Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹45.3 L+₹2.5 L (5.75%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹45.9 L+₹3.1 L (7.22%)Rejected-AOC 227 2 5TH B MAIN ROAD 2ND BLOCK HRBR LAYOUT KALYAN NAGAR BANASAWADI BANGALORE 560 043 | BENGALURU URBAN | KARNATAKA | 560043 | L3 | Rejected-AOC L3 | |
| 4 | L4₹48.0 L+₹5.2 L (12.0%)Rejected-AOC NO 71 1ST CROSS MUNESWARA BLOCK PALACE GUTTAHALLI BANGALORE 560 003 | BENGALURU URBAN | KARNATAKA | 560003 | L4 | Rejected-AOC L4 | |
| 5 | L5₹48.6 L+₹5.8 L (13.6%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹35.7 L
EMD Value
₹71,400
Closing Date
10 Nov 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore - 63
ADDITION/ALTERATION TO BLDG. NO T-41 AND PROVISION OF CERTAIN MINOR WORKS AND MAJOR REVENUE WORKS AT AFS YELAHANKA
2022_MES_557449_1
8114/E8
Open Tender
Civil Works
Item Rate
180 days
AF Stataion Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹71,400
Yes
10 Mar 2023
13 Oct 2022
12 Nov 2022
13 Oct 2022
10 Nov 2022
28 Oct 2022
Amount
Excavation in trenches not exceeding 1.5 m wide & not exceeding 1.5 m in depth for foundation etc or for shaft,wells, etc and n. exc 10 Sqm on plan and n.exc 1.5M in depth & getting out in any type of Soil.
Returning filling in , including spreading , levelling, watering and well ramming in layers not exceeding 25 CM.
Removing of excavated surplus soil not exceeding 50m and depositing where as directed at a level not exceeding 1.5m above the staring point.
M&L for PCC 1:4:8 ,type D-2 using 40mm graded stone aggregate as in foundation, filling & mass concrete.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc and finished rough flat surfaces of concrete .
M&L for Formwork to chajja and finished concrete flat.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter and finished flat concrete surfaces.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.
All as per item No 9 as above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders.
M&L for RCC 1:2:4 (Nominal mix ) Type B1 using 20 mm graded stone aggregate for Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M&L for RCC 1:2:4 (nominal mix)Type B1 using 20mm graded stone aggregate in beams, cantilevers, lintel over 1.5m span all as specified
M&L for RCC 1:2:4(nominal mix)Type B1 using 20mm graded stone aggregate in Chajja all as specified
M&L for RCC 1:2:4 (Nominal mix )Type B1 using 20 mm graded stone aggregate in foundation including rafts, footings, foundation beams, plinth beams and mass concrete
M&L for precast cement concrete block masonary with solid blocks exc 10cm in width and setting in CM 1:6 block type C1, 1:3:6 (20 mm graded stone aggregate)
M&L for 15 mm thick plastering on fair faces of brick work or concrete walls surfaces in cement mortar 1:4 and finish the surface even and smooth without using extra cement.
M&L for 10mm thick cement plaster in CM 1:6 on fair faces of brick or concrete surfaces of wall and finished even and fair without using extra cement.
M&L for prepration of new plastered surfaces of wall and applying two coats of oil emulsion distemper over a coat of alkali resistant cement primer complete all as specified and directed. .
M&L for preparation of new plasterd surfaces of walls and applying two coats of cement based paint over a coat primer complete all as specified and directed.
M&L for Hardcore of broken boulders of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface.
M&L for 100mm thick PCC 1:4:8 ,type D2 using 40 mm graded stone aggregate as in sub base of floor .
M&L 40mm thick PCC 1:2:4,Type B0 using 12.5mm graded stone aggregate as in floor and finished even and smooth
M&L 75 mm thick PCC 1:3:6, Type C1 using 20mm graded stone aggregate as in plinth protection and hard standing finished the surface even and fair without using extra cement.
M&L for Mild steel work in tubular/Square/rectangular trusses and purlines including special shaped washer etc complete in weldded tubes confirming to IS 1161-1979 grade St-240 including painted one shop coat of zinc chromate primer paint.
S&F joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) Fe-410-w(Gde-E-250) all as specified.
S&F plates (Plain or chequered) channels, square cut or notched (Ordinary and counter sunk) forming holes, with out any attachment Fe-410-w(Gde-E-250) all as specified.
M&L for Mild steel screw bolt diameter of shank 11 to 15mm (machine made) with hexagonal head at one end screwed the other or screwed both ends each screw end fitted with washers and one hexagonal nut, exe 05cm not exe 10cm.
M&L for Painting of steel surface of any despcription, over 10 Cm in width or girth using two coats of synthetic enamel paint over a coat of red oxide primer duly prepared the new surface.
S&F Pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
S&F Framed work such as grills , gratings, etc., with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars ; barred iron doors; ladders; framed balusters ; walk ways ; railings; frame work of water tanks and similar work conforming to Fe-290 Gde E-165
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing & complete 15mm thick screed bed in CM 1:4 over 25mm thick PCC 1:2:4 type B0 (using 12.50mm graded crushed stone agg, all as spd & directed.
M&L for 20mm thick Granite( of any size) work in cooking platform and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade .
M&L for Screed bed or bedding layer of mortar 20 mm thick for laying floor tiles in cement mortar 1:6 finished even and rough.
M&L for glazed ceramic colour designer concept glazed ceramic tiles 450x350x7/350x250x7mm size as in walls set and jointed in neat cement slurry over and including 10mm thick backing coat in cement mortar (1:4) and pointed in coloured cement to match for work on vertical surface such as skirting dado etc complete all as specified & as directed by Engr-in-Charge.
S&F powder coated anodised aluminium frame and shutters with all fixing arrangements for doors, windows and ventilators with one or more rebates including joining cleat for fixing etc aluminium section of powder coating not less than 50 micron all as specified and directed.
S&F powder coated aluminium door/Windows/ventiliator shutters aluminium section weighing 0.55kg/m including necessary joining, fixed type, cleats, glazing clips, rubber neoprene packing, roller in each window, anodised alumnium snap beading, screw etc, complete all as specified.
M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and uides) and hanging; also fastening and fixing complete
S&F sinks made of stainless steel 1 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm® omplete all as approved by Engr-in-Charge.
S&F sink cock fancy type complete all as specified and (table mounted)with 215 mm swivel spout complete all as specified and as directed. Make - Cera F2003302)
S&F PVC(SWR) Pipes 110mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F PVC (SWR) pipes 75 mm single socketed, in any length with rubber ring joints, laid in trenches or in floors and walls.
S&F in repair 15mm dia angle valves, cast copper alloy, CP, screwed down, high pressure, with crutch, screwed both ends for iron pipe or for unions and fixed .
S&F 20 mm dia of CPVC pipes SDR 11 and plain CPVC SDR 11 fittings on walls / ceiling or laying in floors complete all as specified.
S&F floor trap 110mm dia with CP grating size 100mm fixed with white cement all as specified.
M&L for Mild steel sheet eaves gutters,1.25mm thickand 150mm dia galvanised class 32, half round with rounded edges
S&F in repairs PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall (110 mm bore) including flat iron claim for proper fixing complete all as specified & directed by Engr-in-charge.
S&F II nd class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed all as specified and directed.
S&F Continuous(piano) hinges,mild steel,bright finish of electrogalvanised 30 mm width of flap.
M&L for Prelaminated particle board,19 mm thick interior grade,prelaminated one side with decorative choice lamination & other side balancing white lamination,fixed with screws to timber frame work.
M&L for preparing new or previously untreated wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer.
Surface dressing n.exc 15 CM deep and getting out in soft loose soil .
Excavation in trenches not exceeding 1.5 m wide & 1.5 m depth for foundation etc or for shaft,wells, etc and n. exc 10 Sqm on plan and n.exc 1.5 m in depth & getting out in soft/loose Soil.
M&L for preparation of the new surfaces of walls plastered , and applying two coats of cement base paint complete all as specified and as directed.
M&L for preparing the new surfaces of wall and applying two coat of oil bond distemper over a coat of interior wall care putty all as specified and as directed
M&L for cement concrete 1:4:8, 75 mm thick, type D2 using 40 mm graded stone aggregate as sub base of floor .
M&L Cement concrete 1:2:4, 25 mm thick, type B1 using 20 mm graded stone aggregate as sub base of floor with out using extra cement
M&L for Vitrified ceramic light shade tiles of 10mm thick and area of each tiles not exceeding 0.36 Sqm for flooring over 15 mm thick screed bed in CM 1:6 all as specified and directed.
M&L for Vitrified ceramic light shade tiles of 10mm thick and area of each tiles not exceeding 0.36 Sqm as in skirting over 10 mm thick rendering in CM 1:4 dado/skirting including taking down old plaster surfaces finished all as specified and directed.
M&L for 75 mm thick cement concrete 1:2:4, type B-2 using 40 mm graded stone aggregate for plinth protection .
S&F sheet glass ordinary quality 5mm thick as in doors,window, showcase alum frame work & similar work with or without glass roller any size including neoprime gasket all as directed by Engineer-in-Charge
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width or aperture 1.40 mm all as specified and directed. Note : Rate quoted by the contractor is inclusive of rate for fixing of wire cloth in steel& wooden windows/ventilators with MS flat from 15 x 3mm and fixing of wire cloth in wooden shutters with 2nd class hard wood beading all as specified and directed .
S&F aluminium powder coated drapery rod 32mm dia fixed with suitable bracket complete.(Note: Bracket will be measured and paid separately).
S& F aluminium powder coated fancy type suitabe brackets fixed at both ends of openings fixed over 1st class hard wood rounded wooden blocks 0f 65mm dia and 20mm thick fixed to stone wall/Brick wall using screws incl necesary drilling & finished with polishing Each opening shall have two fillets at both ends.
M&L for 600x600mm false ceilling tiles (Gypsum board of decorative type) of 9 mm Thick With powder coated GI Main tee of Size 24 x 32 mm , having 0.27 mm gauge @ 1200 mm c/c. rotary stiched cross tee size of 24x27 mm, guage 27 mm and cross tee of size 24x27 mm having 0.25mm gauge @1200mm c/c and angle of size 19 x 19 mm gauge 0.35 mm fixed on perifery of wall and all the above grids are suspended at every 1200 mm c/c in both direction by 2mm thick GI wire and all as per manufacture instructions.
Excavating in post holes (or similar holes) each n exc 0.5 cum, getting out in hard and dense soil returning,filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm.
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate as in foundations filling and mass concrete.
S&F Mild Steel hollow section square/rectanglular as in roof truss, purlins, rails etc, using induction butt welded tubes confirming to IS 1161-1979 grade St-240 complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 18cm deep and getting out
S & F machine pressed rubber moulded coloured precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 MM thickness , M 35 grade with grey cement and pigment bedded and laid over and including 50 mm thick sand cushion compacted and joint filled as specified and directed
M&L PCC 1:2:4 type B1 using 20mm graded stone aggregate as in Coping including earthing,rounded /chemfered angles and throating as directed including necessary form work and finishing all exposed surfaces of concrete even and smooth without using extra cement complete all as specified and as directed.
Dismantling of Asbestos cement corrugated or semicorrugated sheets in roof coverings, all as specified and directed.
Dismantling timber scantlings unframed 40 sq. cm and over in section, in any position, all as specified and directed.
S&F Roof trusses(framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beams, tee, angle, channel or flat sections) including distance piece, cleats etc Fe 410-W (Gde - E - 250) Quality 'A'.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
Dismantling of old Ceiling boards (Fibre,pulp,insulation,etc) or insulation boards /slabs blankets,including cover fillets and frame work.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L Non skid coloured Ceramic tiles 7 to 8 mm thick and area of each tiles not exceeding 0.18 Sqm as in flooring over 15mm thick screed bed in CM 1:6 all as specified and directed.
Demolition of brick work or stone masonry built in CM incl all quions all as specified
Taking down cement plaster from walls of any description all as specified and directed.
M&L for brick work with sub class 'B' bricks , straight or curved on plan exc. 6 m mean radius built in CM 1:6 complete all as specified and directed.
M/L 15 mm thick cement plaster in CM (1:6) including finished even and smooth (without using extra lime or cement).
M&L preparation of surface and applying two coat of White wash on old wall surface all as specified and directed.
M&L Preparing old painted wooden surface and applying one coat of Synthetic enamel Paint all as specified and directed.
M&L Preparing new steel surfaces of any description and applying two coat of Synthetic enamel Paint over one coat of red oxide zinc chrome to steel surface all as specified and directed.
Demolition of cement concrete in ground floor and pavings nexc 15cm thickness (below or above ground level).
M&L for Forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’thickness of slab 100mm below.
M&L for Complete removal of existing wall surface finish and applying two coat of oil bound distember all as specified and directed.
Taking down carefully old unserviceable aluminium point wiring (light, fan, socket or power) complete, including fittings and fixtures such as switches, ceiling roses, light fittings, regulators, sockets etc, removing materials to store, or keeping in safe custody for re-use at site or offering credit,& making good disturbed surfaces of walls, floors, etc., all as specified and as directed.
Taking down carefully old unserviceable MBC DBs/metal clad sockets and offering credit including making good disturbed surfaces of walls, floors, etc., all as specified and as directed.
Point wiring completed with 1.5 sqmm single core PVC insulated heavy duty ISI Marked unsheathed copper conductor cable 1100 volts grade with multistranded copper conductor drawn through concealed PVC conduit and including provision of PVC Insulated heavy duty ISI marked Unsheathed copper conductor,1.5 sqmm for earth continuity conductor and connected to common earth dolly, including suitable size of sheet metal box 1.6mm thick fixed and flushed inside the walls, with 3mm thick laminated sheet top cover for housing the switches, socket outlets, fan regulators etc., for the following: -
(a) One light/exhaust/wall mounted fan point controlled by one 5 Amps switch
(b) One switch socket outlet point 3 pin 5 Amps on same board with other switches.
(d) One socket 6 amp on independent board.
(b) One ceiling fan/Exhaust fan controlled by one 5 Amps switch
All as per item No 90 above but wiring with 2.5 sq mm FRLS copper cable including earth continuty conductor with 2.5 sq mm FRLS copper cable for one 6 pin 15 Amps socket outlet on independent board controlled by 15 Amps switch.
All as per item No 90 above but wiring with 2.5 sq mm copper cable with 2.5 sq mm for one earth continuty cable for 6 pin 15 Amps socket out controlled by 15 Amps switch.
M&L for point wiring complete with 3 run of 4.00 sqmm single core PVC insulated heavy duty ISI Marked, FRLS, unsheathed cable 1100 volts grade with multistranded copper conductor drawn through and including rigid PVC conduit not less than 20mm dia and conduit accessories concealed/fixed to walls/roofs/floors/ceiling etc., and connected to common earth dolly for 32 Amps three phase Metal clad socket.
Supply and fix Modular switch 1 way 6A, 1 module type, 230 volts, ISI marked complete.
Supply and fix modular type Socket, 6A - 2/3 pin combined 2 module, multipurpose flush type, ISI marked complete all as specified and as directed.
Supply and fix modular type Socket 6A/16A - 2/3 pin combined 2 module, multipurpose flush type, ISI marked complete all as specified and as directed.
Supply and fix Modular switch 1 way 16A, 1 module, multipurpose flush type, ISI marked complete all as specified and as directed.
S & F Modular type stepped type electronic fan regulator, 120 Watt, 2 Module 230 Volts
Supply and fix modular white cover plate with frame, 1 module ISI marked complete all as specified and as directed.
Supply and fix modular white cover plate with frame, 2 module ISI marked complete all as specified and as directed.
Supply and fix modular white cover plate with frame, 3 module ISI marked complete all as specified and as directed.
Supply and fix modular white cover plate with frame, 8 module ISI marked complete all as specified and as directed.
Supply and fix modular white cover plate with frame, 4 module ISI marked complete all as specified and as directed.
Supply and fix modular white cover plate with frame, 6 module ISI marked complete all as specified and as directed.
Supply and fix modular flush metal box 1/2 module ISI marked complete all as specified and as directed.
Supply and fix modular flush metal box 3 module ISI marked complete all as specified and as directed.
Supply and fix modular flush metal box 6 module ISI marked complete all as specified and as directed.
S&F ceiling rose, three terminal, PVC/polycarbonate, isolated body, ISI marked complete.
Supply and fix LED lights fitting 20 Watt, 220V, 4 feet long, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge.
Supply and fix building security light LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP-66 protection complete all as specified and directed by Engr-in-Charge.
Supply and fix wall mounted cabin fan 400 mm sweep, 220-240 volt AC, 50 Hz sigle phase with Thermal overload Protected Motor and connecting up including provison of cabe from ceiling rose/connector to Wall fan all as specified and directed. Make. Polycab Model : Fantasy DLX or equivalent to Havells/Crompton.
Supply and fix exhaust fan, steel body AC single Phase 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed by Engr-in-charge.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc all as specified and directed by Engr-in-Charge.
M&L for sub-main wiring with four runs of 4 sqmm unsheathed PVC insulated, single core heavy duty ISI Marked FRLS cable 1100 volts grade with multistranded copper conductor drawn through and including not less than 25mm dia non metallic rigid PVC white conduit/casing caping and conduit accesories concealed/fixed to wall/roof/floor and including suitable PVC conduit with 4 sqmm copper earth wire, making good to the distrubed surfaces also matching the existing surfaces all as specified and directed. Note: 3 runs of cable and one run earth wire and conduit will be measured as one length or one Meter.
Supply and fix of metal clad socket outlet with single pole and neutral enclosure two pin plug socket complete with one double pole MCB 20 Amps 'C' Curve, 10 KA rupturing capacity complete all as specified and directed by Engr in charge.
Supply and fix sheet metal enclosures for MCB distribution board 240 Volts single pole and neutral 16 way double door with 200 amps rated bus bar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix sheet metal enclosures for MCB distribution board 240 Volts single pole and neutral 8 way double door with 200 amps rated bus bar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix MCB SPN 63 Amps, 240 Volts, 'C' Curve, 10 KA rupturing capacity.
Supply and fix MCB SP 5 to 32 Amps, 240 Volts, 'C' Curve, 10 KA rupturing capacity.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size 250 mm x 150mm x 40mm
Returning filling in excavated soil upto a depth of 30cm after riddling excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil complete as directed.
Supply and laying in trenches, floors, roof, ducts, LT underground cable of size 2 core 10 Sqmm XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands, jointing materials etc. and fixing using clamps, saddle for pole, wall etc.
Boring of holes under road, pavement, hardstanding by trenchless technology using ultrasound technique and necessary machine including GI pipe of 40 mm dia suitable for 0.4mpa working pressure.
M & L for Earthing complete with galvanised earth plate electrode of size 600x600x6 mm thick burried directly in ground earth pit not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected to 4 mm dia GI earth wire as earth lead upto a length of 7.5 metre long by means of bolts,nuts, washers etc. and protected by GI pipe light grade 15mm dia and 20mm dia GI tubing light grade with funnel for watering, all as shown in electrical plate No 3 of SSR Part-I, back-fill with salt and charcoal, provision of test point including connected to earth test point and necessary earth work excavation in any type of soil PCC (1:3:6) type C1 bed and chamber RCC (1:2:4) type B1, iron grill including GI cover with hinge and funnel watering pipe etc all as specified and directed by Engr-in-Charge.
Supply and fixing LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with highefficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp ceiling including connecting up with driver threesuitable for roof core flexible copper conductor cases of suitable size complete
Supply and fix sheet metal enclosures for MCB distribution board 230 Volts Single pole and neutral 4 way Double door with 200 amps rated bus bar complete including flushing the DBs inside the wall and making good to the disturbed surfaces and also matching with the existing surface all as specified and directed by Engr in charge.
Supply and fix single pole and netural encloser with a two pin and earth plug socket complete with one single pole MCB of 20 Amps.
Supply and fix MCB Single pole and Neutral, 240 volts, 32 Amps, 'C' Curve, 10 KA, including MCB Single pole and Neutral complete all as specified and as directed by Engr-in-charge.
Supply and fixing MCB Single pole, 240 volts, 6 to 32 Amps, 'B' Curve, 10 KA, including MCB Single pole and Neutral complete all as specified and as directed by Engr-in-charge.
M&L for point wiring complete with 1.5 sqmm single core PVC insulated heavy duty ISI marked unsheathed FRLS cable 1100 volts grade with multistranded copper conductor drawn through in stove enamelled steel conduit with all accessories fixed to the surface of walls/roof/floors/ceiling etc, MS terminal boxes 60 mm deep concealed in walls covered with plastic laminated top cover sheet 3.0 mm thick fixed with cadmium plated iron screws etc incl 1.5 sqmm PVC insulated, unsheathed copper conductor muistandere FRLS cable 1100V grade as earth continuity conductor & connecting to common earth dolly for one light/exhaust fan point controlled by one switch.
Supply and fix switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed by Engr-in-Charge
Supply and fixing LED light fitting 2x16/20 Watt flame proof, CMRI certified recommended for gas/vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughended glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size complete all as specified and directed by Engr-in-Charge
S&F flame proof exhaust fan 300 mm (12)" sweep heavy duty 1440 RPM, single phase 230 Volts AC 50 Hz and connecting up complete including louvers and provision of cable 3 core of size 1.5 Sqmm from ceiling rose to fan including wirting MES No 2 CM height with synthetic enamelled black paint complete all as specified and directed by Engr-in-Charge. Make : Cormpton/Havells/Usha/Sudhir
M&L for provision of hole on the wall for fixing of the exhaust fan and connecting with the ceiling rose complete all as specified and directed by Engr-in-Charge
SRI AYYAPPA ENTERPRISES
M/s BHOOMI ELECTRICALS
Lakkaiah Rangaswamy
SRUSHTI CONSTRUCTIONS
chowdeshwariconstructionco
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .