Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹53.5 LAccepted-AOC | 1 | Accepted-AOC Bidder is L1 | |
| 2 | 2₹59.8 L+₹5.4 L (9.84%)Rejected-AOC | 2 | Rejected-AOC Bidder is not L1 |
Tender Value
₹52.2 L
EMD Value
₹1.0 L
Closing Date
6 Jan 2024, 6:00 pmClosed
CWE Jalandhar Cantt
HQ CWE Nalwa Road Jalandhar Cantt PIN-144005
Please refer tender documents
2023_MES_631432_1
8323/48/E8
Open Tender
Civil Works
Item Rate
273 days
Jalandhar Cantt
Class C Category a(i) for contractors enlisted with MES
8 documents required · 8 mandatory
₹1,000
AGE (I) Suranussi
₹1.0 L
Yes
13 May 2024
6 Dec 2023
13 Jan 2024
6 Dec 2023
6 Jan 2024
25 Dec 2023
Amount
Demolition of brick work built in cement mortar including all quoins arches etc.
Demolition of cement conc in ground floor and pavings not exceeding 15 cm thick above or below ground level.
Demolition of reinforced cement Concrete of any description and in any position not otherwise specifically provided for.
Taking down cement or cement lime plaster of any description on brick or stone walls, etc incl raking out joints hacking for keys srubbing down with water etc complete all as specified and as directed.
Taking down chowkats or frames with Shutters ( without taking off the shutter from the frame ) of area n.exc 1.50 Sqm each and removing from site complete all as specified and as directed.
M&L for 35 mm thick 2nd clas hard wood, , factory made Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated as specified in SSR Part I section 8 clause 8.2(a) complete all as specified and as directed.
M & L GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists in repairs in patches n exc 5 sq. m each, including taking down old and jointing new to old as required (patches exc 5 sq.m each to be measured as new work) , etc. in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste.
Dismantling structural steel work including doors, gates but excluding framed truss etc.
M&L brick work, with sub class 'B' bricks built in cement mortar 1:6 straight or curved on plan exc 6mtr mean radius complete all as specified and as directed.
Ditto all as per item No 09 above but except bricks.
M&L 15mm thick cement plastering in cement mortar (1:6) on other than fair faces of brick work or concrete surfaces , finished even & smooth without using extra cement complete all as specified.(Bldg ht upto 10 m).
M&L for 15 mm thick cement plastering in cement mortar (1:4) on fair faces of brick work or concrete surfaces with using water proofing compound @ 3% by weight of cement, finished even & smooth without using extra cement complete all as specified. WPC to be paid seperately.(Bldg ht upto 10 m).
M&L for 5 mm th rendering in cement mortar in 1:3 on RCC surfaces with using Super Plastisizers, finished even & smooth without using extra cement complete all as specified. Note : Super Plastisizer to be measured and paid seperately).(Bldg ht upto 10 m).
Supply only Liquid water proofing compound complete all as specified and as directed by engineer-in-charge.
S&F Framed work as in sliding doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting and door hold fast or other covering to Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening conforming to GdeFe 290(Gde E-165) including all accessories such as holdfast,sliding door bolt etc complete all as specified.
S&F for Mild steel sheet of 1.60 mm thick, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including all accessories ,and bending or turning up, mitred angles, etc. as required.
S&F welded steel wire fabric fixed complete to wood or steel members exc 4 kg/Sqm complete all as specified at
Hacking old broken glass of any size and desription from wooden frames.
S&F in repair 3mm th sheet glass ordinary quality glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed by Engineer-in Charge.
Demolition of cement Concrete of any description and in any position not otherwise specifically provided for.
Priming surfaces and applying normal treatment (for moderate conditions) using glass fiber based bitumen felt, grade 2 complete all as specified.
Applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 kg per sq.m including cleaning surfaces (Bldg ht upto 10 m).
APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non woven fabric (wt. not less than 150 gms/sqm) laid on primed surface by torch application with two coats of bitumen based aluminium paint complete all as specified (Bldg ht upto 10 m).
M&L for 75mm average consolidated thickness pcc 1:2:4 type B1 with using 20mm graded stone aggregate as in padding on flat roofs etc all as specified and directed.
M&L for three coats of white wash on newly plastered surface of ceiling incl preparation of surface complete all as specified incl preparation of surfaces complete all as specified (Bldg ht upto 10 m).
M&L preparing surfaces new of walls and applying two caots of cement base paint over a coat of primer complete all as specified incl preparation of surfaces.(Bldg ht upto 10 m).
M&L preparing new surfaces of walls ,applying two coats of white wash for complete all as specified and directed by Engr-in-Charge (Bldg ht upto 10 m).
M&L preparing old surfaces of walls , complete removal of existing treatment and applying two coats of white wash for complete all as specified and directed by Engr-in-Charge.
M&L for preparing old surfaces of walls, complete removal of existing treatment and applying two caots of cement base paint in camouflage pattern for complete all as specified and directed by Engr-in-Charge.(Bldg ht upto 10 m).
M&L for two coats of synthetic enamel paint on new steel surface over 10cm width or girth over a coat red oxide primer.
Ditto all as per item 30 above but one coat on old treated surface complete all as specified and directed by Engr-in-Charge.
M/L Providing, cement concrete type B0 1:2:4 (using 12.5 mm aggregate), as in roof kerbs or mud stops, rounded or chamfered on edges parapets copings, bed plates, etc.
M&L for 75 mm th PCC 1:3:6 type C2 as in plinth protection with using 40mm graded stone aggregate etc all as specified.
Cutting grooves of size 75mm wide and 65mm deep in brick parapet wall for inserting APP membrane and making good the disturbed portion in CM (1:3).
M & L for preparation of old rusted reinforcement by brooming, scrubbing, cleaning with and applying NITOZINC Primer on affected area grouting with pressure jet machine ( NITOZINC Primer to be paid separately) complete all as specifed and directed by Engr-in-Charge.
M&L for 50 mm th PCC 1:2:4 type B1 as in flooring over well rammed and Brass dividing strip laid in bays/panels as in Flooring including finishing the surface even and smooth without using extra cement.
Supply only NITO ZINC PRIMER (Make : FORSOC) to be applied on rusted reinforcement @ 08 Sqm/litre.
Supply only NITO BOND EP, epoxy bonding agent (Make : FORSOC) to be applied on concrete surfaces @ 04 Sqm/litre.
M & L for reinforced cement concrete type B-0, 1:2:4 (12.5 mm graded aggregate) in door and windows frames, any size, single or double rebated, including arrangement for fixing of hinges and fixtures as required.
M & L for Cutting opening in cement concrete walls with or without reinforcement (any descript-ion) for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc.
M&L Removing building materials etc. to a distance of 100m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed.
S& F expanded metal n.exc. 4.0 kg per sqm cut to length, bent to shape reqd and lyng with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples complete all as specified and directed by Engineer-in-charge.
M & L for Reinforced cement concrete (nominal mix) type B-0 1:2:4 using 12.5 mm graded aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc at a height of 10 mtrs from GL using NITO BOND EP as per manufacturer's instructions. (Note : NITO BOND EP will be measured and paid separately).
M & L TMT bars 8 mm dia and over dia cut to length bent to shape required including cranking, bending and binding with and including ms wire (annealed) n. less than 0.9mm dia or securing with clips incl tack welding all as specified.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified.
M & L Machine pressed precast conc. interlocking paver block any shape and size confirming to IS 15658-2006 of 80 mm thickness M-40 grade with grey cement and with pigment complete all as specified and directed by Engr - in - Charge.
M & L 100 mm thick Cement concrete type D-2, 1:4:8 ( (40mm graded aggregate) as in sub Bases complete all as specified and directed by Engr - in - Charge.
M&L 25 mm thick Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in–Charge.
M & L Cement concrete 1:2:4 type B–1 using 20mm graded stone aggregates in copings,, including weathering, slightly rounded or chamfered angles and throating, as directed all as specified and directed by Engineer - in - Charge .
Taking down carefully copper/aluminium point wiring (light/fan/Bell/ socket or power point) complete inclusive of all fittings, removing materials from site and making good disturbed surfaces of floors /walls/ceiling etc all as directed.
Materials and labour for point wiring with 2.50 Sq.mm. PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volts grade, single core, laid in and including steel conduit not less than 20mm dia with all assessories such as junction box, MS coupling, unions bench, reducers, elbow, sealing conduit etc on wall surfaces/ roof and, including 1.50 Sq.mm PVC insulated, unsheathed multistranded copper conductor FRLS cable(green colour) 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for three light point controlled by one rotary switch/ MCB SP complete all as specified and directed.
Materials and labour for power point wiring with 4.0 Sq.mm. PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volts grade, single core, laid in and including steel conduit not less than 20mm dia with all assessories such as junction box, MS coupling, unions bench, reducers, elbow, sealing conduit etc on wall surfaces/ roof and including including 2.50 Sq.mm PVC insulated, unsheathed multistranded copper conductor FRLS cable(green colour) 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for one 3/5Pin 6/16 Amps socket outlet independent board complete all as specified and directed.
Supply and fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
Supply & Fix Flame proof switch & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth.
Supply and fixing junction box 125 mm dia three way flame proof all as specified and directed.
Supply and fixing MCB SPN, 240 Volts, 40 Amp capacity, 10 KA, 'C' curve complete all as specified and directed by Engr-in-Charge.
Supply and fixing MCB SP, 240 Volts, 6 to 40 Amp capacity, 10 KA, 'C' curve complete all as specified and directed by Engr-in-Charge.
Supply and fixing MCB TPN, 415 Volt, 63 Amp capacity, 10 KA, 'C' curve complete all as specified and directed by Engr-in-Charge.
Supply and fixing MCB distribution board TPN, 4 way, 415 Volts, vertical double door with 200 Amps rated bus bar, neutral bar with shrouds, earth bar, IP-43 DB's, made out of sheet steel enclosure, recessed type, factory made powder coated, suitable for housing MCB's including blanking plate complete all as specified and directed. Make : Legrand/Schneider/Seimens. Note : MCB DB and MCB SP/SPN will be of same make.
Supply and fixing in replacement of aluminium flame proof bulk head fitting 12 Watt , CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED lamp light fixtures , holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Supply and fixing cool white LED flame proof flood light B15, (80-150 W) , CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection with die cast aluminum hosing with heat resistant toughened glass with LED lamp light fixtures , holders, connector etc. Complete with all accessories prewired and including connecting up with three core flexible copper conductor cable with suitable size.
Material and Labour for submain wiring with two runs of single 4 sqmm FRLS PVC insulated unsheathed multistranded 1100 vols grade with copper conductor drawn through and including in steel conduit medium grade ISI marked and its accessories including one run of single core 4 sqmm FRLS PVC insulated unsheated multistranded 1100 volts grade with copper conductor cable as earth contuinity conductor along with the wiring and connected from DB to DB/ main board completeall as specified and as directed.
Taking down existing Crane of cap 5 Ton from its original position including Railing/Girder/ I section of any length/size incl cutting/welding and kept/placed safe and custody, if any defect of cane occurred, then Transporting to work shop for repair/ replacement of any tpe of parts and Transporting Crane from work shop to site then Properly reinstall, the same as its original position, proper aligment, including two coat of painting after scrapping with eamery paper and serviceing the crane after completion of B/R work nd testing and commissioning all as directed and specified. Note :- (a) Contractor should visit the site before quote the rate. (b) The work to be carried out by OEM only.)
Material and Labour for earthing complete with copper earth plate electrode 600mm x 600mm x 3.15 mm thick buried directly in ground earth pit not less than 2.25 mtr below normal GL with the top edge of the plate not less then 1.5 mtr below the normal GL connected to 20X3mm copper strip as earth lead by means of bolts, nuts, check nuts and washer of brass and protected by 40 mm GI pipe (light grade) and watering pipe 20mm bore GI pipe (light grade) including GI wire meshed funnel and chamber PCC (1:4:8) type D2 using 40mm grade stone aggregate, coping shall be (1:3:6) type CI using 20mm stone aggregate with RCC 1:2:4 type B1 (using 20mm graded stone aggregate) pit cover re-inforced with 8mm dia at 80mm c/c both way in lieu of CI pit cover with angle iron frame, including excavation and earth work in any type of soil and removal of surplus soil of earth complete all as shown in electrical plate of SSR Part I and as specified including charcoal dust, common salt complete and earth lead connected to earthing test point all as specified and testing of earthing on completion. Note :- The unit rate includes for protection pipe and copper strip 20X3mm from top of earth plate up to 7.5 meter above ground level.
Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or were armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 35 Sqmm 3.5 core .
Supply and fix GI tubing light grade for encasing cables for protection, laid under plinth/flooris/roads/path/culverts or fixed on walls/ on poles by means of MS clamps with necessary bolts, nuts and washers 40mm bore all as specified and directed.
Excavaton over areas in soft/loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, poles/stays and struts etc and getting out including trimming sides and forming bottom surface all as specified and directed at site.
Returning, filling in including spreading, leveling, watering and well ramming excavated hard/soft inlayers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays, struts have been erected and tested, all as specified and directed.
Removing excavated surplus soil (Soft/loose soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified and directed.
Material and lobour for clean dry sand laid in trenches/ ducts for cushioning to cable complete all as specified.
Supply and fix common burnt clay building bricks Sub class B designation 75 with width equal to lenth brick and depth vertical all as in cable protection
Gurjit const co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .