| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹26.4 L+₹2.2 L (9.24%)Rejected-Finance | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹27.7 L+₹3.5 L (14.5%)Rejected-Finance | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹29.6 L+₹5.5 L (22.6%)Rejected-Finance | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹30.0 L+₹5.8 L (24.0%)Rejected-Finance 21 PASCHIM VIHAR EXTENSION NEW DELHI 110 063 | NEW DELHI | WEST DELHI | DELHI | 110063 | L5 | Rejected-Finance Being not lowest |
| Sl No | Description | Qty | Unit | Sameer Auto Engineers L4 | M/S UnitedConstruction L2 | AGARWAL BUILDERS L3 | M/s R. K. Bhambri L5 | MODI CORPORATION L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in soft/loose soil including forming sides and bottom surface to required levels / slops / gradients and getting out complete all as specified and directed. | 180 | Cum | 120 ₹21,600 | 120 ₹21,600 | 100 ₹18,000 Lowest | 150 ₹27,000 | 250 ₹45,000 |
| 2.00 | Returning, filling in trenches including spreading leveling, watering well, ramming in layers n.exc 25 cm in soft / loose soil complete all as specified and directed. | 130 | Cum | 40 ₹5,200 Lowest | 90 ₹11,700 | 50 ₹6,500 | 40 ₹5,200 Lowest | 100 ₹13,000 |
| 3.00 | Removing excavated material to a distance n exc 50 m and depositing at a leve n exc 1.5 m above starting point complete all as specified and directed. | 50 | Cum | 150 ₹7,500 | 150 ₹7,500 | 30 ₹1,500 Lowest | 40 ₹2,000 | 50 ₹2,500 |
| 4.00S&F in repairs tubes medium grade galvanised with required all new fitting ISI marked fixed on wall/floor with fixing arrangement of following sizes:- | ||||||||
| 4.01 | 15 mm bore | 18 | RM | 100 ₹1,800 Lowest | 120 ₹2,160 | 180 ₹3,240 | 220 ₹3,960 | 130 ₹2,340 |
| 4.02 | 20 mm bore | 60 | RM | 150 ₹9,000 | 140 ₹8,400 Lowest | 290 ₹17,400 | 280 ₹16,800 | 160 ₹9,600 |
| 4.03 | 25 mm bore | 54 | RM | 180 ₹9,720 | 160 ₹8,640 Lowest | 360 ₹19,440 | 400 ₹21,600 | 170 ₹9,180 |
| 4.04 | 40 mm bore | 48 | RM | 390 ₹18,720 | 350 ₹16,800 Lowest | 430 ₹20,640 | 500 ₹24,000 | 350 ₹16,800 Lowest |
| 4.05 | 50 mm bore | 60 | RM | 420 ₹25,200 | 350 ₹21,000 Lowest | 630 ₹37,800 | 700 ₹42,000 | 400 ₹24,000 |
| 4.06 | 80 mm bore | 54 | RM | 630 ₹34,020 | 560 ₹30,240 Lowest | 940 ₹50,760 | 1,037 ₹55,998 | 600 ₹32,400 |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
21 Oct 2025, 6:00 pmClosed
GE AWC MHOW
GE AWC MHOW
REPAIR AND MAINT OF EXTERNAL WATER SUPPLY, INSTALLED INCLUDING PUMPS, MOTORS, BOREWELLS, GI PIPES LINES, CLEANING OF UG SUMP AND OTHER CONNECTED ITEMS AND COMPREHENSIVE MAINT OF 200 KLD STPS AT GOSWAMI ENCLAVE SARNA ENCLAVE UNDER GE (AWC) MHOW.
2025_MES_732102_1
8865/(AWC) /MHOW / OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AWC MHOW
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AWC MHOW
₹66,000
10 Dec 2025
22 Sept 2025
23 Oct 2025
22 Sept 2025
21 Oct 2025
7 Oct 2025
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep in soft/loose soil including forming sides and bottom surface to required levels / slops / gradients and getting out complete all as specified and directed.
Returning, filling in trenches including spreading leveling, watering well, ramming in layers n.exc 25 cm in soft / loose soil complete all as specified and directed.
Removing excavated material to a distance n exc 50 m and depositing at a leve n exc 1.5 m above starting point complete all as specified and directed.
S&F in repairs tubes medium grade galvanised with required all new fitting ISI marked fixed on wall/floor with fixing arrangement of following sizes:-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
Renewal of gun metal globe or gate valve ISI marked with iron wheel head screwed both ends for iron pipes of following sizes:-
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
Supply and fixing in replacement of cast iron sluice valve class PN-1.0 ISI marked, both ends flanged, stainless steel spindle, with iron wheel and necessary jointing materials, nuts & bolts, washers etc for making two flanged joints of following sizes as required.
80 mm bore
100 mm bore
Supply and fixing CI foot valve 100 mm size including lifting of pipes from sump and replacement of rusted flanges, nuts etc and refixing the same complete all as directed.
Construction of brick masonry valve pit chamber with 3 mm thick MS sheet cover and 40 x 40 x 6 mm angle iron frame embedded in PCC coping 1:3:6 type C-1 using 20 mm graded stone aggregates with locking arrangements of size 1200 mm x 1200 mm x1200 mm (internal size), depth 500 mm, brick work in cement mortar 1:4 using sub class ‘B’ (old size) bricks, internal walls plastered with 15 mm thick cement mortar 1:4 and finishing the surface even and smooth using extra cement, 40 mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate in coping, PCC 1:4:8 type D-2 using 40 mm graded stone aggregates in foundation 75 mm thick with and including necessary excavation & earth work in soft / loose soil Complete all as specified and directed.
Disconnecting and lifting the existing non functional submersible pump sets with dismantling existing bend from non return valve, removing and lifting out submersible pump sets of any description and capacity and in any position alongwith existing column pipe 80mm dia and submesible cable of any size from borewell 150/200mm (approx 30mtr ).
Lowering down the serviceable submersible pump sets of any description and in any position and in any capacity in borewell alongwith the column pipe 80mm dia and submersible cable of any size complete all as directed and making necessary electric connection and testing complete after lowering.
Dismantling and strip opening of submersible pump and motor of any description and in any position, transporting to workshop for servicing, overhauling, cleaning,greasing,removing and reassembling the pump and motor with proper alignment of both pump and motor, fixing in position connecting to existing system and testing at site on full load to the entire satisfaction of the Engr-in-charge for the pumps 20/25 HP, 3 phase, 415volts,50Hz AC Supply complete all as specified and directed. Note :(I) The replacement of defective non functional parts shall be measured and paid for separately under respective item of sch A. (ii) The rate of above item shall be deemed to include transportation to and from of pump, motor to workshop as approved by Engr-in-charge for necessary repair, alignment and testing of pump and motor at workshop.
Supply only following parts of submersible motor of any description of capacity 10/15HP or 1/5 HP all as specified and as directed by Engr-in-charge.
Gun metal bush
Rubber bush
Brass thrust plate
CI thrust bearing
CI thrust casing
Water seal
CI lower/upper housing of shaft
Rotor sleeve
Supply and fix in replacement the following parts of submersible pump of any description 10/15 HP or 1/5 HP capacity complete all as specified and as directed.
Coupling set with key of stainless steel
Discharge outlet CI
Stage casing CI
Gun metal sand guard
Gun metal neck ring
Gun metal impeller
M&L for repair to impeller of submersible pump of any description by breazing, welding, metalling, turning and polishing of capacity 10/15 HP all as specified and as directed.
M&L for rewinding of submersible motor 10/15 HP with PVC insulated copper winding wire of existing size and approved make after taking down burnt winding, cleaning of slots with CTC solution, transportation at site, fixing in position and testing complete all as specified and as directed.
M&L for rewinding of submersible motor 1/5 HP with PVC insulated copper winding wire of existing size and approved make after taking down burnt winding, cleaning of slots with CTC solution, transportation at site, fixing in position and testing complete all as specified and as directed.
M&L for GI Bend suitable for 80 mm bore column pipe heavy duty flanged and drilling at both the ends with having arrangement of mounting pressure gauge complete all as specified & as directed.
M&L for column pipe 80 mm bore heavy duty ISI marked confirming to IS-1239 for column pipe 3 mtr length, both end flanged.
Dismantling and removing existing non functional 10HP centrifugal pumpsets of any description, dismantling and strip opening, overhauling , cleaning, greasing and replacement of unserviceable/worn out spare parts and reassembling, re installation at site and testing complete all as specified and as directed. Note :-Replacement of U/S parts will be measured and paid separately under respective item of sch A
M&L for rewinding of centrifugal motor of any make and capacity 10 HP with super enamelled copper conductor of existing size of approved make after dismantling from foundation, cleaning slots with CTC solution including transportation to workshop and return to site after repair, refixing in position and testing on full load complete all as specified and as directed.
Supply only following spare parts of 10 HP centrifugal pump.
CI gland plate set
Ball bearing for pump/ motor 10 HP
CI coupling set flanged type with rubber insertition and suitable bolts complete all as specified.
MS stud with nuts & bolts size 3/8"X2"
Turning and polishing of pump shaft
CI Impeller
Supply and fixing in replacement of following parts of booster motor capacity 10/15 HP.
PVC fan including tapping for fixing of fan
MS terminal box with insulated plate and studs
Cleaning of underground sump, removing sludge / dirt / sand by means of manual wash out, outlet cleaning from inside with bleached water and washing with sodium hydrochloride liquid, drying and applying one coat of lime wash internally and spraying anti bacteria liquid, writing date of cleaning on outer wall of sump with white paint on black base for 25000 litre to 40000 ltr capacity complete.
Cleaning of Over Head Tamk (OHT) approximately 20 mtr staging, upto 75000 Ltr to 100000 Ltr capacity, removing sludge / dirt / sand by means of manual wash out, outlet cleaning the overhead reservoir from inside with bleached water and washing with sodium hydrochloride liquid, spraying anti bacteria liquid, writing date of cleaning on outer wall of overhead reservoir with white paint on black base complete.
Testing of collected water sample from NABL lab from AWC in period of one quarter from all necessary perameters which are directed by Engr -In - Charge complete as specified and directed.
Dismantling the submersible pump/ monoblock pump of 03 to 05 HP capacity, cleaning, repairing, overhauling ,winding and replacement of all unserviceable parts, nut, bolts, impellars, bushes, thrust bearing, clutch system, bowl assembly and repairing/replacement of pump shaft and re-assembling, commissioning and testing to make it operational / functional, complete all as specified and as directed. Note :- All transportation /winding included in quoted rates .
M & L for repair of any type unserviceable starter suitable for 5 HP to 15 HP motor complete all as specified and directed .
M&L for cleaning the area including uprooting of weeds/grass and removing creepers from fencing or pole/posts and brooming the complete area of substation around panels, borewells and sumps specified and directed.
M&L for spraying chemical (Glycel / Roundup and chemical composition Isopropyl amine salt of glyphoeate a.i.-40.60%, surfactant inert polyoxy ethylene amine 15.00 % & manufacturing Impurities 4.00% ) on area to remove unwanted vegetation / grass at various locations as directed by Engr-in-Charge. Notes - 1. Labour and equipments to spray chemical on required area shall be deemed to be inclusive in quoted rates of contractor. 2. Spray will be repeated quarterly or as per the directions of Engr-in-Charge.
M & L for repair of any type unserviceable starter suitable for 3 HP to 5 HP motor complete all as specified and directed .
M&L for painting to old chain link / MS XPM fencing and steel sections post with two coats aluminium paint over a coat of aluminium red-oxide including preparation of old steel or iron surfaces complete all as specified and directed.
Material and machine pressed precast concrete interlocking pavar block any shape and size conforming to IS 15658-2006 of 60 mm thickness M-35 grade complete all as specified and directed .
Surface excavation n. exc .30 cm deep and averaging 15 cm deep and getting out in old filling of stone aggregate and screening /segregating inc spreading material complete for borewell subsations or for making path way .
M & L for continous brick edging with width equal to the length of the bricklaid dry on edge vertically with old size of sub class B bricks all as specified and directed .
M & L for PCC 1:4:8 type D2 ( using 40 mm graded aggregate ) as in sub base of path all as specified and directed .
M&L PVC Insulated unsheathed 6 sqmm 3 core & PVC round sheathed Multicore bright eletrolytic annealed copper conductor flexible industrial power cables for working voltage upto and including 1100 Volts, complete all as specified and as directed.
M&L PVC Insulated unsheathed 10 sqmm 3 core & PVC round sheathed Multicore bright eletrolytic annealed copper conductor flexible industrial power cables for working voltage upto and including 1100 Volts, complete all as specified and as directed.
XLPE insulated ,armoured heavy duty electric cable with aluminium conductor , 1100 mm volts , grade cross sectional area 16 sqmm 4 core
XLPE insulated ,armoured heavy duty electric cable with aluminium conductor , 1100 mm volts , grade cross sectional area 25 sqmm 3.5 core
Material and labour for narmada river sand, unwashed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete all as specified and directed. Note:- Punned thickness shall be measured and paid.
Supply and laying unreinforced precast concrete cable cover, class LV, type 1 with flat, size 250 mm x 150 mm x 40 mm, complete all as specified and as directed.
S & F in repair /replacement of pressure booster pump centrifugal water pump 1 HP pump set suitable for 220 V , single phase system complete all as specified and directed .
S & F in repair /replacement of pressure booster pump centrifugal water pump 0.5 HP pump set suitable for 220 V , single phase system complete all as specified and directed .
S & F water supply system layout plan made of acrylic sheet of 2mm thick with interior lighting arrangement in cubical enclosure of size 2mtr X 1.5 mtr including hanging on wall and connecting to existing socket . Note :- Rough layout plan shall be printed and get approved from GE /AGE E/M for final printing on Acrylic sheet.
Material and labour earthing complete with gallvanised steel earth plate electrode 60x60x0.63 cm thick burried direct in ground earth pit not less than 2.25 mtrs deep below normal ground level with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised iron strip 32 mm x 6 mm earthing lead by means of bolts, nuts, washers and check nuts of galvanised iron or steel all as shown in electrical plate No. 3 of SSR part 1 connected to earthing test point with 40mm dia light grade protection pipe upto 7.5 mtr long including necessary excavation earth work PCC earthing pit cover, watering pipe wire mesh funnes etc as directed.
Repair and overhauling incl Dismantling/taking down all electrical and mechanical connection of twin lobe blowers model No (Make:- Everest) capacity ,pressure 0.37 kg/cm and servicing hole body, change gear oil/lubricant and V belt,overhauling of the same including refixing and testing complete all as specified and directed. Note:- spare parts and gera oil/lubricant shall be measured and paid including supply of following materials: (a) Servo gear oil super 90, Make indian oil (b) Bearing as per sample for air blowers model No -610FS (c) Gasket kit as per sample for air blowers model No -610FS (d) Oil sealas per sample for air blowers model No -610FS (e) V-belt as per sample for air blowers model No -610FS (f) Air filteras per sample for air blowers model No -610FS
Taking down Turbine motor of 7.5 HP/ 5 HP capacity from existing position for carring out repair works and re-assembling ,re-installing the pump set in original position for the following capacity. Note:- Spare parts ,winding wire required for renewal will be paid seperately
Pumping out sewage water from sludge drying beds and disposing the same as directed and a distance exc 50 mtr and nexc 100 mtr (volum of watew to be measured and paid) incl Hiring of pump set of required capacity complete all as specified and as directed for 250 KLD plant .
Dewatering the equalisation tank capacity 40000 Ltrs (Approx) with the help of mud pump and removal of complete sludge and cleaning inside, descaling with wire brush internal surface of tank and scraper unit floculator and washing fresh water two times with bleaching powder all as specified & directed by Engr-in-Charge. Note:- 1. Make a temporary arragement of sewage disposal by existing adhoc pump to approx 100 mtrs far from STP. 2. Work is in running condition and the contractor is required to take necessary safety precautions and arrange safety mask, hand gloves etc 3. Arragement of mud pump set for dewatering at his own expense. Quoted rate is deemed to be inclusive of the above aspect.
M& L for dewatering with help of mud pump and Manning for cleaning of MBBR tanks of compartments of each 1.6m dia and height 6m size and removing all the settled solid sludge or any other type of material and through out side MD Land and as directed by Engr-in-Charge. (250 KLD)
M & L for dewatering with help of mud pump and Manning for cleaning of tube settler tank of size 3m x 2mx 3m height (approx) and removing all the settled deposited fungus or any other type of bio-fouling and all as directed by Engr-in-Charge.
M&L for taking out carbon filter from ACF tank and replacing with fresh carbon/ anthracite chemically treated incl servicing and cleaning the filters complete all as directed Note :- Media to be paid seperately
M&L for taking out sand bed from cylinderical DMF tank and replacing the same with chemically treated filter beds viz. pebbles, sand etc chemically treated. Note :-Media to be paid seperately
M&L painting of water treatment plant mbbr tanks, tube settler tank, filter columns, pipe line and induction motor of following sizes including scraping of old paint from GI pipe and induction motor with emery paper, preparing old surface for painting, apply two coats of synthetic enamel paint in steel grey/ colour coded differently by using spray gun complete all as specified and directed :- (a) 40mm dia (b) 50mm dia (c) 80mm dia (Total length of all pipes approx 60m)
Material for replacement of quartz silica sand 32-64 grade complete all as specified and directed by Engr-in-charge.
Material for replacement of quartz silica sand 16-32 grade complete all as specified and directed by Engr-in-charge.
Material for replacement of quartz silica sand 8-16 grade complete all as specified and directed by Engr-in-charge.
Material for replacement of quartz silica sand 4-8 grade complete all as specified and directed by Engr-in-charge.
Material for replacement of activated carbon IV 1000 complete all as specified and directed by Engr-in-charge.
Material & Labour for painting to exposed Filter media tank (ACF and DMF) at water supply installations as per specified colour code after cleaning and scraping out old paint including writing/marking complete all as specified and directed.
Comprehensive Maintenance of sewage Treatment plant of capacity 200 KLD at Sarna Enclave including all consumable materials ,repairing ,replacement of any part of STP all as specified and as directed .
Comprehensive Maintenance of sewage Treatment plant of capacity 200 KLD at Goswami Enclave including all consumable materials ,repairing ,replacement of any part of STP all as specified and as directed .
Note 1 For Items 61 & 62 :- (i)Coarse and fine Bar screen chamber (ii) MBBR reactor (iii) Air blower (iv) Tube shelter (v) Sludge feed Pumps (vi) Filteration system (vii) feed pumps and raw water sewage pumps (Submersible and centrifugal) (viii) Inter connecting pipes (ix) chlorine contact tank/hypo dosing tank (x) Valves (xi) Centrifuge (xii) Electrical system/ cables/ wires and panel (xiii) Oil and grease trap (xiv) Raw water collection sump (xv) Installed machinary for treated water supply (xvi) Treated water tank installed with STP. (xvii) DG set of capacity 40 KVA
Note 2 For Item Nos 61 & 62:- The quoted rates against Items No 16&17 shall include to fulfill the undergiven parameters scope of work A.-(i) to (ix),(B-(i) to (iv) & (C-(i) to (viii)) mentioned below :- (i) Stacking the sludge cakes properly (ii) Cleaning the blockages in any pump/pipe line (iii) Supplying/distributing the treated water regularly as per the directions . (iv) Complete cleaning of grits and channels daily. (v) Brooms and cleaning materials will be arranged by the contractor (vi) During the cleaning safety equipments will be supplied/arranged by the contractor. (vii) POL will be collected from MES store yard under Sch B free for use ,by the contractor at his own arrangements.For record purposes PRRB shall be maintained. (viii) Removing the algae/ sludge in the tube settler and keeping the surrounding area clean daily and removing vegetations etc failing which recovery of Rs. 200/- per day shall be made. (ix) Mixing of the chemicals as directed . B. Maintaining the following records :- (i) Record of chemical consumption (ii) Record of treated water and electricity consumption (log sheet) (iii) Record of DG set daily running (log sheet) (iv) Record of water meter reading (v) Log sheet for records shall be supplied by the contractor after approval of format by GE/Engineer-in-charge. (vi) Chemicals will be measured and paid for separately under respective items. (vii) Diesel and engine oil for DG set shall be issued under Sch 'B' as free for Use . (viii) Contractor shall ensure that treated sewage water shall confirm to the following characteristics:- (i) TSS : < 10 mg/litre (ii) BOD : < 10 mg/litre (iii) COD : < 150 Mg/litre (iv) Ph : 6.5 - 8.5 (v) Total Coliform : < 100 MPN/100 ml (desired nil) (vi) Residual CI < 1 mg/litre C. The STP should be run 24 Hrs daily basis . The contractor should deploy are skilled experienced staff for maintenance and operation of STP for 24 Hrs .
Carrying samples for Testing of treated water of STP ,submission of detailed test report to the office of the Engineer-in-charge and testing in NABL approved laboratory as approved by GE. Details are as under :- (a) Carrying out minimum essential testing of water as per IS 10500 of 1991 mandatory for chemicals, colour, odour, PH value, TSS, BOD, COD, Total residual chlorine, total Nitrogen, Sulphate, oil and grease , Ammonical Nitrogen (NH3-N) and Bacteriological total coliform organisms per 100 ml (MPN) and E colliie in 100 ml.
Testing of Sewage water as per relevant IS of STP , submission of detailed test report to the office of the Engineer-in-charge and testing in NABL approved laboratory as approved by GE Details are as under :- (a) Carrying out minimum essential testing of sewage water as per revlevant IS mandatory for chemical, odour, PH Value, TSS, BOD,COD total nitrogen, sulphate, oil and grease ammonical Nitrogen (NH3-N) and Bacteriological total collifrom organisms and other charaterstics as per relevant IS of sewage water. Notes for Srl item No 5 & 6:- Rate quoted shall deemed to be included for :- (i) Cost of sterilised bottle as required (ii) To and fro transportation charges for collection of sample
M/S UnitedConstruction (BID ID -3460780)
AGARWAL BUILDERS (BID ID -3462666)
Sameer Auto Engineers (BID ID -3450983)
M/s R. K. Bhambri (BID ID -3463489)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.17 MB
Tdocus.pdf
Tender Documents • 0.81 MB
BOQ_819666.xls
BOQ • 0.38 MB
Listofmake.pdf
Tender Documents • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .