Executive Engineer
Office of the Executive Engineer M and H Division Anantnag
Electrification in Divisional Office, Snow Clearance Control Room Anantnag at Mechanical and Hospital Division Anantnag Balance work thereof
2026_PWDJK_324232_1
MHDA/TS/2026-27/55
Open Tender
Miscellaneous Works
Percentage
10 days
Mechanical and Hospital Division Anantnag
Refer NIT
7 documents required · 7 mandatory
₹200
Executive Engineer M and H Division Anantnag
₹5,540
10 Sept 2026
10 Sept 2026
17 Sept 2026
10 Sept 2026
17 Sept 2026
10 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing and Commissioning of 1Ton 3 star Inverter type (Hot and Cold) split Air Conditioner suitable for operation on AC supply single phase 50Hz 230V with hermetically sealed inverter compressor with air cooled condenser latest R410A/ R-32 refrigerant fan motor, start and run capacitors, relay and over load protector internal unit with one indoor and one outdoor unit. The indoor unit fitted on wall by employing suitable clamps and the outdoor unit will be placed on angle iron stand fitted with nut/bolts outside the room to avoid noise, including standard length of suitable size copper tubing upto 3 m covered with nitrilic foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ PVC insulated copper cable and a battery operated wireless remote unit.The job includes repairs to walls wherever the same are cut and the AMC of AC for a period of one year from date of successful commissioning.Also the job inludes supply and fitting of 3 kva automatic relay-type Voltage Stabilizer. | 1 | No | 60,000 | ₹60,000 |
| 2 | Supply of 150 ah tall tubular 12 V inverter battery with warranty not less than 60 months. | 1 | No | 15,000 | ₹15,000 |
| 3 | Supply, installation, testing and commissioning of 2000 VA (2 kVA), 24 V, single-phase pure sine wave inverter with inbuilt charger and automatic changeover, conforming to IS 16242/IEC standards, including supply of 2 Nos. 12 V, 220 Ah tall tubular lead-acid batteries (IS 13369/IS 1651) mounted on PVC/FRP battery trolley, complete with interconnecting cables, terminals, DC fuse/isolator, AC wiring, initial charging, commissioning with all accessories | 1 | Job | 71,500 | ₹71,500 |
| 4 | Supply and fixing modular 10A modular switch on modular switch board including connections (excluding cost of modular switch board). | 26 | No | 50 | ₹1,300 |
| 5 | Supply and fixing modular 10A modular socket on modular switch board including connections (excluding cost of modular switch board). | 5 | No | 200 | ₹1,000 |
| 6 | Supply and fixing of 16A sockets witch 16 A switches including connections | 6 | No | 500 | ₹3,000 |
| 7 | Supply and fixing of 4 modular plate including connections | 6 | No | 100 | ₹600 |
| 8 | Supply and fixing of 8 modular plate including connections | 3 | No | 150 | ₹450 |
| 9 | Supply and fixing of blank plate for switch board | 15 | No | 20 | ₹300 |
| 10 | Supplying and fixing of indicators on existing modular plate and switch box , incl. connections, etc. as required. | 6 | No | 60 | ₹360 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
Tendernotice_2.pdf
PDF • 0.31 MB
BOQ_1093384.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .