Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance NO 18 BHARATHI STREET WEST GANDHI NAGAR AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Rejected Being not enlisted in reqired cat |
Tender Value
₹8.7 L
EMD Value
₹17,400
Closing Date
29 Jan 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I RD AVADI
AGE I RD AVADI, AVADI CHENNAI 6000054
REPAIR AND MAINTENANCE OF HT ELECTRIC SUPPLY AT RESIDENTIAL AREA CVRDE AVADI
2021_MES_486646_3
8460/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
AVADI
As per NIT
8 documents required · 8 mandatory
₹500
AGE I RD AVADI
₹17,400
Yes
9 Feb 2022
10 Jan 2022
31 Jan 2022
10 Jan 2022
29 Jan 2022
15 Jan 2022
10 Jan 2022 - 15 Jan 2022
60 days
Amount
M&L for Servicing HT VCB panel cum breaker 1250/800/630A 13.1KA rating Indoor type make of SEIMENS/ CROMPTON/SCHINDER after taking proper shut down permission in writing and disconnecting the cables from panel draw out VCB breakers, earth fault relay, checking alignment of VCB isolating contact, servicing of operating mechanism including tripping and closing system of the breakers, dehydrating, decarburizing of panel, bus bar section & circuit section including incoming/ outgoing cables, provide necessary HT insulation at joints. Removing perished monoplus compound cleaning and re-insulating with HT taps wherever necessary, with and including replacement of worn-out/defective spares like tension springs, torsion springs, nut bolts, washers of suitable size, lingers and de-carbonizing all joints, bus bar, CTs, PTs spout metal parts and making VCB perfect operation in manual and electric mode including all routine and preventive maintenance of breaker under the supervision of authorized dealer /representative and reconnecting the panel/breaker in its original position and testing all as specified and directed. Note: - (i) The rate quoted inclusive of all minor spares etc. (ii) Spares parts required other than mentioned here-in-after shall be deemed to be included in the quoted rate.
Supply only shunt trip coil 220/110 or 30Volts DC
Supply only closing trip coil 220/110 or 30Volts DC
Supply only bus bar insulator 11KV complete all as specified and directed.
Supply only contact system for VD4-630A suitable for SEIMENS/ CROMPTON/ SCHINDER make HT breaker
Supply only Aux switch suitable for SEIMENS/ CROMPTON/ SCHINDER make HT breaker
Supply only spring drum suitable for SEIMENS/ CROMPTON/ SCHINDER make 11KV HT breaker
Supply only spring V4207 suitable for SEIMENS/ CROMPTON/ SCHINDER make 11KV HT breaker
Supply only Roller chain V4208 suitable for SEIMENS/ CROMPTON/ SCHINDER make 11KV breaker
Supply only Tension spring suitable for SEIMENS/CROMPTON/SCHINDER make 11KV HT breaker
SS&F in repair digital multifunction meter LED display, for HT breakers
Supply only motor cut off switch suitable for SEIMENS/ CROMPTON /SCHINDER make 11KV HT breaker
Supply only ‘On Off’ indicator (display) suitable for SEIMENS/ CROMPTON/ SCHINDER make 11KV HT breaker
Supply only panel space heater 80W complete all as specified
S&F in repair Pin Insulator 11KV at 2/4pole 11KV structure unit complete all as specified and directed
S&F in fuse element 20A-50A at 2/4pole 11KV structure unit complete all as specified and directed.
M&L for checking Insulator, lightning arrestor and tightening/replace aluminum jumbler connection complete at 2/4 pole 11KV structure complete all as specified and directed.
Supply only New vacuum interrupter 1200/800/630A 11KV rating suitable for SEIMENS/ CROMPTON/ SCHINDER HT breaker all as directed by Engr-In-Charge
Supply only Mono block for interrupter mounting base 11KV rating suitable for SEIMENS/CROMPTON/SCHINDER.
Supply only travelling mechanism insulator 11 KV suitable all as specified and directed. SEIMENS/CROMPTON/SCHINDER.
Supply only panel spout top and bottom 11KV complete all as specified and directed. SEIMENS/CROMPTON/SCHINDER.
Supply only of Moving Cluster conduct 11KV complete all as specified and directed SEIMENS/CROMPTON/SCHINDER..
S&F in repair LED Indication lamps suitable for HT breakers complete all as specified and directed.
Taking out old unserviceable under ground PVC/XLPE HT cable of any size from trenches/ wall/roof/road/pipe/pole including segregation of serviceable bricks for re-use complete all as specified and as directed.
Excavation in trenches not exc 1.5 Meter wide and not exc 1.5 Meter depth in hard / dense soil for laying of cable, pipes etc and getting out in soft/loose soil all as specified and directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc 25cms of soil complete all as specified and directed.
Removing the surplus excavated material/soil to a distance not exc 50 Meters and depositing, where directed at a level not exceeding 2.5 Meters above the starting point all as specified and directed.
Supply and spread sand for river sand cushioning of cables in trenches all as specified in MES Schedule Part-I and all as directed. Note: Punned thickness only will be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class HV P, type 1 with peak, size 300mm x 180mm x 40mm
Re-laying only old PCC cover for cable protection cover, laid flat and dry in trenches over the cable, perpendicular to the direction of cable complete all as specified and as directed.
Relaying/ re routing of old serviceable under ground PVC / XLPE LT cable any grade and any size in trenches / fixed to wall / pole / roof / laid in floor including necessary connections and thumbing complete all as specified and as directed. Note: Earth work, brick & sand cushioning shall be measured and paid for separately under appropriate item.
S&F new 2 volt dry cell 100Ah battery for DC supply for relay mechanism of VCB and complete wiring upto relay mechanism and taking down existing unserviceable battery all as specified and directed by Engr-in-charge.
M & L Disconnecting LT connections of existing Battery charger 30Volt 25 Amp with control panel at substation and repaired to authorized dealer necessary repair/replacement of major and minor defective parts, wiring including installation in the same location and testing, complete, all as specified and directed. Note: - (i) The rate quoted inclusive of all spares etc.
S & F Battery charger 30Volt 25 Amps including installation in the same location and testing, complete including taking down old unserviceable Battery charger all as specified and directed. Note: - The rate quoted inclusive of all spares etc.
M & L Taking proper shut down and disconnecting the cables from VCB, draw out faulty VCB breakers from panel 1250/ 800/ 630A 13.1KA rating Indoor type make of SEIMENS/ CROMPTON/SCHINDER after removing VCB spout and CT overhauling improving of IR value of hot air oven process and alightnment of mechanism including installation in the same location and testing complete all as specified and directed.
Supplying and toping up new mineral grade transformer oil EHV type confirming to IS-335 to 1983 for filling and for topping up in transformer/Voltage stabilizer duly filtered with filer plant to obtain high dielectric not less 60KV (Gap 2.5mm) complete all as specified and directed by Engineer In charge.
M& L for Purification, filtration and Dehydration of transformer oil of transformer installed at various indoor/outdoor sub station by ultra high vacuum filtration machine with stream line filtration plant at a temp 60 to 70 deg. Celsius and achieving minimum dielectric withstand strength of 60 KV for 1 minute in 2.5 mm gap setting (for used oil) complete all as specified and directed by Engineer-in-Charge. Note: (i) Contractor shall ensure no wastage of transformer oil. (ii) Oil required for topping up the transformer will be measured & paid separately.(iii) Contractor shall be ensure that the conservator tanks are full to its level before starting the dehydration
M&L (in repair) cable jointing kit for 11 KV cable for indoor end termination cold shrink with jointing material and accessories suitable for 3 core XLPE armored aluminum conductor cable of size 120 Sqmm to 185 Sqmm, indoor type all as directed.
M&L (in repair) cable jointing kit for 11 KV cable for indoor end termination Heat shrinkable with jointing material and accessories suitable for 3 core XLPE armored aluminum conductor cable of size 120 Sqmm to 185 Sqmm, indoor type all as directed.,
M&L (in repair) cable jointing kit for 11 KV cable for out door end termination Heat shrinkable with jointing material and accessories suitable for 3 core XLPE armored aluminum conductor cable of size 120 Sqmm to 185 Sqmm, indoor type all as directed.,
M&L (in repair) cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint with jointing material and accessories suitable for 3 core XLPE, armored aluminum conductor of size 120sqmm to 185 Sqmm cable complete all as specified and directed.
S&F in replacement of female contact or fixed contact heavy duty and high conductive metal complete capacity 200A/400 amp, 11 KV of air break gang operated
S&F in replacement of male contact or moving contact heavy duty and high conductive metal complete capacity 200A/400 Amp, 11 KV of air break gang operated switch.
S&F in replacement of Pin insulator HT 11 KV. Make: Jaipuria or equivalent
Material and Labour for preparing surfaces of transformer of capacity up to 500 KVA by rubbing old paint and applying two coats of spray painting with grey deco paint from outside, complete all as specified and as directed. Note. Painting of transformer will be carried out for plinth mounted and pole mounted transformer. Necessary tools and plants shall be arranged by the contractor. Shut down schedule for painting of transformer will be submitted in advance to plan shut down in the station.
Supply and laying HT XLPE insulated, screened PVC bedded, galvanized steel strip or wire armored, electric power cable ( heavy duty ) with aluminum conductor 11000 volt grade, cross sectional area 150 Sqmm, 3 core (earthed) conforming to IS-7098 (Part-I) laid in trenches / under floor / roads / along poles/ducts etc. all as specified and directed
M&L for defect rectification in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse fault location with high frequency distance calculator etc. Excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size up to 240 Sqmm 3 core. Notes: (i) The contractor shall bring the fault locating equipment at site with in 02 hours of instructions received from Engineer -in- charge and he shall ensure that the fault is rectified with in 24 hours of receipt of intimation from Engineer-in-charge failing which recovery of Rs. 500.00 per hour shall be recovered from the contractors dues with effect from the time immediately after the expiry of 24 hours duration. (ii) For the purpose of payment one unit of “each job” shall comprise of detection of faults in a particular stretch of cable which are identified in that particular stretch , irrespective of number of defects / faults in that particular stretch which are detected during fault detection and the contractors unit rate quoted shall be deemed to include for the same and all such defects / faults which are detected in that particular stretch shall be considered as one unit. (iii) Joints, jointing materials and cable required shall be measured and paid for separately. (iv) The payment is not applicable for error fault finding location.
Taking proper shut down permission in writing and disconnecting the HT & LT connections of existing Indoor/Outdoor type transformer of capacity upto 1000 KVA mounted on 2/4 pole structure/plinth and transport to authorized workshop for repair and back to site after necessary repair/replacement of defective parts including installation in the same location and testing, complete, all as specified and directed. (i) Placing /removing standby transformer in the place of defective transformer under repair including loading/unloading, shifting including transportation and make the system/line functional will be the responsibility of the contractor, LT cables, switch gear and other connected items for temporary connection will be provided by the contractor. Contractor’s quoted rates shall be inclusive of all these factors.
Note for Item No. 48: (a) The quoted rate quoted for the item includes the following :- (i) Arrangement of manpower, tools and plants and Recovery vehicle for transportation and shifting of transformer to work shop and back. (ii) Toping up of transformer oil, replacement of transformer oil as required basis under intimation to the department. (Transformer oil will be measured and paid separately). (iii) Cutting/chipping of RCC/PCC plastering of foundation/platform and minor grill work/welding work. (iv) Winding material, labour and other items shall be measured and paid separately under respective items. (v) Contractor shall inform the department for inspection on the same day on receipt of repaired transformer from the workshop. (vi) Transformer shall be tested in presence of Engineer-in-Charge at workshop and after installation at site and test result shall be kept in record duly signed by all concerned. One day prior intimation shall be given to the Engr-in-Charge for testing. (Testing record will be prepared by contractor and signed by Engr-in-Charge). (vii) Any loss/damage occurred to transformer in all respect during transportation/ installation shall be made good by the contractor at no cost to department.
S&F in replacement of LT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer 100 to 1000 KVA
S&F in replacement of LT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer 100 to 1000 KVA
S&F in replacement of HT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer 100 to 1000 KVA
S&F in replacement of HT bush assembly brass complete with double check nuts, washers and oil seal all accessories with bushing insulators for transformer 100 to 1000KVA
Taking out the unserviceable breather assembly complete form indoor/outdoor type transformer capacity up to 1000 KVA and supply and fixing the new breather assembly complete filled with fresh blue silica gel including connecting with proper rubberized gasket complete al as specified and directed
S&F new silica gel complete all as directed.
M&L for inspecting electronic relay (over current relay and earth fault relay) from 11KV VCB and calibrating the relay with the help of secondary injection kit and proper setting of relays and refixing back in existing position testing of proper tripping / functioning system and calibration report complete all as specified and directed.
S&F ON-Load change over switch manual type without sheet metal enclosure 630 Amps rating TPN, 415 V complete all as specified and directed. Make: L & T /GE POWER/ ABB/ SIEMENS /STANDARD/ HAVELLS
Supply and laying/spreading 40 mm graded gravel(stone aggregate) 40mmthick, bedding thickness of 100 to 150mm in any position at electrical 2/4 pole structure all as directed.
BKR Enterprises
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .