| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.5 LAccepted-AOC R 512 KEGAON BANDHILWADI TAL URAN DISTRICT RAIGAD NAVI MUMBAI 400 702 | RAIGAD | MAHARASHTRA | 400702 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹48.4 L+₹2.8 L (6.19%)Rejected-Finance 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L2 | Rejected-Finance NOT ADMITTED BEING L2 | |
| 3 | L3₹48.9 L+₹3.3 L (7.27%)Rejected-Finance | L3 | Rejected-Finance NOT ADMITTED BEING L3 | |
| 4 | L4₹50.1 L+₹4.5 L (9.96%)Rejected-Finance | L4 | Rejected-Finance NOT ADMITTED BEING L4 |
Tender Value
₹48.5 L
EMD Value
₹97,000
Closing Date
26 Sept 2024, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
SPECIAL REPAIR TO HILL TOP SECURITY WATCH TOWERS AND ASSOCIATED INFRASTRUCTURE AT PEER BABA AND SPECIAL REPAIRS TO STATIC WATER TANKS BLDG P 692 AND P733 1 AND AT INS TUNIR NAVAL STATION KARANJA
2024_MES_668361_1
8975/E8
Open Tender
Civil Works
Item Rate
180 days
GE NW KARANJA
D and above a i
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹97,000
Yes
5 Nov 2024
30 Aug 2024
28 Sept 2024
30 Aug 2024
26 Sept 2024
12 Sept 2024
Amount
Notes : (i) The work consists of 02 jobs as under:- JOB (A) : SO(K)/05/2024-25/SPL REP B/R JOB (B) : SO(K)/04/2024-25/SPL REP B/R (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department. (a) Tenderer shall employ skilled manpower who has experience in the field. The tenderer shall furnish the following:- (i) Manufacturers test certificate with name of manufacturer and details of original product. (ii) Test certificates from any approved laboratory as directed by GE. The testing charges shall be borne by the tenderer. (b)Quoted rate shall be inclusive of all material, labours, tools and plants, scaffolding and working upto 20m to 25m height. (c) Adoption of necessary safety arrangement like safety belts, ropes, helmets, netting etc. which are required for safety of working at any height of the building shall be mandatory and deemed to be inclusive on quoted rates. COMMON ITEMS FOR JOB 'A' & JOB 'B'
Demolition of pre-cast concrete block masonry built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed.
M&L for pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width in type B1 (1:2:4) using 20mm graded stone aggregate and setting in mortar (1:6) complete all as specified and as directed
Demolition of cement concrete (un-reinorced) in ground floors and paving not exceeding 15 cm thickness ( below or above ground level) complete all as specified and directed.
M&L for PCC 1:2:4 type B2, using 40 mm graded stone aggregate ,100 mm thick as in flooring complete all as specified & directed
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified & directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified & directed.
Preparing new or previously untreated steel surface of any description, over 10cm in width or girth and M&L for applying two coats of synthetic enamel paint over & including one coat of red oxide primer complete all as specified and directed.
M&L for applying jacketing around columns with Micro concrete M40 including all lifts, shuttering, drilling holes and fixing shear anchor as per specification complete all as specified and directed. Note: (i) Reinforcement shall be measured and paid separately. (ii)Rates including jacketing, formwork and micro concrete
Supply only liquid water proofing compound mixed with cement concrete/ cement plaster as per manufacture instruction complete all as specified and directed.
M&L for 60 mm Machine pressed pre casted pressed cement concrete inter locking paver blocks with grey cement and pigment glazed coloured up to 6mm on the top in any shape and size, strenth not less than M-35 complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for Chequered cement concrete tiles 30cm x 30cm x 25mm thick set jointed and pointed in neat cement slurry in floors or steps with in equal proportions & pigments with red and yellow colour over & including 15mm thick screed bed in CM 1:6 complete all as specified and directed
B/R ITEMS FOR JOB 'A'
Dismantling, floor, hearth or wall tiling including cement mortar bedding complete all as specified and directed.
M&L for non skid coloured ceremic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm, as in floors over & including bed or bedding layer of morar 15 mm in cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface complete all as specified and as directed.
M&L for vitrified tiles in patches matching with existing tile 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm in floors etc set and jointed in neat cement slurry and pointed in white/coloured cement to match over and including 10 mm thick screed bed in cement mortar in 1:4 complete all as specified and as directed.
M&L for Glazed ceramic tiles in vertical surface 350mmx250mm x7mm / 450X350X7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match with & including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
Dismantling of stone slabs & tiles of any description or thickness in floor aprons, cills etc laid bedded & pointed in any mortar complete all as specified and directed.
M&L for green marble 17/18 mm thick machine cut in skirting / dado,window sill, laid over cement screed, jointing and pointing with white cement slurry complete all as specified and directed.
M&L for granite (of any type) work 20mm thick (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platform, verticle surfaces and any position with & including 15mm thick bedding layer in cement mortar 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl chamfering and rounding of edges where required complete all as specified and directed.
M&L for machine cut kota stone kota stone slab flooring 20-25 mm thick over & inclduing 20mm thick cement screed base in cm 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for machine cut kota stone slab 15- 20 mm thick in riser of steps, skirting, dado and pillers laid over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing etc, with & including rendering 10 mm thick on vertical surface in cement mortar 1:4 complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1: 6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick/concrete surfaces cement plaster in CM (1:4) , finished even and smooth without using extra cement, complete all as specfified and directed.
M&L for rendering 5mm thick in CM 1:3 on ceiling surface complete all as specified and as directed
Preparing new plastered surfaces of walls and M&L for applying two coats of oil bound distemper over a coat of chalk whitening on plastered including preparing surfaces with application of putty wherever required complete all as specified and directed.
Preparation of new or previously untreated plastered surfaces of walls and M&L for applying two coats of acrylic antifungal paint exterior grade paint of camouflage pattern over one coat of primer complete all as specified and directed.
Preparation of new plastered surface of ceiling and M&L for applying three coat of white wash on ceiling complete all as specified and directed.
Prepration of old plastered / decorated surfaces of walls and M&L for applying one coat of oil bound distemper on plastered/decorated wall surfaces complete all as specified and directed.
Preparation of old wall surfaces of any description and M&L for applying one coat of acrylic (antifungal) exterior grade paint of camouflage pattern complete all as specified and directed.
Preparation of old white washed plastered or unplastered surfaces of ceilings including cornices, pillasters etc and M&L for applying one coat of white wash on ceilings complete all as specified and directed.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) not exceeding 1.5 Square Metre each , removing from the site including cutting holes required for taking out existing hold fast etc. complete all as specified and as directed.
Taking down chowkhat or frame with shutter (without taking off shutter from the frame) exceeding 1.5 sqm not exceeding 4.0 Square Metre each , removing from the site including cutting holes required for taking out existing hold fast etc. complete all as specified and as directed.
S & F 2nd class hard wood plain solid straight chowkats and frame of wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
S & F 30mm thick second class hard wood plain, framed,panelled shutters(any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and as directed.
S&F 2nd class hard wood 35 mm thick Glazed and skelton shutter open rebated and prepare to receive glass, wire mesh, gauze etc. (without sash bars) edges of framing plain, chamfered or rounded fitted with and cut and mitered beads, for securing glass sizes of members of shutters as specified in SSR Part I Sec 8 Clause 8.24(a) supply and fitted to chowkats complete all as specified and directed.
S&F aluminium alloy wire cloth, 0.45mm dia of wire and average width of aperture 1.40mm and fixed with aluminium staples complete all as specified and as directed
M&L for cutting holes in brick wall for inserting holdfast and making good dismantled portion by filling PCC (1:2:4) type B-1 exc. half brick but n.exc one brick and making good as per exisiting complete all as specified and as directed.
S&F mild steel work, Grade Fe-410-0 or Fe- 310-0, as in flat iron (for holdfast) complete all as specified and directed.
S&F solid PVC door frame of size 50mmx 47mm made out of 5mm wood grains printed PVC sheet reinforced with MS square tube and edges painted to match with printed sheet complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30 mm thick (styled) consisting of frame made out of MS tube for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC ,C" channel having a PVC sheet strip of 20mm width stuck in side with solvent cement for styles and plain colour PVC sheet for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles and rails with suitable PVC sheet bedding and jointed together with solvent cement supplying and fixing in the frame at site complete all as specified and directed.
S&F aluminium door/window/ventilator/partition, made out of extruded powder coated aluminium sections, with sliding or openable shutters including frame & necessary jointing cleats, glazing clips, powder coated aluminium snap beading, screws etc; complete and also including powder coated aluminium fittings such as cobra hinges, butt hinges, tower bolts, hooks & eyes, peg stays and handles including connected items, with and including rubber beading for 4 or 5mm thick glass, making good to the disturbed portion with its original specifications, complete all as specified and directed.
S&F for aluminium anodised grill of design DG 104 pattern made out of 10mm dia rod fixed with and including standard aluminium frame of F section of size 23.40mmx15.30mm & 1.4mm thick all as per manufactures instructions complete all as specified & directed.
S&F Pre-laminated 18/19 mm thick partilcle board, exterior grade, prelaminated both sides with decorative choice lamiantions complete all as specified and as directed.
S&F butt hinges type C-21 size 100 extruded aluminium alloy with galvanised mild steel hinges pin anodised complete all as specified and as directed.
S&F Aluminium handle, cast type anodized size of handle 150 mm complete all as specified and as directed.
S&F Aluminium anodized, barrel tower bolt of extruded section, length of bolt 150 mm complete all as specified and as directed.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed length of bolt 250 mm complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint on new wooden surfaces of any description over 10 cm width or girth over & including a coat of pink primer and preparation of surfaces complete all as specified and directed.
S&F in repair PVC flushing cistern of 10 ltrs capacity including flush pipe PVC connection etc complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan (Pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed.
S&F in repairs Vitreous china wash basin white , flat back size 550 X 400 mm including brackets including cutting for and pinning in ends of brackets or erecting stand including PTMT 32mm waste coupling and waste pipe including 15 mm bore pillar taps cast copper alloy with capstan heads chromium plated screwed down high pressure with long screws shanks and fly nuts complete all as specified and directed.
S&F in repairs 15 mm dia PVC connection 450mm longwith brass fly nut complete all as specified and directed.
S&F CPVC water tubing outerdia 20 mm bore pipe, SDR 11 including provision of all fittings and connected completed in concealed and surface, along with primer & slovent cement for joint as per ASTM D 2564, pipe material shall be as per ASTM D 1785, fitting/ flanges shall be as per ASTM D2467, including taking down old GI tubing in concealed and surface complete all as specified and directed by Engr-in-charge. Note:-Pipe and fittings made from CPVC shall be clearly marked with manufactures name and trade mark. manufacturer test certificate (MTC) shall be provided.
All as per BOQ Serial item No 2.42 above but outer dia 25 mm bore CPVC pipe, complete all as specified and as directed
S&F in repairs bib tap 15mm bore long body cast copper alloy fancy type chormium plated butter fly handle screwed down complete all as specified and as directed
S&F in repair angle/ stop valves 15mm bore (for iron pipe) fancy type chromium plated screwed down high pressure with butterfly handle screwed both ends complete all as specified and as directed
S&F 75mm dia PVC (SWR) floor traps, plain with grating including jointing to waste pipe with solvent cement complete all as specified and directed.
S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 meter long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
S&F Mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; ailings; framework of water tanks and similar work conforming to Fe.410-0, FE-310-0. complete all as specified and directed.
Chipping , removing carefullly concrete work by low impact hammer ,breakar without damaging the structure & cleaning and disposal of debries outside the premises etc. complete all as specified and directed. Note :-Hard concrete should not be removed by force.
Clean existing reinforcement with wire/ rotary wire brush, making the surfaces free from loose material dirt etc. complete and M&L for applying two coats of alkaline rust converting primer (Make :- FEOVERT of Krishna Conchem or Roff rust cleaner of Piddilite or Dr. Fixit Rust removal or ShaliRust of STP Ltd as approved by GE). on the rebars, including cleaning the reinforcement, wirebrushing to remove loose rust spalls, wash the rebars with clean water within 3 min and wipe it dry complete all as specified & directed.
M&L for applying two coats of Epoxy based Zinc primer in a span of four hours over the treated rebars and allow to dry for six hours. (Make : - Corroseal-ZR of Krishna Conchem or Dr. Fixit Epoxy zinc primer as approved by GE) by brush complete all as specified & directed.
M&L for cleaning all loose laitance on the concrete substrate and applying one coat of epoxy bonding agent (Make :- monobond SBR of Krishna Conchem or Dr. Fixit epoxy bonding agent or Shalicrete URP of STP Ltd. as approved by GE) on exposed concrete surface to ensure bond between old concrete & new concrete by brush application complete all as specified & directed.
M&L for Building up the profile of structural members by using latex additives(MONOBOND) modified air cured mortar system (Polymer modified mortar) (1:5:15 = 1 monobond-5Cement-15 sand) -in damaged areas in 30mm thickness including leveling profliling etc complete all as specified & directed.
M&L for applying concrete protection coating on finished structural members exposed to atmosphere (Make :- IPNET of Krishna Conchem or New Coat from Dr. Fixit as approved by GE) complete all as specified and directed.
M&L for Drilling and fixing Rohibb Teflon nozzles in RCC members, including drilling holes of 12mm dia, 50 to 100mm deep holes. Works shall be carried out as under :- (i) Cleaning of holes. Clean the holes by air blower prior to fixing nozzles. (ii) Fixing of nozzles. Insert 12mm dia. Rohibb Teflon nozzles in cleaned holes. External end of nozzles to be machine to receive outlet of grouting gun.Fix it inside the holes by applying thixotropic epoxy putty to ensure complete sealing. Cure the system for min.12 hrs. (iii) Cutting of nozzles. Cut the nozzles by chisel after completion of grouting without damaging structural elements. (iv) In case crack upto 2mm wide, fix the injection nozzels directly over the cracks, at intervals of 6 to 9 inches, using a drilling machine. Fix PVC/MS nozzels in these holes with fast-setting epoxy putty & let it dry for 2 to 3 days. Also, seal the crack between the ports with epoxy putty. (v) In case where the crack is wider than 2mm upto 4 to 5mm, drill holes at the sides of the crack in a staggered fashion, at intervals of 6 inches and affix them with epoxy putty as mentioned above. (vi) Also, seal the face of the carck with a liberal application of the epoxy putty.
M&L for Injecting of site mixed cement slurry grout, mixed in specified proportion containing cement, sand water with addition of plasticizers (Make :- Epoxy grout - Dr. Fixit Epoxy injection or EPCO KP-HP-250 of M/s Krishna Conchem or Shaligrout EI of STP Ltd as approved by GE) & migratory corrosion inhibitors, water cement ratio shall be varied between 0.5 to 1.0 for each hole, shrinkage compensating cement slurry mixed to a lump free fresh creamy consistency ,Mixing shall be done by mechanical mixer continuously stirring mechanically to keep cement particles in suspension. Injection of approved/specified grout by means of pump at a pressure of 3-5 Kg/cm2 etc complete till the grout mix flows out from the nozzle indicating complete filling of grout in the holes drilled complete all as specified and directed.
M&L for Injecting low viscosity (3-5cps) high molecular weight monomer by pressure and using mechanized injector gun with accessories till nozzles refuses to accept the grout, Including,Mixing of materialas:Mixing of material components(part a&b) in the required quantities as per manufacturer's instruction by weigh batching.Grouting:Fill the grouting gun with concrete penetrating corrosion inhibitor (Make :-EPCO-KP-100/Protectsil CIT or Ferogard 903 as approved by GE). Maintain desired pressure in the gun by air compressor; maintain the pressureat exit(2 to 3kg/cm2) by monitoring pressure guage at exit.Grout the material through prefixed nozzles in the structural elements@ 100ml per nozzle. Repeat the process for all the nozzles omplete all as specified and directed. .
M&L for replacement of steel reinforcement with TMT bars of appropriate size where 30% of cross section is reduced including dismantling of rusted steel complete all as specified and directed.
Complete Removal of existing water proofing treatment ofany description up to concrete surface of roof slab including cleaning, with wire brushing, watering, removal of debris upto 1500 m distance complete all as specified and directed NOTE :- Unit rate quoted shall also include for removal of PVC water storage tank wherever existing carefully and refixing at the same or other position after completion of roof repair work
M&L for cleaning the new surfaces concrete with wire brushing and applying water proofing treatment as under complete all as specified and directed.:- (i) Apply oil bound bitumen primer @ 0.30 Litre/Sqm manufactured by the same agency as that of APP with density of 0.87 to 0.89 Kg/Litre at 25 degree cesius on the pepared dry roof surface. (ii) Laying torch applied APP polymer modified membrane 4mm thick with non-wooven ployster mat as reinforcement weighing n.less than 3.50 Kg/Sqm mineral finished by thermo fusion process all as decribed under particular specification (iii) Over the membrane, provide a finishing with two coats of Solar reflective bituminious aluminium paint @ 0.10 Kg/Sqm as prescribed by manufactures. Note :- work shall be executed by authorised applicator
M&L for rendering 10mm thick cement plaster in CM (1:3) on roof top surface including WPC by weight of 3% of total cement content complete all as specified and as directed. Note : WPC will be measured separately
Demolition of cement concrete (unreinforced) roof or chajja padding of any description and any position not otherwise specifically provided for complete and PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) as in roof/chajja padding for maintaining roof/chajja slope complete all as specified and as directed.
S&F rotational moulded polythene water storage tank of 1000 ltrs capacity (cylinderical vertical with closed top)two layered with ISI branded hoisted and including all accessories (union, washer coupling, tank nipple etc) covers, connecting up pipes fixed in position all as specified in SSR Part - 1 including dismantling of water tank capacity 1000 ltrs complete all as specified and directed.
Dismantling plain or corrugated steel sheeting ,any gauge ,thickness including Nainital or similar pattern roof covering complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tenstile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws as complete all as specified and directed.
S&F pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.5mm thick of colour as approved having tenstile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
Demolition of cement concrete in ground floor and paving not exceeding 15cm thick below or above ground level un re-inforced complete all as specified and directed. .
M&L for PCC 1:4:8 type D2, using (40 mm graded agg) , 75mm thick as in sub base of flooring complete all as specified and directed.
S&F Steel work in tubular trusses, pillars and purlins including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S 1161-1979 grade St.-240 complete all as specified and directed.
E/M ITEMS FOR JOB 'A'
Taking down carefully copper / aluminium point wiring (light, fan socket or power) through steel / PVC conduit / casing caping including complete fittings such as switches, ceiling roses, pendants, regulators, sockets, buzzer, bell, switch sockets, etc and making good to the disturbed surfaces of walls/ceiling etc, with its original specification complete all as specified and directed.
M&L for point wiring with single core 1100 volts grade 1.5 sqmm size PVC FRLSH insulated unsheathed stranded copper conductor cable using color code drawn through concealed PVC conduit with all accessories with in and including sunk type pressed steel/CI terminal box with 3mm thick Mansonite sheet top cover / PVC Board including 1.5Sq mm PVC FRLSH insulated unsheathed copper conductor cable for continous earth conductor (using green colour)to common earth and connecting to earth dolly for the following complete all as specified and directed. :-
One light /fan/ call bell point controlled by one switch
One 5 pin socket outlet 5 Amps on independent board
One 5 pin socket outlet 5 Amps on same board
All as per BOQ Serial item No 3.02 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLSH PVC insulated sheathed cable with FRLSH PVC 1.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board.
S&F switch piano flush button single pole one way, 6 Amp complete all as specified and directed.
S&F socket 2 in 1, 3 pin, 6 Amp flush type a complete all as specified and directed.
S&F switch socket outlet 15 Amp, 5-in-1, controlled by one switch complete all as specified and directed by
S&F ceiling rose surface bakelite 65 x 50mm, three terminals complete all as specified and directed.
S&F EME rotary step fan regulator suitable for operation in 230 V, AC, 50 Hz complete all as specified and directed.
S&F 6 to 32 AMP MCB single pole 240 V 10 KA (C-Series) complete all as specified and directed.
S&F MCB RCBO 240 volts AC 40 Amps,100 Ma, 50 Hz ccomplete all as specified and directed.
S&F in replacement MCB DB, SPN, double door 8 way, 230 Volts as per IP-42 complete all as specified and directed.
Supply, fixing, stringing and drawing submain wiring with 2 run of single core 6 Sqmm PVC insulated and unsheathed, multi stranded FRLSH copper conductor cable using colour code for phase red and neutral black with and including 6 Sqmm PVC insulated and unsheathed copper conductor multistranded cable in green colour connected to common earth point and connected to earth dolly drawn through conceiled 20 mm PVC conduit, heavy grade (ISI marked) with and including all accessories etc in replacement compete all as specified and directed NOTE:- Two run of 6 sqmm, one run of 6 sqmm earth continuity conductor and 20 mm PVC conduit conceiled to wall and accessories shall be measured and paid as one length.
S&F in repairs surface and wall mounted LED batten of 22 W with polycarbonate housing & integrated electronic driver having THD<20% complete all as specified and directed.
S&F in repairs LED building security light fitting with suitable size bracket/angle to fit security light of 60w IP 66 protection LED complete all as specified and directed
Taking down ceiling fan/exhaust/wall fan and keeping in safe custody for refixing the same including duly painted and necessary repair work like greesing work etc complete all as specified and directed by engr-in-charge.
M&L for refixing the ceiling fan/wall fan/exhaust fan taken down against item above and connecting with the ceiling rose with proper size flexible black colour copper wire complete all as specified and directed .
Supply only Pedestal fans air circulators 750mm sweep heavy duty, 230V, 50Hz, with all accessories complete all as specified and directed.
S&F non metalic exhaust fan single phase 300mm sweep and all connected accessories and making necessary cutting and chasing to make holes on wall to fix the fans comlplete all as specified and directed
M & L earthing complete with GI earth plate electrode of size 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below the normal ground level connected with GI strip 32 x 6 mm by means of bolts, nuts, check nuts & washers of galvanished iron steel including necessary excavation and earth work in any type of soil, removing surplus soil to a distance not exc 50 m, with and including PCC chamber in PCC (1:2:4) , type B1, using (20 mm graded stone aggregate), mild steel angle iron frame made out of MS angle iron of size 40x40x6 mm thick duly painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer hinged with and including 6mm thick CI cover with handle, watering arrangement with funnel internally secured with wire mesh with 20 mm dia medium grade pipe for watering ,40 mm dia light grade GI pipe for lead protection in & including alternate layers of charcoal dust and common salt complete all as shown in electrical plate No 3 of SSR Part-1(2009) connected to earthing test point all as specified and indicated including testing on completion Note : (i) The unit rate includes for protection pipe and GI strip from top of earth plate up to 7.5 meter above ground level and also the cost of the Test point. (ii) Joining of GI earth strip with pipe of the test point shall be done by using suitable cable lugs.
S&F 2mm thick CRCA sheet panel box of size 75cmx65cmx 25cm single door to accommodate DB with all accessories complete all as specified and directed Note-The rates includes taking down old DISTRIBUTION BOARD and accessories and refixing the same with out any extra cost.
Dismantling of existing panel including disconnecting connected cables, etc. and Supply, Installed, Testing and Commissioning CPRI approved cubical type LT Panel floor mounted out door type for 415V, 3 phase 4 wire sysytem 50 Hz AC supply, factory made fabricated from 3.15mm thick CRCA sheet totally enclosed, dust weather proof and vermin proof for outer shell having TPN aluminium bus bar rating 1.5 times that of controlling MCCB supported on SMC insulator with short circuit withstand capacity 1 MVA for 1 second, bottom base channel MS section not less than 100mm x 50mm x 5 mm thick, entire panel shall have a common aluminium earth bar of size 25mm x 5mm at the rear with 2 Nos earth stud, solid connection from main bus bar to switchgears with required size of copper wiring with minimum 2.5 Sqmm PVC insulated copper conductor cable , cable alleys, cable gland plates in two half and general construction confirming to IS-8623/93 and mounted on suitable PCC foundation with follwoing detailed specification & control complete all as specified and diercted with the following accessories :-
OUTER SHELL :- The outer shell shall be made of 3.15 mm thick CRCA body & MS angle section 50x50x6 mm frame with front & back openable, single door system lockable/ openable by keys from both sides having flush pattern fancy locks with louvers & air vent gasket for natural flow of air. The bottom of the outer shell contains a detachable plate having provision for entry of armoured cable of adequate size of glands. The dimension of the outer shell shall be adequate to accommdodate inner shell described below 50 mm space all around and shall be fabricated in such a way that the complete inner shell alongiwth its control gears and accessories should be taken outside without disturbing outer sheel. The outer shell shall be mounted on a zinc metal coated stand. Provision of threaded earthing studs at bottom and lifting lugs of suitable size at top to lift the feeder pillar box safely shall be made. Computer cut self adhesive vinly danger notice plate having conventional symbol of bone and skull shall be provided. The degree of protection of outer shell shall be IP-65. INNER SHELL :- Inner shel made of 2.0 mm thick CRCA body compartmentalized for each control gear, front openable single door system lockable/openable by keys from both sides having chromium plated fancy locks (2 Nos in each compartment) having louvers and air vents gasket for natural flow of air "U' type gasket shall be used to make the inner shell completely vermin proof and to accomodate incomer/outgoing MCCB's and TPN aluminium bus bar and extension links of rating not less than the 1.5 times rated capacity of the respective MCCB's. The TPN bus bar and exension links shall be insulated with colour coaded heat, shrikable sleeve and shall be mounted on suitable size 'F' class through out the length of the TPN bus bar. Computer cut self adhesive vinyl danger notice plate having conventional symbol of bone and skull shall be provoid on bus bar chamber. All control wires shall be with not less than 2.5 Sqmm multistranded copper conductor and shall be properly bunched, tied, ferruled for proper identification and crimped with adequite size of lugs. The cubical shall have a bottom channel of size 75x50mm duly coated with zinc metal coating. A detachable predrilled gland plate of thickness 3.15 mm zinc metal coated should be used at the bottom, indicating lamps LED type, 230 Volt, AC at the incomer of the unit to show three phase availablity at the incomer. The degree of protection for inner shell shall be IP-42 and carry the following control :-
(A) INCOMING (i) MCCB 100 A, microprocessor based , 4 pole, 415 volt, 50 kA breaking cap. With adjustable over load,short circuit ,ground fault (4 pole) & fixed instantanous neutral protection(4 pole), conforming to IS/IEC-60947-2 including spreader terminal kit – 01 No. (B) OUTGOING (a) MCCB 40 A, microprocessor based , 3 pole 415 volt, 35 kA breaking cap. With adjustable over load,short circuit ,ground fault & fixed instantanous neutral protection, conforming to IS/IEC-60947-2 including spreader terminal kit -03 Nos(2 W + 1 spare ) (b)Digital type Voltmeter three phase class 0.5, 96X 96 mm flush mounted case with adeqaute CT arrangemnt - 1 No (c)Digital type Ammeter three phase class 0.5, 96X 96 mm flush mounted case with adeqaute CT arrangemnt - 1 No (d) LED INDICATORS RIBBED LENS WITH TRIMMED COLLAR - Red, Yellow and Blue - 1 Set (RYB) (e) Aluminium bus bar of Rating 200 Amp R-Y-B phases and Neutral. (f) Base frame for cubical mounting made out of suitable size equal angle iron duly painted. (g) Foundation for the panel should be provided with PCC 1:2:4 using 20mm graded stone aggregate at a depth of 150 MM below G.L. and 100 MM above the G.L. with slot openings for I/C and O/G cables.
ITEMS FOR JOB 'B'
M&L for dewatering the sump and reservoir completely to make dry and cleaning of reservoir tank , removing sludge in semi-solid state or liquid state by manually or by pressure pump including necessary arrangement of pump, and removal of sludge, if any, to a distance exc 1.5kM but nexc 5Km outside MD land complete all as specified and as directed.
M&L for chipping and cleaning of existing loose and damaged concrete surface or plaster surface carefully upto 60 mm thickness by low impact high frequency hammer or by manual chipping without damaging the existing concrete/surface including cleaning the surface by air jet and stacking & disposal of unserviceable materials outside the premises of MoD land etc complete all as specified and as directed
M&L ready mix plaster 15mm thick in cement mortar 1:4 on fair faces of brick/concrete surfaces on walls, finished even and smooth without using extra cement complete all as specifed and as directed.
M&L ready mix plaster 20mm thick in cement mortar 1:4 mixed with and including integral liquid water proof admixture @ 200ml per bag of cement on fair faces of brick/concrete surfaces of wall, finished even and smooth and with moist curing complete all as specified and directed.
M&L ready mix plaster 10mm thick in cement mortar 1:3 mixed with and including integral liquid water proof admixture @ 200ml per bag of cement as in ceiling, finished even and smooth without using extra cement and with moist curing of the surface complete all as specified and directed.
M&L for welded MS wire mesh weighing not less than 1 kg/sqm on the prepared surface which should be cleaned and should be removed from dirt, fungus and all foreign material complete all as specified and directed
S&F rolled mild steel work in joist, channel, angle or tee section, fixed indepently without connecting plates etc (cut to ordinary lengh i.e. withing 20mm of the length indicated ) including necssary welding and joints etc; steel confirming to Fe-410 Gde E-250 quality B complete all as specified and directed.
Dismantling expanded metal,/welded wire fabric n.exc 4 kg per sqm any thickness or mesh, fixed with steel or wood fillets, if any complete all as specified and as directed
S&F Welded steel wire fabric n exc 4 kg per Sqm and fixed to wood or steel members complete all as specified and as directed
Demolition of cement concrete of any type and in any position for below or above ground floors.complete all as specified and directed
M&L for PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in 75mm thick as in plinth protection/footpath. finished even & smooth using extra cement complete all as specified and directed
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping, kneelers, apex,stones, bed plates, kerbs and likes including weathering, slightly rounded or chamfered angles and throating with & including necessary form work, complete all as specified and directed.
M&L steel deformed bars(TMT bars) 10mm dia & over in reinforcement, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends & binding with & including mild steel wire (annealed) not less than 0.9mmdia or securing with clips complete all as specified and directed.
M&L for wire brushing, cleaning the surface from loose dirt, mortar dropping etc apply one coat of primer AC 10 pure acrylic seater allow to dry for 4-5 hrs. Thereafter, applying two coats Anti-carbonation coating (Make :-Chemistik ACP 100 or equivalent as approved) and allow to cure for 72 hrs. complete all as per manufacturer instructions complete all as specified and directed . Anti-carbonation coating having the following properties :- (a) Vapour permeability - < 0.13 ASTM D1653 (b) Diffusion resistance Co2: Min : 22.00g/(sqm d) (c) Diffusion air layerthickness : Min 11.00/m Din (d) 53122 pt I adhesion min: 2.00 ASTM d-4541 (e) Tensile strength Min 1.5 Mpa (f) ASTM D 2370 , allow to cure for 72 hrs.
M&L for filling all visible cracks joints in floor slab etc with Polymeric joint sealeant (Make :- Chemistik Conjioint 50 or equivalent as approved) by first priming with polymeric joint primer (make : Primer 10 or equivalent as approved). Thereafter, apply one bond coat Epoxy Tac Coat (Make :- Chemistik EP TAC 404 or equivalent as spproved) prior to laying M-15 concrete in 30mm thickness laid to level to finish. Allow to moist cure for 7 days complete all as per manufacturer specifications and as directed.
M&L for applying on new concrete or plastered surfaces one coat of tank waterproof coating (Make :- Chemistik CW 100 G or equivalent as approved) ,allow to cure for 72 hrs. Thereafter, applying three coats of Chemistik Epoxy Slurry mortar heavy duty tank coating at an interval of 4-6 hrs between each coat complete all as per manufacturer specifications and as directed.
M&L providing the following treatment to water reservoir complete all as per manufacturer specifications and complete all as specified and directed :- (i) Wire brushing, cleaning the surfaces of walls , removing loose dirt, dust, gravel etc on external top and side wall surfaces. (ii) Fill all cracks, joints with Chemistik Primer 10 and filling the same with Chemistik Conjoint-50 (Polymeric joint sealant) , allow to cure for 72 hrs. (iii) Apply one coat of Chemistik CW-100G (Tank water proof coating) allow to cure to 24 hrs. (iv) Apply two coats of Chemistik ACP 100 (Anti-carbonation paint) allow to cure for 72 hrs . Anti carbonatnion coating to have following properties:- (a) Vapour permeability - < 0.13 ASTM D1653 (b) Diffusion resistance Co2: Min : 22.00g/(sqm d) (c) Diffusion air layerthickness : Min 11.00/m Din (d) 53122 pt I adhesion min: 2.00 ASTM d-4541 (e) Tensile strength Min 1.5 Mpa (f) ASTM D 2370 , allow to cure for 72 hrs.
M&L for scaling/volumetric marking with thick paint on internal surfaces of static water tank/ mild steel surface including all necessary preparation . complete all as specified and directed.
M&L for applying Epoxy Resin Based Concrete Bonding Agent for proper bonding between old surface with micro-concrete/new surface. The bonding agent shall be a two component solvent free epoxy supplied as ready to use at site. The product shall have a minimum pot life of 120 Min at 35°C and an open time of atleast 4-6 Hours @ 30°C up to which new concrete can be poured. It shall develop a minimum compressive strength of 40 MPa and a bond Strength of 11 MPa complete all as specified and directed. Make: Carlisle Syntec/Thermax Ltd,/Kryton Build Mat Pvt Ltd/SNI Infratech Pvt. Ltd or equivalent as approved.
M&L for applying ready to mix cement polymer plaster with high quality polymer additives (Polymer plaster) with 4 MPa compressive strength of required thickness over the entire cleaned surfaces including all tools and tackles, etc. in damaged areas in 40 to 50 mm thickness including leveling profliling etc complete all as specified and directed. Make:- Krishna Conchem, STP or equivalent as approved.
M&L for PCC 1:4:8 type D2, using (40 mm graded stone aggregate) , 75mm thick as in sub base of flooring complete all as specified & directed
Supply only Metallic floor hardener complete all as specified and directed
M&L for machine cut broken stone or boulders of gauge not exc 63mm as in hard core n exc 150mm thick spread and levelled including watering & ramming complete all as specified and directed.
Sagar Electricals (BID ID -3098518)
Shri Krishna Trading Corporation (BID ID -3097037)
K N CONSTRUCTION (BID ID -3099528)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .