Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC 10 1 GROUND FLOOR WEST GHOSH PARA JAGATDAL JAGATDAL JAGATDAL NORTH 24 PARGANAS WEST BENGAL 743125 | 24 PARAGANAS NORTH | WEST BENGAL | 743125 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹23.7 L+₹34,484 (1.47%)Rejected-Finance 44B CIRCULAR GARDEN REACH ROAD KOLKATA 700 023 | KOLKATA | WEST BENGAL | 700023 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹24.2 L+₹79,520 (3.40%)Rejected-Finance 3 IBRAHIM ROAD KHIDDERPORE KOLKATA 700023 | KOLKATA | WEST BENGAL | 700023 | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹25.8 L+₹2.4 L (10.2%)Rejected-Finance 22 2 BAKRAHAT ROAD THAKURPUKUR KOLKATA 700063 | KOLKATA | KOLKATA | WEST BENGAL | 700063 | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | L5₹27.2 L+₹3.8 L (16.4%)Rejected-Finance GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹24.5 L
EMD Value
₹49,000
Closing Date
13 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
LT COL SAURBH GUPTA
GARRISON ENGINEER (CENTRAL) KOLKATA T37 NAPIER ROAD HASTING KOLKATA 700022
SPL REPAIR TO COOLING APPLIANCE AGAINST BER UNDER GE (CENTRAL) KOLKATA
2023_MES_623560_1
8657/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
KOLKATA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (C) KOLKATA
₹49,000
Yes
18 Mar 2024
16 Oct 2023
14 Nov 2023
16 Oct 2023
13 Nov 2023
1 Nov 2023
16 Oct 2023 - 31 Oct 2023
Amount
Taking down point wiring (light, fan, socket and power complete including fixtures and fittings such as switches ceiling roses, pendents , regulators, sockets, light fittings etc. removing materials to store for keeping in safe custody for refixing or for taking credit (credit for above items should be made as per conditions separately) and making good distrubed surfaces of walls, floors, etc.complete all as directed by Engineer-in-Charge.
M&L Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 2.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC casing caping of suitable size with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 2.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan /call bell point/ Switch socket outlet 5 amps complete all as specified and as directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board..
M&L Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 4.0 sqmm to IS - 694 1990 drawn through and including PVC casing caping of suitable size with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 4.0 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly for 3 pin 15 amps complete all as specified and as directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board..
S&F Plug and socket in sheet metal enclosures with two pin and earth plug and socket complete with and including MCB SP 20 Amps 240 volts heavy duty ne complete all as specified and as directed by Engr-in-charge.
S&F MCB 6 to 32 Amps, SP, 240 Volts , 'C' curve breaking capacity 10 kA complete all as specified and as directed.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 4.0 Sqmm as earth lead drawn into rigid non metalic PVC conduit of size 20 mm dia including all fittings complete all as specified and as directed. Note:- Two runs of 4 Sqmm conductor as main wire and one run of 4 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit.
Supply and install Split unit complete of capacity 1.5 TR with minimum 5 star rating EER 3.2 with connecting copper pipe with complete insulation, drain pipe ,cordless remote control unit with in built air ioniser and Plasma filter for better indoor air quality complete all as specified and as directed. Note:- All drilling and hole work is included in quoted rate and will be matched with existing one.) Old US AC to be deposited to MES Store.
Supply and install Split unit complete of capacity 2 TR with minimum 3 star rating EER 3.2 with connecting copper pipe with complete insulation, drain pipe ,cordless remote control unit with in built air ioniser and Plasma filter for better indoor air quality.complete all as specified and as directed. Note:- All drilling and hole work is included in quoted rate and will be matched with existing one. Old US AC to be deposited to MES Store.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 300 V wall mounted design digital display with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA. complete all as specified and as directed. Make Microtek 1.5 TON AC STABILIZER PEARL MCU 4130+ or equivalent. Note- Old US Voltage stablizer to be deposited to MES store.
Supply install testing and commissioning of water cooler partially stainless steel electric driven single phase having approx storage and nominal cooling capacity 150/150 ltrs complete all as specified and as directed. Note- Old US Water cooler to be deposited to MES store.
Supply install testing and commissioning of water cooler partially stainless steel electric driven single phase having approx storage and nominal cooling capacity 40/80 ltrs complete all as specified and as directed. Note- Old US Water cooler to be deposited to MES store.
Supply and fix refrigerator, electric driven (single phase), min capacity 310 Ltrs, 2 star double door frost free complete all as specified and as directed. Make LG Model No. GL-T342TPZY or Voltas beko model no.1100177 / RFF363IF. Note- Old refrigerator to be deposited to MES store.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 130 V to 295 V with output voltage stabilized at 230 V with accuracy of ± 2.5% LED Display wall mounted and of capacity 1 KVA.complete all as specified and as directed. Make Microtek Model No. Automatic Voltage Stabilizer EMR 4013 or equivalent in V Guard Model No. VBS 50 Note- Old US Voltage stablizer to be deposited to MES store.
S & F Variable refrigerant flow system (VRF AC) comprising of inverter scroll compressor with single outdoor unit and wall mounted indoor units (Total 7.5 TR refrigeration effect) with indoor seperation tubes and cordless remote including installation, testing and commissioning of following items including all civil work including foundation. (a) Interconnecting refrigerant Suction / Liquid copper pipe work with (suitable size ) closed cell elastomeric nitrile rubber tubular insulation . complete with all necessary work (b) PVC drain piping 10 Kg pressure rating complete with fittings, supports of necessary size and insulated with 6 mm Nitrile rubber insulation etc. (c) Control cum transmission wiring of copper wire 1.0 SQMM X 2 CORE with PVC Conduite Pipe along with all accessories complete as required. (d) Refrigerant R410a Gas for VRF Systems along with pre- Vaccum systems , Nitrozen pressure testing with all respect .
INDIA ELECTRICAL EQUIPMENTS
M/S J S ENTERPRISES
ELECTRO FREEZE
KWALITY CONSTRUCTION
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .