Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹22.8 LAccepted-AOC | 1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | 2₹23.2 L+₹43,186.50 (1.90%)Rejected-Finance | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹23.9 L+₹1.1 L (4.90%)Rejected-Finance STREET NO 10 MALLOMAZRA ROAD BHAKHRA ENCLAVE PATIALA PB | PATIALA | PUNJAB | 140401 | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹25.1 L+₹2.3 L (10.2%)Rejected-Finance 300 PREM BASTI 10 SANGRUR SANGRUR PUNJAB 148001 | SANGRUR | PUNJAB | 148001 | 4 | Rejected-Finance NOT LOWEST | |
| 5 | 5₹25.1 L+₹2.3 L (10.2%)Rejected-Finance | 5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
1 Jul 2022, 6:00 pmClosed
MAJOR ANIMESH TRIPATHI
GE NORTH PATIALA MILITARY ENGINEER SERVICES SANGRUR ROAD PATIALA CANTT
REPAIRS AND MAINTENANCE OF INTERNAL WIRING AS WELL AS ATTEND MAINTENANCE PROGRAMME MD ACCN CENTRAL AMENITIES AT OLD CANTT AREA UNDER GE N PATIALA AT MIL STN PATIALA
2022_MES_521200_2
GE(N)/PAT-04/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
PATIALA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE NORTH PATIALA
₹70,000
Yes
18 Aug 2022
10 Jun 2022
4 Jul 2022
10 Jun 2022
1 Jul 2022
17 Jun 2022
Amount
Taking down carefully existing points wiring on surface conduit/concealed conduit for light/ fan/socket /power/ bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, piece of wires,gutties, conduit, wooden boards etc and making good the disturbed portion of all floor, ceiling etc all as specified and directed.
M & L for point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH(FLAME RETARDANT LOW SMOKE AND HALOGEN) single core multi-stranded copper conductor for one light/fan and including PVC rigid concealed conduit medium grade 19/20 mm dia to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor controlled by one switch and/or one regulator including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment required for fitting of flush and junction boxes all as specified and directed (Switches and regulators shall be measured and paid for separately.) ( Wiring shall be done as per colour code in IS for phase, neutral and earth) (In case of Modular: Modular cover plate and metal flush boxes incl in Point wiring) NOTE:- 1.The contractor must produce certificate of FRLSH wire as well as on site testing of FRLSH wire. 2.Make of The modular cover plate must be same make of switch/socket. 3.CUTTING CHASES AND REPAIRING OF SURFACE MEASURED AND PAID SEPERATELY.
All as per Sl item No 2 above herein before but one 5Amp socket point on independent board but with other switches complete all as specified and directed.
All as per Sl item No 2 above herein before but one socket out let 5 pins 5 Amp on the same board but with other switches complete all as specified and directed.
All as per Sl item No 2 above herein before but one socket out let 3 pin 15 Amp Independent with 2.5 sqmm wire including 1.5 sqmm PVC insulated and unsheathed FRLS single core stranded copper earth continuity conductor complete all as specified and directed.
M & L for point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH(FLAME RETARDANT LOW SMOKE AND HALOGEN) single core multi-stranded copper conductor for one light/fan in existing conduit to be terminated in pressed steel terminal boxes with top cover plate including 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed. (Switches and regulators shall be measured and paid for separately.) (Wiring shall be done as per colour code in IS for phase, neutral and earth) (In case of Modular: Modular cover plate and metal flush boxes incl in Point wiring). NOTE:- 1.The contractor must produce certificate of FRLSH wire as well as on site testing of FRLSH wire. 2.Make of The modular cover plate must be same of make switch/socket.
All as per Sl item No 6 above herein before but one 5Amp socket point on independent board but with other switches complete all as specified and directed.
All as per Sl item No 6 above herein before but one socket out let 5 pins 5 Amp on the same board but with other switches complete all as specified and directed.
All as per Sl item No 6 above herein before but one socket out let 3 pin 15 Amp Independent with 2.5 sqmm wire including 1.5 sqmm PVC insulated and unsheathed FRLS single core stranded copper earth continuity conductor complete all as specified and directed.
S& F Modular switch 1 way, 6 Amps, 1 module complete all as specified and directed by engg- in charge.
S & F Modular switch 1 way, 16 Amps, 1 module with indicator lamp complete all as specified and directed by engg- in charge.
S & F Modular socket 5 pin 6 Amps, 2 module complete all as specified and directed by engg- in charge. .
S & F Modular socket 5 pin 6/16 Amps, combination type 2 module complete all as specified and directed by engg- in charge.
S& F Modular Bell switch 1 way, 6 Amps, 1 module complete all as specified and directed.
Suppy and fix bell ding dong type AC 230 volts complete all as specified and directed.
S & F fan regulator modular type 2 module 6 step complete all as specified and directed by engg- in charge.
S&F ceiling rose surface bakelite surface 65 x 50mm 3 terminals all as specified & directed.
Supply and fix bulb batten holder including flexible wire complete all as specified and directed.
S&F incl taking down 12 watt LED Bulb with base cap B22/E27 type minimum 90 lumen/watt having correleted color temperature(CCT) of Emitting light 6500 /3000 K with CRI of LED >90 complete all as specified and directed by Engr in Charge.
S&F incl taking down 20 watt wall mounted, new generation LED batten fitting 4 feet with polycarbonate diffuser andextruded thermoplastic body > 90 lumen/watt having correleted color temperature(CCT) of Emitting light 6500/3000 K with CRI of LED >90 . including all fixing accessories & connecting up with PVC insulated twin core flexible copper conductor cable of suitable size complete all as specified and directed by Engr in Charge.
Supply and fix in replacement of old unsv building light ,25 W IP 66 LED security light for building luminaire comprising of die cast aluminium housing with weather proof gasket for lamp & driver compartment with system wattage of 25 W . The LED make must be of minimum 100 lumen/watt CCT 6500K .The driver must be power factor > 0.95 with short circuit protection , open circuit protection , reverse polarity protection , high voltage protection. the luminaire must have secondary optics with perfectly matched lens for better light control with GI bracket of suitable size and clamps with fixing accessories connection with PVC insulated three core flexible copper conductor cable 0.75X3 Sqmm with proper clamps complete all as specified and directed by Engr in charge.
Supply and fix incl taking down new generation energy saving 9/10 watt LED bulk head (porch light fitting) made of plasitic housing with opal diffuser With IP 65. having correleted color temperature(CCR) of Emmiting light 6500/3000 K with CRI of LED >90. connection with PVC insulated twin core flexible copper conductor cable of suitable size.complete all as specified and directed by Engr in Charge.
S&F MCCB DB VTPN 4 WAYdouble door 240 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for ways with IP65 protection complete all as specefied and directed. (Note: MCCB should be B or C curve as directed by engineer in charge)
S&F MCCB , TPN, 240 Volt , 125 amp for fixing in DBs of including proper thimble connections complete all as specified and directed. (Note: MCCB should be B or C curve as directed by engineer in charge)
S&F MCB DB double door 240 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for 8 ways with IP42 protection complete all as specefied and directed. (Note: MCB should be B or C curve as directed by engineer in charge)
S&F MCB , SPN, 240 Volt , 40 amp for fixing in DBs of including proper thimble connections complete all as specified and directed. (Note: MCB should be B or C curve as directed by engineer in charge).
S&F MCB, single pole 240 volts 6 to 32 Amp capacity fixing in DB’s including proper thimble connections complete all as specified and directed. (Note: MCB should be B or C curve as directed by engineer in charge)
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 6 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 4 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as directed. Note1: Casing and cementing work measured and paid seperately. Note2 : Two runs of 6 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length). NOTE:-1.The contractor must produce certificate of FRLSH wire as well as on site testing of FRLSH wire.
Earthing complete with galvanised steel earth plate electrode, 600x600 x 6.0mm thick buried directly in ground(earth pit not less than 2.25m deep below normal level) connected to galvanised earth lead wire 4.0mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No 3 of SSR Part I. Connected to earthing test point testing complete including necessary earth pit chamber PCC 1: 3: 6 type C1, and 50mm thick RCC 1 : 2: 4 chamber cover and with 8mm dia mild steel re-enforcement of 15Cm C/C spacing both ways with a handle made of 8 mm bar for fitting, galvanised iron funnel, wire mash watering pipe GI 20 mm dia light grade, and protection to earth lead shall be provided with GI pipe light grade 15mm dia up to 7.5m from the earth plate electrode, excavation, charcoal and common salt mixed refilling of soil etc complete all as directed.
M&L switch piano flush type single pole, one way 6amp complete all as specified and directed.
M&L switch piano flush type two way 5/15 amp complete all as specified and directed.
M&L switch piano flush type single pole, one way 15 amp complete all as specified and directed.
M&L socket outlet piano flush type 2 in 1 3 pin 5 amp complete all as specified and directed.
M&L socket outlet piano flush type 3 pin 15 amp complete all as specified and directed.
S/fix fan regulator electronic socket type complete all as specified and directed.
M&L switch flush type bell push button 6 amp complete all as specified and directed.
S&F modular white/grey cover plate with frame, 1 module/2 module complete all as specified and directed.
S&F modular white/grey cover plate with frame, 3/4module complete all as specified and directed.
S&F modular white/grey cover plate with frame, 6 module complete all as specified and directed.
S&F modular white/grey cover plate with frame, 8 module complete all as specified and directed.
S&F Metal Flush boxes 1/2 module complete all as specified and directed.
S&F Metal Flush boxes 3/4 module complete all as specified and directed.
S&F Metal Flush boxes 6 module complete all as specified and directed.
S&F Metal Flush boxes 8 module complete all as specified and directed.
M&L modular switch 1 way 6 A, 1 module complete all as specified and directed. Make :(as per existing fitment)
M&L modular bell push switch, 6 A, 1 module complete all as specified and directed. Make :(as per existing fitment)
M&L modular socket, 6A-2/3 pin combined, 2 module complete all as specified and directed. Make :(as per existing fitment)
M&L modular switch 16 Amps, 1 module with indicator complete all as specified and directed.Make :(as per existing fitment)
M&L modular socket 16 Amps, 6 pin, 2 module complete all as specified and directed. Make :(as per existing fitment)
S&F modular fan step regulator, 120W - 1 module 6 steps complete all as specified and directed. Make :(as per existing fitment)
S&F bell Ding dong AC 230Volts single pole complete all as specified and directed.
M&L for cutting chases for concealed conduit wiring, pinning in making good to facings where required and pointig in cement mortar1:3 to ends or edges of landings, and making good, cutting not exc 10 cm girth.all as specified and directed by engg- in charge
S/Fix in replacement of old MCB DB TPN 4 Way with 200Amp standerd bus bar factory made IP 65 protection class metal double door with Shrouded Neutral Bar & Pan assembly with connecting link complete including Provision for fixing one MCB TPN upto 125A complete all as specified and directed. (MCB TPN will be measured and paid separately under respective items of sch A):-
S&F MCB TPN 240 volts 63 to 100 Amp capacity fixing in DB’s including proper thimble connections complete all as specified and directed. (Note: TPN should be B or C curve as directed by engineer in charge)
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 10 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 6 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as directed. Note1: Two runs of 10 sqmm cable alongwith one run of 6 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length 2.Chasin and cementing work measured and paid seperately.) NOTE:-1.The contractor must produce certificate of FRLSH wire as well as on site testing of FRLSH wire.
Supply and fixing for sub main wiring Four single core PVC insulated and unsheathed cable with 10 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 6 Sqmm 2 core PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as directed. Note1:Chasin and cementing work measured and paid seperatelyNote2 : four runs of 10 sqmm cable alongwith two run of 6 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length). NOTE:-1.The contractor must produce certificate of FRLSH wire as well as on site testing of FRLSH wire.
supply and fixing exhaust fan 300 mm metalic body with LOUVER iron shutter of suitable size,single phase ac 220Vcompelete all as specified and as directed.
S&F incl taking down 20 watt wall mounted, new generation alluminium BATTEN SUITABLE FOR LED T-8 Retro fit for multipuspose application with 20 Watt LED Rod 4 feet > 90 lumen/watt , made from extruded aluminium housing,polycarbonate diffuser having correleted color temperature(CCT) of Emitting light 6500/3000 with CRI of LED >90. including all fixing accessories & connecting up with PVC insulated twin core flexible copper conductor cable of suitable size complete all as specified and directed by Engr in Charge.
S&F incl taking down 18 Watt LED tube Rod 4 feet T-8 Retro fit >90 lumen/watt made from polycarbonate diffuser and polycarboneted body having correleted color temperature(CCT) of Emitting light 6500/3000 K with CRI of LED >90. complete all as specified and directed by Engr in Charge.
Supply and fix incl taking down Led Stellar Square/round SURFACE Mounted Asthetically designed energy saving LED LIGHT for indoor application of capacity 10 watt having correleted color temperature(CCR) of Emitting light 6500 OR 3000 K(According to requirement) with CRI of LED >90.complete with all electrical connection with PVC insulated twin core flexible copper conductor cable 0.75X2 Sqmm with proper clamps.complete all as specified and directed by Engr in charge.
Supply and fix incl taking down antique look decoretive surface mounted classic living room wall light with base cap B22/E27 body made with METAL and glossy GLASS having fitting capacity upto 20 watt. connection with twin core twisted flexible copper conductor cable .75X2 Sqmm with proper clamps complete all as specified and directed by Engr in Charge. NOTE:-bulb is not included in quoted rates measured and paid seperately.
Supply and fix incl taking down outdoor decorative LED Post top lantern with spun aluminium die cast Housing cum heat sink PMMA diffuser in IP66 with base cap B22/E27 fitted LED bulb of 20watt. complete all as specified and directed by Engr in Charge.
Supply only LED active power factor correction (APFC) electronic gear (electronic driver) suitable for 25 watt LED light fitting O/P current upto .6A output voltage 23-36V power factor >.90 complete all as directed by Engr-in-Charge.
S&F PVC insulated copper conductor 3 core 1.5sqmm passing through flexible PVC conduit and fixed with clamp. complete all as specified and directed. NOTE:-cable and flexible conduit both included in quoted rates.
S&F Alluminium conductor service cable 2 core 6 sqmm with PVC insulated.fixed with clamps complete all as specified and directed.
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 4 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 4 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as directed. Note1: Chasin and cementing work measured and paid seperately. Note2 : Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length). NOTE:-1.The contractor must produce certificate of FRLSH wire as well as on site testing of FRLSH wire.
M&L for sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through exising surface/recessed steel/PVC conduit incl 4.0 Sqmm PVC insulated unsheathed FR stranded copper conductor cable as earth wire all as specified and directed. NOTE:-1.The contractor must produce certificate of FRLSH wire as well as on site testing of FRLSH wire.
M&L for sub main wiring with two single core 4.0 Sqmm PVC insulated and unsheathed FRLSH ,stranded copper conductor cable drawn through exising surface/recessed steel/PVC conduit incl 4 Sqmm PVC insulated unsheathed FR stranded copper conductor cable as earth wire all as specified and directed. NOTE:-1.The contractor must produce certificate of FRLSH wire as well as on site testing of FRLSH wire.
Supply and fix earth metal plug Box capacity 20 amp complete all as specified and directed.
Arun enterprises
gurchan singh & sons.
AGGARWAL & CO
RUPINDER SINGH SODHI
UNITED ENGINEERING CORPORATION
Arneja Builders
u and v engineers and consultants
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .