Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC 16 PRATAP NAGAR CHARBHUJA RAWATBHATA RAJASTHAN 323307 | RAWATBHATA | CHITTORGARH | RAJASTHAN | 323307 | ₹2.0 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹2.0 Cr+₹2.7 L (1.36%)Rejected-Finance | ₹2.0 Cr+₹2.7 L (1.36%) | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹2.3 Cr+₹33.6 L (17.2%)Rejected-Finance | ₹2.3 Cr+₹33.6 L (17.2%) | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹2.4 Cr+₹41.5 L (21.2%)Rejected-Finance 223 02 WARD NO 10 A DHURI DISTT SANGRUR | DHURI | SANGRUR | PUNJAB | ₹2.4 Cr+₹41.5 L (21.2%) | L4 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | M/s Sekinder Paul Sharma L2 | JR CONSTRSTRUCTION CO. L3 | M/S GUPTA CONSTRUCTION CO. L1 | SHARMA CONSTRUCTION COMPANY L4 |
|---|---|---|---|---|---|---|---|
| 1.00Sch 'A' Part-I (Building Work):-This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only. | |||||||
| 1.01 | Construction of block of OR Md accn including garages complete all as shown on drawings and as specified. | 2 | Each Block | 81,21,431 ₹1,62,42,862 | 96,25,000 ₹1,92,50,000 | 80,00,000 ₹1,60,00,000 Lowest | 97,00,000 ₹1,94,00,000 |
| 2.00 | Total Amount of Sch 'A' Part - II (Internal Water Supply Work) | 1 | Lump sum | 2,39,226.44 ₹2,39,226.44 | 2,66,105 ₹2,66,105 | 2,00,000 ₹2,00,000 Lowest | 4,03,190.64 ₹4,03,190.64 |
| 3.00 | Total Amount of Sch 'A' Part - III (Internal Electric Supply Work) | 1 | Lump sum | 3,36,817.84 ₹3,36,817.84 Lowest | 3,66,106 ₹3,66,106 | 4,00,000 ₹4,00,000 | 4,88,141.8 ₹4,88,141.8 |
| 4.00 | Total Amount of Sch 'A' Part - IV (Plumbing Work) | 1 | Lump sum | 3,63,442.85 ₹3,63,442.85 | 2,49,693 ₹2,49,693 Lowest | 2,50,000 ₹2,50,000 | 2,77,437.29 ₹2,77,437.29 |
| 5.00 | Total Amount of Sch 'A' Part - V (Area Drainage Work) | 1 | Lump sum | 1,49,287.17 ₹1,49,287.17 Lowest | 1,73,086 ₹1,73,086 | 2,00,000 ₹2,00,000 | 2,16,358.22 ₹2,16,358.22 |
| 6.00 | Total Amount of Sch 'A' Part - VI (Sewage Disposal Work) | 1 | Lump sum | 1,89,999 ₹1,89,999 | 1,61,291 ₹1,61,291 Lowest | 2,00,000 ₹2,00,000 | 2,15,055.95 ₹2,15,055.95 |
| 7.00 | Total Amount of Sch 'A' Part -VII (Road, Path, Culvert and Hard Standing Work) | 1 | Lump sum | 12,67,960.08 ₹12,67,960.08 | 12,80,000 ₹12,80,000 | 12,00,000 ₹12,00,000 Lowest | 14,24,674.25 ₹14,24,674.25 |
| 8.00 | Total Amount of Sch 'A' Part - VIII (External Water Supply Work) | 1 | Lump sum | 2,52,199.34 ₹2,52,199.34 | 2,83,700 ₹2,83,700 | 2,00,000 ₹2,00,000 Lowest | 4,25,055.08 ₹4,25,055.08 |
| 9.00 | Total Amount of Sch 'A' Part - IX (External Electric Supply Work) | 1 | Lump sum | 54,888 ₹54,888 | 50,000 ₹50,000 Lowest | 50,000 ₹50,000 Lowest | 54,877.43 ₹54,877.43 |
Tender Value
₹2.2 Cr
EMD Value
₹3.0 L
Closing Date
20 Dec 2025, 6:00 pmClosed
Chief Engineer Udhampur Zone
HQ Chief Engineer Udhampur Zone, PIN-900386, C/O 56 APO
PROVN OF MD ACCN FOR 12 X OR AT RLT VIHAR UNDER GE (N) AKHNOOR
2025_MES_739604_1
87979-A/E8
Open Tender
Civil Works
Lump-sum
547 days
Akhnoor
As per NIT
8 documents required · 8 mandatory
₹2,000
GE (N) Akhnoor
₹3.0 L
Yes
HQ Chief Engineer Udhampur Zone
16 Mar 2026
13 Nov 2025
23 Dec 2025
13 Nov 2025
20 Dec 2025
15 Dec 2025
14 Nov 2025 - 24 Nov 2025
26 Nov 2025
Construction of block of OR Md accn including garages complete all as shown on drawings and as specified.
Total Amount of Sch 'A' Part - II (Internal Water Supply Work)
Total Amount of Sch 'A' Part - III (Internal Electric Supply Work)
Total Amount of Sch 'A' Part - IV (Plumbing Work)
Total Amount of Sch 'A' Part - V (Area Drainage Work)
Total Amount of Sch 'A' Part - VI (Sewage Disposal Work)
Total Amount of Sch 'A' Part -VII (Road, Path, Culver and Hard Standing Work)
Total Amount of Sch 'A' Part - VIII (External Water Supply Work)
Total Amount of Sch 'A' Part - IX (External Electric Supply Work)
Total Amount of Sch 'A' Part -X (Compound Wall , Fencing and Gate Work)
Sch 'A' Part - XI (Misc Items of work) Note : This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under col.5 signifies this fact only.
Concealed sub main wiring of two run with 06 sqmm single core PVC insulated, FRLSH, flexible multi stranded copper conductor cable 1100 volts grade, drawn through and including PVC conduit 25mm dia , medium grade, ISI marked and fixed, including cutting /chasing as required and its accessories including one run of 6 Sqmm single core PVC insulated, FRLSH, multi stranded copper conductor cable as earth continuity conductor in green colour, connected to common earth dolly including taking down existing sub main wiring, complete all as specified and as directed. Note:- Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit only.
Point wiring complete with 1.5 sqmm PVC insulated, FRLSH, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20mm dia medium grade and including cutting, chasing work at any height and all accessories are concealed in walls / roofs / floors / ceiling etc; metal flush boxes of suitable modules as directed with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick, including modular top cover plate as per numbers of switch modules for fixing of modular switches,sockets,fan regulators, red colour indicator, blank plates etc. as approved colours and including 1.5 Sqmm PVC insulated multistranded FRLSH unsheathed (Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat including providing putty and white cement for smooth finishing of existing surface complete all as specified and directed for the following:- Note:- All necessary accessories such as modular steel box, top cover plate, blank plate, screws, washers and all modular electrical fixtures are to be used same make/brand only.
One light/fan/bell point controlled by one switch
One socket outlet 05 Amps on the same board
One socket outlet 05 Amps on independent board
One light point controlled by two way switch
(i) Bus bar chamber with electrolytic grade aluminium strip with heat shrinkable sleeves with colour code supported on epoxy resin based insulators 4 strip, of suitable length for current rating minimum 250 Amps. (ii) MCCB, 4 pole, 415V AC, current rating 100 Amps, breaking capacity 16 KA -01 No (Incoming) (iii) MCCB, 4 pole, 415V AC, current rating 63 Amps, breaking capacity 16 KA -03 No (Outgoing) (iv) Voltmeter digital type 0-500 V, 96mm square flush panel mounting -01No (on incoming supply) (v) Ammeter digital type 0-200 A, with CTs of suitale ratio, 96mm square, flush panel mounting - 01 No (on main load) (vi) Copper wiring complete all as directed by the Engr-in-Charge
Double walled corrugated (DWC HDPE) pipe of size 40mm/32mm including snap fit coupler conforming to IS 16205 for protection of under ground cable complete all as specified and directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.36 MB
Drg5.pdf
Additional Documents • 5.08 MB
Drg1.pdf
Additional Documents • 7.23 MB
Drg2.pdf
Additional Documents • 1.18 MB
Drg3.pdf
Additional Documents • 1.66 MB
Drg4.pdf
Additional Documents • 3.00 MB
1-37_merged.pdf
Tender Documents • 7.10 MB
BOQ_828148.xls
BOQ • 5.57 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .