| 1 | L1₹11.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹17.1 L+₹5.0 L (41.5%)Rejected-AOC C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L2 | Rejected-AOC Other than Lowest Bidder | |
| 3 | L3₹17.3 L+₹5.1 L (42.4%)Rejected-AOC | L3 | Rejected-AOC Other than Lowest Bidder | |
| 4 | L4₹19.5 L+₹7.4 L (61.0%)Rejected-AOC | L4 | Rejected-AOC Other than Lowest Bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in Cat b(i) |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
19 Jul 2022, 6:00 pmClosed
GE (S) Jaipur
Garrison Engineer (South) Jaipur Military Engineer Services Kalyan Marg, Jaipur302006
REPAIR AND MAINT OF INTERNAL ELECTRIFICATION, LIGHTING AND ALLIED E/M WORKS SERVICES AT OFFICE, GUEST HOUSE AND RESIDENTIAL COLONY OF PCDA UNDER GE(S) JAIPUR
2022_MES_530128_1
GE (S)/J-12P /2022-23 8729/E8
Open Tender
Civil Works
Item Rate
240 days
Jaipur
Class E category b(i)
9 documents required · 9 mandatory
₹500
GE (S) Jaipur
₹40,000
Yes
2 Sept 2022
10 Jun 2022
21 Jul 2022
10 Jun 2022
19 Jul 2022
30 Jun 2022
Amount
Taking down carefully aluminium Point wiring (light fan socket or power) complete fittings such as switches, ceiling rose, pendants fan regulators, tube light fittings etc and making good disturbed surfaces of wall floors etc.
M&L Point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 Sq. mm (nominal area), single core, FRLS insulated, PVC insulated and unsheathed stranded cable 1100 volts grade, confirming to IS-694/ISI marked in and including PVC casing caping, medium grade, ISI marked, with mild steel sunken boxes with earth dolly zink coated and including mounting frame and over cover plate, including PVC insulated stranded copper conductor 1.5 Sqmm (nominal area) single core cable as earth continuity conductor to common earth and connecting to earth dolly.
(a) One light / fan / bell controlled by one, one way switch.
(b) One 3 pin 5 Amp socket out let on the same board with other switches
(c) One 5 Amp socket outlet on independent board controlled by one, one way switch.
Description all as per item No 2 here in befor but with 1100 volts grade copper standard conductor cable of size 2.5Sqmm for 3 pin switch socket outlet 15Amp on independent board complete all as specified.
S&F switch, piano flush type 230/250 volts :-
(a) Single pole, one way 5 Amp rating
(b) Single pole, one way 15 Amp rating
(c) Bell push, one way 5 Amp rating
S&F Socket outlet 3 pin 5 Amp 2 in 1 flush type, 230/250 Volts grade fixed on top covers (catered in point wiring above) :-
S&F Socket outlet 2 in 1 3 pin 5 and15 Amp flush type, 230/250 Volts grade fixed on top covers (catered in point wiring above) :-
M/L for Ceiling rose polycarbonate isolate body 65 mm x50 mm three terminal AC 230 volts flush type complete all as specified.
M & L Electric bell, A/C, 230 volts, single pole, Multi Music type.
M/L for Ceiling fan regulator 100 watt stepped type electronic suitable for 1200mm /1400mm sweep flush type complete all as specified.
Supply & fix in repair T5 integrted batten LED Light fittings 1 x 20 W ,240 volt( size-4 feet/1136 mm) long life, surface/wall mounting IP 20, luminaire per watt (Minium) extruded alluminium housing with frosted PMMA diffuser with high brightness LEDs complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size. Make - Crompton Cat No LTTB4F20WLED/W or equivelent cat part in other makes as per Appendix 'B'.
All as per item No 10 here in before, but LED Batten light fitting 1 x 10 W ,240 volt( size-2 feet). Make - Syska Cat No SSK-T5-12W or equivelent cat part in other makes as per Appendix 'B'.
Supply & Fixing in repair Retro LED T-8 tubular lamp IP 20 linear LED T8 20 watt with extruded aluminium/ PC body and PC diffuser complete with inbuilt driver. Make - Crompton cat pt No- LTT8-20 or equivelent cat part in other makes as per Appendix 'B'.
Supply & Fixing in repair Decorative box type fitting,Blue coured end caps complete for Retro LED T-8 tubular lamp IP 20 complete. with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size. Make - Crompton cat pt No- DMLN1LT8-16 or equivelent cat part in other makes as per Appendix 'B'.
Supply & fix in repair LED surface downlight Square ( Economy range ) 6500K/3000 K with electronic driver LED fittings 1 x 18 W complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size Make - Syska cat Pt No SSK-SDS-18W-N or equivelent cat part in other makes as per Appendix 'B'.
Supply & fixing in repair Energy saving new generation 10 W LED IP -65 Bulkhead energy efficient wall mounted made of dia cast aluminium wiht with opal diffuser complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size Make - WIPRO cat part no CDL DA 11065 or equivelent cat part in other makes as per Appendix 'B'.
Supply & fix in repair wall Bracket light asthetically designed with B22d & E27 lamp holder including 10W LED Lamp with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size. Make - HAVELLS cat part no LHDL06160099 or equivelent cat part in other makes as per Appendix 'B'.
S&F in repair Fency light fitting weather proof corrosion wall mounted opel colour decorative ovale shape engineering with pc cover suitable for1x9 w LED Bulb etc complete with all accessories pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size.Make - PHILLIPS cat part no 30575 or equivelent cat part in other makes as per Appendix 'B'.
M & L in repair for LED Energy saving 60 watt fitting IP 66 flood light luminaire of pressure die cast aluminium housing with anodised Al reflector & enclosed with toughned glass including provision of fixing arrangement made out of MS flat 25x4 mm with suitable size nut,bolt and washer in existing pole/biulding including welding in pole /grouting work in wall complete all as specified and directed by Engr-in-Charge. Make- HAVELLS cat part no JETA ALBA FLOOD LIGHT 60w or equivelent cat part in other makes as per Appendix 'B'.
Supply and Fixing in repair security lights LED 45 W Energy saving & Environmental friendly long life versatile pressure die cast aluminium IP 66 LED Wall mounted Light Luminaries are made of die casted aluminium body and toughened glass cover for uniformlight spread cames LED technology of Britelite. including bracket made out of suitable size of GI medium grade tubing and fixed with clamps nuts and bolts, washer complete all as specified . Make- CG cat Pt No-LSTP-45-CDL or equivelent cat part in other makes as per Appendix 'B'.
M&L in repair 2 tier LED garden light conical shape with top cover at bottom, round shape and top cover at top with pointed bolt opal finish glass made up of polycabonate body suitable for B-22 Base (retrofit) with 9 watt LED lamp complete all as specified and approved by engineer in charge. Note:- (Cost of wiring with nearest garden light/junction box with 1.5 sqmm 3 core wire and GI pipe of suitable dia. not less than 1 mtr length with painting with two coat enamel paint will be inclusive in above quoted price.) Make- CG cat Pt No-LDLLP10-CDL/NW/WW or equivelent cat part in other makes as per Appendix 'B'.
M&Lin repair decorative LED Globe Gate light (Moon prismetic ) made up of high grade unbreakable poluycarbonate material suitable for B-22 Base (retrofit) with 14 watt LED lamp complete all as per sample Make : Havells Cat No LHFXBO1TN6F035 or equivelent cat part in other makes as per Appendix 'B'.
Supply and fix in repair lamp holder polycarbonate insulated body with back plate for batten fittings including 10 LED lamp complete all as specified and directed.
Supply & Fixing in repair LED Lumeno 10 W Bulb E27 WW Ball Lamp suitable for Lumen output 1020, (lm) complete Make- Havells cat pt No-LHLDEBHEMD8 X010 or equivelent cat part in other makes as per Appendix 'B'.
Supply & fixing in repair LED Lumeno 15 W Bulb E27 WW Ball Lamp suitable for Lumen output 1380, (lm) complete Make- Havells cat pt No-LHLDEBHEMD8Z015 or equivelent cat part in other makes as per Appendix 'B'.
Taking down of Old exiting U/S submain wiring PVC insulated aluminium conductor wiring with out disturbing existing PVC conduit complete.
M & L Sub main wiring with following sizes cable single multi stranded copper conductor FRLS PVC insulated but unsheathed cable 1100 volts grade drawn through existing PVC conduit/ duct/ trunking etc fixed on surfece of wall or ceiling all as per IS earth continuity conductor to common earth and connected to earth dolly. (a) Two run of 6 sqmm and one run of 6.0 sqmm earth cable.
S&F factory made, sheet metal distribution board, double door, protection class IP 42 suitable for mounting MCB/MCCB, confirming to IS-13032, IS-8623, BS-5484 with minumum 200 amps, copper bus bar of the under mentioned rating:-
(a) SP&N 4 way
(b) SP&N 12 way
(c) SP&N 8 way
(d) TP&N 4 ways
S&F MCB 10 KA , C series thermomegnatic adjustable rupturing capacity of the under mentioned type and rating :-
(a) SP 5 to 32 amps
(b) SPN 32 to 63 amps.
(c) TPN 32 to 63 amps.
S&F MCCB 4P 100 Amp, with breaking capacity 25 KA rating adjustable type complete.
Supply and fix sheet metal enclosure complete with metallic plug and socket heavy duty moduler type 3 pin (2P + Earth), 20 amp rating single phase 240 volts complete with MCB SP 20 amp “C” series
Earthing complete with galvanized steel plate electrode 60cmx60cmx 6.3mm thick buried directly in ground earth pit not less than 2.25 meter deep below normal ground level with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth lead GI strip 25x4mm by means of bolts, nuts, check nuts and washer of galvanized iron or steel all as shown in electrical plate No 5 of SSR Part-I connected to continuous earth wire on pole all as specified and testing on completion, including provision of earth wire protected by 40mm dia GI light grade protection pipe from test Point to main board and 20mm GI medium grade watering pipe funnel, PCC earth pit and RCC cover charcoal, salt and GI wire including excavation and earth work etc complete all as directed at site. ( Note : PCC Chammer shall be constructed atleast 1.5 mtrs away form the earth electrode of the earth pit and pipe for watering shall be provided in slanting manner).
S&F in repair PVC casing & caping with inclusive all accessories junction boxes for make some power point as specified.
S & F in reapir Plug top 3 pin 15 Amps, 230 Volt AC, ISI marked complete as specified.
S & F in reapir Plug top for 3 pin 5 Amps, 230 Volt AC, ISI marked complete all as specified.
S&F in reapir Gang box suitable for make power point make ISI Marked
S&F in reapir capacitor AC for 440 volts 50 Hz of capacity 2/2.5 Mfd incl PVC clamp connector etc.
S& F in reapir LED tube rod 20 watt suitable for 4 feet long 40 watt FTL/ 20 watt LED fitting.
S&F in reapir LED tube rod 10 watt suitable for 10 watt LED/20 watt FTL 2 fet long fitting.
Taking down old /defective fan (ceiling or exhaust ) from hook in wall and dismantling all parts of fans taking out old burnt copper winding of starter mortar and re-winding with superior quality super enamelled copper wire of existing gauge including varnishing of winding replacement and reassembling of all parts of fan including testing complete & refixing to existing hook or hole of following size of fan including painting of fan as per existing colour:- Note :- Replacement of parts will be measured seperately as supply only if required.
(a) ceiling fan size 1200mm sweep.
(b) Exhaust fan size 300 mm
Supply only ball bearing No 6201or equivalent size
Supply only ball bearing No 6202 or equivalent size
Supply only ball bearing No 6203 or equivalent size
Supply only ball bearing No 6204 or equivalent size
Dismantling/taking down unservisable air conditioner 1.5TR/2.0TR capacity window type from any place and reinstall the AC at same location at the proper repairand testing complete all as directed.
All as serial item No. 44 here in before but AC 1.5/2.0 TR split type
M&L for servicing of 2TR/1.5TR capacity window type AC unit any make by cleaning with air pressure,tighting of bolts and nuts, arresting all leakages with necessary brazing/welding ensuring leak proof cleaning of condensor ,water line, checking of serviceability of fan ,motor ,compressor,relay ,capacitors thermostat,control circuit remote,sensor indicator electric circuits,replacing of unserviceable parts except compressor and charging of refrigerant gas and submit the report complete all as specified and as directed by Engr-in-charge. (Note : ( i) Replacement of compressor shall be measured and paid separately ( ii) Spare Parts required for replacement shall be measured separately under replacement items given here-in-after .( iii) (Gas will be measured and paid separately).
All as serial item No 46 here in before but for AC 2.0TR/1.5TR capacity split type any make.
M&L for disconnecting and removing U/S sealed compressor unit from 1.5 TR capacity window type AC including supply connecting with original sealed refrigeration compressor unit all as specified and as directed by Engr-in-charge.
All as serial item No 48 here in before but for AC 1.5TR capacity split type
All as serial item No 48 here in before but for AC 2 TR capacity split type
Supply only Running capacitor 45 to 50 MFD 230 volts, 50 Hz for window/split AC
Supply only Starting capacitor 100 to 120 MFD 230 volts, 50 Hz for window/split AC
Supply only Box type relay suitable for Window type AC 1.5 ton capacity.
Supply only Thermostatic switch with knob suitable for window type AC 1.5 TR.
Supply only Capacitor 4 MFD, 230 volts, 50 Hz
Supply only Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.5 TR Window type Air Conditioner
Supply only Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.5 TR Split type Air Conditioner
Supply only Blower Motor, single phase 230 Volts 1500 RPM, suitable for 2 TR Split type Air Conditioner
Supply only gas Mafron-22 in sealed cylinders. (Cylinders shall be return after use).
Supply only gas R-134 A in sealed cylinder. (Cylinders shall be return after use).
Labour only for Gas Charging (in situ) for AC 1.5/2 Ton and testing complete.(Gas will be paid and measured separately).
supply only remote complete for split type ACs 1.5 to 2 ton capacity complete all as directed by the Engr in Charge .
Supply only PCB suitable for 1.5/ 2 ton split type AC,s
Supply only contactor suitable for Split type AC capacity 1.5/2.0
Supply only fan blade suitable for out door unit of Split type AC capacity 1.5/2.0
Supply only blower complete with fins suitable for in door unit of Split type AC capacity 1.5/2.0
Disconnecting electrical connection and dismantling/ taking out indoor and out door unit of split type air conditioning of any make and capacity from any place and installation, commissioning and testing to another location including transportation from existing bldg to another bldg all as spacified and directed.
M & L for Supplying, laying, connecting and testing in trenches, under floors/ roads or on walls Cable XLPE insulated screened PVC bedded galvanized steel strips or wire armored, electric power cables (heavy duty) ISI marked with stranded aluminium conductor, 1100 volts grade, of size 95 sqmm, 3.5 core .
All as per item No 68 but 50 sqmm 3.5 core
All as per item No 68 but 16 sqmm 4 core (Note for item No 68.00 to 70.00 :- Change in aligment of cable will not be allowed without prior writing approval of GE.)
Material and labour for cutting floor and wall to fix GI pipe to protect XLPE cable and making good disturbed surfaces with proper PCC (1:2:4) type complete all as specified and directed. (Note: No Extra cost will be provided for variation in depth of wall/floor cutting and cost of PCC included in above quoted price.)
Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes, laying cables errection of poles / struts/stays etc n.exe 10 Sqm on plan not exceeding 1.5 metre in depth and getting out in any type of soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm in any type of soil.
Removing of excavated material (soil) to a distance n.exc 50 metre and depositing where directed at a level n.exc 1.50metre above the starting point
M & L Sand cushioning to PVC under ground cable with screened and washed tibba sand and punning to provide a required cover.
M&L bricks for protection cover to under ground cable (with old size sub class `B` bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10 mm as directed by Engineer in-charge
Repair of Desert Cooler- M & L for Repairs / Servicing of Desert cooler 4000 cum/hrs air flow capacity single phase 230 Volts of various make after disconnecting incoming and outgoing electric/water connection drain out water and carry out minor repair work such as repairing of internal worn out wires, motor ,Pump, Fan vicket, Lead wire , switch regulator , PVC Pipe Name plate , and replacement of unserviceable parts including testing complete all as specified and directed by Engr-in-charge (Note “ Spares required for Replacement shall be measured and paid separately as supply only in respective items)
Supply only wooden (grass) shelving pad for Desert cooler each set weighting not less than 500 grams all as directed of size 75 Cms x 60 Cms.(set of three)
Supply only Fan vickret Blade PVC/iron body with nut Bolt washer for 4000 cum/Hr Desert Cooler of various makes all as per existing one all as specified and directed by Engr-in-charge
Supply only Fan motor AC 240 V for Desert cooler of various makes all as per existing one all as directed
Supply only Submerssible Vertical pump (ISI marked) with suitable head for Desert coolers all as spacified and directed.
Supply only Desert Cooler Fan regulator for 4000 cum/Hr Desert Cooler capacity of various makes all as per existing one all as specified and directed by Engr-in-charge
Supply only PVC Lead wire 1.5 sqmm stranded copper conductor 3 core PVC seathered PVC insulated ISI Marked all as specified and directed.
Supply only PVC flexible pipe (from vertical pump to distributer and distributer to panel ) 15mm dia for Desert cooler including 3 way distributor junction tee set complete.
Supply only PVC pipe connection, both end screwed 18” long 15mm dia with brass nuts and neoprene washers for water cooler/ desert coolers complete all as specified and directed.
S & F Painting of Desert cooler with two coats of enamel paint after surface preparation including paint of alphabets 5 cm hight,5 cm thick not more than 50 Alphabets on each complete all as specified and directed.
S &F ceiling fan 1200 mm sweep complete 5 star rating AC 230 V with aerodynamic blades all as specified and directed.
S & F for exhaust fan 300 mm sweep 230 V, AC complete (without louvers) all as specifed and directed.
Supply and fix Louver made of galavnised iron 300 mm including fixing with suitable fastner complete all as specifed and directed
Supply and fix wall fans 400 mm sweep, copper motor, 50 watt, rated air delivery 70 CMM complete all as specified.
S & Fix Water heater storage type stainless steel inner body 3 star rating geyser suitable for 240V, electric supply and installed complete of capacity 25 ltrs complete with provn of hold fastener of suitable size including drilling and fixing complete.
Supply , installation testing and commissioning outdoor type cubical panel board suitable for 3 phase 4 wire 415 V 50Hz and power coated painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof & general construction confirming to IS 8623/93 comprising of thefollowing- OUTER SHELL The shell shall be made out of 3.15 mm thick CRCA sheet, degree ofprotection for outer shell will be IP-54 & MS angles section 50x50x6 mm frame factoryfabricated with front and back openable double door system lockable/openable from keys both sides having chromium plated19mm dia fancy locks, louvers air vents gaskets for natural air flow U type gasket will be used to make the outer shell completely vermin proof. The bottom of outer shell contains a detachable plate having provision for entry of armoured cable of adequate size with glands. The Outer shell shall be powder coated with pure polyster siemens grey structure RAL7032 shade. The outer shell dimensions shall be adequate to comprise inner shell complete with 75mm space all around and can be taken out when required without disturbing outer shell with a zinc metal coated stand having zinc coated not less than 100 microns. INNER SHELL- Inner shell shall be IP-42 Protection & made out of 2 mm thick CRCA sheet duly compartmentalized for each control gear front and back openable single door system lockable with keys from bottom side having chromium plated 19mm dia fancy lock 02 Nos. in each compartment having louvers and air vent gasket for natural airflow U type gasket shall be used to make inner shall completely vermin proof, TPN bus bar with colour coated on F class insulators made of non hygroscopic non combustile track resistance high strength FRP/SMC/DMC material at an interval not less than 500mm through out the length of TPN bus bar.The cubical shall have a bottom channel of size 75x40mm duly coated with zinc metal coated having thickness not less than 100 microns. A detachable predrilled gland plate of thickness 3.15 mm powder coated should be used at bottom. The inner shell shall be powder coated siemens grey structral RAL 7032 shade. Incoming:- MCCB 200 Amps, 4 Pole, 35 KA, 415 volts, 50 Hz Thermally adjustable between 70-100. - 01 No. Outgoing:- MCCB 100 Amps, 4 Pole, 25KA, 415 volts, 50 Hz Thermally adjustable between 70-100.-02 Nos. MCCB 63 Amps, 4 Pole, 25KA, 415 volts, 50 Hz Thermally adjustable between 70-100.-02 Nos. TPN Bus bar of 300 Amps ratings with colour coded heat shrinkable sleeve (i) Digital Panel multi functional meter to measure current, voltage, frequency & power factor having programmable CT ratio. (ii) ON LOAD Changeover Switch of 200 Amp Capacity including connection with main supply and DG Supply Complete all as specified and directed.
M&L for point wiring suitable for modular fittings/accessories using approved colour coding as per IS, with 1.5 Sqmm single core PVC insulated and unsheathed multi stranded copper conductor FRLS cable of 1100 V grade (ISI marked) in and including concealed conduit with accessories fixed on surface/ceiling by means of PVC sleeve/dash fasteners with cadmium plated screw and teakwood blocks closed recessed for mounting switch,sockets,regulators etc. including, Mild steel Sunken box, earth dolly with zinc coated and 3 mm thick phenolic laminated sheet top cover including 1.5 sqmm single core PVC insulated and unsheathed copper conductor FRLS cable 1100 V grade (ISI marked) earth continuty conductor to common earth and connected as continuous earth wire to earth dolly compiete all as sprcified and ditected for followings :-. (Note:- Cost of moduler switch plate metal flush box and moduler switch plate cover as per site requirement is included in above quoted rate.)
One light/fan/ bell point controlled by one, one way switch
One 3 pin 5 Amp socket outlet on the same board with other switches
One 3 pin 5 Amp socket outlet on independent board with other switches
One light point controlled by two, two way switches
All as per item No 94 above but Point wiring with 2.5 Sqmm copper cable for 3 pin 15 Amps socket outlet on independent board, including 2.5 Sqmm copper cable continuous earth wire and connecting to common earth dolly complete all as specified and directed.
All as per item No 94 above but Point wiring with 4 Sqmm copper cable for 3 pin 15 Amps socket outlet on independent board, including 4 Sqmm copper cable continuous earth wire and connecting to common earth dolly complete all as specified and directed.
S&F switch moduler type type 230/250 volts ISI marked,complete all as speified and directed of following:-
Single pole , one way 5/6Amp rating of module
Single pole, One way 15/16 Amp rating 1 module
Single Pole, two way 6 amp rating 1 module
Supply and fix socket outlet multipurpose moduler type use on top cover(catered in point wiring above) as following:
S & F Socket 230/250 Volts 2 in 1,3 pin 5/6 Amp Ratings 2 modules (Make : Anchor cat Part -14304 or equivelent cat part in other makes as per Appendix 'B'.
S & F Socket Piano type 230/250 Volts 2 in 1,3 pin 15/16 Amp Ratings 2 modules
S & F in repair stepped type electronics fan regulator moduler type type AC 230 volts single pole (ISI marked) 100 Watt, 50 Hz on laminated sheet complete all as specified and directed
supply and fix TPN sheet steel power coated double door vertical distribution board 08 way fitted with two cover one screwed cover for incoming and outgoing MCBs and second for protection of MCBs fitted with colour coated Bus bar neutral link earth bar Din rail suitable for use of 240/415 Volts 50 Hz supply including on incomming MCCB 100 Amps Ratings 4 pole, MCB DP 63 Amps ratings 08 Nos. and RCCB 01 Nos. complete all as specified and directed. (Note: Cost of wall cutting for suitable mounting of DBs in recess alongwith proper connection with suitable lugs and making good disturbed surfaces with PCC work will be inclusive in above item quoted price.)
Supply and fixing steel tubing galvanised light grade for passing cable under road floors or fixing to poles for mechanical protection of under ground cable complete with flat iron clamps made of shape and 12 mm dia bolts nuts and washers fixing where required complete all as specified and directed of size 40 mm dia. (Note: Cost of Cable protection in floors and on walls with 40 mm GI pipe in DBs/Panels will be inclusive in above quoted rate)
Supply & fix in repair LED ceiling lights 2feet x 2feet suitable for exising light fittings ( Economy range ) 6500K/3000 K with electronic driver LED fittings 1 x 36/38/40 W complete with all accessories pre-wired twin core twisted flexible copper conductor cable with suitable size complete. Make- Syska cat Pt No-SSK-PAB-6060B-36W or equivelent cat part in other makes as per Appendix 'B'.
M & L for servicing , testing and minor defect rectification for geyser of any make at site and any capacity including nuts, bolts and any other fixing arangements complete as as specified and directed.
M & L for boring upto 80mm dia under roads/drains/in walls for passing of cables and GI pipes for protection of cable including minor connecting fixtures and fittings complete all as specified and directed.
Ms Kamal Kant Agarwal
SHREE BHAGWATI ENTERPRISES
JAGDAMBA CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .