor 3KV,5KA as per requirement.
Supply of KWH meter as per requirement.
Supply of Spring charging motor as per requirement
Supply of Limit switch 1NO+1NC as per requirement
Supply of Earthing Bush as per requirement
Supply of E/L relay with CBCT as per requirement
Supply of TNR switch as per requirement.
Labour Cost for repairing of 3.3 kV & 6.6 kV, 200 A- 1250 A Circuit Breakers & Field switches
Dismantling,cleaning.maintenance of 3.3 kV & 6.6 kV VCB & OCB Units & checking of its moving & fixed contacts,incoming and outgoing Bus Bar connection with overhauling of its spares for smooth operation.
Dismantling,cutting,welding & maintenance of Panel body with base plate,doors,covers,incoming and outgoing joint boxes etc as required.
Minor repairing with testing of control circuit & protective devices for smooth working to ensure the effectiveness wheather the vcb panels are tripping during faulty conditions.
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
M/s Evergreen Electrical Works (BID ID -1102739)
techsummary_332477.pdf
PDF • 0.57 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_332477.pdf
PDF • 0.48 MB
LOAE702.pdf
PDF • 3.74 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .