Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 LAccepted-Finance | ₹12.7 L | L1 | Accepted-Finance Accepted |
| 2 | L2₹13.0 LAccepted-Finance 21 10 SHOP NO 1 SECTOR 3 MAHABINI DELHI 110085 | NORTH WEST | DELHI | 110085 | ₹13.0 L | L2 | Accepted-Finance Accepted |
| 3 | L3₹13.6 LAccepted-Finance 11 C GROUND FLOOR DYADER ENCLAVE VIKAS NAGAR ITTAM NAGAR WEST DELHI 110059 | WEST | DELHI | 110059 | ₹13.6 L | L3 | Accepted-Finance Accepted |
| 4 | L4₹14.6 LAccepted-Finance 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | ₹14.6 L | L4 | Accepted-Finance Accepted |
| 5 | L5₹14.9 LAccepted-Finance N A | NA | NA | 121004 | ₹14.9 L | L5 | Accepted-Finance Accepted |
Tender Value
₹18.6 L
EMD Value
₹37,138
Closing Date
17 Feb 2026, 3:00 pmClosed
Executive Engineer (E)
Executive Engineer (E),North West, Elect. Div., PWD, ISBT, Kashmere Gate, Delhi-110006
Urgent electrical works at Newly Created Sub Divisional Magistrate Office Nangloi, Kirari Under North West District, at Nangloi Delhi.
2026_PWD_286629_1
187/EE(E)/NWED/PWD/2025-26
Open Tender
Electrical Works
30 days
North West Delhi
As per NIT
10 documents required · 10 mandatory
₹0
₹37,138
Yes
20 Feb 2026
10 Feb 2026
17 Feb 2026
10 Feb 2026
17 Feb 2026
10 Feb 2026
SH-I EI work. Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. a) Group C
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. a) Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit/channel as required. a) 3 x 1.5 sq. mm
b) 6 x 1.5 sq. mm
c) 3 x 4 sq. mm
d) 6 x 4 sq. mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. a)20 mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 A switch
b) 3 pin 5/6 A socket outlet
c) 15/16 A switch
d) 6 pin 15/16 A socket outlet
e) Blanking Plate
f) Bell push
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. a) 1 or 2 Module
b) 3 Module
c) 6 Module
d) 8 Module
e) 12 Module
Supplying, installation, testing and commissioning of 10 litre electric storage water heater (geyser), 5-Star BEE rated, 2000 W, 220–240 V AC, with glass-lined inner tank, safety valve, thermostat, wall mounting accessories, complete in all respects as per BIS/ISI standards and directions of Engineer-in-Charge.
SH :-II Fans & Light Fittings S/I/T/C of 1200 mm sweep BEE star rating energy efficient ISI marked ceiling fan capacitor type with double ball bearing suitable for operation of single phase AC supply with power Consumption of Max. 50W capable to deliver 220 CFM (min.), speed of 350 rpm (min.) i/c wiring the down rod of standard length (upto 30 cm) with 1.5 Sqmm FR PVC insulated copper conductor single core cable etc as reqd.
SITC of wall fan 400 mm sweep oscillating type having Metal blade complete with all accessories such as front jaali i/c connection etc. as reqd
Supplying & fixing of 300/305 mm sweep 1400 RPM 230 Volt 1-ph 50 Hz AC heavy duty Exhaust fan in the existing opening including making good the damage, connection, testing and commissioning etc. as reqd.
LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K/ 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) a) 36 watt
LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) a) 18- 22 watt
LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120lm/Watt) Supplying, installation, Testing & Commissioning of LED Recessed / surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim. a) 12 -15 watt
Supplying, Installation, testing and commissioning of pre-wired, powder coated aluminium channel housing 10 watts LED tube fitting luminaire having minimum 95 Lumen per watt, CCT 5700K to 6500K, power factor >0.90 ,CRI > 80% complete with all accessories etc. directly on ceiling including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
New Generation IP65 LED, 25 Watt post top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution spun aluminium landscape luminaire with high power LEDs as light source. Opal Cover offers soothing uniform illumination for different applications etc. as required at site.
LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR -15, lenses for beam angle 30 deg-120deg as per the application and the project requirement., suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in- Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). a) 100 watt
SH :-III MCB, DB & Pump Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
b) Single pole and neutral
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing andn fixing 25 A modular socket outlet and 25 A modular SP MCB,“C” curve including connections, painting etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB/TPN/SPN MCB with thermomagnetic release and terminal spreaders & associated switchgears in the above cubical panel board/TPDB including drilling holes in cubicle panel, fitting strips for MCB ,making connections, etc. as required. a) 250 A,36KA,FPMCCB
b) 63 A, 10 KA , TPN MCB (C-Curve)
Supplying and fixing hot press moulded SMC box (sintex) of size 140mm x 140mm x 95mm i/c s/f neutral link sp mcb 0-32 amp on the existing pole /on the wall surface or recess repairing etc as reqd.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, multi core cable in then existing surface/ recessed steel/ PVC conduit/channel as required. a) 3 core 1.5 sq. mm
SITC of 3 HP Monobloc pumpset having a discharge range of (450-150) LPM ± 10 % tolerance for head range of (15-27) Metre ± 10% tolerance suitable for operation on 3 phase, 340 50Hz AC supply i/c flange cable joint, gasket, nut & bolts etc as required.
SH :- IV Fire safety Supply and fixing of following ABC type fire extinguisher (ISI marked MAP 90%) complete delivery hose horn, squeeze grip release valve, locking arrangement on wall with the help of necessary clamps and duly painted in red colour etc. as reqd. a) 6 kg capacity ABC type fire extinguisher (ISI)
Supply and fixing of 4.5 kg. capacity CO2 type fire extinguisher (ISI) marked complete delivery hose horn, squeeze grip release valve, locking arrangement on wall with the help of necessary clamps and duly painted in red colour etc. as reqd
Supplying & fixing of following accessories of fire fighting safety system i/c testing & commissioning etc complete as required. a) Fire Bucket 24 gauge 9 ltr. Capacity
Fire bucket stand without bucket for fixing 4 bucket (Angle Type)
Supplying, installation, testing & commissioning of emergency light in sheet steel body enclosure with hanging bracket arrangement duly powder coated having 2 nos. beam LED lamps of nominal lumen output of 1000 lms each with suitable size 12 volt rechargeable battery having back up of 4 to 5 hours including LED backlit asrylic signage of "EXIT" text in approved colour along with hanging bracket arrangement in housd etc. as reqd
SH :- V Air Conditioning Work Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). a) 1.5 TR with 5 Star BEE Rating
Dismantling of existing suitable 1.5 TR/2.0 TR capacity WTAC unit & both indoor & outdoor in case of STAC etc. with equipments complete as reqd.
Re-Installation of STAC Unit existing suitable 1.5 TR/2.0 TR capacity STAC unit & both indoor & outdoor in case of STAC etc. with equipments complete as reqd.
Supplying, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : a) 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
b) 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm
Supplying & charging of Refrigerant gas (R- 22/32/refrigerant suitable as per requirement of AC unit) in the following type capacity AC units i/c leakage testing removing the leakage, pressure testing, flushing the complete system, vacuumizing and gas charging complete as required.
Supplying and fixing of 25 mm dia. size medium class PVC conduit/pipe along with accessories in surface/recess including cutting the wall and making good the same in case of recessed pipe for AC drain as required at site.
Supplying, Installation, Testing and Commissioning of 25 Amp 3 Pin plug Top (ISI Marked) for the existing 1.5 TR/ 2 TR. capacity WTAC / STAC unit, etc as reqd.
SH :- VI Cable Laying and Panel Work Providing and fixing of PVC Trunking of following sizes complete with flexible cover, joint, endcap, cover on surface of wall/existing mounting etc. as required. a)105 mm x 50 mm
b) 32 mm x 20 mm
Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Al armoured power cable of 1.1 KV grade of following size on wall surface/recess as equired. a) size 3 X 10 sq. mm
Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE aluminium armoured power cable of 1.1 KV grade of following size direct in existing GI /HDPE/DWC pipe with complete fitting etc as required. a) size 3 X 10 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE al. conductor cable of 1.1 kV grade as reqd. a) 3 X 10 sq. mm (22mm)
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. a) 63 mm dia (OD-63 mm & ID-51 mm nominal)
SH :- VII LAN Work Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. a) 1 Run of cable
Supplying, Installation, Testing and commissioning of CAT6 Copper Information Outlet (IO) with face plate of color as per site requirement, should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Components should be from same OEM to maintain compatibility and interoperability etc. complete as required.
Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing: PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 25 mm
SH :- VIII Credit for Old item a) Assorted size of Copper Wire (1.5 sqmm/4 sqmm/6 Sqmm)
b) Assorted Size of Conduit (20mm/25mm)
c) Assorted MS boxes
d) Assorted 5/15 Switch/ Socket
e) Assorted Ceiling fan/ Wall Fan
f) Assorted Exhaust Fan
g) Assorted 2*2 Fitting/ Down Lighter/ Batten
h) Assorted Flood Light
i) Assorted 3 HP pump
j) Assorted STAC/WTAC
k) Assorted 3*10 sqmm cable
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.26 MB
BOQ_379479.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid