| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹25.8 L+₹83,981 (3.36%)Rejected-Finance BHAGAT SINGH CHOWK SURATGARH 335804 DISTT SRIGANGANAGAR RAJ | GANGANAGAR | RAJASTHAN | 335804 | L2 | Rejected-Finance Due to not lowest | |
| 3 | L3₹31.7 L+₹6.8 L (27.0%)Rejected-Finance | L3 | Rejected-Finance Due to not lowest | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Eligible enlisted contractor due to as per NIT Criteria |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
21 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE North Bikaner
GE North Bikaner Rajasthan 334001
REPAIR AND MAINTAINANCE OF E M INSTALLATION CLEANING OF OVER HEAD TANKS RAW WATER RESERVOIRS CLEAR WATER RESERVOIRS AT MFFR UNDER GE N BIKANER
2022_MES_528362_1
GE (N) BKN TOKEN NO 23 /2022-2023
Open Tender
Miscellaneous Works
Item Rate
335 days
MFFR
Class D category b i
7 documents required · 7 mandatory
₹500
GE North Bikaner
₹60,000
Yes
2 Sept 2022
3 Jun 2022
28 Jul 2022
3 Jun 2022
21 Jul 2022
18 Jun 2022
Amount
Cleaning of raw water reservoir of capacity 8500KL of 5 metre depth complete by drain out water below the suction pipe by temporary pump arrangement by contractor and taking out sludge/foreign particle from bottom of reservoir by manually or mechanically and depositing at a distance of 200mtr away from the reservoir and cleaning all the walls of reservoir by metal brush and repairing the cracks and damages in walls and floor as per requirement of site and making good with cement and sand mortar, painting of wall and bottom of reservoir with 02 coats of cement base paint & Black and white painting in water proof of measurement scale, cleaning/removing sand and mud around the reservoir up to 5 meter circumstance of reservoir including removing grass and bushes at phase-II West Camp, Devaser water point complete all as specified and directed by Engineer-in-Charge - (cleaning of Water collection chamber Near canal is also included in Lump sump quated rate by tenderer
Ditto- all as per srl No 01 here-in-before but capacity of reservior is 6700 KL at west camp water point kharbara road PH-I.
Ditto- all as per srl No 01 here-in-before but capacity of reservior is 3600 KL at south camp water point.
Ditto- all as per srl No 01 here-in-before but capacity of reservior is 3600 KL at DBS water point.
Ditto- all as per srl No 01 here-in-before but capacity of reservior is 200 KL at East Camp phase-I (RD-160)
Ditto- all as per srl No 01 here-in-before but capacity of reservior is 5000 KL at East Camp phase-II
Ditto- all as per srl No 01 here-in-before but capacity of reservior is 3400 KL at North Camp phase-I (Rajana minor pump house)
Ditto- all as per srl No 01 here-in-before but capacity of reservior is 750 KL at RD 535 water point. Including of Wall repair of reservior complete all as directed by engr-in-charge.
Cleaning of over head reservoir 100 KL capacity complete by drain out water taking out sludge foreign particle from bottom of reservoir and depositing at a distance of 100mtr away from the reservoir cleaning of wall of same by metal brush. Repairing the cracks and damages in wall and floor as per requirement of site and making good with cement and sand mortar. Painting of wall, outside area of OHSR and bottom of reservoir with 02 coats of cement based paint at phase-II South camp water point complete all as specified and directed by Engineer-in-Charge.
All as per item No 9 here-in-before but OHSR capacity 190 KL at Rajana Water point.
All as per item No 9 here-in-before but OHSR capacity 100 KL at DBS Camp
All as per item No 9 here-in-before but OHSR capacity 100 KL at East Camp
Cleaning of PVC Overhead tank 10x10000 liters capacity (i.e. 100 KL)complete by drain out water taking out sludge foreign particle from bottom of all tank and depositing at a distance of 100mtr away from the water point and cleaning of staging roof including all necessary materials and tools at West Camp Ph II Devasar complete all as required at site and directed by Engineer-in-Charge
Cleaning of underground sump of clear water reservoir 100 KL capacity complete by drain out water taking out sludge foreign particle from bottom of reservoir and depositing at a distance of 200mtr away from the sump, cleaning of wall of same by metal brush. Repairing the cracks and damages in wall and floor as per requirement of site and making good with cement and sand mortar. Painting of wall, MS Sheet cover plate, outside area of CWR and bottom of reservoir with 02 coats of cement based paint after inside and outside cleaning/removing sand and mud inside the sum & removing the same up to 5 mtr around the sump including removing grass and bushes at phase-II South camp water point complete all as specified and directed by Engineer-in-Charge.
All as per item No 14 here-in-before but CWR capacity 100 KL at DBS
All as per item No14 here-in-before but CWR capacity 100 KL at East camp
All as per item No 14 here-in-before but CWR capacity 95 KL at Rajana Water point
Excavation in trenches in soft/loose soil not exc 1.5mtr wide and not exc 1.5mtr in depth for taking out old pipe and laying new pipe line etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting complete all as specified and directed by Engineer-in-Charge.
Returning and filling including spreading, levelling, watering and well ramming in layers not exc 25 cm thick in any type of soil complete all as specified and directed by Engineer-in-Charge.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 meter above the starting point complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of existing pipe any type and size in any condition at various location including GI pipe medium grade 50 mm bore (ISI marked) laid in trenches/ road crossings/along walls/ path /drain/floors with and including clamps, nuts, bolts, washers,sockets,elbow etc and all necessary arrangement to connect existing branch pipe of any type and size including all necessary fittings required at site and testing complete all as specified and as directed by the Engineer-in-Charge. (Note:- Earth work shall be measured and paid for separately.)
All as per item No 21 above but size 25mm dia complete all as specified and directed by Engineer-in-Charge.
M & L Taking out u/s rusted corroded GI pipe of size 50 mm dia after cutting/unscrewing including all fittings from trenches /along walls/under roar etc complete all as specified and directed by Engineer-in-Charge.
M & L Taking out u/s rusted corroded GI pipe of size 25 mm dia after cutting/unscrewing including all fittings from trenches /along walls/under roar etc complete all as specified and directed by Engineer-in-Charge.
M & L for repairing the leakage of CI/DI pipe line 150 mm dia incl necessary excavationand bailing out of stagnent water and removing wild bushes/grass 3 mtr away from both sides of pipe line and removing u/s lead from the joint by burning and making new run joint all as directed by Eng-in-Charge.
M & L for repairing the leakage of CI/DI pipe line 100 mm dia incl necessary excavationand bailing out of stagnent water and removing wild bushes/grass 3 mtr away from both sides of pipe line and removing u/s lead from the joint by burning and making new run joint all as directed by Eng-in-Charge.
M & L for repairing the leakage of CI/DI pipe line 80 mm dia incl necessary excavationand bailing out of stagnent water and removing wild bushes/grass 3 mtr away from both sides of pipe line and removing u/s lead from the joint by burning and making new run joint all as directed by Eng-in-Charge.
M & L for repairing the leakage of GI/ pvc pipe line 50 mm dia incl necessary excavationand bailing out of stagnent water and removing wild bushes/grass 3 mtr away from both sides of pipe line and removing u/s fittings from the joint/ leakage point and making new joint/repair with neccessary GI/PVC fiitins and testing or all as directed by Eng-in-Charge.
Supply and fixing in replacement of cast iron sluice valve 80 mm, heavy duty class PN 1:6 ISI marked (IS-14846-2000), long body, both ends flanged, complete with high tensile stainless steel spindle, cast iron hand operated wheel and cap top, nuts, bolts, washers including 3mm thick rubber gasket joints, suitable for 80 mm bore GI/PVC pipe any type any size and also including testing and commissioning complete all as specified and directed by Engineer-in-Charge. Make - Leader/Sant/Kirlosker
Ditto all as per serial item No. 29 here in before but suitable for 100mm bore.Make - Leader/Sant/Kirlosker
Ditto all as per serial item No. 29 here in before but suitable for 150mm bore.Make - Leader/Sant/Kirlosker
Ditto all as per serial item No. 29 here in before but suitable for 200mm bore.Make - Leader/Sant/Kirlosker
Supply and fixing in replacement of existing flexible hose pipe(as per sample approved by Engr in charge) of 100 mm dia suiatable for lorry filling point all as specified & directed by the Engineer-in-Charge.
Supply and Fixing in replacement of Reflex Valve/NRV/Dual plate check valve, PN 1.6 rating of size 80 mm dia with all necessary accessories and testing complete all as specified and directed by Engineer-in-Charge. Make - Leader/Sant/Kirlosker
All as per item No 34 above but size 100mm suitable for 100mm dia GI/DI pipe line
All as per item No 34 above but size 150mm suitable for 150mm dia GI/DI pipe line
Supply and Fixing in repair foot valve of any type & in any condition CI Foot Valve size 80 mm dia conforming to IS suitable for 80mm bore pipe any type i.e thread/flanged type complete all as required at site complete all as specified and directed by Engineer-in-Charge. Make - Leader/Sant/Kirlosker
All as per item No 37 above but size 100mm suitable for 100mm dia GI/DI pipe line Note :- 9 to 38 :- (The contractor must attend the complaint from MEs and resolve the problem within 48 hr , In case contractor failed to rectify the defect within the time limit , apenalty Rs 1000.0 per day will be imposed as penality for the delayed Period)
Supply and Fixing in repair butterfly t valve of any type & in any condition butterfly Valve size 80 mm dia conforming to IS suitable for 80mm bore pipe any type i.e thread/flanged type complete all as required at site complete all as specified and directed by Engineer-in-Charge. Make - Leader/Sant/Kirlosker
S&F in replacement of four pole offload changeover switch 200 Amps, 415 Volts with sheet steel enclosure including disconnecting existing cable connection and reconnecting after fixing the same as directed by Engineer-in-Charge complete all as specified and as directed by Engineer-in-Charge.Make :- Havells HSN code 8563 or equilant in L&T/Siemens//C&S
All as per item No 40 above but suitable for size 100 Amps 415 volts.
All as per item No 40 above but suitable for size 63 Amps 415 volts.
Dismantling the electric induction motor AC 3 Phase, 7.5 HP, 440 V, 1470RPM, 50Cycle of any make and type from the foundation and pump after disconnecting electric cable connection and earthing etc. and transportation to civil workshop for repair/rewinding, strip opening the motor and removing of defective burnt winding, rewinding the motor after cleaning the roter and stator with super enameled copper winding wire of suitable turn and gauge as per the original with proper insulation including varnishing, providing all high grade material and class ‘B’ varnish for insulation, reassembling the complete motor and re-fixing at site with electric cable connection, earthing and testing the motor on full load at site after coupling the pump for its serviceability up to entire satisfaction of Engineer-in-charge.
Removing the existing unserviceable electrical cable connection from star delta starter to motor and replace the same with PVC insulated unsheathed copper conductor multi stranded cable single core 6 x 16 sqm , 1100 volts grade confirming to IS 694 drawn through and including rigid/flexible PVC conduit of suitable size including connecting up complete all as specified and directed by Engineer-in-Charge. .Note:- 6 runs of cable and one run of PVC conduit will be measured as one unit length
Supply and fixing in replacement MCCB four pole Fixed thermal fixed magnetic , 250 Amp, 415 Volts,4Pole , 50 cycle, breaking capacity 50KA complete all as specified and as directed by Engineer-in-charge. Make : L & T/ Havells / Siemens/BCH/ Legrand/Indo Asian
All as per item No 45 above but suitable for size 200 Amps 415 volts.
All as per item No 45 above but suitable for size 100 Amps 415 volts.
Dismantling the electric driven air compressor twin blower rotary type cap 7.5 HP 350 cum/hr pressure 1440 RPM 440 V, 50 Cycle of any make and type from the foundation and disconnecting electric cable connection and earthing etc. and transportation to civil workshop for repairing and replacing the worn out bearings ,suction filter ,pressure relief valve ,pressure gauge and V belts with initial filling new compressure oil of superior grade all as per original quantity and draining out the existing ol and reassembling the complete and re-fixing at site with electric cable connection, earthing and testing theair compressor on full load at site up to entire satisfaction of Engineer-in-charge.
Supply, laying, jointing, testing and commissioning LT XLPE insulated, PVC sheathed armoured heavy duty electric cables LT 1100 volt grades with copper stranded conductor passing through pipes, in duct, on poles,in trenches, under road etc complete all as specified and directed of following :-
(a) 10 Sqmm 4 core
(b) 25 Sqmm 4 core
(c) 35 Sqmm 3.5 core
(d) 50 Sqmm 3.5 core
Rapid Gravity Filter and Sand filter (a) Fine Sand with silt content not more than 5% free from all impurities (0.45 to 0.65mm) Thick (As per sample). It should be cleaned and pass through sieve no. 10 (1.67mm) and should be retain on sieve no.66 (size0.25mm) the Silt should not exceeds 2% complete all as specified and directed by Engineer-in-Charge.
Gravels It should be cleaned hard & uniform quality one free from dirt, clay and organic matters .It should be laid in layer of effective size 5 mm to 40mm complete all as specified and directed by Engineer-in-Charge.
Pressure filter M & L Fine Sand with silt content not more than 5% free from all impurities (0.45 to 0.65mm) Thick (As per sample). It should be cleaned and pass through sieve no. 10 (1.67mm) and should be retain on sieve no.66 (size0.25mm) the Silt should not exceeds 2% complete all as specified and directed by Engineer-in-Charge.
M&l Gravels .It should be cleaned hard & uniform quality one free from dirt, clay and organic matters .It should be laid in layer of effective size 5 mm to 40mm complete all as specified and directed by Engineer-in-Charge.
Taking out the existing filter media of any size from filter bed of tank any depth including removing material to a distance exceeding 50 meter not exc 100 meter complete all as specified and directed by Engineer-in-Charge.
Cleaning and scratching the surface of filter bed walls, floor truffs, drains etc by wire brushes or otherwise to remove the deposited mud silt etc, washing and cleaning all the affected surface with water complete all as specified and directed by Engineer-in-Charge.
Cleaning, washing of existing of natural pebbles (i.e. fine/coarse sand, gravel etc) obtained from serial item No 56.00 here in before for making it free from silt and other deterious material, screening aggreegate of different size and depositing packing in layer as per direction in filter bed etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of foundation frame made out of MS angles/channels etc including drilling holes & welding suitable for 3 to 20 HP monoblock/centrifugal pump set with nut bolts etc as per sample including all necessary arrangements with grouting of foundation bolt in PCC making good damaged foundation complete all as required at site complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of star coupling of rubber for motor pump set of capacity 03 to 40 HP complete all as specified & as directed by Engr-in-charge.
Supply and fixing in replacement of MS Housing for star coupling for motor pump set of capacity 03 to 40 HP complete all as specified & as directed by Engr-in-charge.
Material and labour for existing LT Panel wiring Circuit complete with new internal wiring set connection in panel including all necessary arrangement & testing etc including removing of old unserviceable wiring set, circuit set etc any type any size and in any condition replacement of worn out spare parts as mentioned under resective item No-64 to 69 here in after complete all as specified and directed by Engineer-in-Charge.
Supply and Fixing in replacement of Electronic contactor suitable for 5 to 10 HP Pump set starter, 415 volt, 50 Hz, 3 phase, complete all as specified and directed by Engineer-in-Charge. Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic relay suitable for 5 to 10HP Pump set starter, 415 volt, 50 Hz, 3 phase complete all as specified and directed by Engineer-in-Charge. Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic contactor suitable for 20HP Pump set starter, 415 volt, 50 Hz, 3 phase complete all as specified and directed by Engineer-in-Charge. Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic relay suitable for 20HP Pump set starter, 415 volt, 50 Hz, 3 phase, complete all as specified and directed by Engineer-in-Charge. Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic contactor suitable for 3HP Pump set starter, 415 volt, 50 Hz, 3 phase complete all as specified and directed by Engineer-in-Charge. Make-L&T/Scneider/siemens
Supply and Fixing in replacement of Electronic relay suitable for 3HP Pump set starter, 415 volt, 50 Hz, 3 phase, Make-L&T/Scneider/siemens
Earthing complete with galvanised steel earth plate electrode of size 60cmx 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including earth lea of size 32x6mm GI strip by means of GI bolts/nuts/check nuts/washer/thimbles etc protected by 40mm bore light grade pipe and connecting to main switch board or panel and testing on completion. Earth plate shall be surrounded by packed layer of coat dust 300mm and common salt 15cm thick all around 40mm bore GI light grade pipe for eatering and including funnel, wire mesh 75mm thick cover of RCC 1:2:4 type B-1 with kand including CI frame, PCC (1:3:6) type C-2 (Using 40mm graded stone aggreagate) as in earthing pit including necessary excavtion and rarth work, all as speciied and shown in electrical plate No-3 of SSR Part-I (Notes for srl item No.70 here-in-before :- (i) GI pipe including fittings for watering shall be provided upto plug at top and cost of the same shall be deemed to be included in the unit rate quoted for earthing. (ii) G I pipe 20mm dia light grade from earth electrode upto main switch panel for protection of earth lead wire shall be deemed to be included in the unit rate quoted for earthing).
S&F in replacement of pressure guage of 0 to 10.0 Kg/sqcm with all accessories including all necessary arrangement i.e. cutting,drilling,threading etc in existing pipe required at site & testing complete all as specified and as directed by the Engineer-in-Charge.
Supply and Fixing in replacement of Air Release Valve (ARV) size 50 mm Dia with two air outlet for fixing up in DI/GI/HDPE water supply pipe line including all necessary arrangement i.e. cutting,drilling,threading of 2.5 mtr long GI pipe 50 mm bore ISI mark medium grade as required at site & testing complete all as specified and directed by Engineer-in-Charge.
Material and labour for CI/DI pipe cutting 200 mm dia for water supply header of required length by reducing to required length and for insertion of new branches, tees, collar, tail pieces etc in position and reconnectiting , jointing and testing existing pipeline complete all as specified and directed by Engineer-in-Charge.
Material and labour for CI/DI pipe cutting 150 mm dia for water supply header of required length by reducing to required length and for insertion of new branches, tees, collar, tail pieces etc in position and reconnectiting , jointing and testing existing pipeline complete all as specified and directed by Engineer-in-Charge.
Supplying and laying testing of CI pipe of bore 200 mm (ISI marked) with spigot & socketed ends centrifugally cast, class K-9 suitable for rubber tyton joints laid in trenches complete & re-connection to existiong water pipelines with all neccessary fittings all as specified and directed by Engr-in-Charge. (Note : - Rubber tyton joints and fittings will be measored separately in respective items.
All as per item No 76 here-in-before but suitable for 150 mm dia
Supplying & fixing CI special fitting of any size, type, radius, angle, tapers, increasing, decreasing sockets, tees, tail pieces and collars etc complete up to 150 mm dia complete all as specified and directed by Engineer-in-Charge.
Supply only bleaching powder in 25 Kg bags ISI marked to the extent required for treatment of water complete all as specified and as directed by Engineer-in-Charge.
Supply only Alum grade-4 of best quality in 20 KG brick to the extent required in treatment of water complete all as specified and as directed by Engineer-in-Charge. Make- Marudhar etc.
Dismantling of existing defective induction motor of the following size and make from the foundation, disconnecting the electric connecting coupling pulley and taking out to work shop cutting down and removing existing burnt out copper windings, cleaning of slots and rewinding with solid copper conductor (winding wire) complete including varnishing, drying ovening overhauling greeasing and fixing in the same position making necessary electric connection and testing on induction motor complete all as specified and as directed by Engineer-in-Charge. 40 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Ditto all as per item no 81 but capacity of 20 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Ditto all as per item no 81 but capacity of 15 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Ditto all as per item no 81 but capacity of 12.5/10 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Ditto all as per item no 81 but capacity of 7.5 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Ditto all as per item no 81 but capacity of 5 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Ditto all as per item no 81 but capacity of 3 HP capacity, 03 phase, 415 volt 50 HZ any make/type
Dismantling from foundation frame by disconnecting suction/delivery lines and coupling opening and transport to workshop and re-assembling after repair/replacement of defective parts of centrifugal pump set of capacity 40 HP, Make :- any make and replacement of worn out spare parts as Stuffing box, inter Stage ring, Gland Cap CI with Nut bolt, shaft sleeve bronze, set of gasket broken part of pump set, pump controller, pump seals, pump impeller with locking screw & nut , pump Bearing with housing DE, Discharge nozzle, casing wear ring etc as specified and as directed by engr -in-charge Note:- for Srl No. 14 to 18 :- After repairs testing is carried out it site in presence of MES Rep and warranty of minimum 6 months
Dismantling from foundation frame by disconnecting suction/delivery lines and coupling opening and transport to workshop and re-assembling after repair/replacement of defective parts of centrifugal pump set of capacity 20 HP, Make :- any make and replacement of worn out spare parts as Stuffing box, inter Stage ring, Gland Cap CI with Nut bolt, shaft sleeve bronze, set of gasket broken part of pump set, pump controller, pump seals, pump impeller with locking screw & nut , pump Bearing with housing DE, Discharge nozzle, casing wear ring etc as specified and as directed by engr -in-charge
Dismantling from foundation frame by disconnecting suction/delivery lines and coupling opening and transport to workshop and re-assembling after repair/replacement of defective parts of centrifugal pump set of capacity 12/15 HP, Make :- any make and replacement of worn out spare parts as Stuffing box, inter Stage ring, Gland Cap CI with Nut bolt, shaft sleeve bronze, set of gasket broken part of pump set, pump controller, pump seals, pump impeller with locking screw & nut , pump Bearing with housing DE, Discharge nozzle, casing wear ring etc as specified and as directed by engr -in-charge
Dismantling from foundation frame by disconnecting suction/delivery lines and coupling opening and transport to workshop and re-assembling after repair/replacement of defective parts of centrifugal pump set of capacity 7.5 HP, Make :- any make and replacement of worn out spare parts as Stuffing box, inter Stage ring, Gland Cap CI with Nut bolt, shaft sleeve bronze, set of gasket broken part of pump set, pump controller, pump seals, pump impeller with locking screw & nut , pump Bearing with housing DE, Discharge nozzle, casing wear ring etc as specified and as directed by engr -in-charge
Dismantling from foundation frame by disconnecting suction/delivery lines and coupling opening and transport to workshop and re-assembling after repair/replacement of defective parts of centrifugal pump set of capacity 3/5 HP, Make :- any make and replacement of worn out spare parts as Stuffing box, inter Stage ring, Gland Cap CI with Nut bolt, shaft sleeve bronze, set of gasket broken part of pump set, pump controller, pump seals, pump impeller with locking screw & nut , pump Bearing with housing DE, Discharge nozzle, casing wear ring etc as specified and as directed by engr -in-charge
S&F in replacement of cast iron ditechable joints suitable for 200mm dia DI/GI pipe line including clamps, nuts, bolts, washers,sockets,elbow etc and all necessary arrangement and testing complete all as required at site and directed by engr -in-charge. (Note:- Excavation shall be measured and paid for separately)
All as per item No 93 above but size 150mm suitable for 150mm dia GI/DI pipe line
All as per item No 93 above but size 100/ 80mm suitable for 100mm dia GI/DI pipe line
S&F in replacement of PVC ditechable joints suitable for 200mm dia HDPE/PVC pipe line including clamps, nuts, bolts, washers,sockets,elbow etc and all necessary arrangement and testing complete all as required at site and directed by engr -in-charge (Note:- Excavation shall be measured and paid for separately)
All as per item No 96 above but size 150/160mm suitable for 160/150mm dia HDPE/PVC pipe line
All as per item No 96 above but size 100mm suitable for 100mm dia HDPE/PVC pipe line
Suuply and Fixing in replacement of automatic starter type suitable for 40HP pump set 415 volt, 50 Hz, 3 phase, by using lugs/thimbles complete all as specified and as directed by Engineer-in-Charge. Make :- L&T/Siemens/BCH/ABB/C&S
Suuply and Fixing in replacement of automatic starter any size suitable for 20/15 HP pump set 415 volt, 50 Hz, 3 phase, by using lugs/thimbles complete all as specified and as directed by Engineer-in-Charge. Make :- L&T/Siemens/BCH/ABB/C&S
Suuply and Fixing in replacement of automatic starter typpe any size suitable for 3 to 7.5 HP pump set 415 volt, 50 Hz, 3 phase, by using lugs/thimbles complete all as specified and as directed by Engineer-in-Charge. Make :- L&T/Siemens/BCH/ABB/C&S
M/S Shree Ram Enterprises
M/s Chopra Associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .