| 1 | L1₹44.5 LAccepted-AOC | L1 | Accepted-AOC Accepting being lowest | |
| 2 | L2₹46.8 L+₹80,590 (1.75%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
18 Feb 2023, 6:00 pmClosed
Maj Pramod Kumar Tripathi
Military Engineer Services, Garrison Engineer (South) Ahmednagar - 414002
REPAIR/MAINT OF PUMPING MACHINERY, WATER SUPPLY INSTALLATION AND CLEANING/PAINTING OF OH RESERVOIR, SEMI/UNDERGROUND SUMPS AT AC DEPOT, BHINGAR, DHOBIGHAT, NEW KLP AND ACC AND S AREA PUMP HOUSES UNDER GE (S) AHMEDNAGAR
2023_MES_576396_1
8949/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Ahmednagar
Class D Cat a (ii)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹1 L
Yes
10 Mar 2023
21 Jan 2023
20 Feb 2023
21 Jan 2023
18 Feb 2023
4 Feb 2023
21 Jan 2023 - 28 Jan 2023
Amount
Repair/maintenance/servicing and checking thoroughly, defective centrifugal pump set of capacity 120 HP by dismantling of pump set at site and checking, inspection and replacement of unserviceable spares as required or as directed by Engr-in-Charge. Note :- (a) Spares shall be measured and paid separately under relevant items as 'S&F in repairs'. (b) The work involves proper alignment after repairing, testing, recommissioning the pump set to the entire satisfaction of Engr-in-Charge. (c) Job should be carried out by the authorised persons.
All as per serial item No 1 but pump set of capacity 100/90 HP.
All as per serial item No 1 but pump set of capacity 75 HP.
All as per serial item No 1 but pump set of capacity 60 HP.
All as per serial item No 1 but pump set of capacity 30 HP.
All as per serial item No 1 but pump set of capacity 25 HP.
S&F in repairs, air release valve, making hole on pump for 30 HP to120 HP pump set
S&F in repairs, Gland plate nuts and bolts both side of pump 04 nos for 25 HP to 120 HP pump
S&F in repairs, water retaining (Deflector) Ring DE/NDE for 120 HP pump set
S&F in repairs, Spilt Linter Ring, CI, DE/NDE, for 120 HP pump set
S&F in repairs, Cartridge for bearing, DE/NDE for 120 HP pump set
S&F in repairs, Shaft Sleeve, CI, DE/NDE for 120 HP pump set
S&F in repairs, Stuffing box bush (Throat), CI, DE/NDE for 120 HP pump set
S&F in repairs, Gland plate with gland packing, CI, for 120 HP pump set
S&F in repairs, Set of gasket, for 120 HP pump set
S&F in repairs, Set of 'O' ring, for 120 HP pump set
S&F in repairs, Wear ring, CI, for 120 HP pump set
S&F in repairs, Impeller CI stage -I for 100/90 HP Pump set
S&F in repairs, Impeller CI stage -II for 100/90 HP Pump set
S&F in repairs, Pump shaft C-40 including sleeves for 100/90 HP Pump set
S&F in repairs, Water retaining (Deflector) Ring DE/NDE for 100/90 HP Pump set
S&F in repairs, Spilt Linter Ring CI DE/NDE for 100/90 HP Pump set
S&F in repairs, Cartridge for bearing DE/NDE for 100/90 HP Pump set
S&F in repairs, Shaft Sleeve CI DE/NDE for 100/90 HP Pump set
S&F in repairs, Stuffing box bush (Throat) CI DE/NDE for 100/90 HP Pump set
S&F in repairs, Gland plate with gland packing CI for 100/90 HP Pump set
S&F in repairs, Set of gasket for 100/90 HP Pump set
S&F in repairs, Set of 'O' ring for 100/90 HP Pump set
S&F in repairs, Wear ring CI for 100/90 HP Pump set
S&F in repairs, Impeller CI stage -I for 75 HP Pump set
S&F in repairs, Impeller CI stage -II for 75 HP Pump set
S&F in repairs, Pump shaft including sleeves for 75 HP Pump set
S&F in repairs, Water retaining (Deflector) Ring DE/NDE for 75 HP Pump set
S&F in repairs, Linter Ring CI DE/NDE for 75 HP Pump set
S&F in repairs, Cartridge for bearing DE/NDE for 75 HP Pump set
S&F in repairs, Shaft Sleeve CI DE/NDE for 75 HP Pump set
S&F in repairs, Stuffing box bush (Throat) CI DE/NDE for 75 HP Pump set
S&F in repairs, Gland plate with gland packing CI for 75 HP Pump set
S&F in repairs, Set of gasket for 75 HP Pump set
S&F in repairs, Set of 'O' ring for 75 HP Pump set
S&F in repairs, Wear ring CI for 75 HP Pump set
S&F in repairs, Impeller CI stage -I for 60 HP Pump set
S&F in repairs, Impeller CI stage -II for 60 HP Pump set
S&F in repairs, Pump shaft including sleeves for 60 HP Pump set
S&F in repairs, Water retaining (Deflector) Ring DE/NDE for 60 HP Pump set
S&F in repairs, Linter Ring CI DE/NDE for 60 HP Pump set
S&F in repairs, Cartridge for bearing DE/NDE for 60 HP Pump set
S&F in repairs, Shaft Sleeve CI DE/NDE for 60 HP Pump set
S&F in repairs, Stuffing box bush (Throat) CI DE/NDE for 60 HP Pump set
S&F in repairs, Gland plate with gland packing CI for 60 HP Pump set
S&F in repairs, Set of gasket for 60 HP Pump set
S&F in repairs, Set of 'O' ring for 60 HP Pump set
S&F in repairs, Wear ring CI for 60 HP Pump set
S&F in repairs, Impeller CI for 30 HP Pump set
S&F in repairs, Pump shaft including sleeves for 30 HP Pump set
S&F in repairs, Water retaining (Deflector) Ring DE/NDE for 30 HP Pump set
S&F in repairs, Linter Ring CI DE/NDE for 30 HP Pump set
S&F in repairs, Cartridge for bearing DE/NDE for 30 HP Pump set
S&F in repairs, Shaft Sleeve CI DE/NDE for 30 HP Pump set
S&F in repairs, Stuffing box bush (Throat) CI DE/NDE for 30 HP Pump set
S&F in repairs, Gland plate with gland packing CI for 30 HP Pump set
S&F in repairs, Set of gasket for 30 HP Pump set
S&F in repairs, Set of 'O' ring for 30 HP Pump set
S&F in repairs, Wear ring CI for 30 HP Pump set
S&F in repairs, Impeller CI for 25 HP Pump set
S&F in repairs, Pump shaft including sleeves for 25 HP Pump set
S&F in repairs, Water retaining (Deflector) Ring DE/NDE for 25 HP Pump set
S&F in repairs, Linter Ring CI DE/NDE for 25 HP Pump set
S&F in repairs, Cartridge for bearing DE/NDE for 25 HP Pump set
S&F in repairs, Shaft Sleeve CI DE/NDE for 25 HP Pump set
S&F in repairs, Stuffing box bush (Throat) CI DE/NDE for 25 HP Pump set
S&F in repairs, Gland plate with gland packing CI for 25 HP Pump set
S&F in repairs, Set of gasket for 25 HP Pump set
S&F in repairs, Set of 'O' ring for 25 HP Pump set
S&F in repairs, Wear ring CI for 25 HP Pump set
Dismantling and taking down unserviceable electric motor of 120 Hp capacity of Pump set from foundation and transportation to workshop for repairing, opening and rewinding with new super enamelled copper insulated winding wire as per existing gauge of copper wire, winding with insulating material, varnishing, heating etc and reassembling, transporting back to site of work and installing on existing foundation including proper alignment and testing complete all as specified and directed by Engr - in -charge. Note :- All disturbed surface shall be made good to match the sourounding
All as per serial item No 76 but electric motor of 100/90 Hp capacity of Pump set.
All as per serial item No 76 but electric motor of 75 Hp capacity of Pump set.
All as per serial item No 76 but electric motor of 60 Hp capacity of Pump set.
All as per serial item No 76 but electric motor of 30 Hp capacity of Pump set.
All as per serial item No 76 but electric motor of 25 Hp capacity of Pump set.
S&F ball bearing suitable for 120 HP capacity pump and motor including taking out old unserviceable bearing all as specified and as directed
S&F ball bearing suitable for 100/90 HP capacity pump and motor including taking out old unserviceable bearing all as specified and as directed
S&F ball bearing suitable for 75 HP capacity pump and motor including taking out old unserviceable bearing all as specified and as directed
S&F ball bearing suitable for 60 HP capacity pump and motor including taking out old unserviceable bearing all as specified and as directed
S&F ball bearing suitable for 30 HP capacity pump and motor including taking out old unserviceable bearing all as specified and as directed
S&F ball bearing suitable for 25 HP capacity pump and motor including taking out old unserviceable bearing all as specified and as directed
S&F in repairs, coupling bushes with studs of existing type and size suitable for 25 HP to 120 HP Pump set all as specified and as directed.
S&F in repairs, coupling star bush of existing type and size suitable for 25HP to 120 HP Pump set all as specified and as directed.
S&F in repairs, love-joy / flexible type coupling, made out of MS, complete suitable for 25 HP to120HP pump Set, including rubber star bush/rubber bush with nut bolts, metal filling existing Shaft of motor/ pump and re-grinding, making key slot etc and testing with zero level alignment complete all as specified and as directed.
M&L for repairs of foundation of motor pump set of 100/ 90/ 75/ 60/ 30/ 25 HP by removing and taking out pump motor from foundation by unscrewing the nuts bolts and keeping away, cutting, welding and machining with flat iron or channel of 50 x 6 mm flat iron and channel MC 75 to MC 150 size as required for strengthing the foundation plate, cutting and replacing / shifting and welding at proper places on motor foundation, replacement of foundation nut bolts, washers, with accurate re-alignment of motor with pump to avoid vibration and smooth running of pump on full load, testing and commissioning complete all as directed. Note;- The Quoted rate shall be deemed to be inclusive of all civil works including PCC 1:2:4, type B2 in foundation and grouting work as per site requirement.
S&F in repairs, pressure gauge (complete set etc. GI bend pipe, nipples, operating switch / valve) of capacity 0-100 kg as per sample suitable for 25 to 100 HP pump set complete all as specified and as directed. Make :- NAVA Tech or equivalent as approved by GE.
S&F in repairs, single phase preventor, suitable for 100/90/75/60/30/25 HP Pump set starter, 415/440 Volt, 50 Hz all as specified and as directed.
S&F in repairs, ML6/ML4/ML2 starter Timer, suitable/existing capacity for 100/90/75/60/30/25 HP Pump set starter, 415/440 Volt, 50 Hz all as specified and as directed.
S&F in repairs, 3 Pole power contactors, TYPE -MNX -95 conforming to IS/IEC 60947-4-1and IEC 6947-1 Amp rating 95 Amps (MNX95) along with Add on TOP2 NO+ 2 NC or Add on side fixed in existing FASD starter complete all as specified and as directed. Make :- L&T Cat No.CS94136 or as approved from list of makes specified.
S&F in repairs, 3 Pole power contactors, TYPE -MNX -70 conforming to IS/IEC 60947-4-1and IEC 6947-1 Amp rating 70 Amps (MNX70) fixed in existing FASD starter complete all as specified and as directed. Make :- L&T Cat No.CS97076 or as approved from list of makes specified.
S&F in repairs, Spare contact kit and spare coil as per L&T Cat No SS-95311 and SS91258 or equivalent in Siemens/Crompton suitable for ML-4 starter complete all as specified and directed.,
S&F in repairs, Spare contact kit and spare coil as per L&T Cat No SS-95313 and SS91258 or equivalent in Siemens/Crompton suitable for ML-6 starter complete all as specified and directed.,
Taking out old unserviceable 3 Pole Power contactor Type ML-2 TP from panel board and supply and fix power contactor ML-2 TP 32 Amps capacity suitable for operation on 415 Volts 50 Hz AC supply complete all as specified and as directed.Make :- L & T Cat No. SS90701 or as approved from list of makes specified.
Taking out old unserviceable 3 Pole Power contactor Type ML-3 TP from panel board and supply and fix power contactor ML-3 TP 40 Amps capacity suitable for operation on 415 Volts 50 Hz AC supply complete all as specified and as directed.Make :- L & T Cat No. SS90721 or as approved from list of makes specified.
Taking out old unserviceable 3 Pole Power contactor Type ML-4 TP from panel board and supply and fix power contactor ML-4 TP 70 Amps capacity suitable for operation on 415 Volts 50 Hz AC supply complete all as specified and as directed.Make :- L & T Cat No. SS90910 or as approved from list of makes specified.
Taking out old unserviceable 3 Pole Power contactor Type ML-6 TP from panel board and supply and fix power contactor ML-6 TP 110 Amps capacity suitable for operation on 415 Volts 50 Hz AC supply complete all as specified and as directed.Make :- L & T Cat No. SS90921 or as approved from list of makes specified.
S&F in repairs, Spare contact Kit TYPE -ML 2 fixed in existing FASD starter complete all as specified and as directed. Make :- L&T Cat No.SS95307 or as approved from list of makes specified.
S&F in repairs, Spare contact Kit TYPE -ML 4 fixed in existing FASD starter complete all as specified and as directed. Make :- L&T Cat No.SS95311 or as approved from list of makes specified.
S&F in repairs, Spare contact Kit TYPE -ML 6 fixed in existing FASD starter complete all as specified and as directed. Make :- L&T Cat No.SS95313 or as approved from list of makes specified.
S&F in repairs, Spare coil TYPE -ML 2 fixed in existing FASD starter complete all as specified and as directed. Make :- L&T Cat No.SS95307 or as approved from list of makes specified.
S&F in repairs, Spare coil TYPE -ML 4 fixed in existing FASD starter complete all as specified and as directed. Make :- L&T Cat No.SS95311 or as approved from list of makes specified.
S&F in repairs, Spare coil TYPE -ML 6 fixed in existing FASD starter complete all as specified and as directed. Make :- L&T Cat No.SS95313 or as approved from list of makes specified.
S&F in repairs, Thermal Overload Relays TYPE -ML 2/3 fixed in existing FASD starter complete all as specified and as directed. Make :- L&T Cat No.SS91859OOEO or as approved from list of makes specified.
S&F in repairs, On load change over switch 415 Volts in sheet metal enclosures, three phase, four pole, 400 Amps capacity, all as specified and as directed.
S&F in repairs, On load change over switch 415 Volts in sheet metal enclosures, three phase, four pole, 200 Amps capacity, all as specified and as directed.
Repair / Servicing to voltage stabilizers, 3 phase, 4 wire system, 75 to 300 KVA at site by opening carefully from top, taking out coils / connections, cleanig coils, checking defective joints / soldering / jointing, re-assembling and testing on full load and making fully servicable including M&L for spray painting with supper enamelled paint of approved colour complete all as specified and as directed.
Topping up / replacement of insulating oil of stabilizer chamber with new insulating / transformer oil upto the required level in any type and capacity of the voltage stabilizer complete all as directed by Engr-in-Charge. Note : Insulating / transforemer oil brought by the contractor at site must be in seal packed in drum having ISI mark as per IS-335 / 1983.
Repair / Servicing to ACB 3 phase, TP 415 V 400/600 Amp with and including replacing unserviceable spares like contacts, relays etc and other minor spares and testing complete all as directed.
M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI earth strip 32 mm x 6 mm, by means of nut bolts, check nuts and washer of the GI . Earth wire connected upto main earth point/DBs alongwith 40mm dia GI pipe, light grade, including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4) cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion.
M&L in repairs, air termination, single pointed, aluminium rod 12 mm dia and 300 mm long, fixing and testing on OH Tank as directed by Engr-in-Charge.
M&L in repairs, aluminium strip 25 mm x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete fixing and testing on OH Tank as directed by Engr-in-Charge.
M&L for repairs/refixing of loose GI earthing strip of size 32 mm x 6 mm thick on and including wooden gutties connecting to earthing and the test point of the lightening arrester of the overhead tank all as per existing and as directed. Note : GI Strip if corroded will be replaced by new where directed and the same shall be measured & paid separately as 'Supply only' under respective item
Supply only GI earthing strip of size 32 x 6 mm thick all as per existing and as directed.
S&F in repairs, 4 Pole, MCCB, 400 Amp, 50 Hz, 415 Volts, adjustable type with rupturing capacity 36 KA all as specified and as directed.
S&F in repairs, 4 Pole, MCCB, 250 Amp, 50 Hz, 415 Volts, adjustable type with rupturing capacity 36 KA all as specified and as directed.
S&F in repairs, 4 Pole, MCCB, 200 Amp, 50 Hz, 415 Volts, adjustable type with rupturing capacity 36 KA all as specified and as directed.
S&F in repairs, 4 Pole, MCCB, 125 Amp, 50 Hz, 415 Volts, adjustable type with rupturing capacity 36 KA all as specified and as directed.
S&F in repairs, 4 Pole, MCCB, 160 Amp, 50 Hz, 415 Volts, adjustable type with rupturing capacity 36 KA all as specified and as directed.
S&F in repairs, push button (Red and Green colour) switch of existing size and shape complete all as specified and as directed.
M&L for replacement of LT Panel wiring with new wiring using new cables of same size as per makes given here-in-after including replacement of lugs, thimbles etc complete all as directed .
M&L for replacement of LT Panel CT coils as per exiting size and make complete all as directed.
M&L for replacement of R Y B phase indicators complete set of make as per existing complete all as directed.
M&L in repairs for coupling protection/guard cover fabricated out of 3mm thick MS sheet and flat iron 40X6mm all around as iron frame work with fixing arragement complete and duly painted with two coats of anticorrosive bituminous paint over a coat of anticorrosive bituminous primer all as specified and as directed.
S&F in repairs, pumpset display boards made from ply wood with laminated Display boards of exisiting size at site all as specified and as directed.
S&F 1100 volts grade heavy duty cable, 70 sqmm, single core, PVC insulated, copper conductor, served with inner sheathing of PVC tape and overall PVC sheathed including taking down old unserviceable cable all as specified and as directed.
M&L in repairs, PTFE Teflon Graphite Gland packing rope of size.10mm/12mm/14mm all as specified and as directed.
M&L for bearing grease HP/BP type servo Gem Natra-3/Lithon-3. in 5 kg pack all as specified and as directed.
Supply & Refiling Engine oil 20 W 40 turbo synthetic superior quality engine oil all as specified and as directed.
Repair to voltage stabilizers, 3 phase, 4 wire system, upto 200 KVA at site by opening carefully from top, taking out coils / connections, cleanig coils, checking defective joints / soldering / jointing, balance control, oil cool AC synchronous motor 10 kg/CM Gear Assembly control card switches rotary switch toping up of transformer oil brush carban Dimmer Assembly with all connected item re-assembling and testing on full load and making fully servicable including M&L for spray painting with supper enamelled paint of approved colour complete all as specified and as directed.
Taking up or down choked CI water mains 80 mm bore including all fittings with spigot and socket ends including burning out joints, recovering lead and proper cleaning by internal brushing, removing chalkings and refixing/relaying in same place, jointing, pressure testing and washing out complete all as specified and as directed. Note : Run lead joint will be measured and paid seperately
All as per serial item No 138 but for 100 mm bore.
All as per serial item No 138 but for 150 mm bore.
All as per serial item No 138 but for 200 mm bore.
All as per serial item No 138 but for 250 mm bore.
M&L for run lead joints suitable for 80mm bore dia pipe, spigot and socket ends complete and pressure testing all as specified and as directed.
All as per serial item No 143 but for 100 mm bore pipe.
All as per serial item No 143 but for 150 mm bore pipe.
All as per serial item No 143 but for 200 mm bore pipe.
All as per serial item No 143 but for 250 mm bore pipe.
S&F Rubber Lined Nov Return Valve B-02 (Ball Type) for 80 mm bore size , cast iron body, flanged end, including neophrene ball and by pass arrangement complete including suitable flanges, nuts, bolts, washers and rubbber gaskets including dismantling and taking down old unserviceable non return valve all as specified and as directed.
All as per serial item No 148 but 100 mm bore.
All as per serial item No 148 but 150 mm bore.
All as per serial item No 148 but 200 mm bore.
S&F cast iron body ball type foot valve flanged B-05(N) of 80mm bore size, including suitable flanges, nuts, bolts, washers and rubbber gaskets including dismantling and taking down old unserviceable foot valve all as specified & as directed.
All as per serial item No 152 but 100 mm size.
All as per serial item No 152 but 150 mm size.
All as per serial item No 152 but 200 mm size.
S&F XLPE insulated screened PVC bedded galvanised steel strip or wire armoured UG heavy duty electric cable with aluminium conductor 1100 volts grade, 240 sqmm 3.5 core size, laid in trenches under floor/roads/hard standing along poles etc including taking out existing cable all as specified and as directed.
Cleaning of area around OH tanks, UG sumps, water supply installations by cutting and dressing of the existing vegetation (small trees/ bushes/ plants/ grass, etc) and removing off the premises all as specified and as directed by Engineer-In-Charge.
M&L for chamber cover, fabricated out of angle iron of size 40mm x 40mm x 6 mm in framework embedded fixed in PCC coping, 3mm thick MS sheet cover, flat iron 40mm x 6mm all around and diagonally and hinged to the angle iron frame work with locking arragement and handle, duly painted with two coats of anticorrosive bituminous paint over a coat of anticorrosive bituminous primer including taking down existing chamber cover all as specified and as directed.
Supply only chlorine test kit with coloured ample complete with all testing fitments and OT solution in Rexene finished box complete set all as per existing and as directed.
Supply only PH test kit with coloured ample coverd under BTB (range 6.0 to7.0) or phenol red (range 6.8to 8.4) with necessary fitments and 100ml testing solution in Rexene finished box complete set all as per existing and as directed.
Supply only calcium hypo chlorite, dry free flowing and free from lumps of following generic specification : (a) Aailable Chlorine - Min 65 % (b) Particle size ( passing through 1.70 mm IS sieve) - min 99.5 % (c) water insoluble matter - max 6% (d) calcium hydroxide - max 4% (e) Sodium chloride - 15% complete all as specifed and diected . Make : Any make approved by E-IN -C .
M&L for dewatering, cleaning of OH reservoir, 1,00,000 gallons capacity, with staging of tank exc 15 m but not exc 24 m at location 'AC Depot Pump House & KLP', with high pressure jet to remove all mosses, algae, dirt, deposits and other sediments, scrubbing of internal surface with steel wire brush and removal of dirty water with sludge machines / industrial vacuum cleaners and disposal of the same to a safe distance including , Sterilizing the complete, internal surface of the tank by using ISI mark Gd I bleaching powder / Liquid Chlorine, wash with fresh water, drying up and writing the words on external wall at visible place ''Military Engineer Services, Tank Capacity & Date of Cleaning'' using synthetic enamel paint in white colour over black background and letters of height 50 mm height and 40 mm width complete all as specified and as directed.
All as per serial item No 162 but OH reservoir 1,50,000 gallons capacity with staging of tank exc 8m but n exc 15m at location 'New KLP'.
All as per serial item No 162 but OH reservoir 50,000 gallons capacity with staging of tank exc 15m but n exc 24m at location 'AC Depot Pump House & CQA(V).'
All as per serial item No 162 but UG Sump of 14,00,000 gallons capacity at location ' Dhobhighat Pump House'
All as per serial item No 162 but UG Sump of 8,00,000 gallons capacity at location ' Bhingar Pump House'
All as per serial item No 162 but UG Sump of 5,00,000 gallons capacity at location ' KLP, Dhobighat'
All as per serial item No 162 but UG Sump of 4,00,000 gallons capacity at location ' Jk Road family qtrs'
All as per serial item No 162 but UG Sump of 2,50,000 gallons capacity at location ' Dhobighat Pump House'
All as per serial item No 162 but UG Sump of 1,50,000 gallons capacity at location ' AC Depot Pump House'
All as per serial item No 162 but UG Sump of 75,000 gallons capacity at location ' AC Depot Pump House'
All as per serial item No 162 but UG Sump of 30,000 gallons capacity at location 'Bhingar Pump House'
M&L for preparation of exposed old plastered or unplastered surfaces of semi-underground RCC sump, 14,00,000 gallons and applying one coat of cement base paint of colour as approved by GE and painting a square portion of 1 m X 0.5 m with black synthetic enamel paint and writing letters on it with white paint i.e. Capacity, date of cleaning, Location etc. all as specified and as directed. Note : Size of letter shall be as directed by Engineer-in-Charge.
All as per serial item No 173 but semi-underground sump of capacity 8,00,000 gallons
All as per serial item No 173 but semi-underground sump of capacity 5,00,000 gallons
All as per serial item No 173 but semi-underground sump of capacity 4,00,000 gallons
All as per serial item No 173 but semi-underground sump of capacity 75,000 gallons
All as per serial item No 173 but underground sump of capacity 2,50,000 gallons
All as per serial item No 173 but underground sump of capacity 1,00,000 gallons
All as per serial item No 173 but underground sump of capacity 30,000 gallons
M&L for preparation of old steel surfaces of ladder for 20m staging overhead water tank and applying one coat of synthetic enamel black paint all as specified and as directed.
M&L for PVC netlon jallies with wooden battens of sectional area n exc 13 Sqcm, wooden beads n exc 75mm girth duly fixed with nails, and fitted on top entry of over head reservoir and specified windows to prevent entry of birds/dirty particals all as specified and directed.
M&L for taking down carefully, existing unservicable water level Indicator from OH tank/ UG sump and repair with and including replacement of steel wire 4mm dia (8 SWG), MS V Shaped Pully 3NOs, PVC Float 01 Nos, MS indicator, scraping, cleaning and painting steel surfaces complete, marking levels with night glow radium paint, and fixing in position and testing for proper function complete all as specified and directed.
M&L for complete removal of old paint by scrapping, cleaning steel surface, preparation and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed. Note : Work shall be carried out for OH tanks of any height and UG sumps.
M&L for complete removal of old paint by scrapping, cleaning gun metal surface of sluice valves/non return valves of any size, preparation and applying two coats of synthetic enamel paint over a coat of red oxide primer all as specified and as directed.
M&L for preparation of old external surfaces of MS ERW pipes exc 10 cm width or girth and applying one coat of black bituminus paint complete all as specified and as directed.
M&L for complete removal existing paint, preparation of old steel and iron surface of any description over 10cm width or girth and applying two coats of synthetic enemel paint over a coat of zink cromate primer complete all as specified and as directed.
Dismantling old sign board and M&L for New Electric sign board of Mild steel Sheet, fabric material of size 2 mtr X 1.5 mtr write down MILITRY ENGINEER SERVICES, GARRISON ENGINEER (SOUTH) AHMEDNAGAR,and the name of the pump house will be given by department with MES logo, fixed on existing site and suitable panel wiring with electric LED tube light fittings of 20 watt - 04 Nos complete all as specified and directed.
Supply, install, testing and commissioning factory made cubical feeder piller Box Ourdoor double Door Type CPRI approved with front open including door locking arrengement. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of MS flat iron 40mm x 6mm & angle of 40 x40 x6mmframe with legs of 450 mm long embedded in PCC (1:2:4)btype B2 platform of suitable size including necessary excavation & earth work , and dust & vermin proof painted outside & inside with one coat of Red oxide & two coats of approved make gray enameld paint complete pre wired with suitable size of copper conductor & Aluminium bus bar strip 75mm x10mm thick connection for all switchgear including jointing material for UG cables & aluminium lugs & commissioning of the APFC PANEL WITH Metalized poly propyleneheavy duty CAPACITOR AND MCCB 200 Amp as INCOMER for 3 phase 440 V 50 HZ system for permissible non liner load 15% of 125 KVAR with 5 steps. Panel comprises of following items including taking down existing pannel box with framework all as specified and as directed. (Location : KLP Pump House , Dhobhighat pump House , Bhinghar pump House )
Supply, install, testing and commissioning factory made and tested (including CPRI type test certified) LT Panel box, Indoor type, floor mounted, compartmantalised and IP-54 suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, all as specified and directed, having bus bar chamber with insulated copper bus bars installed on porcelain insulators. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of 40x40x6mm angle iron , powder coated, Front and rear opening type with aprons for cable entry with double door shutter and locking arrangement comprises of following items including taking down existing pannel box with framework all as specified and as directed. Location : AC Depot Pump House (a) MCCB 80 Amps, 3 pole, 36 KA, 415 volts grade, with thermal magnetic - 01 No (b) Digital Volt meter and Amp meter - 01 Nos ,415 volts, 50 Hz AC supply -01 set. (c) Neon indicating lamps (R, Y & B) -01 Set. (d) 40 A contractor - 02 No. (e) 32 A contractor- 01 No. (f) S - D Timer - 01 No (g) Tharmal Overload relay 24 - 40 - 01 No including necessary connection. (h) Starter 30 HP FASD Fully automatic star delta starter Make - L&T-01 set , (i) MCB SP 6 Amp -04 Nos, (J) CT 100/5 A -03 Nos, Connector PB 50 -10 Nos,Push button LED -01 Nos Note : Panel design will be approved by GE.
Supply , Installation ,Testing & Commissioning factory made cubical feeder piller Box Ourdoor double Door Type CPRI approved with front open including door locking arrengement. The panel shall be dust and vermin proof, made of 3.15mm CRCA MS sheet and with base frame of MS flat iron 40mm x 6mm & angle of MS flat iron 40mm x6mm & angle of 40 x40 x6mmframe with legs of 450mm long embedded in PCC (1:2:4)btype B2 platform of suitable size including necessary excavation & earth work , and dust & vermin proof painted outside & inside with one coat of Red oxide & two coats of approved make gray enameld paint complete pre wired with suitable size of copper conductor & Aluminium bus bar strip 75mm x10mm thick connection for all switchgear including jointing material for UG cables & aluminium lugs & commissioning of the APFC PANEL WITH Metalized poly propyleneheavy duty CAPACITOR AND MCCB as INCOMER for 3 phase 440 V 50 HZ system for permissible non liner load 15% of 100 KVAR with 5 steps Panel comprises of following items including taking down existing pannel box with framework all as specified and as directed (Location : AC Depot Pump House , Dhobhighat pump House)
m/s shivam tools and equipment
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .