GARRISON ENGINEER NAVY LAKSHADWEEP
Military Engineer Services GE Navy lakshadweep Coast Guard Road Kavaratti Islands
MAINTENANCE AND REPAIRS TO INTERNAL WIRING FITTINGS AND FIXTURES REWINDING OF CEILING FAN, EXHAUST FAN, SOLAR WATER HEATER, ELECTRIC GEYSERS AND COOLING APPLIANCES AT MINICOY ISLAND UNDER GE NAVY LAKSHADWEEP.
2023_MES_620733_1
8373/E8
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
GARRISON ENGINEER NAVY LAKSHADWEEP
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER NAVY LAKSHADWEEP
₹34,000
Yes
21 Dec 2023
27 Sept 2023
28 Oct 2023
27 Sept 2023
25 Oct 2023
11 Oct 2023
27 Sept 2023 - 4 Oct 2023
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed by Engineer-in-charge.
M & L for Point wiring with PVC insulated unsheathed and multistranded copper conductor cable ISI marked, 1100 volt grade FRLS of size 1.5 Sqmm drawn in existing concealed PVC rigid conduite and fixing modular white plate with frame of suitable size as required at site with PVC insulated unsheathed stranded copper conductor of size 1.5 Sqmm as earth wire connected common earth dolly as specified for one light point controlled by one switch for light/Fan complete all as specified and directed by Engineer-in-charge. Note: (i) Rate quoted should include cost of modular metal flux box concealed and making good walls (ii) Rate include the modular white cover plate with frame. (iii) Necessary blank plate as required at site.
All as per item No 02 here in before but one 3 pin 5 amps switch sockets on same board complete all as specified and directed by Engineer-in-charge.
All as per item No 02 here in before but one 3 pin 5 amps switch sockets on independent board complete all as specified and directed by Engineer-in-charge.
All as per item No 02 here in before but with cable size 4 Sqmm and 2.5 Sqmm as earthwire for 3/5 pin socket outlet independent, 15/16 Amps complete all as specified and directed by Engineer-in-charge.
S & F modular switch, 1 way, 6A, 1 module complete all as specified and directed by Engineer-in-charge.
S&F modular socket, 6A, 2/3 pin combined 2 module complete all as specified and directed by Engineer-in-charge.
S & F modular switch, 1 way, 16A, 1 module complete all as specified and directed by Engineer-in-charge.
S&F modular socket, 6/16A, 2/3 pin combined 2 module complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement switch piano flush type single pole one way 5 amps 230 volts ISI marked complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in replacement switch socket combination flush type universal 2 in 1, 3 pin 5 Amps 230 volts ISI marked complete all as specified and directed by Engineer-in-charge.
All as per Item No 11 here in above but of capacity 15 Amps complete all as specified and directed by Engineer-in-charge.
S&F in repairs ceiling rose 3 terminal 5 Amps 230 volts ISI marked, PVC/Polycarbonate, insulated body complete all as specified and directed by Engineer-in-charge.
S & F in replacement Fan step Regulator, 120 Watt, 2 module, hum free complete all as specified and directed by Engineer-in-charge
S&F in replacement Modular Bell push, 6 A, 1 module complete all as specified and directed by Engineer-in-charge
S & F in replacement Bell electric ding dong AC 230 V single pole complete all as specified and directed.
Supply and fixing in repairs LED lights batten fitting 1x 20W, 220V, 4 feet, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete complete all as specified and directed by Engr-in-charge.
Supply and fixing in repairs LED light batten fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete complete all as specified and directed by Engr-in-charge.
S & F in repairs LED bulb 10w retrofit type to fit in lamp holder/bulk head fittings complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repairs LED luminaire 600 mm x 600 mm, 42 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repairs round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer-in-charge.
Supply and fix in repair street light brackets made out of 40mm bore GI tubing, light grade, 1.5m long, bent to required shape, including necessary bending, welding, etc fixed with 2Nos. clamps made out of 32x5mm GI strip including necessary drilling holes, screws, nuts, bolts, etc complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair LED bldg security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed by Engineer-in-Charge.
S & F in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp, 240 V MCB complete all as specified and directed by Engineer-in-charge.
Supply only 1.5 Sqmm Flame Retardant Low Smoke & Halogen (FR-LSH) single core FR-LSH PVC Insulated Industrial Grade Copper Conductor (Unsheathed) Flexible Cable, 1100 Volt Conforming to IS 694 complete all as specified and directed by Engineer-in-charge.
All as per Item No 25 here in above but 2.5 Sqmm complete all as specified and directed by Engineer-in-charge.
All as per Item No 25 here in above but 4 Sqmm complete all as specified and directed by Engineer-in-charge.
S& F in repair MCB SP, 6 amps to 32 amps, 240 volts,10 KA complete all as specified and as directed by Engineer-in-Charge.
S& F in repair MCB SPN 16 amps to 32 amps, 240 volts,10 KA complete all as specified and as directed by Engineer-in-Charge.
S&F in repair MCB TPN/FP 16 Amp to 32 Amp 415 V, 50 Hz, complete all as specified and directed by Engineer-in-charge
S&F in repair MCB TPN/FP 40 Amp to 60 Amp 415 V, 50 Hz, complete all as specified and directed by Engineer-in-charge
S&F in repair single door MCB DB TPN 4 Way 415 V , 50 Hz, complete all as specified and directed by Engineer-in-charge
S&F in repair single door MCB DB SPN 4 Way 240 V , 50 Hz with 200A rated copper busbar complete all as specified and directed by Engineer-in-charge.
S&F in repair single door MCB DB SPN 8 Way 240 V , 50 Hz, with 200A rated copper busbar complete all as specified and directed by Engineer-in-charge.
S & F in repair Distribution board VTPN 4 way Vertical type double door 415 Volts as per IP-43 with provision for MCCB upto 160 Amps as incomer and SP/SPN/TPN MCB as outgoing and electrically connected up complete all as specified and as directed by Engineer-in-Charge.
Taking down existing unserviciable ceiling fan /exhaust fan of any type and rewinding the same with fine enamelled copper conductor and refixing at same location and testing complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair of condenser of 2.5 MFD complete all as specified and directed by Engineer-in-charge
Supply and fixing in repair of condenser of 1.5 MFD complete all as specified and directed by Engineer-in-charge
Supply and fixing in repair of unserviceable ball bearing of suitable existing size for ceiling fan 1200mm sweep complete all as specified and directed by Engineer-in-charge
Supply and fixing in repair of unserviceable ball bearing of suitable existing size for exhaust fan 300 mm sweep complete all as specified and directed by Engineer-in-charge
Taking down the unserviceable Electric geyser 25 Ltrs capacity and transporting to work shop for repairs/replacement of unserverviceable items such as heating coil, thermostat, copper container, indicating lamp to match the existing geyser complete all as specified and directed by Engineer-in-charge. Note: Cost for unserviceable items will be measured and paid under respective items as Supply only.
Supply only Heating coil suitable for Electric geyser 25 Ltrs complete all as specified and directed by Engineer-in-charge.
Supply only thermostat suitable for Electric geyser 25 Ltrs complete all as specified and directed by Engineer-in-charge.
Supply only inner container made of copper suitable for Electric geyser 25 Ltrs complete all as specified and directed by Engineer-in-charge.
COOLING APLIANCES Maintenance and servicing of split type 1.5/2 Ton AC including cleaning filter, washing with soap solution after removing from site and refixing complete all as specified and as directed by Engineer-in- Charge.
Supply and fixing in repair of hermitically sealed outdoor compressor unit including brazing/welding and leakage testing after completon of job for 1.5 Ton Split type AC complete all as specified and as directed by Engineer-in- Charge.
All as per item no. 46 here in above but for 2.0 Ton capacity complete all as specified and as directed by Engineer-in- Charge.
Material and labour for gas charging including comissioning and testing in split AC 1.5 Ton complete all as specified and as directed by Engineer-in- Charge.
Material and labour for gas charging including comissioning and testing in split AC 2 Ton complete all as specified and as directed by Engineer-in- Charge.
Supply and fixing in repair of condensing coil copper including soldering with existing system for 1.5 Ton AC complete all as specified and as directed by Engineer-in- Charge.
All as per item No. 50 here in above but of capacity 2.0 Ton capacity complete all as specified and as directed by Engineer-in- Charge.
Supply and fixing in repair of outdoor fan motor for 1.5 ton AC complete all as specified and as directed by Engineer-in- Charge.
Supply and fixing in repair of outdoor fan motor for 2.0 ton AC all as specified and as directed by Engineer-in- Charge.
Supply and fixing in repair of Running Capacitor of capacity 36 MFD + 5% complete all as specified and as directed by Engineer-in- Charge.
Supply and fixing in repair of Running Capacitor of capacity 60 MFD + 5% complete all as specified and as directed by Engineer-in- Charge.
Supply and fixing in repair of Running Capacitor of capacity 2.5 MFD + 5% complete all as specified and as directed by Engineer-in- Charge.
Disconnection and removing the unserviceable PCB from the indoor unit of Split type Air conditioner and S & F New PCB suitable for the existing Makes of Air conditioners of capacity 1.5/2 TR complete all as specified and directed by Engineer-in-charge
Disconnection and removing the unserviceable PCB from the outdoor unit of invertor type Split type Air conditioner and S & F new PCB suitable for the existing Makes of Air conditioners of capacity 1.5/2 TR complete all as specified and directed by Engineer-in-charge
Disconnection and removing the unserviceable indoor blower motor from the indoor unit of 1.5 TR Split type Air conditioner and S & F new indoor blower motor suitable for the existing Makes of 1.5 TR split type Air conditioners complete all as specified and directed by Engineer-in-charge.
Disconnection and removing the unserviceable indoor blower motor from the indoor unit of 2 TR Split type Air conditioner and S & F new indoor blower motor suitable for the existing Makes of 2 TR split type Air conditioners complete all as specified and directed by Engineer-in-charge
Disconnection and removing the unserviceable indoor swing motor from the indoor unit of 1.5 TR Split type Air conditioner and S & F new indoor swing motor suitable for the existing Makes of 1.5 TR split type Air conditioners complete all as specified and directed by Engineer-in-charge
Disconnection and removing the unserviceable indoor swing motor from the indoor unit of 2 TR Split type Air conditioner and S & F new indoor swing motor suitable for the existing Makes of 2 TR split type Air conditioners complete all as specified and directed by Engineer-in-charge
S & F in repair of copper pipe of size 1/2" dia with necessary fixing arrangements for such as welding, brazing, nut, bolts and testing complete all as specified and directed by Engineer-in-charge
S & F in repair of copper pipe of size 1/4" dia with necessary fixing arrangements for such as welding, brazing, nut, bolts and testing complete all as specified and directed by Engineer-in-charge
S&F in repair suitable stand (bracket) for outdoor unit of 1.5/2 ton split air conditioner complete all as specified and directed by Engineer-in-charge
Material and labour for gas charging with R134A including comissioning and testing complete of 40/80 Ltrs capacity water cooler all as specified and as directed by Engineer-in- Charge.
Material and labour in replacement of compressor unit for 40/80 Ltrs capacity of water cooler including comissioning and testing complete all as specified and as directed by Engineer-in- Charge.
Supply and fixing in repair of thermostat for water cooler of existing capacity and make all as specified and as directed by Engineer-in- Charge.
Supply and fixing in repair of capacitor of 10 MFD for water cooler complete all as specified and as directed by Engineer-in- Charge.
Disconnection and removing the unserviceable voltage stabilizer and replace the unserviceable items such as PCB/control board etc and refixing back in its original position testing complete as per existing Makes of capacity 2/4 KVA complete all as specified and directed by Engineer-in-charge Note: Cost for unserviceable items will be measured and paid under respective items as Supply only
Supply only PCB/control board suitable for 2.0 KVA Votlage stabilizer complete all as specified and directed by Engineer-in-charge.
Supply only PCB/control board suitable for 4.0 KVA Votlage stabilizer complete all as specified and directed by Engineer-in-charge.
General Engineering and Constructions
STANDARD ENGINEERING
KRA Engineering and Construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .