Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC 103 1A RAJA DINENDRA STREET KOLKATA 700006 | KOLKATA | KOLKATA | WEST BENGAL | 700006 | L1 | Accepted-AOC Accept | |
| 2 | L2₹4.4 L+₹6,643 (1.55%)Rejected-Finance MOSAT HARIPUR RD VILL P O HARIPUR DIST HOOGHLY PIN 712701 | HARIPUR | HOOGHLY | WEST BENGAL | 712701 | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹4.4 L+₹7,000 (1.63%)Rejected-Finance BALTIKURI INDUSTRIAL ESTATE PLOT NO A 01 DASNAGAR HOWRAH 711113 | HOWRAH | HOWRAH | WEST BENGAL | 711113 | L3 | Rejected-Finance 3rd Lowest | |
| 4 | L4₹4.7 L+₹40,800 (9.51%)Rejected-Finance | L4 | Rejected-Finance 4th Lowest | |
| 5 | L5₹4.7 L+₹45,880 (10.7%)Rejected-Finance 90 E BECHARAM CHATTERJEE ROAD KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L5 | Rejected-Finance 5th Lowest |
| Sl No | Description | Qty | Unit | NEW INDIA ELECTRICAL AND ENGINEERING WORKS L6 | S.R. REFRIGERATION AND APPLIANCES L1 | NATIONAL AIRCON L3 | UNIVERSAL SALES L4 | SIMPSON AND FERRIS PVT LTD L5 | GHANASHYAM ELECTRIC STORES L2 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply & delivery of Hi- wall Split Air conditioner (Inverter type) having following specification:
Minimum Cooling Capacity(Kcal/Hr)- 4500 K.Cal/hr Or 5000W
ISEER Rating - 3.8-4.39 /2022-2023 as per BEE/BIS
IS Compliance- IS 1391
Refrigerant- R410A/R32
Compressor - Rotary/ Scroll
Evaporator & Condenser Coil: Copper LCD Remote and All other accessories
operating outdoor Temperature - 50°C
PCB must be in Metallic Enclouse to avoid internal fire hazard
Power supply - 240 V,50Hz(+ Tolerrance as per applicable standard)
Make:- O-General/ Mitsubishi Electric/ Daikin/ Hitachi | 7 | Each | 56,800 ₹3,97,600 | 55,000 ₹3,85,000 | 55,000 ₹3,85,000 | 57,500 ₹4,02,500 | 48,950 ₹3,42,650 | 44,009 ₹3,08,063 Lowest |
| 2.00 | Installation Testing & commissioning of the above Said Split Acs incl. Supply & fixing required Angle iron structure on wall for placing outdoor unit and mending Good the damages as per direction of EIC | 7 | Job | 2,500 ₹17,500 | 2,000 ₹14,000 Lowest | 3,000 ₹21,000 | 2,800 ₹19,600 | 3,000 ₹21,000 | 2,700 ₹18,900 |
| 3.00 | S & Installation of Extra Add-on Items HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle, screws, insulation tape, fasner etc for above AC machines as per direction of EIC. | 70 | Mtr | 1,250 ₹87,500 | 150 ₹10,500 Lowest | 150 ₹10,500 Lowest | 280 ₹19,600 | 1,250 ₹87,500 | 1,260 ₹88,200 |
| 4.00 | Supply & Laying 1.1KV grade 3 core 4 sqmm flexible copper cable with screw, saddle drill machine nut bolt etc all necy. items needed for connection.(from starter to AC outdoor connection)(Make: Havells/KEI/Polycab/Fenolex as per approved by EIC) | 70 | Mtr | 165 ₹11,550 | 150 ₹10,500 Lowest | 150 ₹10,500 Lowest | 180 ₹12,600 | 164 ₹11,480 | 164 ₹11,480 |
| 5.00 | Supply & Laying 20mm hard PVC pipe(heavy type) for water discharge(Make: supreme ) | 130 | Mtr | 70 ₹9,100 Lowest | 70 ₹9,100 Lowest | 70 ₹9,100 Lowest | 120 ₹15,600 | 95 ₹12,350 | 70 ₹9,100 Lowest |
Tender Value
Refer Docs
EMD Value
₹8,859
Closing Date
4 Jun 2025, 12:00 pmClosed
AEWBESDPWD
Block I First Floor Writers Buildings Kolkata 700001
Renovation and Remodeling office chamber of Chief Engineer south Zone and other Office Chambers at Block II 1st floor of Writers Building SITC of Air-conditioner Machines.
2025_WBPWD_849264_1
WBPWD/AE/WBESD/eNIQ-08 of 2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Writers Buildings
Please refer Tender documents.
6 documents required · 6 mandatory
₹8,859
11 Sept 2026
20 May 2025
9 Jun 2025
20 May 2025
4 Jun 2025
24 May 2025
Amount
Supply & delivery of Hi- wall Split Air conditioner (Inverter type) having following specification: Minimum Cooling Capacity(Kcal/Hr)- 4500 K.Cal/hr Or 5000W ISEER Rating - 3.8-4.39 /2022-2023 as per BEE/BIS IS Compliance- IS 1391 Refrigerant- R410A/R32 Compressor - Rotary/ Scroll Evaporator & Condenser Coil: Copper LCD Remote and All other accessories operating outdoor Temperature - 50°C PCB must be in Metallic Enclouse to avoid internal fire hazard Power supply - 240 V,50Hz(+ Tolerrance as per applicable standard) Make:- O-General/ Mitsubishi Electric/ Daikin/ Hitachi
Installation Testing & commissioning of the above Said Split Acs incl. Supply & fixing required Angle iron structure on wall for placing outdoor unit and mending Good the damages as per direction of EIC
S & Installation of Extra Add-on Items HVAC grade 5/8"(for suction) & 1/4"(for discharge) copper refrigerant pipe with 9mm thick nitrile rubber insulation including shaddle, screws, insulation tape, fasner etc for above AC machines as per direction of EIC.
Supply & Laying 1.1KV grade 3 core 4 sqmm flexible copper cable with screw, saddle drill machine nut bolt etc all necy. items needed for connection.(from starter to AC outdoor connection)(Make: Havells/KEI/Polycab/Fenolex as per approved by EIC)
Supply & Laying 20mm hard PVC pipe(heavy type) for water discharge(Make: supreme )
GHANASHYAM ELECTRIC STORES (BID ID -6494819)
NATIONAL AIRCON (BID ID -6486046)
UNIVERSAL SALES (BID ID -6486784)
SIMPSON AND FERRIS PVT LTD (BID ID -6490605)
NEW INDIA ELECTRICAL AND ENGINEERING WORKS (BID ID -6483270)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .