| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.8 LAccepted-AOC B 20 H 1 PANCHANANTALLA ROAD KOLKATA 700029 | KOLKATA | WEST BENGAL | 700029 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹47.8 L+₹77,830 (1.65%)Rejected-Finance 139 B B SEN ROAD CHANDANNAGAR HOOGHLY WEST BENGAL 712136 | CHANDANNAGAR | HOOGHLY | WEST BENGAL | 712136 | L2 | Rejected-Finance Being higher bid value | |
| 3 | L3₹49.2 L+₹2.1 L (4.50%)Rejected-Finance 22 2 BAKRAHAT ROAD THAKURPUKUR KOLKATA 700063 | KOLKATA | KOLKATA | WEST BENGAL | 700063 | L3 | Rejected-Finance Being higher bid value | |
| 4 | L4₹49.3 L+₹2.3 L (4.84%)Rejected-Finance | L4 | Rejected-Finance Being higher bid value | |
| 5 | L5₹49.4 L+₹2.4 L (5.10%)Rejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L5 | Rejected-Finance Being higher bid value |
Tender Value
₹42.5 L
EMD Value
₹85,000
Closing Date
31 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE ALIPORE KOLKATA
NO 1 NATIONAL LIBRARY AVENUE, ALIPORE, KOLKATA 700027
8019/B/E8
2021_MES_492302_1
GE/ALP (8019B) OF KOLKATA 2021-22
Open Tender
Civil Works
Item Rate
210 days
GE ALIPORE KOLKATA
Class D and Category b (i)
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER ALIPORE
₹85,000
Yes
7 Feb 2022
3 Dec 2021
1 Jan 2022
3 Dec 2021
31 Dec 2021
24 Dec 2021
60 days
Amount
Excavation in trenches n. exc 1.5 m wide and n.exc 1.5 m in depth for foundation or for laying of cable, fixing of pole etc and getting out in soft/loose soil complete all as specified and as directed by the Engr-in-Charge.
Material and labour for sand filling around the cable with approved quality coarse sand for sand cushioning of Under ground cable including spreading and punning down to desired thickness complete all as specified and as directed by the Engr-in-Charge.
Supply and laying for burnt brick sub class 'B' locally available best quality laid in trenches for protections of under ground cable complete all as specified and as directed by the Engr-in-Charge .
Returning, filling in, trenches including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed by the Engr-in-Charge.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level, not exceeding 1.5 metre above the starting point complete all as specified and as directed by the Engr-in-Charge.
Material and labour for plain cement concreate (1:3:6), type C2 (using 40 mm graded stone aggregate) as in foundations, filling, coping for pole and mass concreate complete all as specified and as directed by the Engr-in-Charge
Cutting existing metal/bituminus road/PCC walk way/any type of tile works n.exc 0.45m width and n.exc 0.90 m in depth including all connected earth work and making good disturbed surfaces matching with the existing specification and finish including disposal of surplus material to a distance n.exc 50m complete all as specified and as directed by Engr-in-Charge.
S&F in repair 50mm dia Tubes, 'light grade' galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed
S&F in repair Galvanised iron tubing 80 mm dia light grade laind in trenches/floors/walls for earth lead protection and cables at road crossing etc complete all as specified and directed.
S&F in repair Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required with 25X4 mm galvanised iron strip.
Supply and laying for under ground heavy duty XLPE insulated, armoured aluminium conductor cable 1100 volts grade, cross-sectional area 25 sq. mm 4 core in trenchches / through pipe or bare in road crossing / plingth/ drain/ duct/ floor along pole / wall /ceillings etc after and including disconnecting and taking out of existing unserviceable cable complete all as specified and directed by the Engr- in- Charge. Note:- Earth work, bricks protection sand cuisioning shall be measured and paid seperately.
All as per item No 11 above but of size 35 sqmm 3.5 core .
All as per item No 11 above but of size 50 sqmm 3.5 core .
All as per item No 11above but of size 70 sqmm 3.5 core .
All as per item No 11 above but of size 95 sqmm 3.5 core .
All as per item No 11 above but of size 120 sqmm 3.5 core .
All as per item No 11 above but of size 185 sqmm 3.5 core .
All as per item No 11 above but of size 240 sqmm 3.5 core .
Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint cold shrink complete with Jointing material cold Shrinkable and accessories suitable for 3.5 core XLPE, armoured, aluminium conductor cable of size 25 to 50 sqmm complete all as specified and directed by the Engr- in- Charge.
All as per item No 19 above but of size 70 to 120 sqmm 3.5 core .
Dismantling of old unserviceable Panel and Supply & fabrication of LT Panel Board CPRI approved cubical type of size 1200mmx1000mmx450mm to accomodate under mentioned accessories, made out of 2 mm thick CRCA sheet indoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Copper bus bar of 600 Amps capacity for each phases and half for neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No, CTs of suitable ratio, suitable size single core copper wire for internal connection from bus bar to MCCB and Indicating LED type lamp for Red, Yellow and Blue in incomer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations complete testing and commissioning complete and consisting of the following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work and Taking down old unsv from site as directed by Engr-In-Charge) (19 PH) (a) MCCB 4 Pole Adjustable thermal magnetic type 400 Amps 36 KA -01 No. (as Incoming) (b) MCCB 4 Pole Adjustable thermal magnetic type 250 Amps 36 KA -03 Nos. (connected-02 & Spare-01) (as Outgoing) (c) Onload Change over switch 250A, 4 pole - 01 No Make-L&T/Schneider/ABB/Havells
Dismantling of old UNSV Panel and Supply & fabrication of LT Panel Board CPRI approved cubical type of size 1200mmx1000mmx450mm to accomodate under mentioned accessories made of 3 mm thick CRCA steel outdoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Copper bus bar of 600 Amps capacity for each phases and half for neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No, CTs of suitable ratio, suitable size single core copper wire for internal connection from bus bar to MCCB and Indicating LED type lamp for Red, Yellow and Blue in incomer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations complete testing and commissioning complete and consisting of the following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work and Taking down old unsv from site as directed by Engr-In-Charge) (children park) (a) MCCB 4 Pole Adjustable thermal magnetic type 400 Amps 35KA -01 No. (as Incoming) (b) MCCB 4 Pole Adjustable thermal magnetic type 125 Amps 25KA -05 No. (connected-04 & Spare-01)(as Outgoing) Make-L&T/Schneider/ABB/Havells
Dismantling of old unserviceable Panel and Supply & fabrication of LT Panel Board CPRI approved cubical type of size 1800mmx1700mmx450mm to accomodate mentioned accessories made of 2 mm thick CRCA sheet indoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Aluminium bus bar of 500 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No, CTs of suitable ratio, suitable size single core copper wire for internal connection from bus bar to MCCB and Indicating LED type lamp for Red, Yellow and Blue in incomer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations, testing and commissioning complete and consisting of the following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work. (KMC) (a) MCCB Adjustable thermal magnetic type 4 Pole 315 Amps 35 KA -01 No. (as Incoming) (b) MCCB Adjustable thermal magnetic type 4 Pole 250 Amps 35KA -01 No. (as Outgoing) (c) MCCB Adjustable thermal magnetic type 4 Pole 200 Amps 25KA -02 Nos (connected-01 & Spare-01) (as Outgoing) (d) MCCB Adjustable thermal magnetic type 4 Pole 25-63 Amps 16KA -03 Nos (as Outgoing) Make-L&T/Schneider/ABB/Havells
Dismantling of old unserviceable Panel and Supply & fabrication of LT Panel Board CPRI approved cubical type of size 1800mmx1700mmx450mm to accomodate mentioned accessories made of 2 mm thick sheet steel indoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Aluminium bus bar of 500 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No, CTs of suitable ratio, suitable size single core copper wire for internal connection from bus bar to MCCB and Indicating LED type lamp for Red, Yellow and Blue in incomer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations, testing and commissioning complete and consisting the following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work. (a) MCCB 4 Pole Pole Adjustable thermal magnetic type 320 Amps 35KA -01 No. (as Incoming) (a) MCCB 4 Pole Pole Adjustable thermal magnetic type 250 Amps 35KA -01 No. (as outgoing) (b) MCCB 4 Pole Pole Adjustable thermal magnetic type 160 Amps 25 KA -01 No. (as Outgoing) (c) MCCB 4 Pole Pole Adjustable thermal magnetic type 100 Amps 25KA -02 Nos (connected-01 & Spare-01) (as Outgoing) (d) MCCB 4 Pole Pole Adjustable thermal magnetic type 63 Amps 16KA -03 Nos (as Outgoing) Make-L&T/Schneider/ABB/Havells
Dismantling of old unserviceable Panel and Supply & fabrication of LT Panel Board CPRI approved cubical type of size1500mmx1400mmx450mm to accomodate mentioned accessories made of 3.15 mm thick sheet steel indoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Aluminium bus bar of 500 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No, CTs of suitable ratio, suitable size single core copper wire for internal connection from bus bar to MCCB and Indicating LED type lamp for Red, Yellow and Blue in incomer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations, testing and commissioning complete and consisting the following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work. (a) MCCB 4 Pole Pole Adjustable thermal magnetic type 250 Amps 35KA -01 No. (as Incoming) (b) MCCB 4 Pole Pole Adjustable thermal magnetic type 125 Amps 25 KA -04 No. (as Outgoing) (c) MCB SPN 32 Amps 10KA -04 Nos (as Outgoing) Make-L&T/Schneider/ABB/Havells
Dismantling of old unserviceable Panel and Supply & fabrication of LT Panel Board CPRI approved cubical type of size 1500mmx1400mmx450mm to accomodate mentioned accessories made of 3.15 mm thick sheet steel indoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Copper bus bar of 500 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No, CTs of suitable ratio, suitable size single core copper wire for internal connection from bus bar to MCCB and Indicating LED type lamp for Red, Yellow and Blue in incomer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations, testing and commissioning complete and consisting the following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work. (a) MCCB 4 Pole Pole Adjustable thermal magnetic type 250 Amps 35KA -02 No. (as Incoming) (b) MCCB 4 Pole Pole Adjustable thermal magnetic type 125 Amps 25 KA -03 No. (as Outgoing) (c) Onload changeover switch 250 Amps 4 pole -01 Nos (as incomer) Make-L&T/Schneider/ABB/Havells
Dismantling of old unserviceable Panel and Supply & fabrication of LT Panel Board CPRI approved cubical type of size 1800mmx1700mmx450mm to accomodate mentioned accessories made of 2 mm thick sheet steel indoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Aluminium bus bar of 600 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No, CTs of suitable ratio, suitable size single core copper wire for internal connection from bus bar to MCCB and Indicating LED type lamp for Red, Yellow and Blue in incomer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations, testing and commissioning complete and consisting the following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work. (a) MCCB 4 Pole Pole Adjustable thermal magnetic type 400 Amps 35KA -02 No. (as Incoming) (b) Onload Changeover switch 400 Amps 4 pole - 01 No (c) MCCB 4 Pole Pole Adjustable thermal magnetic type 250 Amps 35KA -01 No. (as outgoing) (d) MCCB 4 Pole Pole Adjustable thermal magnetic type 200 Amps 35 KA -04 No. (as Outgoing) (e) MCCB 3 Pole Pole Adjustable thermal magnetic type 100 Amps 25KA -03 Nos (as Outgoing) Make-L&T/Schneider/ABB/Havells
Dismantling of old unserviceable Panel and Supply & fabrication of LT Panel Board CPRI approved cubical type of size 1000mmx900mmx450mm to accomodate mentioned accessories made of 3.15 mm thick sheet steel indoor type with IP 67 grade of protection CRCA sheet powder coated with support of angle iron of 50 x 50 x 6 mm angle iron bottom legs with minimum height of 20 cm frame with double hinged front openable shutters of each feeder control unit with locking arrangement in front and back openable inspection doors PVC sleeved Aluminium bus bar of 400 Amps capacity for each phases and half neutral fixed on suitable insulator all housed in suitable bus bar chamber and cable alloy including provision and fixing of digital Voltmeter -01 No, Ammeter-01 No, CTs of suitable ratio, suitable size single core copper wire for internal connection from bus bar to MCCB and Indicating LED type lamp for Red, Yellow and Blue in incomer phases complete along with provision of necessary cable entry/exit boxes for all incoming and out going cables with suitable cable glands etc fixed on suitable PCC foundations, testing and commissioning complete and consisting the following :- (Drawing of Panel and connections shall be approved by Engr-in-Charge before starting the panel work. (a) MCCB 4 Pole Pole Adjustable thermal magnetic type 250 Amps 35KA -01 No. (as Incoming) (b) MCB SPN 20 Amps 10 KA -12 Nos. (as Outgoing) (c) SSC 15 Amps -12 Nos Make-L&T/Schneider/ABB/Havells
Servicing of capacitor panel upto 700 KVAR and checking of capacitance of capacitor including control & power wiring complete cleaning of spares parts including testing of relay & contactor, tighting of nuts/bolts etc of any capacity after taking shutdown as per electrical safety norms complete all as directed by Engineer-in-Charge Note : Spares will be measured and paid saparetely
Supply only capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 5 KVAR capacity. Make : L& T/Neptune/C&S
Supply and fixing capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 10 KVAR capacity. Make : L& T/Neptune/C&S
Supply and fixing capacitor metalized poly propylene heavy duty (MPP-H) for 3 phase ,440 V, 50 Hz System for permissible non- linear load 15% of 20 KVAR capacity. Make : L& T/Neptune/C&S
S&F MCCB 63 Amps, 10 KA 4-Pole type, including all arrnagement for mounting and testing, operating on 415V, 50Hz , AC supply, including taking down of old unserviceable one complete all as specified and directed.
S&F MCCB 100 Amps, 10 KA 4-Pole type, including all arrnagement for mounting and testing, operating on 415V, 50Hz , AC supply, including taking down of old unserviceable one complete all as specified and directed.
S&F MCCB 125 Amps, 16 KA 4-Pole type, including all arrnagement for mounting and testing, operating on 415V, 50Hz , AC supply, including taking down of old unserviceable one complete all as specified and directed.
S&F MCCB 160 Amps, 25 KA 4-Pole type, including all arrnagement for mounting and testing, operating on 415V, 50Hz , AC supply, including taking down of old unserviceable one complete all as specified and directed.
S&F MCCB 200 Amps capacity 4 pole 25 KA breaking capacity complete all as specified and directed by Engineer-in-Charge.
S&F MCCB 250 Amps capacity 4 pole 25KA breaking capacity complete all as specified and directed by Engineer-in-Charge.
S&F MCCB of 400 Amps capacity 4 pole 36KA breaking capacity complete all as specified and directed by Engineer-in-Charge.
S&F of sheet metal Enclosure suitable for fixing of MCCB's, 3P/4P of any type and capacity complete all as specified and directed by Engr-in-Charge.
Isolate, disconnect, dismantle the burnt out lugs from the main connections and crimping with proper new 240 Sqmm alluminium lugs and glands as per existing one including fixing insulation tape termination to main connections of LT cables complete all as specified and directed by Engr-in-charge.
All as per item No 42 above but for 120 Sqmm/150 Sqmm/185 Sqmm lugs.
All as per item No 42 above but for 50/70/95 Sqmm Lugs.
Supply and fixing as in replacement LED digital Voltmeter range 0-500 V, 3 phase Cl 0.5 including replacement of old unserviceable one complete all as specified and as directed. Make : L&T Cat No. WL 132020OOOO or equivalent in AE/ Schneider.
Supply and fixing as in replacement LED digital Ammeter range 0- 500 Amps, 3 phase Cl 0.5 including replacement of old unserviceable one complete all as specified and as directed. Make : L&T Cat No. WL 131020OOOO or equivalent Iin AE/ Schneider.
Supply and fixing as in replacement CT 400/5, 10 VA accuracy class 0.5 including replacement of old unserviceable one complete all as specified and as directed. Make : AE/ Kappa.
Material and labour for painting of panel board of any size at verious locations with two coats of superior quality synthetic enamel paint first grade including cleaning of existing surface of all loose darts and greasy spots and marking of incoming feeder and outgoing feeder with letters n. exc 15 cm height and necessary disconnection of electric connection and reconnection of same after completion of painting work complete all as specified and as directed by the Engr -in -Charge. Note :- Superficial area for the pourpose of painting shall be consider not greater than 15 sqm
Material and labour for painting of panel board of any size at verious locations with two coats of superior quality synthetic enamel paint first grade including cleaning of existing surface of all loose darts and greasy spots and marking of incoming feeder and outgoing feeder with letters n. exc. 15 cm height and necessary disconnection of electric connection and reconnection of same after completion of painting work complete all as specified and as directed by the Engr -in -Charge. Note :- Superficial area for the pourpose of painting shall be consider not greater than 6sqm
Material and labour for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised iron strip of size 32 x 6 mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded stone aggregate), 50mm thick precast RCC (1:2:4), type B1 cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C both ways and suitable handle made of 10mm dia M.S. round bar including necessary earth work in excavation, in soft/loose soil returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge.
CHATTERJEE CONSTRUCTION
ELECTRO FREEZE
CHOWDHURY SMALL INDUSTRIES
M/S J S ENTERPRISES
SEN ELECTRIC WORKS
M. M. C. AND CO
SUDHA ENTERPRISES
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .